• Title/Summary/Keyword: Beat Signal

Search Result 137, Processing Time 0.023 seconds

An Adaptive Classification Algorithm of Premature Ventricular Beat With Optimization of Wavelet Parameterization (웨이블릿 변수화의 최적화를 통한 적응형 조기심실수축 검출 알고리즘)

  • Kim, Jin-Kwon;Kang, Dae-Hoon;Lee, Myoung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.30 no.4
    • /
    • pp.294-305
    • /
    • 2009
  • The bio signals essentially have different characteristics in each person. And the main purpose of automatic diagnosis algorithm based on bio signals focuses on discriminating differences of abnormal state from personal differences. In this paper, we propose automatic ECG diagnosis algorithm which discriminates normal heart beats from premature ventricular contraction using optimization of wavelet parameterization to solve that problem. The proposed algorithm optimizes wavelet parameter to let energy of signal be concentrated on specific scale band. We can reduce the personal differences and consequently highlight the differences coming from arrhythmia via this process. The proposed algorithm using ELM as a classifier show high discrimination performance between normal beat and PVC. From the experimental results on MIT-BIH arrhythmia database the performances of the proposed algorithm are 98.1% in accuracy, 93.0% in sensitivity, 96.4% in positive predictivity, and 0.8% in false positive rate. This results are similar or higher then results of existing researches in spite of small human intervention.

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • Kim, Min-Seok;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.9
    • /
    • pp.172-178
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state -of-the-art reaches the region of sub-nanometers. So far, the demand has been met by increasing the clock speed that drives the electronics involved fur the phase measurement of the Doppler shift, but its further advance is being hampered by the technological limit of modem electronics. To cope with the problem, in this investigation, we propose a new scheme of phase -measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with a stable reference signal generated from a special phase- locked-loop. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special form of frequency up-down counting technique is combined with the super-heterodyning. This allows performing required phase unwrapping simply by using programmable digital gates without 2n ambiguities up to the maximum velocity guaranteed by the original beat frequency.

A Study on the Precise Distance Measurement for Radar Level Transmitter of FMCW Type using Correlation Anaysis Method (상관분석법을 이용한 FMCW 타입 레이더 레벨 트랜스미터의 정밀 거리 측정에 관한 연구)

  • Ji, Suk-Joon;Lee, John-Tark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.7
    • /
    • pp.1024-1031
    • /
    • 2012
  • In this paper, FMCW type radar level transmitter using correlation analysis method is implemented for precise distance measurement of cargo tank. FMCW type radar level transmitter is the device for distance measurement which calculates the distance by analyzing the beat frequency, that is, the frequency difference between Tx and RX signal from radar antenna using Fast Fourier Transform(FFT), but compensated algorithm like Zoom FFT is needed for the improvement of the frequency precision because the frequency precision of FFT is limited depending on sampling frequency and the number of sampling data. In case of Zoom FFT, the number of sampling data and noisy signal are the main factor influencing the measurement accuracy of Zoom FFT like FFT. Therefore, in order to overcome the limited environment and achieve the precise measurement, correlation coefficient is used for the distance measurement and the errors of measurement are verified to be in the range of ${\pm}1mm$.

Development of Holter ECG Monitor with Improved ECG R-peak Detection Accuracy (R 피크 검출 정확도를 개선한 홀터 심전도 모니터의 개발)

  • Junghyeon Choi;Minho Kang;Junho Park;Keekoo Kwon;Taewuk Bae;Jun-Mo Park
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.23 no.2
    • /
    • pp.62-69
    • /
    • 2022
  • An electrocardiogram (ECG) is one of the most important biosignals, and in particular, continuous ECG monitoring is very important in patients with arrhythmia. There are many different types of arrhythmia (sinus node, sinus tachycardia, atrial premature beat (APB), and ventricular fibrillation) depending on the cause, and continuous ECG monitoring during daily life is very important for early diagnosis of arrhythmias and setting treatment directions. The ECG signal of arrhythmia patients is very unstable, and it is difficult to detect the R-peak point, which is a key feature for automatic arrhythmias detection. In this study, we develped a continuous measuring Holter ECG monitoring device and software for analysis and confirmed the utility of R-peak of the ECG signal with MIT-BIH arrhythmia database. In future studies, it needs the validation of algorithms and clinical data for morphological classification and prediction of arrhythmias due to various etiologies.

High-speed, High-resolution Phase Measuring Technique for Heterodyne Displacement Measuring Interferometers. (헤테로다인 변위 측정 간섭계의 고속, 고분해능 위상 측정)

  • 김승우;김민석
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.203-206
    • /
    • 2002
  • One of the ever-increasing demands on the performances of heterodyne interferometers is to improve the measurement resolution, of which current state-of-the-art reaches the region of sub-nanometers. We propose a new scheme of phase-measuring electronics that reduces the measurement resolution without further increase in clock speed. Our scheme adopts a super-heterodyne technique that lowers the original beat frequency to a level of 1 MHz by mixing it with electrically generated reference signal. The technique enables us to measure the phase of Doppler shift with a resolution of 1.58 nanometer at a sampling rate of 1 MHz. To avoid the undesirable decrease in the maximum measurable speed caused by the lowered beat frequency, a special from of frequency up-down counting technique is combined with the super-heterodyning. This alloys performing required phase unwrapping simply by using programmable digital gates without 2$\pi$ ambiguities up to the maximum velocity of 2.35 m/s.

  • PDF

The Design and Implementation of TV Tuner for the Digital Terrestrial Broadcasting (지상파 디지털 방송용 TV 튜너 설계 및 구현)

  • 정영준;김재영;최재익;박재홍
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.11 no.2
    • /
    • pp.302-312
    • /
    • 2000
  • Digital TV tuner for 8-VSB modulation was developed with satisfying the requirements of ATSC. Double frequency conversion and active tracking filter was used in order to suppress IF beat and image band, which results in reducing the interference between adjacent channels and multi-channels. The implemented digital TV tuner has excellent performance such as the wide dynamic range, good flatness in passing band, and low phase noise. The developed tuner is available to handle the digital and analogue television signal at the same time.

  • PDF

Ka-Band FMCW Sensor with High Linearity (고선형성을 갖는 Ka대역 FMCW 센서)

  • Kim, Jaehwan;Lee, Sungju;Kwon, Hyukja;Yang, Youngoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.6
    • /
    • pp.671-678
    • /
    • 2014
  • This paper presents a Ka-band FMCW sensor that has high linearity by improving a nonlinear behavior of the voltage controlled oscillator. Due to the nonlinear characteristics of the voltage controlled oscillator for the conventional method, the drift of beat frequency can cause inaccuracy and errors to the extracted results. A Ka-band FMCW signal with fast transition time could be generated by using both direct digital synthesizer and phase locked loop in this research. The implemented FMCW sensor showed very high accuracy in beat frequency through the test.

A Study on the Analysis of Ciliary Beat Frequency in Human Respiratory Tract n Vivo (레이저 산란 기법을 이용한 인체 기도 내 섬모 운동 신호의 분석에 관한 연구)

  • 이원진;이재서;이재서;이철희;권태영
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • The mucociliary system is one of the most important airway defense mechanisms in human body and impairment of ciliary movement results in various diseases in respiratory tract. In this study, we have developed a system that can measure ciliary movement in vivo and quantified ciliary beat frequency (CBF) through autoregressive (AR) power spectrum. To measure the frequency in vivo, we applied a photoelectric method that was composed of a laser light and a fiber optic probe. Scattered signals are transferred to a PC in which they are displayed on the monitor and its CBF is determined by the AR method in were acquired. For 8 normal subjects, the analyzed CBFs ranged from 5 to 10Hz and its mean was 7.3${\pm}$1.1Hz. This result showed similar aspects to the reported results of CBFs to data. We expect that this result will be applied in various clinical studies such as analysis of CBF changes by drugs or by diseaes.

  • PDF

A Development of Algorithm on Robust Adaptive Law in Adaptive mechanism showing Chaotic phenomenon (혼돈 현상을 보이는 적응기구에서의 강인한 적응법칙에 관한 알고리즘의 개발)

  • Jeon, Sang-Young;Yim, Wha-Yeong
    • Proceedings of the KIEE Conference
    • /
    • 1994.11a
    • /
    • pp.322-325
    • /
    • 1994
  • Mareel and Bitmead proved the presence of chaotic signal in random noise by applying dead beat control theory to adaptive mechanism. In this paper robust adaptive theory is proposed. With the property of chaotic signal that has order and law, the proposed theory can enhance the control Performance by applying the recursive algorithm that uses dynamic relation which have small correlation. The performance of proposed algorithm is demonstrated with the computer simulation of position control of electric motor. In this simulation, the adaptive low is adopted to control electric motor and the Presence of chaotic signal in feedback signal is proved by using several method such as time series, fourier spectrum phase portrait method.

  • PDF

Arrhythmia Classification based on Binary Coding using QRS Feature Variability (QRS 특징점 변화에 따른 바이너리 코딩 기반의 부정맥 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.8
    • /
    • pp.1947-1954
    • /
    • 2013
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. But it is difficult to detect the P and T wave signal because of person's individual difference. Therefore it is necessary to design efficient algorithm that classifies different arrhythmia in realtime and decreases computational cost by extrating minimal feature. In this paper, we propose arrhythmia detection based on binary coding using QRS feature varibility. For this purpose, we detected R wave, RR interval, QRS width from noise-free ECG signal through the preprocessing method. Also, we classified arrhythmia in realtime by converting threshold variability of feature to binary code. PVC, PAC, Normal, BBB, Paced beat classification is evaluated by using 39 record of MIT-BIH arrhythmia database. The achieved scores indicate the average of 97.18%, 94.14%, 99.83%, 92.77%, 97.48% in PVC, PAC, Normal, BBB, Paced beat classification.