• Title/Summary/Keyword: Beam profile

Search Result 469, Processing Time 0.035 seconds

Development of a Ranging Inspection Technique in a Sodium-cooled Fast Reactor Using a Plate-type Ultrasonic Waveguide Sensor (판형 웨이브가이드 초음파 센서를 이용한 소듐냉각고속로 원격주사 검사기법 개발)

  • Kim, Hoe Woong;Kim, Sang Hwal;Han, Jae Won;Joo, Young Sang;Park, Chang Gyu;Kim, Jong Bum
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.1
    • /
    • pp.48-57
    • /
    • 2015
  • In a sodium-cooled fast reactor, which is a Generation-IV reactor, refueling is conducted by rotating, but not opening, the reactor head to prevent a reaction between the sodium, water and air. Therefore, an inspection technique that checks for the presence of any obstacles between the reactor core and the upper internal structure, which could disturb the rotation of the reactor head, is essential prior to the refueling of a sodium-cooled fast reactor. To this end, an ultrasound-based inspection technique should be employed because the opacity of the sodium prevents conventional optical inspection techniques from being applied to the monitoring of obstacles. In this study, a ranging inspection technique using a plate-type ultrasonic waveguide sensor was developed to monitor the presence of any obstacles between the reactor core and the upper internal structure in the opaque sodium. Because the waveguide sensor installs an ultrasonic transducer in a relatively cold region and transmits the ultrasonic waves into the hot radioactive liquid sodium through a long waveguide, it offers better reliability and is less susceptible to thermal or radiation damage. A 10 m horizontal beam waveguide sensor capable of radiating an ultrasonic wave horizontally was developed, and beam profile measurements and basic experiments were carried out to investigate the characteristics of the developed sensor. The beam width and propagation distance of the ultrasonic wave radiated from the sensor were assessed based on the experimental results. Finally, a feasibility test using cylindrical targets (corresponding to the shape of possible obstacles) was also conducted to evaluate the applicability of the developed ranging inspection technique to actual applications.

Development of Two-dimensional Prompt-gamma Measurement System for Verification of Proton Dose Distribution (이차원 양성자 선량 분포 확인을 위한 즉발감마선 이차원분포 측정 장치 개발)

  • Park, Jong Hoon;Lee, Han Rim;Kim, Chan Hyeong;Kim, Sung Hun;Kim, Seonghoon;Lee, Se Byeong
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.42-51
    • /
    • 2015
  • In proton therapy, verification of proton dose distribution is important to treat cancer precisely and to enhance patients' safety. To verify proton dose distribution, in a previous study, our team incorporated a vertically-aligned one-dimensional array detection system. We measured 2D prompt-gamma distribution moving the developed detection system in the longitudinal direction and verified similarity between 2D prompt-gamma distribution and 2D proton dose distribution. In the present, we have developed two-dimension prompt-gamma measurement system consisted of a 2D parallel-hole collimator, 2D array-type NaI(Tl) scintillators, and multi-anode PMT (MA-PMT) to measure 2D prompt-gamma distribution in real time. The developed measurement system was tested with $^{22}Na$ (0.511 and 1.275 MeV) and $^{137}Cs$ (0.662 MeV) gamma sources, and the energy resolutions of 0.511, 0.662 and 1.275 MeV were $10.9%{\pm}0.23p%$, $9.8%{\pm}0.18p%$ and $6.4%{\pm}0.24p%$, respectively. Further, the energy resolution of the high gamma energy (3.416 MeV) of double escape peak from Am-Be source was $11.4%{\pm}3.6p%$. To estimate the performance of the developed measurement system, we measured 2D prompt-gamma distribution generated by PMMA phantom irradiated with 45 MeV proton beam of 0.5 nA. As a result of comparing a EBT film result, 2D prompt-gamma distribution measured for $9{\times}10^9$ protons is similar to 2D proton dose distribution. In addition, the 45 MeV estimated beam range by profile distribution of 2D prompt gamma distribution was $17.0{\pm}0.4mm$ and was intimately related with the proton beam range of 17.4 mm.

Quality Assurance for Intensity Modulated Radiation Therapy (세기조절방사선치료(Intensity Modulated Radiation Therapy; IMRT)의 정도보증(Quality Assurance))

  • Cho Byung Chul;Park Suk Won;Oh Do Hoon;Bae Hoonsik
    • Radiation Oncology Journal
    • /
    • v.19 no.3
    • /
    • pp.275-286
    • /
    • 2001
  • Purpose : To setup procedures of quality assurance (OA) for implementing intensity modulated radiation therapy (IMRT) clinically, report OA procedures peformed for one patient with prostate cancer. Materials and methods : $P^3IMRT$ (ADAC) and linear accelerator (Siemens) with multileaf collimator are used to implement IMRT. At first, the positional accuracy, reproducibility of MLC, and leaf transmission factor were evaluated. RTP commissioning was peformed again to consider small field effect. After RTP recommissioning, a test plan of a C-shaped PTV was made using 9 intensity modulated beams, and the calculated isocenter dose was compared with the measured one in solid water phantom. As a patient-specific IMRT QA, one patient with prostate cancer was planned using 6 beams of total 74 segmented fields. The same beams were used to recalculate dose in a solid water phantom. Dose of these beams were measured with a 0.015 cc micro-ionization chamber, a diode detector, films, and an array detector and compared with calculated one. Results : The positioning accuracy of MLC was about 1 mm, and the reproducibility was around 0.5 mm. For leaf transmission factor for 10 MV photon beams, interleaf leakage was measured $1.9\%$ and midleaf leakage $0.9\%$ relative to $10\times\;cm^2$ open filed. Penumbra measured with film, diode detector, microionization chamber, and conventional 0.125 cc chamber showed that $80\~20\%$ penumbra width measured with a 0.125 cc chamber was 2 mm larger than that of film, which means a 0.125 cc ionization chamber was unacceptable for measuring small field such like 0.5 cm beamlet. After RTP recommissioning, the discrepancy between the measured and calculated dose profile for a small field of $1\times1\;cm^2$ size was less than $2\%$. The isocenter dose of the test plan of C-shaped PTV was measured two times with micro-ionization chamber in solid phantom showed that the errors upto $12\%$ for individual beam, but total dose delivered were agreed with the calculated within $2\%$. The transverse dose distribution measured with EC-L film was agreed with the calculated one in general. The isocenter dose for the patient measured in solid phantom was agreed within $1.5\%$. On-axis dose profiles of each individual beam at the position of the central leaf measured with film and array detector were found that at out-of-the-field region, the calculated dose underestimates about $2\%$, at inside-the-field the measured one was agreed within $3\%$, except some position. Conclusion : It is necessary more tight quality control of MLC for IMRT relative to conventional large field treatment and to develop QA procedures to check intensity pattern more efficiently. At the conclusion, we did setup an appropriate QA procedures for IMRT by a series of verifications including the measurement of absolute dose at the isocenter with a micro-ionization chamber, film dosimetry for verifying intensity pattern, and another measurement with an array detector for comparing off-axis dose profile.

  • PDF

Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

  • Ashamalla, Hani;Tejwani, Ajay;Parameritis, Ioannis;Swamy, Uma;Luo, Pei Ching;Guirguis, Adel;Lavaf, Amir
    • Radiation Oncology Journal
    • /
    • v.31 no.2
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods: Sixteen patients were studied. Prostate ($PTV_P$), right pelvic ($PTV_{RtLN}$) and left pelvic lymph nodes ($PTV_{LtLN}$), and organs at risk were contoured. $PTV_P$, $PTV_{RtLN}$, and $PTV_{LtLN}$ received 50.40 Gy followed by a boost to $PTV_B$ of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose ($D_{MEAN}$) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results: Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The $D_{MEAN}$ of bladder was within 2% of each other. The rectum $D_{MEAN}$ in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion: For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

A Study on the Behavior of the Free Space Scatter dose in X-ray Diagnostic Room (X선촬영실 내에서의 공간산란선량 변동에 관한 연구)

  • Oh, Hyun-Joo;Kim, Sung-Soo;Kim, Young-Il;Lim, Han-Young;Kim, Heung-Tae;Lee, Who-Min;Kim, Hak-Sung;Lee, Sang-Suk
    • Journal of radiological science and technology
    • /
    • v.17 no.2
    • /
    • pp.21-27
    • /
    • 1994
  • In this pauper, when the X-ray exposure condition is 70, 90, 110 kV, 10 mAs, FFD 180 cm, FSO $10{\times}10$, $35{\times}35\;cm$, toward the $36{\times}36{\times}15\;cm$ acryl phantom, the free space scatter dose rate at the 15th points in X-ray diagnostic room was measured by electrometer and 1800 co ionization chamber. Therefore, the free space scatter dose distribution profile was drown, and then, the free space scatter dose contribution percentage was Investigated. The obtained results are summarized as following. 1. The X-ray tube leakage dose rate of the experiment generator at the 1 m from focus was measured maximum 85 mR/hr, minimum 20 mR/hr, therefore, this values was appeared below the KS rules, 2. The free space scatter dose become to larger at the primary X-ray beam around area, and lower at the back ward X-ray tube. The maximum values were 3,812 mR/hr at the front Lt 1 m $45^{\circ}$ point, minimum 117 mR/hr at the back ward 1 m $180^{\circ}C$ point. 3. As the more tube voltage and field size increase, the more free space scatter dose contribution percentage become to increase, as to 90 kV from 70 kV, increase to 12 %, to 110 kV from 90 kV, increase to 18 %, and then, become to 11 % at the $10{\times}10\;cm$ and 87 % at the $35{\times}35\;cm$. 4. The 89 % of the total producted scatter ray occured from acryl phantom, at the X-ray tube housing 6 %, at the front side back wall 5 %. 5. The free space scatter dose contribution percentage at the one point build up 80 % from the phanton direction, 14 % from the X-ray tube and collimator direction, 2.2 % from the front wall, 1.8 % from the side wall, 1.7 % the back wall.

  • PDF

A study on monitoring the inner structure of dam body using high resolution seismic reflection method (고분해능 탄성파 반사법을 이용한 댐체 내부구조 모니터링 연구)

  • Kim Jungyul;Kim Hyoungsoo;Oh Seokhoon;Kim Yoosung
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2005.05a
    • /
    • pp.15-20
    • /
    • 2005
  • Defects of dam body which can be induced in seepage or leakage procedure can directly affect dam safety. Therefore, a proper inspection method should be carried out in the first place to find out their positions and sizes, After that, some reinforcement works such as grouting and the corresponding assessment could be taken in a proper way. The dam(center core type earth dam) issued in this study has been in need for intensive diagnosis and reinforcement work, because a lot of slumps similar to cracks, seepage and some boggy area have been observed on the downstream slope. High resolution seismic reflection method was performed on the crest profile twice before and after grouting work(Aug. 2001 and Nov. 2004) aimed at the dam inspection and the assessment of grouting efficiency as well. To enhance the data resolution, P-beam energy radiation technique which can reduce the surface waves and hence to reinforce the reflection events was used. Strong reflection events were recognized in the stack section before grouting work, It seems that the events would be caused by e.g. horizontal cracks with a considerable aperture, Meanwhile such strong reflection events were not observed in the section after grouting. That is, the grouting work was dear able to reinforce the defects of dam body. Hence, the section showed an well arranged picture of dam inner structure. In this sense, seismic reflection method will be a desirable technique for dam inspection and for monitoring dam inner structure as well.

  • PDF

Modified Fold Type Helicone Reflector for Efficient Satellite TT&C Having Variable Coverage Area (가변 커버리지를 갖는 위성 관제용 접이식 헬리콘 반사체 안테나 성능 연구)

  • Lee, Sang-Min;Lee, Woo-Kyung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.9
    • /
    • pp.914-923
    • /
    • 2009
  • Helix antennas have been widely applied to satellite TT&C, data communication and GPS receiver systems onboard military, remote sensing and communication purpose satellites. The helix antennas are known to be convenient to control impedance and radiation coverage characteristics with a maximum directivity in satellite z-axis. Waveguide horn is commonly used for radar system that needs ultra-wideband pulse for exploration ground radar and electromagnetic disability measurement etc. It has high efficiency and low reflection characteristics provided by the low-profile shape and suppressed radiation distortion. In this paper, a waveguide horn structure incorporated with helix antenna design is proposed for satellite applications that require ultra-wideband pulse radar and high rate RF data communication link to ground station over wide coverage area. The main design concern is to synthesize variable beam forming pattern based on modified horn-helix combination helicone structure such that multi-mission antenna is implemented applicable for TT&C, earth observation, high data rate transmission. Waveguide horn helps to reduce the overall antenna structure size by introduction fold type reflector connected to the tapered helix antenna. The next generation KOMPSAT satellite currently under development requires high-performance precision attitude control system. We present an initial design of a hybrid hern-helix antenna structure suitable for efficient RF communication module design of multi-purpose satellite systems.

Optical Microphone Incorporating a Reflective Micromirror and a Dual-core Collimator (반사형 마이크로미러와 듀얼 코어 클리메이터를 이용한 광 마이크로폰)

  • Song, Ju-Han;Kim, Do-Hwan;Gu, Hyun-Mo;Park, Hyun-Jung;Lee, Sang-Shin;Cho, Il-Joo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.94-98
    • /
    • 2006
  • An optical microphone based on a dual-core fiber collimator and a membrane type micromirror serving as an optical head and a reflective diaphragm respectively was implemented. The micromirror diaphragm is suspended by a thin silicon bar linked with a frame, thus it is subject to a displacement induced by acoustic waves. The optical head incorporating two collimators integrated in a single housing gives light to and receives it from the diaphragm, rendering the optical microphone structure simple and compact. This dual-core collimator having a slowing varying beam profile facilitates the initial alignment of the optical head with the diaphragm, especially the distance between them. For the assembled microphone, the static characteristics were investigated tofind the operation point defined as the optimum distance between the head and the diaphragm, and a frequency response with a variation of about $\pm$5 dB for the range of up to 3kHz was achieved.

Design and Analysis of Square Beam Type Piezo-electric Vibrating Gyroscope (압전세락믹을 이용한 사각보형 진동자이로의 설계, 제작 및 평가)

  • 이정훈;박규연;이종원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.282-286
    • /
    • 1995
  • 일반적으로 관성계 내의 물체에 대한 동적특성의 파악을 위해서는 속도, 가속도 및 각속도, 각가속도에 대한 정보를 필요로 하며 자이로는 이중에서 각속도를 측정하는 장치이다. 운동하는 질량에 회전각속도가 인가될 때 발생되는 코리올리힘을 측정하여 회전각속도를 검출하는 개념의 각속도 센서인 진동자이로는 성능이 회전형 자이로에 비해 떨어지나 구조가 간단하고 소형이며 대량생산이 가능한 장점이 있다. 진동자이로의 효시로는 1950년 영국의 Sperry Gyroscope Company의 "Gyroton"이며, 전자기력을 이용한 가진과 측정이 그 특징으로서 실험실 조건에서 지구의 자전속도를 측정할 수 있었다. 그후 1960년대에 General Electric에서 "VYRO"라는 모델을 개발했는데 압전소자를 이용하여 가진과 측정을 하는 방법이 사용되었다. 1980년대에 Watson Ind., Soderkvist등은 센서자체가 압전물질로 만들어진 자이로를 실험하였고 1990년도에 들어서는 진동자이로의 원리를 마이크로 머시닝 기술과 연계시켜서 소형 경량화와 대량생산을 목표로 연구가 일부 진행되고 있다. 현재 제품화되어 실제 응용되고 있는 예로는 무라다사의 삼각프리즘 형태의 자이로, 토킨사의 원통형 자이로 등이 있으며 이러한 자이로는 캠코더 화면의 안정화 장치에 주로 사용되고 있다. 본 논문에서는 압전소자의 압전, 전왜 방정식으로 출발하여 자이로헤드의 동적 거동을 해석하였다. 진동자이로는 물체의 공진주파수에서의 진동현상을 이용하며, 두 방향의 고유진동수를 일치시켜야 하는 등의 설계조건이 있다. 이러한 조건을 만족하도록 사각보 구조를 기본으로 하여 새로운 형태의 자이로헤드를 고안하였다. 자이로헤드의 구동회로를 설계, 해석하고 각속도를 측정할 수 있는 검출회로를 설계하여 설계된 진동자이로의 동적 특성을 확인하고 보정회로를 이용하여 사용 주파수 영역을 넓혔다.이용하여 사용 주파수 영역을 넓혔다.러한 강이성들이 보장되는 제어이론들 중 H$_{\infty}$ 제어이론이 많이 연구/응용 되고 있다. 특히 공칭 플랜트 모델과 함께 사용되는 플랜트 모델과 함께 사용되는 플랜트 불확실성 모델은 직접적으로 성능 및 안정도에 영향을 미치므로 주의 깊게 선정해야 한다. 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection fie이 and the maximum relaxivity value. The results shows a fluences on both inflection field and the

  • PDF

Surface Characteristics of Type II Anodized Ti-6Al-4V Alloy for Biomedical Applications

  • Lee, Su-Won;Jeong, Tae-Gon;Yang, Jae-Ung;Jeong, Jae-Yeong;Park, Gwang-Min;Jeong, Yong-Hun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.77-77
    • /
    • 2017
  • Titanium and its alloys offer attractive properties in a variety of applications. These are widely used for the field of biomedical implants because of its good biocompatibility and high corrosion resistance. Titanium anodizing is often used in the metal finishing of products, especially those can be used in the medical devices with dense oxide surface. Based on SAE/AMS (Society of Automotive Engineers/Aerospace Material Specification) 2488D, it has the specification for industrial titanium anodizing that have three different types of titanium anodization as following: Type I is used as a coating for elevated temperature forming; Type II is used as an anti-galling coating without additional lubrication or as a pre-treatment for improving adherence of film lubricants; Type III is used as a treatment to produce a spectrum of surface colours on titanium. In this study, we have focused on Type II anodization for the medical (dental and orthopedic) application, the anodized surface was modified with gray color under alkaline electrolyte. The surface characteristics were analyzed with Focused Ion Beam (FIB), Scanning Electron Microscopy (SEM), surface roughness, Vickers hardness, three point bending test, biocompatibility, and corrosion (potentiodynamic) test. The Ti-6Al-4V alloy was used for specimen, the anodizing procedure was conducted in alkaline solution (NaOH based, pH>13). Applied voltage was range between 20 V to 40 V until the ampere to be zero. As results, the surface characteristics of anodic oxide layer were analyzed with SEM, the dissecting layer was fabricated with FIB method prior to analyze surface. The surface roughness was measured by arithmetic mean deviation of the roughness profile (Ra). The Vickers hardness was obtained with Vickers hardness tester, indentation was repeated for 5 times on each sample, and the three point bending property was verified by yield load values. In order to determine the corrosion resistance for the corrosion rate, the potentiodynamic test was performed for each specimen. The biological safety assessment was analyzed by cytotoxic and pyrogen test. Through FIB feature of anodic surfaces, the thickness of oxide layer was 1.1 um. The surface roughness, Vickers hardness, bending yield, and corrosion resistance of the anodized specimen were shown higher value than those of non-treated specimen. Also we could verify that there was no significant issues from cytotoxicity and pyrogen test.

  • PDF