• 제목/요약/키워드: Below-freezing

검색결과 182건 처리시간 0.029초

생약제제의 이화학적 품질평가에 관한 연구 -소청룡탕(小靑龍湯)의 분석- (Studies on Physical and Chemical Quality Evaluation of Crude Drugs Preparations -Analysis of So Cheong Ryong Tang-)

  • 정지형;박상일;박성수;박종희
    • 생약학회지
    • /
    • 제29권1호
    • /
    • pp.35-39
    • /
    • 1998
  • The famous prescription of So Cheong Ryong Tang (小靑龍湯)in Chinese herb medicine, which has been used for the treatment of common cold, influenza, asthmatic bronchitis, and bronchial asthma and, is being commercially produced in the form of decoction. However, the storage problem for this dosage form remains unsettled. The quantitative changes of the major constituents, at different temperature and time course, were examined employing HPLC and GC. Cinnamaldehyde, cinnamic acid, ephedrine, albiflorine, paeoniflorin, benzoic acid, glycyrrhizin, and liquiritin were choosen as phytochemical markers. The content of cinnamaidehyde significantly decreased when stored at increased temperature, while that of benzoic acid has increased. By overall consideration of the present experimental data, it was suggested that most constituents are considerably stable when preserved below freezing temperature.

  • PDF

공기분사식 제상장치 개발에 관한 실험적 연구 (Experimental Study for Development of Air Eject Defrost Equipment)

  • 한인근;김창영;김재돌;윤정인
    • 대한기계학회논문집B
    • /
    • 제25권3호
    • /
    • pp.277-284
    • /
    • 2001
  • One of the problems in a refrigerator operation is the frost formation on a cold surface of the evaporator. The frost layer is formed by the sublimation of water vapor when the surface temperature is below the freezing point. This frost layer is usually porous and formed on the cold surface of the evaporator. The frost layer on the surface of a evaporator will make side effect such as thermal resistance. However, these important factors have not been used in determining the defrosting period. Therefore, the proper defrosting operation period based on the new defrosting method is very important, and make a comparison between conventional method like electric defrost and new method in compression work, evaporation pressure, evaporation temperature.

Severe Hypothermia Accompanying Acute Subdural Hemorrhage

  • Kim, Jung-Goan;Kim, Seok-Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제39권3호
    • /
    • pp.228-230
    • /
    • 2006
  • Hypothermia is relatively a common condition and most cases involve mild hypothermia. But severe hypothermia below $30^{\circ}C$ is medical an emergency condition. We report the case of a 41-year-old man who had been left in a manhole for more than 9 hours on a freezing cold water. He was transported to our emergency room in semicomatose state with a body temperature $26.5^{\circ}C$. The patient was warmed with active rewarming. After initial stabilization, the patient was taken for a brain computed tomography and found to have large fronto-temporo-parietal[FTP] subdural hemorrhage. The patient underwent an emergent decompressive craniectomy and hematoma evacuation. After surgery, he recovered to drowsy mentation and vital signs were stable.

히트펌프식 냉난방장치의 철도차량 적용에 관한 연구 (A study on the application Heat Pump to Rolling Stock Air conditioner)

  • 권태균;송영정;정광무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.1689-1696
    • /
    • 2008
  • Heat pumps transfer heat by circulating a substance called a refrigerant through a cycle of evaporation and condensation. But Heat pumps system by only using heat-source is not efficient. Because the mean temperature of North Korean winter season is low, economy of air heat-source heat pump descend. This paper is practiced the simulation on evaluation criteria for Heat pump heating and cooling systems to Rolling Stock. Efficiency of the heat pump in order improving from certainly the development of the technique will be able to prevent a freezing actual condition must proceed. As a result, Below $-10^{\circ}C$ used heating and cooling systems of heat pump format even in cold winter season and is serviceable confirmed with heat source supply circle of the Rolling Stock.

  • PDF

온도 의존성 가변 저항 발열체로 표면 처리된 금속 분리판 제조 및 평가 (Synthesis and Evaluation of Variable Temperature-Electrical Resistance Materials Coated on Metallic Bipolar Plates)

  • 정혜미;노정훈;임세준;이종현;안병기;엄석기
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.73.1-73.1
    • /
    • 2010
  • For the successful cold starting of a fuel cell engine, either internal of external heat supply must be made to overcome the formation of ice from water below the freezing point of water. In the present study, switchable vanadium oxide compounds as variable temperature-electrical resistance materials onto the surface of flat metallic bipolar plates have been prepared by a dip-coating technique via an aqueous sol-gel method. Subsequently, the chemical composition and micro-structure of the polycrystalline solid thin films were analyzed by X-ray diffraction, X-ray fluorescence spectroscopy, and field emission scanning electron microscopy. In addition, it was carefully measured electrical resistance hysteresis loop over a temperature range from $-20^{\circ}C$ to $80^{\circ}C$ using the four-point probe method. The experimental results revealed that the thin films was mainly composed of Karelianite $V_2O_3$ which acts as negative temperature coefficient materials. Also, it was found that thermal dissipation rate of the vanadium oxide thin films partially satisfy about 50% saving of the substantial amount of energy required for ice melting at $-20^{\circ}C$. Moreover, electrical resistances of the vanadium-based materials converge on an extremely small value similar to that of pure flat metallic bipolar plates at higher temperature, i.e. $T{\geq}40^{\circ}C$. As a consequence, experimental studies proved that it is possible to apply the variable temperature-electrical resistance material based on vanadium oxides for the cold starting enhancement of a fuel cell vehicle and minimize parasitic power loss and eliminate any necessity for external equipment for heat supply in freezing conditions.

  • PDF

CFD를 이용한 열회수형 환기장치 운전에 따른 혹한기 공동주택의 실내 열환경 검토 (A Study of the Indoor Thermal Environment in Apartment Buildings in Freezing Weather Operation of Heat Recovery Ventilator by CFD Simulation)

  • 김창연;박종일;김동규;신병환;금종수
    • 설비공학논문집
    • /
    • 제27권6호
    • /
    • pp.293-299
    • /
    • 2015
  • In Korea, it is the law that an apartment building which consists of over 100 households must have a ventilation system installed, either natural or mechanical. The heat recovery ventilator (HRV) is great way to reduce energy consumption. In this research we confirmed that based on site's construction plan and existing diffuser form, performed purpose CFD which simulates operation in temperatures below $-5^{\circ}C$ to circumstances of installation of an HRV in an apartment. As a result of this research we found that when the diffuser's aperture area was adjusted, the distribution of air temperature and residence time of air was more equally distributed and air temperature was higher, compared to when the diffuser has an identical aperture area. We also found that we are able to increase even more air temperature and air distribution of air temperature and residence time of air was even more equally distributed when run in parallel with a splitter damper.

Rat 난포란과 수정란의 발육단계별 유리화 동결 융해후 생존성(FDA-test)에 미치는 영향 (Effects of the Oocyte and Developmental Stages of the Rat Embryos after the Vitrified Freezing on the Survival Rate(FDA-test))

  • 고혁진;김중계
    • 한국수정란이식학회지
    • /
    • 제11권1호
    • /
    • pp.41-50
    • /
    • 1996
  • This experiment was carried out to investigate the ovarian responses of the ovulation point, ovarian weight and size, the number of ovarian follicles and collected embryos, and to study the effects of the developmental stages (oocytes, 2-4 cell. 8-16 cell and morulae), additional levels of Ficoll (0, 15, 30%) on the survival rate (FDA-test) of rat embryos frozen in vitrification solution (20% glycerol + 10% ethylene glycol + 10% sucrose). Sunanarized results was as follows; 1. The mean ovulation point per head was 7, and the weight of ovaries was 0.03g. The size of ovary was 5.9 mm(L) and 4.6 mm(W), and the number of ovarian follicles over and below 2 mm was 4.7 and 8.7, respectively. The number of the collected embryos per head was 5.5 (79%). 2. 2. The FDA score of embryos frozen in 20 G 10 E 10 S without Ficoll was 2.8 (oocyte), 2.6 (2-4 cell), 3.9 (8-16 cell) and 3.6 (morula), respectively. However, there were no significant differences among treatments. 3. The FDA score of embryos frozen in 20 G 10 E 10 S with 15% Ficoll was 3.4 (oocyte), 4.0 (2-4 cell), 4.7 (8-16 cell) and 4.8 (morulae), respectively (P>0.05). 4. The FDA score of embryos frozen in 20 G 10 E 10 S with 30 % Ficoll was 3.7 (oocyte), 3.2 (2-4 cell), 4.4 (8-16 cell) and 4.4 (morulae), respectively (P>0.05). 5. As shown in the above results, the higher survival rate was obtained in the treatment of 15% Ficoll than that of 30%. And the survival rate (FDA-test)of the oocytes and 2-4 cell stages of the rat embryos was lower than that of 8~16 cell and morulae stages. It was considered that 8-16 cell and morulae could be available for the successful freezing by vitrification of rat embryos with 15% Ficoll except for oocytes.

  • PDF

지반의 동결조건을 고려한 열전도 구성방정식과 유한요소해석 (Heat Transfer Equation and Finite Element Analysis Considering Frozen Ground Condition the Cyclic Loading)

  • 김영석;강재모;홍승서;김광진
    • 한국지반신소재학회논문집
    • /
    • 제9권3호
    • /
    • pp.39-45
    • /
    • 2010
  • 동절기 온도가 영하로 떨어짐에 따라서 지표면 부근의 수분을 포함한 흙은 공극속의 수분이 얼음으로 변하면서 부피가 팽창하고, 이렇게 팽창된 지반은 주변 구조물에 영향을 미쳐 지반 구조물의 안전에 위험한 영향을 초래할 수 있다. 동상현상은 토립자, 간극수, 공기로 구성된 다상(multi phase) 구조 속에서 동결이 형성됨에 따른 수분의 이동과 수분이 얼음으로의 상변화(phase change) 등 다변수의 복합적인 물리적 현상을 포함하고 있기 때문에 현재까지 다차원 수치해석에 구성방정식으로 사용할 수 있는 검증되고 신뢰성 있는 모델은 아직도 연구 단계에 있다. 본 논문에서는 간극수의 상변화에 따라 갑작스러운 열용량 증대로 발생하는 수치해석상의 문제를 극복할 수 있는 효율적인 간편식을 유도하고, 포화된 토사나 다공성 암반이 동결할 때의 거동을 재현할 수 있는 열전도 구성방정식과 해석법을 제안하였다. 제안된 식을 사용한 수치해석 결과는 알려진 이론해 및 실내 모형시험 결과와 잘 일치하였다.

  • PDF

이중 버블시트를 이용한 단열양생공법의 한중시공 적용 사례 (Application of Insulation Curing Method with Double Bubble Sheets Subjected to Cold Weather)

  • 홍석민;이충섭;김종;전충근;한민철;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1001-1004
    • /
    • 2008
  • 본 연구는 한중환경에서 이중 버블시트를 이용한 단열보온 양생 공법을 슬래브 및 매스 콘크리트에 활용한 결과를 검토한 것이다. 먼저, 이중 버블시트를 적용한 경우 타설 후 2일까지 외기온이 영하$9^{\circ}C$까지 강하하는 경우에도 슬래브콘크리트는 영상 $6^{\circ}C$에서 $10^{\circ}C$이상을 유지하여 초기동해가 방지됨을 알 수 있었고, 매스콘크리트의 경우에는 중심부 최고온도와 표층부 최고온도차이가 $6^{\circ}C$이하로 나타나 내부구속에 의한 수화열 균열은 발생하지 않은 것으로 판단된다. 본 현장에 적용된 이중버블시트를 이용한 단열보온양생 공법은 동절기 영하에서도 안정된 양생온도 관리로 초기동해를 방지할 수 있었고, 소요강도를 확보할 수 있었다. 또한, 가시설의 설치 해체 공정을 줄여 공기단축 효과와 인건비절감등 양생비용의 감소로써 한중콘크리트의 품질확보에 우수한 효과가 있음과 동시에 단열 양생공법의 경제성이 입증되었다.

  • PDF

고유동콘크리트의 특성에 관한 실험적 연구 (A Study of the Characteristics of the High-Flowable Concrete)

  • 전현규;김대회;이종찬;지석원;유택동;서치호
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.129-134
    • /
    • 2003
  • In this research, we used fly-ash and blast-furnace slag as substitute material of cement and fine aggregate, and we, through experiments, researched and analyzed the features of high-flowable concrete added high efficiency AE water reduction agent. The results are below. 1. Liquefaction generally presented high-slump flow value; on the other hand, partial segregation was observed in case of mixing proportion with 65 cm slump flow and above. This segregation was partially improved in accordance with mixing admixture. 2. Compressive strength according to mixing admixture and increasing mixing ratio of fly-ash were subject to be declined when it was initially cast-in, but its gap was improved when time was fully passed. 3. After mixing blast-furnace slag and fly-ash as substitute material, the result showed that the modulus of elasticity against freezing & melting was improved according to mixing blast-furnace slag and also increased in accordance with increasing pulverulent-body volume. 4. According to increasing the mixing volume of fly-ash, the durability factor was deteriorated because compressive strength became lower as well as air content was decreased when it was initially case-in. 5. The minimum air content to secure durability was 3.7%, for that reason, we had better secure admixture such as air entraining agent when cast-in high-flowable concrete.