• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.035 seconds

Microstructure of ZnO Thin Film on Nano-Scale Diamond Powder Using ALD (나노급 다이아몬드 파우더에 ALD로 제조된 ZnO 박막 연구)

  • Park, S.J.;Song, S.O.
    • Journal of the Korean Vacuum Society
    • /
    • v.17 no.6
    • /
    • pp.538-543
    • /
    • 2008
  • Recently a nano-scale diamond is possible to manufacture forms of powder(below 100 nm) by new processing of explosion or deposition method. Using a sintering of nano-scale diamond is possible to manufacture of grinding tools. We have need of a processing development of coated uniformly inorganic to prevent an abnormal grain growth of nano-crystal and bonding obstacle caused by sintering process. This paper, in order to improve the sintering property of nano-scale diamond, we coated ZnO thin films(thickness: $20{\sim}30\;nm$) in a vacuum by ALD(atomic layer deposition) Economically, in order to deposit ZnO all over the surface of nano-scale diamond powder, we used a new modified fluidized bed processing replaced mechanical vibration effect or fluidized bed reactor which utilized diamond floating owing to pressure of pulse(or purge) processing after inserted diamond powders in quartz tube(L: 20 mm) then closed quartz tube by porosity glass filter. We deposited ZnO thin films by ALD in closed both sides of quartz tube by porosity glass filter by ALD(precursor: DEZn($C_4H_{10}Zn$), reaction gas: $H_2O$) at $10^{\circ}C$(in canister). Processing procedure and injection time of reaction materials set up DEZn pulse-0.1 sec, DEZn purge-20 sec, $H_2O$ pulse-0.1 sec, $H_2O$ purge-40 sec and we put in operation repetitive 100 cycles(1 cycle is 4 steps) We confirmed microstructure of diamond powder and diamond powder doped ZnO thin film by TEM(transmission electron microscope) Through TEM analysis, we confirmed that diamond powder diameter was some $70{\sim}120\;nm$ and shape was tetragonal, hexagonal, etc before ALD. We confirmed that diameter of diamond powders doped ZnO thin film was some $70{\sim}120\;nm$ and uniform ZnO(thickness: $20{\sim}30\;nm$) thin film was successfully deposited on diamond powder surface according to brightness difference between diamond powder and ZnO.

The Effect of Sn on Dehydrocyclization of n-Heptane over Pt-Sn/γ-Al2O3 Catalyst (Pt-Sn/γ-Al2O3 촉매상에서 n-Heptane의 탈수소고리화 반응에서 조촉매 주석의 영향)

  • Song, Myeong-Sug;Kim, Moon-Chan;Kim, Kyung-Lim
    • Applied Chemistry for Engineering
    • /
    • v.2 no.4
    • /
    • pp.411-420
    • /
    • 1991
  • The dehydrocyclization of n-heptane was studied over $Pt-Sn/{\gamma}-Al/_2O_3$ catalysts with varying Sn content in a fixed bed continuous flow reactor. The range of experimental conditions was at the temperature between 450 and $550^{\circ}C$, the pressure $20{\times}10^5-50{\times}10^5Pa$, the contact time 0.09 and 0.27 hr and the $H_2/H.C$. mole ratio 10. The conversion and selectivity of dehydrocyclization increased with increasing temperature, but decreased with increasing pressure. When we use Sn as a promoter, the selectivity of dehydrocyclization changesa a little, but the conversion was increased and the selectivity of isomerization increased a lot. The activation energy of dehydrocyclization of n-heptane was 34.5 kcal/mol over 0.6 wt % Pt-0.6 wt % $Sn/{\gamma}-Al_2O_3$.

  • PDF

Characteristics of Toluene Removal in a Biotrickling Filter with Zeolite/Polyethylene Composite Media (제올라이트/폴리에틸렌 복합 담체를 이용한 Biotrickling Filter에서 톨루엔 제거 특성)

  • Hong, Sung-Ho;Lee, Chung-Sik;Lee, Jea-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.6
    • /
    • pp.573-580
    • /
    • 2005
  • This study was to investigate the removal characteristics of toluene in a gas stream by using a biotrickling filter packed with zeolite-contained polyethylene media. The specific surface area and the void fraction of the media were $500\;m^2/m^3$ and 82%. The surface roughness of the media was higher than that of pure polyethylene media. The toluene removal efficiency decreased with increasing the inlet toluene concentration and gas flow rate. The maximum elimination capacity of toluene in the biotrickling filter was $64\;g/m^3{\cdot}hr$. During 200 days operation, toluene removal efficiency was maintained from 90% to 98% until 167 days, hereafter, it was rapidly reduced with a rise in pressure drop due to an excess proliferation of biomass on the media. Pressure drop and removal capability of the biotrickling filter was fully recovered after backwashing.

Analysis of Particles Motion in Vertical Rayleigh Flow (수직 Rayleigh 유동내의 입자 거동 해석)

  • Ko, Seok-Bo;Jun, Yong-Du;Lee, Kum-Bae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.6
    • /
    • pp.447-456
    • /
    • 2007
  • Suspended particles behavior when they go through a vertical riser with heat transfer is of significant concern to system designers and operators in pneumatic transport, various processes such as in chemical, pharmaceutical and food industries. When it comes with the energy system, that knowledge is critical to the reliable design practices of related equipment as heat exchangers, especially in the phase of system scale-up. Without haying a good understanding of the related physics, many scale-up practices based on their pilot plant experience suffer from unexpected behaviors and problems of unstable fluidization typically associated with excessive pressure drop, pressure fluctuation and even unsuccessful particle circulation. In the present study, we try to explain the observed phenomena with related physics, which may help understanding of our unanswered experiences and to provide the designers with more reliable resources for their work. We selected hot exhaust gas with solid particle that goes through a heat exchanger riser as our model to be considered. The effect of temperature change on the gas velocity, thermodynamic properties, and eventually on the particles motion behavior is reviewed along with some heat transfer analyses. The present study presents an optimal riser length at full scale under given conditions, and also defines the theoretical limiting length of the riser. The field data from the numerical analysis was validated against our experimental results.

The Effects of 30-Minutes of Pre-Warming on Core Body Temperature, Systolic Blood Pressure, Heart Rate, Postoperative Shivering, and Inflammation Response in Elderly Patients with Total Hip Replacement under Spinal Anesthesia: A Randomized Double-blind Controlled Trial (30분의 수술전 가온이 고관절 전치환술 노인 환자의 수술중 심부체온, 수축기압, 심박동수, 수술후 전율 및 염증반응에 미치는 효과)

  • Cheon, You Mi;Yoon, Haesang
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.4
    • /
    • pp.456-466
    • /
    • 2017
  • Purpose: This study was designed to determine the effects of pre-warming on core body temperature (CBT) and hemodynamics from the induction of spinal anesthesia until 30 min postoperatively in surgical patients who undergo total hip replacement under spinal anesthesia. Our goal was to assess postoperative shivering and inflammatory response. Methods: Sixty-two surgical patients were recruited by informed notice. Data for this study were collected at a 1,300-bed university hospital in Incheon, South Korea from January 15 through November 15, 2013. Data on CBT, systemic blood pressure (SBP), and heart rate were measured from arrival in the pre-anesthesia room to 3 hours after the induction of spinal anesthesia. Shivering was measured for 30 minutes post-operatively. C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR) were measured pre-operatively, and 1 and 2 days postoperatively. The 62 patients were randomly allocated to an experimental group (EG), which underwent pre-warming for 30 minutes, or a control group (CG), which did not undergo pre-warming. Results: Analysis of CBT from induction of spinal anesthesia to 3 hours after induction revealed significant interaction between group and time (F=3.85, p=.008). In addition, the incidence of shivering in the EG was lower than that in the CG ($x^2=6.15$, p=.013). However, analyses of SBP, heart rate, CRP, and ESR did not reveal significant interaction between time and group. Conclusion: Pre-warming for 30 minutes is effective in increasing CBT 2 and 3 hours after induction of spinal anesthesia. In addition, pre-warming is effective in decreasing post-operative shivering.

Development and Characterization of High Temperature Filter (내열성여과포의 개발 및 기초성능 규명)

  • 박영옥;구철오;임정환;김홍룡;손재익;이영우
    • Journal of Energy Engineering
    • /
    • v.7 no.1
    • /
    • pp.103-112
    • /
    • 1998
  • A high temperature fabric filter was developed and characterized in order to solve the various problems encountered in the operation of industrial fabric filters. Four kinds of dusts generated in the typical domestic industry were used for its characterization, coke dust from a steel manufacturing process, cement dust from a cement manufacturing process, fly ash from a fluidized-bed combustor, and incinerator ash from a waste plastics incinerator. The physical and chemical properties of the high temperature fabric filter were analyzed in terms of mean flow pore pressure, bubble point pore diameter, mean flow pore diameter, pore size distribution, and the changes in tensile strength and initial elastic modulus under $SO_2$ and $NO_2$ atmospheres. Pressure drop, dust penetration, and figure of merit for the fabric filter were also investigated in a bench-scale filter testing unit. The fabric filter developed in this study had good physical and chemical filter properties and showed a very applicability to typical industrial dusts treatments.

  • PDF

A Study on the Response Performances under Transient Operating Conditions in a Turlblocharged Diesel Engine (터보과급 디젤기관의 과도운전시 응답성능에 관한 연구)

  • 최낙정;이창식
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.8
    • /
    • pp.1575-1582
    • /
    • 1992
  • This study describes the response performances of actual engine speed, turbocharger speed, air mass flow rate through engine, boost pressure ratio, exhaust temperature and combustion efficiency for a six-cylinder four-stroke turbocharged diesel engine during the change in operating conditions by using the computer simulation with test bed. In order to obtain the transient conditions, a suddenly large load was applied to the simulation engine with the several kinds of inertia moment in turbocharger and engine, and engine set speed. From the results of this study, the following conclusions were summarized The inferior response performances was mainly caused by turbocharger lag, and air mass flow rate and boost pressure ratio were closely related to the turbocharger speed. A reduced moment of turbocharger inertia resulted in less transient speed drop and much faster recovery to the steady state of the engine. The increase of moment of engine inertia reduced cyclic variation of engine speed. When a large load was applied to the engine at high speed, the engine could be fastly recovered. However, when the same load was applied to the engine at low speed, the engine was stalled.

Nursing Interventions Classification(NIC) Use in Korea : Oriental Medicine Hospitals and General Hospitals (간호중재분류(NIC)에 근거한 간호중재수행분석 II -한방병동과 일반병동 간호사를 중심으로-)

  • 염영희;김성실;김인숙;박원숙;김은주
    • Journal of Korean Academy of Nursing
    • /
    • v.29 no.4
    • /
    • pp.802-816
    • /
    • 1999
  • The purposes of this research were to identify nursing interventions performed by Korean nurses and to compare the interventions performed by nurses working in the oriental medicine hospitals and with those performed by nurses working in the general hospitals. The samples consisted of 144 Korean nurses working in three hospitals, 70 nurses working in the oriental medicine hospitals and 74 nurses working in the general hospitals. The Nursing Interventions Classification (NIC) Use Questionnaire developed by the Iowa Intervention Project team was translated to Korean and verified using the method of back-translation. The questionnaire consists of 433 intervention labels and definition. Thirteen interventions were used at least daily by nurses working in the oriental medicine hospitals, while twenty-one interventions were used at least daily by nurses working in the general hospitals. The most frequently used interventions by nurses working in the oriental medicine hospitals were Documentation, Shift Report Vital Signs Monitoring, Pressure Ulcer Prevention, Positioning, Fall Prevention, Exercise Promotion, Intravenous (IV) Therapy, Pressure Ulcer care, and Bed Rest Care in that crder. For nurses working in the general hospitals the most frequent intervention was Analgesic Administration, followed by the interventions of Medication Administration : Parenteral and Intravenous Therapy (IV) Therapy, Documentation, Intravenous(IV) Insertion, Shift Report, Fall Prevention, Vital Signs Monitoring, Medication Adnninistraction : and, Fluid Monitoring, and Medication Maragement in that order. The interventions performed least often by nurses working in the oriental medicine hospitals were Hemodialysis Therapy and Bleeding Reduction : Antepartum Uterus, while the interventions performed least often by nurses working in the general hospitals were Rape Trauma Treatment and Contact Lens Care. The nurses working in the oriental medicine hospitals performed the interventions in the Physiological : Complex domain significantly more often than the nurses working in the general hospitals, while the nurses working in the general hospitals performed the intervention in the Behavior domain significantly more often than the nurses working in the oriental medicine hospitals. This study suggests that further study will be needed to developed and validate more interventions sensitive to Korean culture.

  • PDF

A Study on K2 Rifle Recoil Measurement and Analysis for Virtual Reality Marksmanship (가상현실 사격훈련을 위한 탄종별 K2 소화기의 주퇴산출 및 분석 연구)

  • Kim, Jong-Hwan;Jin, Youngho;Kwak, Yunki
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.1
    • /
    • pp.13-27
    • /
    • 2020
  • Purpose: The purpose of this study is to present a recoil measurement and analysis of K2 rifle for the development of a virtual reality marksmanship training in the Republic of Korea Army. Methods: For the recoil measurement, a test-bed is built by a barrel that has exact dimensions of K2 rifle and three piezoelectric pressure sensors mounted on the barrel. Data of over 200 rounds of 5.56mm M193 and K100 bullets are collected and analyzed from live fire experiments. For the recoil analysis, both the free recoil method and the gas exhaust aftereffect method are used to calculate a recoil velocity, momentum and kinetic energy of K2 rifle by applying the law of conservation of momentum. In addition, a new method is proposed that uses the third law of motion and the chamber pressure model for the recoil measurement Results: The results show how different between the previous and proposed methods with respect to M193 and K100 bullets of K2 rifle. In M193, the free recoil method demonstrates 1.113, 4.197, and 2.335, the gas exhaust aftereffect method computes 1.698, 6.407, and 5.441, and the proposed method calculates 0.990, 3.734, and 1.848 in recoil velocity, momentum and kinetic energy, respectively. In K100, the free recoil method demonstrates 1.190, 4.487, and 2.669, the gas exhaust aftereffect method computes 1.776, 6.699, and 5.949, and the proposed method calculates 1.060, 3.998, and 2.119 in recoil velocity, momentum and kinetic energy, respectively. Conclusion: This study implements live fire experiments to provide recoil velocity, momentum, and kinetic energy of K2 rifle using both M193 and K100 bullets. For the development of the army virtual reality marksmanship, the results in this paper would be useful to design and produce a gun and/or a rifle of virtual reality.

A Study on Sandbag Management, vital sign, Pain and Hemorrhage after Kidney Biopsy in Children with Nephrotic Syndrome (신장증 환아의 신생검후 모래주머니 적용시간에 따른 활력징후, 통증 및 출혈에 관한 연구)

  • Cho Kyoul-Ja;Paik Seung-Nam;Park Soon-Hee
    • Child Health Nursing Research
    • /
    • v.9 no.1
    • /
    • pp.28-35
    • /
    • 2003
  • Purpose: The purpose of this study is to investigate correlations in vital sign changes, the severity of pain, signs of complications, and the duration of sandbag management in order to suggest a standardized practice related to sandbag management in children with Nephrotic Syndrome(NS). Method: From October 2000 to May 2001, seventy children with NS who underwent kidney biopsy were interviewed at one hospital in Seoul Korea, and participated in this study. Result: 1) The average sandbag applying time after kidney biopsy was 18.1 hours. 2) Systolic blood pressure and respiration increased until 15 minutes after kidney biopsy, after then, they decreased signifi- cantly (systolic BP, p= .006; respiration, p= .029). However, no significant changes were noted in diastolic blood pressure and pulse. 3) Pain was reported minimal for 1 hour after kidney biopsy. The severity of pain increased until 12 hours after the procedure, then, decreased significantly(p= .0001). 4) Reported complications were hematuria (74.7%) and abnormal sonogram (32.9%). No apparent bleeding on the biopsy region was reported in any children. Conclusion: From these findings, it is possible to change the protocols of the duration of absolute bed rest time and sandbag application management shortly after kidney biopsy. But it is needed to study the fit protocols for kidney biopsy. Several implications in nursing practice are suggested. 1) Replicated studies for more participants are needed. 2) Further research on the effect of sandbag application after kidney biopsy is required. 3) The best duration of sandbag application management after kidney biopsy need to be investigated.

  • PDF