• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.028 seconds

A Study on Prediction Model of Heat Transfer Coefficient in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes (다관형 고밀도 순환유동층 열교환기의 열전달계수에 대한 예측모델 연구)

  • Park, Sang-Il
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.288-293
    • /
    • 2005
  • The pressure distribution and heat transfer coefficient were measured at room temperature in the high suspension density CFB heat exchanger with multiple vertical tubes and the effective density of CFB was determined. The theoretical model for predicting heat transfer coefficient was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement between them.

  • PDF

A Study on Prediction Model of Flow and Heat Transfer in the Circulating Fluidized Bed Heat Exchanger with Multiple Vertical Tubes (다관형 순환유동층 열교환기의 유동 및 전열성능 예측모텔 연구)

  • Park, Sang-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.3
    • /
    • pp.263-268
    • /
    • 2007
  • The pressure drop and heat transfer coefficient were measured at room temperature in a CFB heat exchanger with multiple vertical tubes. The circulation rate of solid particles was also measured. The theoretical model for predicting heat transfer coefficient using the solid flowrate was developed in this study. The model predictions were compared with the measured heat transfer coefficient to show relatively good agreement.

Pier Scour Prediction in Pressure Flow

  • Choi, Gye-Woon;Ahn, Sang-Jin;Kim, Jong-Sup
    • Korean Journal of Hydrosciences
    • /
    • v.6
    • /
    • pp.23-37
    • /
    • 1995
  • In this experimental paper, the maximum scour depth at pier was student. The model of the pier of San Gye bridge in the Bocheong stream was set for the experimental studies. Several model verification processes were conducted through the roughness comparisons between model and prototype, pursuing scour depth variations with time depending upon channel bed variation, the comparison of the ratios between falling velocities and shear velocities in the model and prototype, and the comparison of pier scour depths between experimental data and field measuring data. The experiments were conducted in the free flow conditions and pressure flow conditions. The maximum scour depth at piers in the pressure flow conditions is almost twice as much as compared to the free flow conditions. Also, the maximum scour depth variations are indicated in the figures based on the Froude numbers, opening ratios, water depths and approaching angles in the free surface flow conditions.

  • PDF

Fulminant Headache after Epiduroscopy -A case report- (경막외강 내시경술후 발생한 전격성 두통 -증례 보고-)

  • Oh, Wan-Soo;Lee, Seung-Jun;Hong, Ki-Hyuk
    • The Korean Journal of Pain
    • /
    • v.13 no.1
    • /
    • pp.130-133
    • /
    • 2000
  • Epiduroscopy is a new imaging and invasive technique that has become increasingly popular in the diagnosis and therapy of spinal pain syndrome. However, the risk of epiduroscopy is a major concern due to its invasiveness. The complications include hematoma, infection, neural damage, cardiac failure and raising of intracranial pressure. We have experienced a case of severe diffuse headache and dizziness following 1 day after epiduroscopy. Emergent brain MRI finding has no remarkable sign. The patient was admitted for 5 days to be treated with bed rest, adequate hydration and pain control with analgesics. After the treatments, she was recovered without residual sequelae and discharged. We need to take greater care of the undesirable effects detected intra- and post epiduroscopy, especially sign of increased intracranial pressure. Therefore, close monitoring of intracranial pressure is necessary during epiduroscopy.

  • PDF

A Study on the Effect of Cycle Variation on Scavenging pressure in 2-Stroke Diesel Engine (2행정 디젤엔진의 소기압력이 사이클변동에 미치는 영향에 관한 연구)

  • Yoon, Chang-Sik;Kim, Chi-Won;Kim, Gi-Bok
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.19 no.3
    • /
    • pp.154-159
    • /
    • 2016
  • Recently it has been focused that the automobile engine has developed in a strong upward tendency for the use of the high viscosity and poorer quality fuels in achieving the high performance, fuel economy, and emission reduction. Therefore it is not easy to solve the problems between low specific fuel consumption, and exhaust emission control at automotive engine In this study, it is designed and used the test bed which is installed with fuel injector controller. In addition to equipped engine using CRDI by controlling the injection timing with modulator, it has tested and analyzed the engine cycle variation characteristics, as it is varied that they are the operating parameters: fuel injected quantity, injection timing, engine speed and scavenging pressure.

A Numerical Study on Coughed Particle Dispersion and Deposition in Negative Pressure Isolation Room according to Particle Size (음압격리병실에서의 기침 토출입자의 입경에 따른 확산 및 침적에 대한 수치해석 연구)

  • Jung, Minji;Hong, Jin Kwan
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.2
    • /
    • pp.37-44
    • /
    • 2018
  • Purpose: This study investigates the influences of coughing direction and healthcare worker's location on the transport characteristics of coughed particles in airborne infection isolation room (AIIR), which is commonly called negative pressure isolation room, with a downward ventilation system. Methods: Computational Fluid Dynamics (CFD) was used to simulate the airflow and for tracing the behavior of particles. Results: The results show that the airflow pattern and coughing direction have a significant influence on the characteristics of particle dispersion and deposition. When healthcare workers are in the isolation room with the patient who is lying on the bed, it is recommended to be located far from the anteroom to reduce the exposures from infectious particles. And when the patient is lying, it is more effective in removing particles than when the patient is in Fowler's position. Although it is an isolation room that produces unidirectional flow, coughing particles can spread to the whole room and a large number of particles can be deposited onto patient, bed, side rails, healthcare worker, ceiling, floor, and sidewall. Implications: Following the patients' discharge or transfer, terminal cleaning of the vacated room, furniture, and all clinical equipment is essential. Also, it is necessary to establish detailed standard operating procedure (SOP) in order to reduce the risk of cross-contamination.

Improvement of pavement foundation response with multi-layers of geocell reinforcement: Cyclic plate load test

  • Khalaj, Omid;Tafreshi, Seyed Naser Moghaddas;Mask, Bohuslav;Dawson, Andrew R.
    • Geomechanics and Engineering
    • /
    • v.9 no.3
    • /
    • pp.373-395
    • /
    • 2015
  • Comprehensive results from cyclic plate loading at a diameter of 300 mm supported by layers of geocell are presented. The plate load tests were performed in a test pit measuring $2000{\times}2000mm$ in plane and 700 mm in depth. To simulate half and full traffic loadings, fifteen loading and unloading cycles were applied to the loading plate with amplitudes of 400 and 800 kPa. The optimum embedded depth of the first layer of geocell beneath the loading plate and the optimum vertical spacing of geocell layers, based on plate settlement, are both approximately 0.2 times loading plate diameter. The results show that installation of the geocell layers in the foundation bed, increase the resilient behavior in addition to reduction of accumulated plastic and total settlement of pavement system. Efficiency of geocell reinforcement was decreased by increasing the number of the geocell layers for all applied stress levels and number of cycles of applied loading. The results of the testing reveal the ability of the multiple layers of geocell reinforcement to 'shakedown' to a fully resilient behavior after a period of plastic settlement except when there is little or no reinforcement and the applied cyclic pressure are large. When shakedown response is observed, then both the accumulated plastic settlement prior to a steady-state response being obtained and the resilient settlements thereafter are reduced. The use of four layers of geocell respectively decreases the total and residual plastic settlements about 53% and 63% and increases the resilient settlement 145% compared with the unreinforced case. The inclusion of the geocell layers also reduces the vertical stress transferred down through the pavement by distributing the load over a wider area. For example, at the end of the load cycle of the applied pressure of 800 kPa, the transferred pressure at the depth of 510 mm is reduced about 21.4%, 43.9%, 56.1% for the reinforced bases with one, two, and three layers of geocell, respectively, compared to the stress in the unreinforced bed.

A Study on the Removal Efficiency of VOCs and Operating Characteristics by Using of Bioscrubber Trickling Filter(BSTE) (Bioscrubber Trickling Filter(BSTF)의 VOCs 제거 및 운전 특성에 관한 연구)

  • Park, Jin-Do;Suh, Jung-Ho;Lee, Hak-Sung
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.4 s.85
    • /
    • pp.309-315
    • /
    • 2005
  • Volatile organic compounds (VOCs) and odor materials are major sources of air pollution in Ulsan city, where much chemical plants are located. Therefore, it is necessary to develop a new reactor which can remove VOCs and odor materials effectively and be equipped at the end of pipe easily. A modified reactor (bioscrubber trickling filter, BSTF), which have both characteristics of biofilter and bioscrubber, was developed and tested on its reactivity with several VOCs using two types of media, fiber and activated carbon 4- ceramic(A/C). It was observed that the removal efficiencies of several types of VOCs such as acetaldehyde, ethylalcohol, butanol, diethylamine and triethylamine were up to $95\%$ when they had about 100 ppm of initial concentration and 80 seconds of residence time. Good attachment of microorganisms to both media, where it is thought the reaction efficiency can be determined according to the amount of microorganisms attachment, observed with scanning electron microscopy(SEM). Initial pressure drops of the packed bed with both media were 229 $mmH_2O/m$ at A/C column and 670 $mmH_2O/m$, respectively. However, maximum pressure drop of fiber column during the operation was over 1,647 $mmH_2O/m$. Therefore, it was thought that the fiber material would not suitable to use in the local plant as a packed bed media.

The depressive effect of S'NC nerve control treatment in hypertension patients (고혈압 환자에서 뇌신경조절의학 S'NC의 혈압강하 효과)

  • Han, Chang-Hyun;Han, Sang-Yeob;Shin, Mi-Suk;Choi, Sun-Mi
    • Korean Journal of Oriental Medicine
    • /
    • v.13 no.3
    • /
    • pp.87-95
    • /
    • 2007
  • Objectives : The aim of this study was to investigate the antihypertensive effect of S'NC nerve control treatment in hypertensive patients. Methods: We measured the blood pressure of 5 patients who were admitted in the Oriental Medical Clinic of S'NC Medicine Research Institute from 19th April 2007 to 29th June 2007. Eligible participants had systolic blood pressure ${\ge}$140mmHg or diastolic blood pressure ${\ge}$90mmHg. Blood pressure measurements were after the patient had been in bed rest for at least 10 min. Ten sessions of S'NC nerve control treatment over 2 weeks were performed in the patients. Blood pressure were measured twice before and after each treatment. Results : After 2 weeks, blood pressure reduction was observed in the treatment patients, with an average decline of systolic blood pressure up to 21mmHg and diastolic blood pressure up to 20mmHg. But, there were not statiscally significant The effects of S'NC nerve control treatment by measuring time on blood pressure were as follows: In a systolic blood pressure(p=0.087) and diastolic blood pressure(p=0.609) was gradually deceased not significantly from 1st to 10th. Conclusion: These results suggest that S'NC nerve control treatment may be efficacious in decreasing arterial blood pressure in hypertensive patients. Controlled trials investigating the efficacy of S'NC nerve control treatment for lowering blood pressure are warranted.

  • PDF

Forced Flow Dryout Heat Flux in Heat Generating Debris Bed (열을 발생하는 Debris층에서의 강제대류 Dryout 열유속)

  • Cha, Jong-Hee;Chung, Moon-Ki
    • Nuclear Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.273-280
    • /
    • 1986
  • The purpose of this study is to obtain the experimental data of the forced flow dryout heat flux in a heat generating debris bed which simulates the degraded nuclear reactor core after severe accident. An experimental investigation has been conducted of dryout heat flux in an inductively heated bed of steel particles with upward forced flow rising coolant circulation system under atmospheric pressure. The present observations were mainly focused on the effects of coolant mass flux, particle size, bed height, and coolant subcooling on the dryout heat flux The data were obtained when carbon steel particles in the size distribution 1.5, 2.5, 3.0 and 4.0 mm were placed in a 55 mm ID Pyrex glass column and inductively heated by passing radio frequency current through a multiturn work coil encircling the column. Distilled water was supplied with variation of mass flux from 0 to 3.5 kg/$\textrm{cm}^2$ s as a coolant in the tests, while the bed height was selected as 55 mm and 110 mm. Inlet temperature of coolant varied by 2$0^{\circ}C$ and 8$0^{\circ}C$. The principal results of the tests are: (1) Dryout heat flux increases with increase of upward forcing mass flux and particle size; (2) The dryout heat flux at the zero mass flux obviously depends on the Particle size as Previous studies; (3) The forced flow dryout heat flux in the shallow bed is somewhat higher than that in the deep bed,

  • PDF