• 제목/요약/키워드: Beam-splice

검색결과 66건 처리시간 0.02초

Cyclic testing of steel column-tree moment connections with various beam splice lengths

  • Lee, Kangmin;Li, Rui;Chen, Liuyi;Oh, Keunyeong;Kim, Kang-Seok
    • Steel and Composite Structures
    • /
    • 제16권2호
    • /
    • pp.221-231
    • /
    • 2014
  • The purpose of this study was to evaluate the cyclic behavior of steel column-tree moment connections used in steel moment resisting frames. These connections are composed of shop-welded stub beam-to-column connection and field bolted beam-to-beam splice. In this study, the effects of beam splice length on the seismic performance of column-tree connections were experimentally investigated. The change of the beam splice location alters the bending moment and shear force at the splice, and this may affect the seismic performance of column-tree connections. Three full-scale test specimens of column-tree connections with the splice lengths of 900 mm, 1,100 mm, and 1,300 mm were fabricated and tested. The splice lengths were roughly 1/6, 1/7, 1/8 of the beam span length of 7,500 mm, respectively. The test results showed that all the specimens successfully developed ductile behavior without brittle fracture until 5% radians story drift angle. The maximum moment resisting capacity of the specimens showed little differences. The specimen with the splice length of 1,300 mm showed better bolt slip resistance than the other specimens due to the smallest bending moment at the beam splice.

Effect of bolted splice within the plastic hinge zone on beam-to-column connection behavior

  • Vatansever, Cuneyt;Kutsal, Kutay
    • Steel and Composite Structures
    • /
    • 제28권6호
    • /
    • pp.767-778
    • /
    • 2018
  • The purpose of this study is to investigate how a fully restrained bolted beam splice affects the connection behavior as a column-tree connection in steel special moment frames under cyclic loading when located within the plastic hinge zone. The impacts of this attachment in protected zone are observed by using nonlinear finite element analyses. This type of splice connection is designed as slip-critical connection and thereby, the possible effects of slippage of the bolts due to a possible loss of pretension in the bolts are also investigated. The 3D models with solid elements that have been developed includes three types of connections which are the connection having fully restrained beam splice located in the plastic hinge location, the connection having fully restrained beam splice located out of the plastic hinge and the connection without beam splice. All connection models satisfied the requirement for the special moment frame connections providing sufficient flexural resistance, determined at column face stated in AISC 341-16. In the connection model having fully restrained beam splice located in the plastic hinge, due to the pretension loss in the bolts, the friction force on the contact surfaces is exceeded, resulting in a relative slip. The reduction in the energy dissipation capacity of the connection is observed to be insignificant. The possibility of the crack occurrence around the bolt holes closest to the column face is found to be higher for the splice connection within the protected zone.

Experimentally investigation of replaceable reduced beam section utilizing beam splice connection

  • Yasin Onuralp Ozkilic;Mehmet Bakir Bozkurt
    • Steel and Composite Structures
    • /
    • 제52권1호
    • /
    • pp.109-119
    • /
    • 2024
  • This study presents a replaceable reduced beam section (R-RBS) located at the column end in moment resisting frames (MRFs). An end of the R-RBS is connected to column by using end-plate moment connection and the other end of that is connected to main beam with beam splice connection. Therefore, the RBS that is expected to yield under an earthquake can be easily replaceable. Geometry of the RBS and the thickness of the beam splice connection are the prime variables of this study. A total of eight experimental test was carried out to examine the seismic performance of the proposed R-RBS with the connection details. The results obtained from experimental studies demonstrated that plate sizes of the beam splice connection significantly affect the seismic performance of RBSs used in MRFs.

반복재하 실험에 의한 고력볼트 철골 보 이음부의 내진거동 연구 (Cyclic Seismic Performance of High-Strength Bolted-Steel Beam Splice)

  • 이철호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1998년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Spring 1998
    • /
    • pp.57-64
    • /
    • 1998
  • This paper presents the cyclic seismic performance of slip-critically designed, high-strength bolted-beam splice in steel moment frame. Before the moment connection reaching its plastic strength, unexpected premature slippage occurred at the slip-critically designed beam splice during the test. The experimentally observed frictional coefficients were as low as about 50% to 60% of nominal (code) value. Nevertheless, the bearing type behavior mobilized after the slippage transferred the increasing cyclic loads successfully, i.e., the consequence of slippage into bearing was not catastrophic to the connection behavior. The test result seems to indicate that the traditional beam splice design basing upon (bolt-hole deducted) effective flange area criterion may not be sufficient in developing the plastic strength of moment connections under severe earthquake loading. New procedure for achieving slip-critical beam splice design is proposed based on capacity design concept.

  • PDF

A new replaceable fuse for moment resisting frames: Replaceable bolted reduced beam section connections

  • Ozkilic, Yasin O.
    • Steel and Composite Structures
    • /
    • 제35권3호
    • /
    • pp.353-370
    • /
    • 2020
  • This paper describes a new type of replaceable fuse for moment resisting frames. Column-tree connections with beam splice connections are frequently preferred in the moment resisting frames since they eliminate field welding and provide good quality. In the column-tree connections, a part of the beam is welded to the column in the shop and the rest of the beam is bolted with the splice connection in the field. In this study, a replaceable reduced beam section (R-RBS) connection is proposed in order to eliminate welding process and facilitate assembly at the site. In the proposed R-RBS connection, one end is connected by a beam splice connection to the beam and the other end is connected by a bolted end-plate connection to the column. More importantly is that the proposed R-RBS connection allows the replacement of the damaged R-RBS easily right after an earthquake. Pursuant to this goal, experimental and numerical studies have been undertaken to investigate the performance of the R-RBS connection. An experimental study on the RBS connection was used to substantiate the numerical model using ABAQUS, a commercially available finite element software. Additionally, five different finite element models were developed to conduct a parametric study. The results of the analysis were compared in terms of the moment and energy absorption capacities, PEEQ, rupture and tri-axiality indexes. The design process as well as the optimum dimensions of the R-RBS connections are presented. It was also demonstrated that the proposed R-RBS connection satisfies AISC criteria based on the nonlinear finite element analysis results.

커플러 이음 철근을 사용한 철근콘크리트 보의 휨 거동에 대한 실험적 연구 (An Experimental Research on the Flexural Behavior of Concrete Beams with Lock Joint Coupler Bars)

  • 박선규;이괄;고원준
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제4권3호
    • /
    • pp.197-204
    • /
    • 2000
  • Tensile strength (stress) of bar splice is important in the research of mechanical behavior of reinforced concrete structures-beam, column etc.- with bar splice. The purpose of this research is to evaluate the flexural behavior - deflection of beam specimens, strain of main bars - of reinforced concrete beam with Lock Joint Coupler. To make a comparative research, reinforced concrete beam specimens with normal deformed bar and lap splice are tested and analyzed. Test results, Comparing a deflection of three types flexural specimens, a flexural specimen with Lock Joint Coupler is 40% greater than the other flexural specimens. At the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 50% less, and vice versa, at the point of 14cm far from the center of flexural specimen, the strain of main bar(D29) with lock joint coupler is 9% larger than the strain of main bar(D29) which calculated using the classical flexure theory. A discords, between a deflection behavior of the flexural specimens and a strain of the main bar, are caused by the difference of strain between the lock joint coupler and main bar, near the lock joint coupler. So, additional research is need to verify as stated above discords.

  • PDF

하부철근 이음길이에 따른 PC 보 제작 길이 산정 (Estimation of production length of PC beam by using splice length of bottom rebar)

  • 성수진;임채연;김선국
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.84-85
    • /
    • 2014
  • Green frame is column-beam structure composed of precast concrete members. Based on Revision of Structural Concrete Design Code, the bottom rebar of beam shall be extend at least 150mm into the support member. However, if the bottom rebar extend to satisfy Revision of Structural Concrete Design Code, the installation fo beam is impossible due to interference between the columns and beams. Thus, the aim of this study is estimation of production length of precast concrete beam by using splice length of bottom rebar. In this study to solve this problem, lap splice were used on the join. This study was calculated length of the reinforcement by the diameter. According to the length of the rebar, the production length of beam concrete was calculated. The results of this study will satisfy the Revision of Structural Concrete Design Code about column-beam connection when green frame will be applied.

  • PDF

경사단부강판 보 이음을 갖는 강재 보-기둥 모멘트접합부의 내진실험 (Seismic Tests of Steel Beam-to-column Moment Connections with Inclined End-plate Beam Splice)

  • 임종진;김동관;이상현;박철수;이창남;엄태성
    • 한국강구조학회 논문집
    • /
    • 제29권2호
    • /
    • pp.181-192
    • /
    • 2017
  • 최근 경사단부강판과 고장력 볼트를 이용한 보 이음(Inclined end-plate beam splice) 공법이 개발되었다. 단부강판은 브래킷 단부에 용접되고 연결보는 고장력 볼트를 통해 이음시킨다. 기둥면에는 브래킷이 용접되고, 브래킷과 연결보 단부에 각각 경사단부강판과 고장력 볼트를 이용하여 이음 시킨다. 이 연구에서는 총 6개의 외부 보-기둥 모멘트접합부의 반복가력실험을 수행하였다. 실험변수는 단부강판 상세와 볼트 배열 상세이다. 모든 실험체는 AISC Design Guide 4에 따라 단부강판 및 볼트에 의한 모멘트 저항성능이 보 이음부 요구모멘트보다 크도록 설계되었다. 실험결과, 확장된 단부강판(Extended end-plate)을 사용한 보이음부의 경우 이음부 단부강판의 지레작용 및 볼트의 취성 파단 없이 중앙 보 모멘트가 단부 브래킷으로 효과적으로 전달되었다. 하지만, 보-기둥 접합부의 변형능력은 기둥면 보 플랜지 용접부의 취성파단으로 제한적이었다. 실험결과를 바탕으로, 기울어진 단부강판 이음부를 갖는 보-기둥 모멘트접합부의 내진설계를 위한 개선사항을 제안하였다.

반복재하 실험에 의한 고력볼트 철골 보 이음부의 내진거동 연구 (Cyclic Seismic Performance of High-Strength Bolted-Steel Beam Splice)

  • 이철호;박종원
    • 한국지진공학회논문집
    • /
    • 제2권4호
    • /
    • pp.115-122
    • /
    • 1998
  • 고력볼트로서 슬립이 발생치 않도록 설계된 철골모멘트골조의 보 이음부의 내진거동을 반복재하 실물대 실험을 통하여 평가하였다. 예상과는 달리 모메트 접합부가 극한 소성강도에 도달하기 훨씬 이전에 보 이음부의 슬립이 발생하였다 실험을 통하여 관측된 마찰계수는 규준 공칭값의 50-60%에 불과하였다. 그러나 보 플랜지의 열영향부가 파단에 이르기 까지 슬립 이후의 지압거동을 통하여 증가되는 반복하중을 성공적으로 모멘트접합부로 전달하였다. 즉 반복하중 하에서도 보 이음부의 슬립이 곧바로 구조적 일체성의 상실로 이어지지는 않음이 관측되었다 볼토구멍을 공제한 보 플랜지 유효단면적의 전강도에 기준한 전통적 보 이음부 설계법에 의할 경우 모멘트 접합부의 소성강도 발현 이전에 보 이음부의 슬립발생 가능성이 높다 본 연구에서는 역량설계 개념에 기초하여 강진 작용시의 보 이음부의 설계와 관련한 추가 고려사항을 제안하였다.

  • PDF

고력볼트 접합이음 철골보의 탄소성거동 (Elasto-Plastic Behavior of Steel Beams with High Strength Bolted Splices)

  • 최성모;김진호;노원경
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.531-539
    • /
    • 2003
  • 노스리지 지진 발생시 구조체 손상이 발생했던 현장용접 모멘트골조와 달리 기둥-보 브라켓형식의 모멘트골조에는 지진의 영향을 조정하고 감소시키는 도구(tool)가 바로 보에 이음부(splice)이다. 지진발생 중에 보의 이음부는 연성의 퓨즈(fuse)로서 작용할 수 있고, 골조에 발생할 수 있는 흼모멘트를 포함한 힘의 크기를 제한할 수 있다. 국내에서는 모멘트 골조의 대부분이 기둥-보 브라켓 형식으로 이루어진다. 본 논문에서는 이음하지 않은 H형강보를 제작하여 단순가력 실험을 수행하였고, 고력볼트를 이용하여 전강도설계된 실물실험체와 플랜지볼트 열수를 각각 75%, 50% 및 0%로 줄여서 이음부를 제작한 H형강 보를 단순가력 실험을 수행하였다. 이들 실험을 통해 기둥-보 브라켓형식의 모멘트 골조에서 보의 이음부(Beam Splice)가 악보(Week Beam)의 임계위치(Critical Point)로서 작용할 수 있는 가능성을 타진하고자 하는 연구에 기초자료를 제공하는 것이 본 연구의 목적이다.