• 제목/요약/키워드: Beam size

검색결과 1,720건 처리시간 0.035초

Red-green-blue Beam Combiner Based on Two-mode Interference

  • Chung, Youngchul
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.22-26
    • /
    • 2019
  • A compact red-green-blue beam combiner (multiplexer) based on two-mode interference (TMI) is proposed and its feasibility is shown through three-dimensional beam propagation simulation. The first stage TMI beam combiner makes red (637 nm) and blue (446 nm) beams combined toward one output port and the second stage one combines red, blue, and green (532 nm) beams. The power transmission to the output port from the red, green, and blue input ports are 0.96, 0.99, and 0.98, respectively. When the wavelength deviation is 10 nm, the transmission is maintained to be larger than 0.9. The size of the combiner is as tiny as $0.02{\times}3.8mm^2$.

Time Resolced Molecular Beam Characteristic in a Pulsed Supersonic Jet

  • 강위경;김은정;최창주;정광우;정경훈
    • Bulletin of the Korean Chemical Society
    • /
    • 제16권3호
    • /
    • pp.238-243
    • /
    • 1995
  • A pulsed molecular beam source having short pulse duration (typically 70 ${\mu}s)$ and narrow velocity distribution (${\Delta}$v/v=8% for helium) has been costructed utilizing a commercial fuel injector. Beam characteristics of helium and ammonia seeded in helium expansions are accomplished by the use of an electron impact time-or-flight mass spectrometer. The comparisons between experimental data and theoretical calculations show that the proper beam speed is important to predict the evolution of stream temperature and valve shutter function. The decreasing tendency of pulse duration with increasing cluster size leads to the conclusion that the cluster beam property is described as a function of cluster mass and disinct cluster temperature.

새우조망 어구의 막대 (빔)와 날개그물 길이에 따른 어획성능과 양망 작업에의 영향 (Catching efficiency of a shrimp beam trawl according to the length of beam and wing net and its influence on the hauling work)

  • 박해훈
    • 수산해양기술연구
    • /
    • 제50권3호
    • /
    • pp.396-406
    • /
    • 2014
  • Shrimp beam trawl fishery is one of the important coastal fisheries in Korea. It has a regulation to the length of beam (8m) and wing net (7m) of shrimp beam trawl that has been used in the district of Junlanam-do and Gyungsangnam-do. This regulation was made in relation to the size of shrimp beam trawler of 3-ton class at that time. Now the shrimp beam fishing vessel has a limit not greater than 5 tons in gross ton. Recently, with improvement of fishing industry and fishing vessel fishermen asked the expansion of the length of beam and wing net, therefore it is necessary to investigate the effect of lengthening the beam and wing net length. Three different beams (8m, 10m and 12m in length) and three different wing net (7m, 10m and 13m in length) were made and the experiment was conducted near Narodo of Goheng by two fishing vessels of 4.98 and 4.88 tons in gross ton between June 2011 and October 2012. When the length of wing net was increased from 7m to 10m and 13m, the relative catch ratio in total biomass was increased 25% and 79% for shrimp, (17% and 22% in total), respectively. And when the beam length was increased from 8m to 10m and 12m, the relative catch ratio was increased 35% and 84% for shrimp, (21% and 37% in total), respectively. The force exerted to the iron guide of inhauler's with the beam length of 8m was about 30% greater than that with the beam length of 10m when hauling the shrimp beam trawl net.

양성자 치료 시 사용되는 Compensator의 Thickness에 대한 적정성 평가 (Assessment of Compensator Thickness in Proton Therapy)

  • 박용수;장준영;조광현;박용철;최병기
    • 대한방사선치료학회지
    • /
    • 제30권1_2호
    • /
    • pp.35-40
    • /
    • 2018
  • 목 적 : 본원에서 사용하는 양성자 에너지는 크기에 따라 도달거리가 달라지며, Compensator는 Distal 두께에 따라 Energy의 크기를 다르게 할 수 있으며 이로 인해 Dose rate이 변화된다. 따라서 Compensator distal의 두께를 변화시키면서 Dose 분포 및 Beam on time에 대한 영향을 평가해보고자 한다. 대상 및 방법 : 본원에서 양성자치료를 받은 에너지가 낮은 환자 5명을 대상으로 실험하였다. 선택된 환자들의 기존 치료 시 Beam on time을 확인하였으며 이 후 양성자치료계획시스템(TPS)을 통하여 Compensator의 Distal 두께를 기존 두께에서 2 cm씩 최대 14 cm까지 증가시켜가며 치료계획을 비교 평가하였다. Dose 분포를 평가하기 위하여 Target의 Conformity Index(CI)값과 Homogeneity Index(HI)값, Target 후면부의 Organ at risk(OAR)의 최대선량을 비교하였으며 치료시간에 대한 영향을 평가하고자 Compensator Distal 두께 별로 제작하여 Beam on time을 비교하여 평가하였다. 결 과 : Compensator의 Distal 두께를 증가시켜 Homogeneity Index, Conformity Index를 분석한 결과 모든 환자에서 동일한 수치가 나왔다. Target 후면부의 OAR을 비교한 결과 Abdomen의 Spine cord에 최대 7 cGy, Eyeball의 RT Lens에서 88 cGy, Nasal cavity의 RT Lens에 391 cGy, Mediastinum의 Trachea에 51 cGy, Pelvis의 Small bowl에 661 cGy 증가하였다. Beam on time을 비교한 결과 Abdomen의 경우 기존 126초에서 최대 62초, Eyeball의 경우 105초에서 37초, Nasal cavity의 경우 기존 187초에서 134초, Mediastinum의 경우 기존 100초에서 40초, Pelvis의 경우 기존 440초에서 118초로 감소하였다. 결 론 : 연구결과 Compensator의 distal 두께가 두꺼워질수록 에너지의 크기를 증가시킬 수 있으며 Dose rate이 증가하여 Beam on time이 감소하는 효과가 있었다. 이는 Beam on time이 많이 소요되는 호흡동조치료를 요하는 Liver, 마취를 하는 소아환자에게 적용한다면 치료시간 단축과 환자의 편의성 면에서 큰 도움을 줄 것으로 평가된다. 하지만 에너지의 크기가 증가할수록 Distal penumbra가 증가하기 때문에 Target 후면부에 OAR이 인접해 있는 경우는 양성자치료계획 시 Penumbra의 영향을 고려한 적절한 Compensator 두께를 설정할 필요가 있을 것으로 사료된다.

  • PDF

Influence of voxel size on cone-beam computed tomography-based detection of vertical root fractures in the presence of intracanal metallic posts

  • Yamamoto-Silva, Fernanda Paula;de Oliveira Siqueira, Claudeir Felipe;Silva, Maria Alves Garcia Santos;Fonseca, Rodrigo Borges;Santos, Ananda Amaral;Estrela, Carlos;de Freitas Silva, Brunno Santos
    • Imaging Science in Dentistry
    • /
    • 제48권3호
    • /
    • pp.177-184
    • /
    • 2018
  • Purpose: This study was performed to evaluate the influence of voxel size and the accuracy of 2 cone-beam computed tomography (CBCT) systems in the detection of vertical root fracture (VRF) in the presence of intracanal metallic posts. Materials and Methods: Thirty uniradicular extracted human teeth were selected and randomly divided into 2 groups(VRF group, n=15; and control group, n=15). The VRFs were induced by an Instron machine, and metallic posts were placed in both groups. The scans were acquired by CBCT with 4 different voxel sizes: 0.1 mm and 0.16 mm (for the Eagle 3D V-Beam system) and 0.125 mm and 0.2 mm (for the i-CAT system) (protocols 1, 2, 3, and 4, respectively). Interobserver and intraobserver agreement was assessed using the Cohen kappa test. Sensitivity and specificity were evaluated and receiver operating characteristic analysis was performed. Results: The intraobserver coefficients indicated good (0.71) to very good (0.83) agreement, and the interobserver coefficients indicated moderate (0.57) to very good (0.80) agreement. In respect to the relationship between sensitivity and specificity, a statistically significant difference was found between protocols 1 (positive predictive value: 0.710, negative predictive value: 0.724) and 3 (positive predictive value: 0.727, negative predictive value: 0.632) (P<.05). The least interference due to artifact formation was observed using protocol 2. Conclusion: Protocols with a smaller voxel size and field of view seemed to favor the detection of VRF in teeth with intracanal metallic posts.

Gradient based algorithm을 이용한 multiple slice IMRT optimization (IMRT optimization on multiple slice using gradient based algorithm)

  • 이병용;조병철;이석;정원균;안승도;최은경;김종훈;장혜숙
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.201-206
    • /
    • 1998
  • 세기변조방사선치료 (Intensity Modulation Radiation Therapy; IMRT) 의 치료계획 목적으로 사용하기 위한 선량최적화 방법을 Gradient based algorithm을 이용하여 개발하였다. 환자의 치료 관심 부위를 포함하는 약 10-30 CT 단면에 대하여 각 단면 별로 선량최적화를 실시하였고, 장기별로 최대 허용선량을 지정하였으며, 표적의 선량은 100$\pm$5 %로 제한하였다. beamlet의 크기는 8$\times$8 $cm^2$으로 제한하였고, beam size가 크지 않으므로 beam diverge는 고려하지 않았다. beamlet 하나가 만드는 선량분포를 미리 계산한 후, 선량중첩방식으로 전체 선량분포를 계산하였다. 고정된 동일평면에 대하여 5방향에서 입사하는 빔에 대한 최적화를 실시하였으며, 그 효용성을 비교하기 위해, 1, 3, 5, 7, 9 방향에 입사하는 빔과 최적화지수를 구하였다. 선량최적화에 소요되는 시간은 대체로 slice 수에 비례하였으며, 계산시간과 최적화지수를 비교할 때 빔의 개수가 3-7개 일 때 가장 적합하였다. 다중단면에 대한 선량최적화를 beam divergence를 고려하지 않을 때, 단일 단면에 대한 선량최적화를 반복 시행함으로써 얻을 수 있었다. 선량최적화의 결과가 선량중심의 위치에 따라 민감하게 변하는 경우가 발생하였으며, 이를 개선하기 위해서는 선량중심의 최적화가 개발될 필요성이 있었다.

  • PDF

소조사면 전량분포의 특성에 관한 고찰 (Study on the beam properties of small field sizes)

  • 조정희;이상규;안승권;박재일
    • 대한방사선치료학회지
    • /
    • 제16권1호
    • /
    • pp.1-9
    • /
    • 2004
  • 목적 : 본 연구의 목적은 소조사면의 선량특성을 측정하며 콜리메이터의 위치에 따른 반음영의 변화와 중심선량의 분포양상을 측정하며 측외측정선량점의 변화에 따른 선량분포의 특성을 측정하여 최근 대두되고 있는 소조사면 방사선치료에 유용한 정보를 제공하는데 그 목적이 있다. 대상 및 방법 : 지멘스의 Primart 선형가속기의 6MV에너지를 이용하였으며 측정은 Farmer chamber와 Pinpoint chamber를 이용하여 심부선량율과 beam profile, 중심출력선량의 변화를 측정하였다. 중심선속의 변화에 따른 에너지의 특성과 반음영의 변화를 외측으로 2cm 간격으로 측정하였다. 측정은 $1{\times}1cm,\;3{\times}3cm,\;5{\times}5cm,\;10{\times}10cm$에서 측정하였으며 결과는 표준조건하의 측정값과 비교, 분석하였다. 결과 : Farmer chamber와 Pinpoint chamber를 이용해 $1{\times}1cm$, 10cm깊이에서 측정한 결과 두 측정기간에 소조사면에서는 $30\%$ 이상의 차이를 보였으며 조사면의 크기가 증가함에 따라 두 측정기간의 차이는 급격히 감소했다. 측외측정점의 변화에 따른 선량분포는 큰 차이가 없었으나 조사야의 크기가 감소함에 따라 $1{\times}1cm$에서는 약 $13\%$의 차이를 보여 조사야 크기에 따른 변화가 큰 것으로 측정되었다. 전체조사면에서 반음영이 차지하는 비율도 조사면이 적어짐에 따라 높게 나타났으며 $1{\times}1cm$의 조사면에서는 약 $50\%$가 반음영이 점유하는 것으로 측정되었다. 결론 : 세기조절방사선 치료를 위해서는 각기 다른 에너지 분포를 갖는 여러 각도에서 다수의 조사면를 필요로 하며 여러 복잡한 인자들이 관여하게 된다. 여러 인자들 중에서도 콜리메이터의 형태 및 위치에 따른 출력선량의 변화 양상을 정확히 측정하는 것은 매우 중요하다. 실험결과에서도 알 수 있듯이 측정깊이와 조사면의 크기 및 측정기의 종류에 따른 측정값의 변화가 매우 크게 나타나므로 양질의 세기조절방사선 치료를 제공하기 위해서는 특히 소조사면의 선량분포에 대한 특성을 정확히 측정하는 것이 매우 중요하다.

  • PDF

H-beam 로봇 절단용 3차원 시뮬레이터의 개발과 이를 이용한 절단 최적화에 관한 연구 (A Study on Development of 3-D Simulator for H-Beam Robot Cutting and Optimization of Cutting Using the Simulator)

  • 박주용;김용욱
    • Journal of Welding and Joining
    • /
    • 제30권4호
    • /
    • pp.44-48
    • /
    • 2012
  • H-beam used for stiffening the upper structure of ocean plant is cut in the various shapes. The cutting process of the H-beam is done manually and requires a long time and high cost. Therefore, automation of H-beam cutting is an important task. This research aims to develop a 3-D simulator to build the automatic H-beam cutting system and to determine the optimal cutting method. The automatic H-beam cutting system composes of 6 robots including 2 cutting robots hang to a crane and 1 conveyer. The appropriate system layout for covering the various sizes and types of H-beam was tested and determined using the simulator. The H-beam cutting system uses a hybrid type of plasma and gas cutting because of special cutting shapes of H-beam. The cutting area of each cutting method should be properly divided according to the size and shape of H-beam to shorten the total cutting time. Additionally the collision between a robot and a robot or a robot and H-beam should be avoided. The optimal cutting method for the shortest cutting time without the collision could be found for the various cutting conditions by use of the simulator. 2 simulation samples shows the availability of the simulator to find the optimal cutting method.