• Title/Summary/Keyword: Behavior detection

Search Result 935, Processing Time 0.028 seconds

Design on Fult Diagnosis System based on Dynamic Fuzzy Model (동적포지모델기반 고장진단 시스템의 설계)

  • 배상욱
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.2
    • /
    • pp.94-102
    • /
    • 2000
  • This paper presents a new FDI scheme based on dynamic fuzzy model(DFM) for the unknown nonlinear system, which can detect and isolate process faults continuously over all ranges of operating condition. The dynamic behavior of a nonlinear process is represented by a set of local linear models. The parameters of the DFM are identified by an on-line methods. The residual vector of the FDI system is consisted of the parameter deviations from nominal model and the set of grade of membership values indicating the operating condition of the nonlinear process. The detection and isolation of faults are performed via a neural network classifier that are learned the relationship between the residual vector and fault type. We apply the proposed FDI scheme to the FDI system design for a two-tank system and show the usefulness of the proposed scheme.

  • PDF

A Study on Non-propagating Crack in Fatigue Behavior of Pure Titanium (공업용 순 티타늄의 피로거동에서 정류균열에 관한 연구)

  • Kim, Dong-Yeol;Kim, Jin-Hak;Kim, Min-Geon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.4 s.175
    • /
    • pp.1001-1006
    • /
    • 2000
  • To verify the existing theory, non-propagating crack(NPC) does not exist in Ti which fulfills the good conditions for being of NPC, NPC detection in Ti was tried out. Also, the conception of fatigue limit in Ti and a main cause for NPC being were inquired. NPC was detected in both sharp notch root ( $\rho$=0.02mm) and micro pit (diameter = 0.25mm) which held fast to the end under stressing of fatigue limit. Therefore, the existing theory was identified as mistake. But, NPC can not be detected in smooth specimen. This fact would be due to the presumption that NPC is very small or crack does not initiate in smooth specimen. Anyway, the fatigue limit of Ti does not correspond to critical stress of crack initiation but correspond to critical stress of NPC growth. Measurement on the COD of NPC in Ti showed that the crack tip was closed even under the peak stress level at fatigue limit. But, after stress relieving annealing crack tip was opened. Consequently, compressive residual stress which is induced around the crack tip is considered to be the factor causing the NPC being.

A Novel Scheme for detection of Parkinson’s disorder from Hand-eye Co-ordination behavior and DaTscan Images

  • Sivanesan, Ramya;Anwar, Alvia;Talwar, Abhishek;R, Menaka.;R, Karthik.
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.10 no.9
    • /
    • pp.4367-4385
    • /
    • 2016
  • With millions of people across the globe suffering from Parkinson's disease (PD), an objective, confirmatory test for the same is yet to be developed. This research aims to develop a system which can assist the doctor in objectively saying whether the patient is normal or under risk of PD. The proposed work combines the eye-hand co-ordination behaviour with the DaTscan images in order to determine the risk of this disorder. Initially, eye-hand coordination level of the patient is assessed through a hardware module. Then, the DaTscan image is analysed and used to extract certain geometrical parameters which shall indicate the presence of PD. These parameters are then finally fed into a Multi-Layer Perceptron Neural Network using Levenberg-Marquardt (LM) Back propagation training algorithm. Experimental results indicate that the proposed system exhibits an accuracy of around 93%.

DETECTION OF MICROSCOPIC BEHAVIOR OF LOW VELOCITY IMPACT DAMAGED CFRP LAMINATE UNDER TENSILE LOADING BY ELASTIC WAVES (탄성파 응용기술에 의한 CFRP 복합재료의 저속충격 손상역의 미시적 거동 특성 탐지)

  • 이준현;권오양;이승석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1993.10a
    • /
    • pp.650-655
    • /
    • 1993
  • Carbon/epoxy composite(CFRP) coupons previously damaged by low velocity impact were tested under static tensile loading and microscope progress of damage was characterized by ultrasonic C-scan, Scanning Acoustic Microscopy (SAM) and Acoustic Emission(AE) techniques which were based on the application of elastic waves. The degress of impact damage has been correlated with the AE activity during monotonic or loading/unloading tensile testing as well as the result of ultrasonic test. The coupons were subjected to impact velocities ranged from 0.71 to 2.17 m/sec, which introduced the amount of damage rated as 0%, 10%, 30%, and 50% with reference to the total absorbed energy at fracture. Special attention was paid to determine optimal AE parameters to characterize the microscopic fracture process and to predict the residual strength of composite laminates. AE RMS voltage during the early stage of tensile loading was found an effective parameter to quantify the degree of impact damage. It was also found that the Felicity ratio is closely related to the stacking sequence and the residual strength of the CFRP laminates.

  • PDF

Excellent Carbon Monoxide Sensing Performance of Au-Decorated SnO2 Nanofibers

  • Kim, Jae-Hun;Zheng, Yifang;Mirzaei, Ali;Kim, Sang Sub
    • Korean Journal of Materials Research
    • /
    • v.26 no.12
    • /
    • pp.741-750
    • /
    • 2016
  • Nanofibers(NFs), because of their high surface area and nanosized grains, have appropriate morphologies for use in chemiresistive-type sensors for gas detection applications. In this study, a highly sensitive and selective CO gas sensing material based on Au-decorated $SnO_2$ NFs was fabricated by electrospinning. $SnO_2$ NFs were synthesized by electrospinning and subsequently decorated with various amounts of Au nanoparticles(NPs) by sputtering; this was followed by thermal annealing. Different characterizations showed the successful formation of Au-decorated $SnO_2$ NFs. Gas sensing tests were performed on the fabricated sensors, which showed bell-shaped sensing behavior with respect to the amount of Au decoration. The best CO sensing performance, with a response of ~20 for 10 ppm CO, was obtained at an optimized amount of Au (2.6 at.%). The interplay between Au and $SnO_2$ in terms of the electronic and chemical sensitization by Au NPs is responsible for the great improvement in the CO sensing capability of pure $SnO_2$ NFs, suggesting that Au-decorated $SnO_2$ NFs can be a promising material for fabricating highly sensitive and selective chemiresistive-type CO gas sensors.

6 Clinical Reports of Temporary Severe Amnesia Patients -focusing on amnesia, hysteric convulsion, dissociative disorder (단기 기억상실을 주증(主症)으로 하는 6례(例)의 임상보고 -중기(中氣), 건망(健忘), 해리성 기억장애 중심으로)

  • Oh, Young-Jin;Kim, Bo-Kyung
    • Journal of Oriental Neuropsychiatry
    • /
    • v.16 no.2
    • /
    • pp.287-299
    • /
    • 2005
  • Dissociative disorder is a psychiatric disorder characterized by a sudden loss of memory, but which has no organic disease or explanation. It usually occurs after heavy psychosocial stress or traumatic experience. A transient cerebral ischemic attack (TIA) is an acute episode of temporary and focal loss of cerebral function of vascular origin. TIAs are rapid in onset; symptoms reach their maximal manifestation in fewer than 5 minutes. Manifestations are of variable duration and typically last 2-15 minutes(rarely as long as 24 h). Most TIA durations are less than 1 hour. Of concern is the careful detection of changes in behavior, speech, gait, memory, movement, and vision. TIAs are uncommon in persons younger than 60 years. I treat 6 cases of Sudden Temporary Amnesia Patients with oriental medicine and they are improved. All of them had amnesia for $6{\sim}10\;hours$. During that time, they show behavioral changes and they are not on the state of unconsciousness. After recovery, they also forget what happen at the time. they have some emotional reason too. In conclusion, 4 cases of them belong to dissociative disorder and 2 other cases, TIA.

  • PDF

Efficient Similarity Analysis Methods for Same Open Source Functions in Different Versions (서로 다른 버전의 동일 오픈소스 함수 간 효율적인 유사도 분석 기법)

  • Kim, Yeongcheol;Cho, Eun-Sun
    • Journal of KIISE
    • /
    • v.44 no.10
    • /
    • pp.1019-1025
    • /
    • 2017
  • Binary similarity analysis is used in vulnerability analysis, malicious code analysis, and plagiarism detection. Proving that a function is equal to a well-known safe functions of different versions through similarity analysis can help to improve the efficiency of the binary code analysis of malicious behavior as well as the efficiency of vulnerability analysis. However, few studies have been carried out on similarity analysis of the same function of different versions. In this paper, we analyze the similarity of function units through various methods based on extractable function information from binary code, and find a way to analyze efficiently with less time. In particular, we perform a comparative analysis of the different versions of the OpenSSL library to determine the way in which similar functions are detected even when the versions differ.

Malware Family Recommendation using Multiple Sequence Alignment (다중 서열 정렬 기법을 이용한 악성코드 패밀리 추천)

  • Cho, In Kyeom;Im, Eul Gyu
    • Journal of KIISE
    • /
    • v.43 no.3
    • /
    • pp.289-295
    • /
    • 2016
  • Malware authors spread malware variants in order to evade detection. It's hard to detect malware variants using static analysis. Therefore dynamic analysis based on API call information is necessary. In this paper, we proposed a malware family recommendation method to assist malware analysts in classifying malware variants. Our proposed method extract API call information of malware families by dynamic analysis. Then the multiple sequence alignment technique was applied to the extracted API call information. A signature of each family was extracted from the alignment results. By the similarity of the extracted signatures, our proposed method recommends three family candidates for unknown malware. We also measured the accuracy of our proposed method in an experiment using real malware samples.

Measurements of Peroxyacetyl Nitrates at an Urban and a Rural Site in Korea (도시지역과 청정지역에서의 대기 중 PAN(PeroxyAcetyl Nitrate) 측정)

  • 김세웅;이강웅;김경렬
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.17 no.2
    • /
    • pp.157-167
    • /
    • 2001
  • Although PAN has ong been considered to belong to one of the most characteristic photooxidants, its concentra-tions have rarely been measured in a systematic manner in Korea. The first in-situ Measurements of PAN were made in concert with simultaneous analysis of NO, NO$_2$, $O_3$ and UV-Visible radiation intensity from Seoul and dong-Hae during Spring and early Summer of 1999. The aim of our study was to evaluate the behavior of photo-chemical species in a highly polluted urban air and a relative clean one. PAN were determined using a semi-auto-mated gas chromatograph equipped with an electron captured detection system. Calibration of the PAN was done by synthesizing liquid standards using a strong acid nitration of the corresponding peracid. The PAN concentra-tions were found in the range of a few ppbv in the urban air ad persistently less than a ppbv in the clean rural airs. Diurnal variations of PAN and $O_3$ were also observed consistently during the experiment with maxima occurring during the late daylight hours. While the positive dependency of $O_3$ production and PAN concentrations were ob-served in most occasion, the dependency became deviated significantly under changes in air masses.

  • PDF

Impact Behavior Analysis on Composite Laminate with Damages (손상이 있는 복합적층판의 충격거동 해석)

  • Kim, Sung-Joon;Hong, Chang-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.1
    • /
    • pp.22-28
    • /
    • 2010
  • To detect the damage in composite structure, nondestructive evaluation techniques are widely used. Tapping test is perhaps the most common technique used for the detection of damage in composite laminates. The method is accomplished by tapping the inspection area with light hammer-like device. The tapping test has the ability that indicates damages in a structure due to a localized change of stiffness. The change in vibration signature may be detected by measurement of the dynamic contact force during impact. In this study, it has been shown that the characteristics of impact force histories from a structure during tapping are changed by the presence of damage such as surface crack and delamination. And impact response analysis has been performed on composite rotor blade with crack to investigate the effect of damage.