• Title/Summary/Keyword: Bed Pressure

Search Result 540, Processing Time 0.025 seconds

The Association between Blood Pressure and Obstructive Sleep Apnea-Hypopnea Syndrome

  • Kim, Cheon-Sik
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.46 no.3
    • /
    • pp.106-110
    • /
    • 2014
  • Obstructive sleep apnea-hypopnea (OSAH) is known to be related to nocturnal blood pressure (BP) and hypertension. The aim of this study was to evaluate the prevalence of hypertension according to the apnea-hypopnea grading. A total of 2,210 adults with snoring and obstructive sleep apnea were referred to our sleep center from July 2009 to May 2013. Clinical blood pressure (BP) was measured before sleeping (bedtime BP) and immediately after waking up in the next morning (morning BP). Subjects were classified into four groups based on the apnea-hypopnea index (AHI) from PSG as follows: control group (n=470) simple snoring and with AHI<5; mild group (n=577) with $AHI{\geq}5$ and <15; moderate group (n=508) $AHI{\geq}15$ and <30; and severe group (n=655) with $AHI{\geq}30$. The differences and correlations between BP and PSG parameters according to the AHI groups were analyzed. Patient's were classified as nomentensive (blood pressure <120/90 mmHg, n=700), prehypertensive (blood pressure < $140-120{\leq}mmHg$, n=1297) hypertensive (blood pressure ${\geq}140/90mmHg$, n=214) according to the office blood pressure measurements. The comparison of sleep parameters showed that OSA groups had a significantly higher stage N1 (control group vs. moderate OSA, severe OSA; $66.4{\pm}30.7$ vs. $85.5{\pm}36.6$, $128.4{\pm}57.3$, p<0.001) and total arousal number (control vs. moderate OSA, severe OSA; $110.7{\pm}47.7$ vs. $150.8{\pm}56.6$, $236.6{\pm}95.8$, p<0.001) compared to control group. The comparison of sleep parameters showed that OSA groups had a significantly lower stage N2 (control group vs. moderate OSA, severe OSA; $172.6{\pm}47.2$ vs. $150.7{\pm}50.5$, $120.3{\pm}57.4$, p<0.001), stage N3 (control group vs. moderate OSA, severe OSA; $38.4{\pm}33.4$ vs. $27.4{\pm}26.0$, $56.1{\pm}27.5$, p<0.001), REM (control group vs. moderate OSA, severe OSA; $64.3{\pm}25.5$ vs. $56.1{\pm}27.5$, $47.3{\pm}25.9$, p<0.001) and mean SaO2% (control group vs. moderate OSA, severe OSA; $90.0{\pm}3.5$ vs. $82.5{\pm}5.5$, $70.0{\pm}8.8$, p<0.001) compared to control group. The Apnea-hypopnea index was significantly higher in OSA groups, increased systolic and diastolic blood pressure than in the nomentensive group (bed time systolic pressure vs. AHI; <120 vs. 120-139, 140-159, >159; $17.5{\pm}18.6$ vs. $24.9{\pm}21.0$, $31.0{\pm}25.7$, $42.3{\pm}31.7$, p<0.001), (bed time diastolic pressure vs. AHI; 60-79 vs. 80-89, 90-99, >99; $19.3{\pm}19.7$ vs. $22.4{\pm}20.3$, $29.8{\pm}23.3$, $38.8{\pm}28.5$, p<0.001). AHI was positively correlated with morning systolic pressure, diastolic pressure, bed time systolic pressure and diastolic pressure (r=0.314, 0.279, 0.233 and 0.200, respectively, p<0.001). We conclude that BMI, Age, neck circumference and AHI increase with the blood pressure.

Linking Clinical Events in Elderly to In-home Monitoring Sensor Data: A Brief Review and a Pilot Study on Predicting Pulse Pressure

  • Popescu, Mihail;Florea, Elena
    • Journal of Computing Science and Engineering
    • /
    • v.2 no.2
    • /
    • pp.180-199
    • /
    • 2008
  • Technology has had a tremendous impact on our daily lives. Recently, technology and its impact on aging has become an expanding field of inquiry. A major reason for this interest is that the use of technology can help older people who experience deteriorating health to live independently. In this paper we give a brief review of the in-home monitoring technologies for the elderly. In the pilot study, we analyze the possibility of employing the data generated by a continuous, unobtrusive nursing home monitoring system for predicting elevated(abnormal)pulse pressure(PP) in elderly(PP=systolic blood pressure-diastolic blood pressure). Our sensor data capture external information(behavioral) about the resident that is subsequently reflected in the predicted PP. By continuously predicting the possibility of elevated pulse pressure we may alert the nursing staff when some predefined threshold is exceeded. This approach may provide additional blood pressure monitoring for the elderly persons susceptible to blood pressure variations during the time between two nursing visits. We conducted a retrospective pilot study on two residents of the TigerPlace aging in place facility with age over 70, that had blood pressure measured between 100 and 300 times during a period of two years. The pilot study suggested that abnormal pulse pressure can be reasonably well estimated (an area under ROC curve of about 0.75) using apartment bed and motion sensors.

Numerical Simulation of the Liquid Flow in the Lower Part of the Blast Furnace - A Cold Flow Case (고로하부 액체유동에 대한 수치해석 사례 - 냉간유동)

  • Jin, Hong-Jong;Choi, Sang-Min;Jung, Jin-Kyung
    • Journal of the Korean Society of Combustion
    • /
    • v.13 no.2
    • /
    • pp.33-41
    • /
    • 2008
  • The high permeability of the gas in the molten iron of the dripping zone of the blast furnace is a major factor in achieving the stable operation of a furnace with high productivity. Basic studies of the liquid flow behavior in a packed bed are necessary to grasp the effect of various operational changes on conditions in the dropping zone. Molten iron and slag together playa critical role in the lower zone, transporting mass and energy, while impairing and redistributing the gas flow. In turn, molten iron and slag undergo physical and chemical changes, and are redistributed radially as they descend to the hearth. In this research, mathematical formulations are derived for the gas and the liquid. The solid phase is fixed with constant porosity. The information for the molten iron and slag includes the hold-up, velocity, pressure, and information related to the areas of interaction between the gas and the liquid, and the solid and the liquid. Predictable results include the velocity, pressure and temperature distribution. Additional parameters include the packed particle size and the air blast rate.

  • PDF

Numerical prediction of hydrogen storaging performance of finned metal hybride beds (휜이 달린 수소저항합금 베드의 수소저장 성능의 수치적 예측)

  • Kim, Myeong-Chan;Lee, Sang-Yong;Gu, Jae-Hak
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.4
    • /
    • pp.520-529
    • /
    • 1998
  • Heat and mass transfer behaviors of metal hydride beds were predicted by solving a set of volume-averaged equations numerically both for the gas (hydrogen) and the solid(metal hydride) phases. Time variations of temperature and hydrogen concentration ratio distributions were obtained for internally cooled, cylindrical-shaped beds with metal(aluminum) fins imbedded in them. Also, time variations of the space-averaged hydrogen concentration ratio were obtained. Temperature and velocity of the coolant, hydrogen pressure at the gas inlet, and the fin spacing were taken as the parameters. The hydrogen absorption rate increases with the higher velocity and the lower temperature of the coolant, and with the decrease of the fin spacing. Increasing of the hydrogen pressure at the gas inlet also promotes the rate of absorption though the increasing rate gradually slows down. The amount of the hydrogen storage per unit volume of the bed decreases with the tighter fin spacing despite of the higher absorption rate ; therefore, there should be an optimum fin spacing for a given volume of the system and the amount of the hydrogen storage, in which the absorption rate is the highest.

Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • Kim, N.H.;Kim, J.S.;Lee, Y.P.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

A Study of Hydrodenitrogenation of Quinoline Catalyzed by Sulfided $Ni-Mo/\gamma - Al_2O_3$ (황화 $Ni-Mo/\gamma - Al_2O_3$ 촉매상에서 Quinoline의 수소첨가탈질반응에 관한 연구)

  • 최응수;이원묵;김경림
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.5 no.1
    • /
    • pp.52-61
    • /
    • 1989
  • The hydrodenitrogenation of quinoline dissolved in n-heptane was studied over sulfided Ni-Mo/$\gamma-Al_2O_3$ catalyst at the range of the temperature between 553 K and 673 and the total pressure between $20 \times 10^5$ Pa and $60 \times 10^5$ Pa in a fixed bed flow reactor. Quinoline conversion was very high at relatively low temperature and total pressure, and decreased with quinoline partial pressure. The thermodynamic equilibrium between quinoline and Py-THQ existed in wide ranges of experimental conditions and shifted in favor of quinoline at higher temperature. At the range of the temperature betwwen 553 K and 673 K and at the total pressure $60 \times 10^5$ Pa, the quinoline reaction rate was 1st order with respect to the concentr4ation of quinoline and its apparent activation energy was 7.15 Kcal/mole.

  • PDF

Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube (수직관내 유리알-물 유동의 압력손실 및 열전달 성능)

  • 김내현;김정식;이윤표
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1996.04a
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

A Study on the Heat Storage System for Chemical Heat Pump Using Inorganic Hydrates(I) - Heat Storage Characteristics - (화학열펌프에 있어서의 무기수화물계 축열시스템에 관한 연구(I) - 탈수 축열 성능연구 -)

  • Park, Young-Hae;Kim, Jong-Shik
    • Solar Energy
    • /
    • v.15 no.3
    • /
    • pp.29-38
    • /
    • 1995
  • The heat-storage characteristics accompanied by exothermic reaction at the regeneration of $Ca(OH)_2$ in tile heat-storage mode of a chemical heat pump system using a $Ca(OH)_2/CaO$ reversible thermochemical reaction was examined in a lab-scale unit. In this heat-storage mode, the particle bed of CaO could be regenerated by heating the $Ca(OH)_2$ packed bed to the higher temperature at which the equilibrium pressure in the reactor is greater than the water vapor pressure in the condenser. The results are i) the dehydration, thermal decomposition, rate of $Ca(OH)_2$ was higher at the lower part of particle bed than at the upper part, ii) in the reactor, the dehydration was proceeded along radial and axial direction, from inner part to the outer part, which explains heat transfers from the center to wall and from the tenter to lower or upper part of reactor.

  • PDF

Numerical Study on Steam-Methane Reaction Process in a Single Tube Considering Porous Catalyst (다공성 촉매를 고려한 단일튜브 내의 수증기-메탄 개질에 관한 수치해석 연구)

  • Moon, Joo Hyun;Lee, Seong Hyuk;Yoon, Kee Bong;Kim, Ji Yoon
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.56-62
    • /
    • 2014
  • The present study investigated numerically heat and mass transfer characteristics of a fixed bed reactor by using a computational fluid dynamics (CFD) code of Fluent (ver. 13.0). The temperature and species fraction were estimated for different porosities. For modeling of the catalyst in a fixed bed tube, catalysts were regarded as the porous material, and the empirical correlation of pressure drop based on the modified Eugun equation was used for simulation. In addition, the averaged porosities were taken as 0.545, 0.409, and 0.443 and compared with non-porous state. The predicted results showed that the temperature at the tube wall became higher than that estimated along the center line of tube, leading to higher hydrogen generation by the endothermic reaction and heat transfer. As the mean porosity increases, the hydrogen yield and the outlet temperature decreased because of the pressure drop inside the reformer tube.

Effects of Drag Models on the Hydrodynamics and Heat Transfer in a Conical Fluidized Bed Combustor (원추형 유동층 연소기의 수력학적 특성 및 열전달에 항력 모델이 미치는 영향에 대한 연구)

  • Kang, Seung Mo;Abdelmotalib, Hamada;Ko, Dong Guk;Park, Woe-Chul;Im, Ik-Tae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.11
    • /
    • pp.861-869
    • /
    • 2015
  • In this study, wall to bed heat transfer and hydrodynamic characteristics in a conical fluidized bed combustor was investigated using computational fluid dynamics method. A two-fluid Eulerian-Eulerian model was used with applying the kinetic theory for granular flow(KTGF). The effects of the two drag models, Gidaspow and the Syamlal-O'Brien model, different inlet velocities($1.4U_{mf}{\sim}4U_{mf}$) and different particle sizes on the hydrodynamics and heat transfer were studied. The results showed that the hydrodynamic characteristics such as bed expansion ratio and pressure drop were not affected significantly by the drag models. But the heat transfer coefficient was different for the two drag models, especially at lower gas inlet velocities and small particle sizes.