• Title/Summary/Keyword: Beam spot

Search Result 285, Processing Time 0.027 seconds

The diffraction property of the bessel beam for defocus (Defous에 따른 bessel beam의 회절 특성)

  • 박성종;최기준;박민경;김재범;심상현;정창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.6 no.2
    • /
    • pp.101-107
    • /
    • 1995
  • To investigate the diffraction property of the Bessel beam for defocus which acts CFAP (Combined Filter of Amplitude and Phase), we calculated numerically the intensity, the radius of central spot, and the optical transfer function for the number of node of the Bessel beam when an optical system has an aberration-free or a spherical aberration. The Bessel beam has larger the maximum intensity and the OTF value for an optical system with a spherical aberration than that with an aberrationfree. Particularly, the OTF value at the point of maximum intensity for $W_{40}=3\lambda$is higher for the Bessel beam than for the Clear aperture. From these results, we know that the Bessel beam has the compensating effect. The Bessel beam also has the radius of central spot having a superresolution. We will useful for the fabrication of semiconductor device and the optical recording system using these effects.ffects.

  • PDF

A Calculation of the Propagation for Focused Beams Using BPM (BPM을 이용한 안테나 배열의 집속 빔 전파 해석)

  • Kim Jaeheung;Cho Choon Sik;Lee Jae W.
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.5 s.96
    • /
    • pp.465-471
    • /
    • 2005
  • A method of calculation fur propagating and focusing of focused beams generated in antenna arrays, using BPM(Beam Propagation Method), is presented in this paper. Based on the diffraction theory, the beam focusing and Propagation is studied specially for the case of the antenna way fed by the Rotman lens that is able to focus microwave power on its focal arc or generate multiple beams. There are difficulties in performing a full-wave simulation using a commercial EM simulation tool for propagating and focusing of beams because of the structural complexity and the feeding assignment of the antenna array. Therefore, as an alternative solution, the BPM is presented to calculate the beam propagation from the aperture-type antennas. From the point of view of optics, the propagations of the lens have been simplified from the Fresnel diffraction integral to the Fourier transform. Using Fourier Transform, a beam propagation method is developed to show improvement of the resolution by controlling the wavefront of wave Propagating from an aperture-type antenna array. The beam width(or spot size) and the intensity are calculated for a focused beam propagating from an array having $10\lambda$ of its size. For the beams with $20\lambda,\;30\lambda$, and $50\lambda$ of geometrical focal length, the half-power beam widths(or spot size) are about 1.1\lambda,\;1.3\lambda,\;and\;1.9\lambda$ respectively.

Nondestructive evaluation of spot weld quality using by ultrasonic measurement (초음파계측에 의한 SPOT용접품질의 비파괴평가)

  • 박익근
    • Journal of Welding and Joining
    • /
    • v.12 no.3
    • /
    • pp.109-117
    • /
    • 1994
  • Spot welding has wide used with a high work efficiency in the automotive and aerospace industries. Up to the present, the technique mainly used to test spot welds on production lines has been entirely depended upon destructive chisel or peel testing. Therefore, it's being very important assignment to secure the NDE technique which can be evaluate spot weld quality with more efficiency and high reliability. This paper discusses the feasibility of UNDE techniques to evaluate spot weld quality. For the sake of the approach to the quantitative measurement of nugget diameter and the discrimination of a the corona bond from nugget, ultrasonic c-scan image and distribution of reflective echo amplitude was measured by immersion method with the mechanical and the electronic scanning of point-focussed ultrasonic beam(25 MHz). As the results of this study, corona bond which is the most dangerous types of interface defects can be successfully detected, as well as expulsion and voids. Ultrasonic testing results were confirmed and compared by optical microscope and SAM(Scanning Acoustic Microscope) observation of the spot-weld cross section. The results show that the nugget diameter can be successfully measured with the accuracy of 0.8 mm.

  • PDF

Improvement of Statistics in Proton Beam Range Measurement by Merging Prompt Gamma Distributions: A Preliminary Study

  • Kim, Sung Hun;Park, Jong Hoon;Ku, Youngmo;Lee, Hyun Su;Kim, Young-su;Kim, Chan Hyeong;Jeong, Jong Hwi
    • Journal of Radiation Protection and Research
    • /
    • v.44 no.1
    • /
    • pp.1-7
    • /
    • 2019
  • Background: To monitor proton beam in proton therapy, prompt gamma imaging systems are being developed by several research groups, and these systems are expected to improve the quality of the treatment and the patient safety. To apply the prompt gamma imaging systems into spot scanning proton therapy, the systems should be able to monitor the proton beam range of a spot with a small number of protons ( <$10^8$ protons), which is quite often not the case due to insufficient prompt gamma statistics. Materials and Methods: In the present study, we propose to improve prompt gamma statistics by merging the prompt gamma distributions of several individual spots into a new distribution. This proposal was tested by Geant4 Monte Carlo simulations for a multi-slit prompt gamma camera which has been developed to measure the proton beam range in the patient. Results and Discussion: The results show that the proposed method clearly enhance the statistical precision of beam range measurement. The accuracy of beam range verification is improved, within ~1.4 mm error, which is not achievable before applying the developed method. Conclusion: In this study, we tried to improve the statistics of the prompt gamma statistics by merging the prompt gamma distributions of multiple spots, and it was found that the merged distribution provided sufficient prompt gamma statistics and the proton beam range was determined accurately.

Study on a Optical Storage Device Based on Multi-beam (다중빔을 이용한 광 저장 장치에 관한 연구)

  • Lee, Jeong-Hyeon;Han, Chang-Su;Kim, Su-Hyeon;Gwak, Yun-Geun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.4 s.97
    • /
    • pp.64-70
    • /
    • 1999
  • A new multi-beam optical system is presented on the grounds of tri-positioning systems in this paper. The system has been developed to improve the data transfer rate for the optical disk system. The actuating system is composed of a tracking and focusing actuating system basically and a newly developed beam rotating actuator. The beam rotating actuator is employed in a multi-beam optical system to trace more than one track simultaneously. The multi-beam optics is established through the optical simulation and several experimental trials. The differential phase tracking method is used in the tracking error signal detection based on the only one beam spot. We also analyze the characteristics of multi-beam optical system. The experimental result shows that the multi-beam positioning system has performance adequate to the multi-beam optical disk system.

  • PDF

Buried Channel PMOS에서 이온 주입된 $BF_2$ 열처리 거동

  • Heo, Tae-Hun;No, Jae-Sang
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.374-374
    • /
    • 2012
  • 반도체 소자의 크기가 100 nm 이하로 감소되면 통상적인 이온 주입 조건인 이온 에너지, 조사량 및 이온 주입 각도뿐만 아니라 Dose Rate 및 모재 온도가 Dopant Profile을 조절하는 데에 있어서 매우 중요한 인자로 작용한다. 본 연구에서는 Ribbon-beam 및 Spot-beam을 사용하여 활성화 열처리 후 Dopant Profile을 분석하였다. 이온 주입은 모든 시편에서 $BF_2$를 가속 에너지 10 keV 및 조사량 $2{\times}10^{15}/cm^2$로 고정하였다. 이온 주입 후 도펀트 활성화는 100% 질소 분위기 하에서 $850^{\circ}C$-30s 조건으로 RTA 열처리를 수행하였다. Boron 및 Fluorine의 Profile은 SIMS 분석을 통하여 구하였다. Spot-beam은 Ribbon-Beam에 비하여 Dose Rate 및 Cooling Efficiency가 높기 때문에 이온 주입 후 더욱 많은 양의 Primary-defect를 발생시키고 이에 따라 두꺼운 비정질 충을 형성한다. $BF_2$ 이온 주입 된 시편에서 B 및 F의 농도 Peak-height는 a/c 계면에 위치하는 것을 관찰하였다. 또한 B 및 F의 농도 Peak-height는 Silicon 모재의 온도가 증가할수록 증가하는 것을 관찰하였다. Silicon 모재의 온도가 증가함에 따라 Active-area의 면저항이 변화하지 않는 상태에서 Vt (Threshold Voltage)가 급격히 감소함을 관찰 하였다. 비정칠 층의 두께가 증가할수록 a/c 계면 하단에 잔존하는 Residual-defect의 양이 감소하고 이는 측면확산을 감소시키는 역할을 한다는 것이 관찰되었다.

  • PDF

Centralized mmWave-Based Multi-Spot Beam Cellular System (중앙 집중형 밀리미터파 기반 다중 스팟 빔 셀룰러 시스템)

  • Park, Soon-gi;Choi, Yong-seouk;Kim, Tae-joong
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.3
    • /
    • pp.285-297
    • /
    • 2016
  • In this paper, a centralized mmWave-based multi-spot beam cellular system architecture having such a base station equipped with a plurality of beam-forming antennas, multi-layered dynamic cell configuration method as one of key concepts of this system operation and a mobility management method based on it are introduced. To estimate the performance of new system, system simulation was performed under the ideal environment without blockage. These results show the possibility that system capacity can be dramatically increased and mobility performance similar to the existing cellular system may be achieved.

Piezoelectric Beam Rotating Actuator for Multiple Beam Disk Drives (압전소자률 이용한 다중빔 광디스크용 빔 회전 구동기)

  • 김병준;김수현;곽윤근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.5
    • /
    • pp.154-159
    • /
    • 2000
  • A multi-beam optical disk drive is presented as a method for improving the effective data transfer rate by increasing the beam spot number formed on an optical disk. The beam rotating actuator is necessary for putting multi-beam on more than one track. The beam rotating actuator is made up of piezoelectric material, high stiffness wire hinge and dove prism. The actuator has good frequency response above 1KHz and suitable operational range. The dynamic equation for the actuator is derived.

  • PDF

High power CO$_{2}$laser beam welding of ASIA 316 stainless steel

  • 김재도;조용무
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.321-327
    • /
    • 1991
  • High power laser beams are used in a wide variety of materials processing applications such as cutting, welding, drilling and surface treatment. The CO$\sub$2/ laser is increasingly used in laser beam welding because of the highly potential advantages. High power laser welding is a high energy density, no filler metals and low heat input process to join metals. As the comparison with the conventiona welding, precision work and good fit-up to join the metals are required and maintenance is expensive at present. The principal variables of laser beam welding are the laser beam power, travel speed and bean spot size. The penetration depth during laser beam welding is directly related to the power density of the laser beam. Generally, for a constant beam size, the penetration depth increases with increasing laser beam power.