• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.024 seconds

Adsorption Equilibria of Organic Solvent in an Activated Carbon Fixed Bed (활성탄 고정층에 있어서 유기용제의 흡착평형)

  • Kim, Jung-Geul;Park, Young-Hae;Lee, Young-Sei
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.8 no.1
    • /
    • pp.37-45
    • /
    • 2005
  • Adsorption equilibrium data of pure solvent vapors (n-Hexane, Toluene, MEK) as well as their binary mixtures on activated carbon (sorbonorit $B_4$) were experimentally determined in the range of 293.2~323.2 K and beyond saturated vapor pressure corresponding to experimental temperature. Langmuir, Freundlich, LRC, W-VSM, FH-VSM were estimated for the predication of single component as well as binary mixtuer systems. The isosteric heat of adsorption at infinite dilution of pure n-hexane, toluene, MEK on activated carbon were 45.18, 25.85, 34.62 Kcal/mol, respectively, also, n-hexane-toluene binary adsorption of activated carbon formed an azeotrope at 293.2 K and total pressure 5.1~10.3 mmHg.

  • PDF

The Characteristics of Body Pressure Distribution on Sleeping Posture (침대의 수면자세에 따른 체압분포의 특성)

  • 박세진
    • Science of Emotion and Sensibility
    • /
    • v.2 no.1
    • /
    • pp.95-103
    • /
    • 1999
  • 침대에서의 체압분포는 수면 안락감에 중요한 영향을 미치는 요인중의 하나로 고려되어져 왔다. 체압분포는 사람의 몸무게에 의하여 침대와 누운사람 사이의 접촉면에서 발생하는 압력의 분포를 말한다. 안락한 체압분포 패턴을 결정하기 위하여 사용자가 침대 8부분의 높이를 조절할 수 있는 가변침대를 사용하였다. 체압분포 측정은 각 수면자세(바로 누운 자세, 옆으로 누운 자세, 엎드린 자세)에서 가변침대의 초기상태와 피실험자가 편안한 체압분포 패턴을 유지하도록 높이를 조절한 상태에서 이루어졌다. 본 연구에서는 각 수면자세에서 체압비와 선호하는 체압비의 특징을 알아보았다. 본 연구의 결과를 요약하면 다음과 같다. - 각 수면자세에서 엉덩이 부분의 체압비가 가장 높았으며, 바로 누운 자세는 40% 이상의 체압비가 엉덩이에 집중한다. - 각 수면자세에서 전체적으로 머리와 다리의 높이가 다른 부분보다 높은 것을 선호하는 경향을 나타난다. - 바로 누운 자세에서는 유추를 기준으로 신체가 W형이 되도록 머리, 요추, 대퇴부분의 높이를 올리는 것을 선호한다. - 엎드린 자세는 머리와 다리부분의 높이를 증가시킴으로써 신체이 곡선이 U형이 되도록 하는 것을 선호한다.

  • PDF

Parametric Study of the Effects of Train Wind on Running Stability (열차풍 효과가 고속열차 주행안정성에 미치는 파라메타 연구)

  • Nam, Seong-Won
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2519-2523
    • /
    • 2008
  • When constructing a high-speed railroad, the reduction of the distance between track centers and the width of track bed will save the construction cost. However the shortening the distance between track centers may cause the stability problems due to higher wind pressure. Therefore the extensive technical review and aerodynamical study should be performed to determine the adequate distance between track centers. In this study, the impact that the increase in wind pressure due to the change of aerodynamic phenomena with the change of the distance between track centers may have on two trains passing by each other was predicted, and the stability of train operation was analyzed in order to review the distance between track centers suitable to Honam HSR trains. We conducted the parametric study of the effects of train wind on the running stability.

  • PDF

The Invention of New Electro-Mechanical Brake Calipers Utilizing Patent Analysis Results (특허분석 결과를 활용한 새로운 전기기계 브레이크의 발명)

  • Han, In-Hwan;Park, Sang-Il
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.1
    • /
    • pp.125-132
    • /
    • 2007
  • Within the framework of brake-by-wire technology, this paper presents five types of novel models of electro-mechanical disk brake calipers with self-servo mechanism which provides self-servo effect of boosting a friction force generated between the brake pad and the rotor disk surface. The models have been developed utilizing patent map analysis results of previous invents of electro-mechanical brake calipers. The feasibility of the developed motor-driven brake caliper models have been validated through the dynamic simulation analysis. Among the developed models, the caliper mechanism with separated pressure plate was designed especially in detail and was made as a pilot. The pilot caliper has been installed on the simple test bed constructed with domestic passenger car brake components, and its function and effectiveness have been validated through several types of experimental tests.

Three Cases of Pressure Ulcer Treated with Hwangryunhaedok-tang Pharmacopuncture and Jaungo (黃連解毒湯약침과 紫雲膏도포를 병행한 욕창 환자 치험 3례)

  • Heo, Jong-won;Eom, Tae-min;Oh, Jeong-min;Choi, Ko-eun;Kim, Hyun-tae;Seol, In-chan;Kim, Yoon-sik;Yoo, Ho-ryong;Jo, Hyun-kyung
    • The Journal of Internal Korean Medicine
    • /
    • v.36 no.3
    • /
    • pp.419-426
    • /
    • 2015
  • Objectives This study reports three cases of pressure ulcer treated with Hwangryunhaedok-tang pharmacopuncture. Methods Three patients with pressure ulcers were treated by Hwangryunhaedok-tang pharmacopuncture and Jaungo at the Oriental Medicine Hospital of Daejeon University. Hwangryunhaedok-tang pharmacopuncture and Jaungo was administrated once a day with simple dressing. Thereafter, we observed the pressure ulcers macroscopically. Results and Conclusions After 3 weeks, wound sizes were reduced and tissue regeneration was accelerated. In conclusion, Hwangryunhaedok-tang pharmacopuncture and Jaungo are effective to treat pressure ulcers, but more studies will be required to validate its use in pressure ulcers.

A Study of Hydrodynamics and Reaction Characteristics in Relation to the Desulfurization Temperatures of Zn-Based Solid Sorbent in the Lab-scale High Pressure and High Temperature Desulfurization Process (실험실규모 고온고압건식탈황공정의 수력학적 특성 및 탈황온도에 따른 아연계 탈황제의 반응특성 연구)

  • Kyung, Dae-Hyun;Kim, Jae-Young;Jo, Sung-Ho;Park, Young Cheol;Moon, Jong-Ho;Yi, Chang-Keun;Baek, Jeom-In
    • Korean Chemical Engineering Research
    • /
    • v.50 no.3
    • /
    • pp.492-498
    • /
    • 2012
  • In this study, hydrodynamics such as solid circulation rate and voidage in the desulfurizer and the reaction characteristics of Zn-based solid sorbents were investigated using lab-scale high pressure and high temperature desulfurization process. The continuous HGD (Hot Gas Desulfurization) process consist of a fast fluidized bed type desulfurizer (6.2 m tall pipe of 0.015 m i.d), a bubbling fluidized bed type regenerator (1.6 m tall bed of 0.053 m i.d), a loop-seal and the pressure control valves. The solid circulation rate was measured by varying the slide-gate opening positions, the gas velocities and temperatures of the desulfurizer and the voidage in the desulfurizer was derived by the same way. At the same gas velocities and the same opening positions of the slide gate, the solid circulation rate, which was similar at the temperature of $300^{\circ}C$ and $550^{\circ}C$, was low at those temperatures compared with a room temperature. The voidage in the desulfurizer showed a fast fluidized bed type when the opening positions of the slide gate were 10~20% while that showed a turbulent fluidized bed type when those of slide gate were 30~40%. The reaction characteristics of Zn-based solid sorbent were investigated by different desulfurization temperatures at 20 atm in the continuous operation. The $H_2S$ removal efficiency tended to decrease below the desulfurization temperature of $450^{\circ}C$. Thus, the 10 hour continuous operation has been performed at the desulfurization temperature of $500^{\circ}C$ in order to maintain the high $H_2S$ removal efficiency. During 10 hour continuous operation, the $H_2S$ removal efficiency was above 99.99% because the $H_2S$ concentration after desulfurization was not detected at the inlet $H_2S$ concentration of 5,000 ppmv condition using UV analyzers (Radas2) and the detector tube (GASTEC) which lower detection limit is 1 ppmv.

A Study on Biofilter for Hydrogen Sulfide Removal (황화수소 제거를 위한 Biofilter에 관한 연구)

  • Bin, Jeong-In;Lee, Byeong-Heon;Kim, Jung-Gyun;Gwon, Seong-Hyeon;Kim, Sang-Gyu;Lee, Min-Gyu
    • Journal of Environmental Science International
    • /
    • v.10 no.4
    • /
    • pp.287-292
    • /
    • 2001
  • A packed bed of volcanic rock was used as deodorizing material to remove hydrogen sulfide($H_2$S) from air in a laboratory-scale column, and was inoculated with Thiobacillus sp. as $H_2S$ oxidizer. The effects of volcanic rock particle size distribution on system pressure drop were examined. Various tests have been conducted to evaluate the effect of $H_2S$ inlet concentration and CBCT(Empty Bed Contact Time) on $H_2S$ elimination. The pressure drop for particles of size range from 5.6 to 10 mm was 14 mm$H_2S$/m at a representative gas velocity of 0.25m/s. Biofilter using scoria and Thiobacillus sp. could get the stable removal efficiencies more than 99.9% under $H_2S$ inlet concentrations in the range from 30 to 1,100ppm at a constant gas flow rate of $15.2{\ell}$/min. $H_2S$ removal efficiencies greater than 99% were observed as long as EBCT was longer than 8sec at the 250ppm of $H_2S$ inlet concentration. When EBCT was reduced to 5.5 sec, $H_2S$ removal efficiency decreased by about 12 percent. The maximum $H_2S$ elimination capacity was determined to be 269g-$H_2S/m^3{\cdot}hr$.

  • PDF

Direct Bonding of Cu/AlN using Cu-Cu2O Eutectic Liquid (Cu-Cu2O계 공융액상을 활용한 Cu/AlN 직접접합)

  • Hong, Junsung;Lee, Jung-Hoon;Oh, You-Na;Cho, Kwang-Jun;Riu, Doh-Hyung;Oh, Sung-Tag;Hyun, Chang-Yong
    • Journal of Powder Materials
    • /
    • v.20 no.2
    • /
    • pp.114-119
    • /
    • 2013
  • In the DBC (direct bonding of copper) process the oxygen partial pressure surrounding the AlN/Cu bonding pairs has been controlled by Ar gas mixed with oxygen. However, the direct bonding of Cu with sound interface and good adhesion strength is complicated process due to the difficulty in the exact control of oxygen partial pressure by using Ar gas. In this study, we have utilized the in-situ equilibrium established during the reaction of $2CuO{\rightarrow}Cu_2O$ + 1/2 $O_2$ by placing powder bed of CuO or $Cu_2O$ around the Cu/AlN bonding pair at $1065{\sim}1085^{\circ}C$. The adhesion strength was relatively better in case of using CuO powder than when $Cu_2O$ powder was used. Microstructural analysis by optical microscopy and XRD revealed that the interface of bonding pair was composed of $Cu_2O$, Cu and small amount of CuO phase. Thus, it is explained that the good adhesion between Cu and AlN is attributed to the wetting of eutectic liquid formed by reaction of Cu and $Cu_2O$.

High Pressure Operation Characteristics of Pilot Scale Entrained-Bed Gasification System Using ABK Coal (ABK탄을 이용한 pilot급 분류층 석탄가스화기 시스템의 고압 운전특성)

  • Chung, Seokwoo;Yoo, Sangoh;Jung, Woohyun;Lee, Seungjong;Yun, Yongseung
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.105.2-105.2
    • /
    • 2010
  • 석탄의 직접 연소 대신 고온/고압의 조건에서 불완전연소 및 가스화 반응을 통하여 일산화탄소(CO)와 수소($H_2$)가 주성분인 합성가스를 제조하여 이용하는 석탄 가스화 기술은 현실적인 에너지원의 확보를 위한 방법인 동시에 이산화탄소를 저감할 수 있는 기술이라 할 수 있다. 따라서, 본 연구에서는 non-slagging 방식의 pilot급 분류층 석탄가스화기를 대상으로 고압 미분탄공급장치, 합성가스 냉각장치, 고온 집진장치 등을 연계하여 상용급 석탄가스기와 유사한 $1,300^{\circ}C$, 20 kg/$cm^2$의 운전조건에서 미분탄의 안정적인 공급을 통한 양질의 합성가스 제조 및 제조된 합성가스의 분기 공급특성 시험을 진행하였다. 그리고, 고압 미분탄공급장치는 공급호퍼에 저장된 미분탄을 고온/고압 조건으로 운전되는 석탄가스화기에 공급하기 위한 설비로서, 이러한 고압 미분탄공급장치를 이용한 기류수송 방식의 미분탄 공급 기술은 가스화기 설계 및 운전제어 기술과 더불어 석탄가스화기 시스템의 안정적 연속운전을 위한 가장 핵심적인 기술 중 하나라고 할 수 있다. 따라서, 본 연구에서는 아역청탄인 인도네시아 ABK탄을 대상으로 향후 dense phase 고압 기류수송을 목적으로 하는 고압 미분탄공급장치의 성능특성을 시험을 진행하였는데, 시험 결과 73 kg/h 조건에서 20 kg/$cm^2$의 가스화기에 대한 안정적인 미분탄 공급특성을 확인할 수 있었으며, 이러한 미분탄 공급 조건에서 CO 40~45%, $H_2$ 16~20%, $CO_2$ 5~8% 조성의 양질의 합성가스를 평균적으로 $230{\sim}50Nm^3/h$ 안정적으로 제조할 수 있었다.

  • PDF

Implement the system of the Position Change for Obstructive sleep apnea patient (폐쇄성수면 무호흡 환자의 자세변환 시스템 구현)

  • Ye, Soo-young;Eum, Sang-hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.6
    • /
    • pp.1231-1236
    • /
    • 2017
  • In this study, we developed a system that can change position to improve obstructive sleep apnea. Blocking of the breathing airway caused by obstruction of the apnea, lateral position is provided by the airway to improve the apnea. We used a pressure sensor (FSR402) in the form of an array to determine the position of patient. The air cylinder was controlled to raise and lower the bed. As a result of calculating the pressure difference between the supine position and the lateral position, it was $0.41{\pm}0.30$ and $1.09{\pm}0.73$. In other words, when the patient is lateral position, the difference between the sensor values on the right and left side is large. Therefore, it is confirmed that the system can maintain airway to breath for improvement of obstructive sleep.