• 제목/요약/키워드: Beam on time

검색결과 1,769건 처리시간 0.025초

새로운 이온빔장치를 사용한 Twisted Nematic-LCD의 전기광학특성 (Electro-optical Characteristics of Twisted Nematic(TN)-LCD using New Ion Beam Equipment)

  • 김상훈;황정연;장미혜;김귀열;서대식
    • 한국전기전자재료학회논문지
    • /
    • 제19권6호
    • /
    • pp.547-551
    • /
    • 2006
  • We studied liquid crystal (LC) alignment with ion beam (IB) on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the polyimide surface using obliquely ion beam (IB) exposure with new IB type equipment. A good uniform alignment of the nematic liquid crystal (NLC) alignment with the ion beam exposure on the polyimide surface was observed. In addition, it can be achieved the good EO properties of the ion-beam-aligned TN-LCD on polyimide surface. Also, the EO characteristics of the ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using new type IB equipment is same or more superior than ion-beam-aligned TN-LCD on a polyimide (PI) surface with ion beam exposure using Kaufman-type Ar ion gun.

보 이론을 이용한 대퇴골 재생성의 해석 (Book Remodeling Analysis of Femur Using Hybrid Beam Theory)

  • 김승종;정재연;하성규
    • 대한기계학회논문집A
    • /
    • 제24권2호
    • /
    • pp.329-337
    • /
    • 2000
  • An investigation has been performed to develop an analysis tool based on a nonlinear beam theory, which can be used to predict the long-term behavior of an artificial hip joint. The nonlinear behav ior of the femur arise from the coupled dependence of the bone density and the mechanical properties on each other. The beam theory together with its numerical algorithm is developed to take into account the nonlinear bone remodeling process of the femur that is long enough to be assumed as a beam. A piecewise linear curve for the bone remodeling rate is used in the bone remodeling theory and the surface area density of bone is modeled as the third order polynomial function of bone density. At each section of the beam, a constant curvature is assumed and the longitudinal strains are also assumed to vary linearly across the section. The Newton-Rhapson iteration method is used to solve the nonlinear equations for each cross section of the bone and a backward method is used to march along the time. The density and the remodeling signal ar, calculated along with time for the various time steps, and the developed beam theory has been verified by comparing with the results of finite element analysis of a remodeling bone with an artificial hip joint of titanium prosthesis subjected to uni-axial loads and pure bending moment. It is concluded that the developed beam theory can be used to predict the long-term behavior of the femur and thus to design the artificial hip prosthesis.

다중표적 간암의 정위적체부방사선치료에서 무편평화여과기선질 용적변조회전치료의 유용성 평가 (A Study of volumetric modulated arc therapy for stereotactic body radiation therapy in case of multi-target liver cancer using flattening filter free beam)

  • 염미숙;윤인하;홍동기;백금문
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.31-43
    • /
    • 2015
  • 목 적 : 정위적체부방사선치료(Stereotatic body radiation therapy, SBRT)는 원발성 종양과 전이성 종양의 치료법으로 이용되어진다. SBRT는 높은 선량을 전달하기 때문에 MU(Monitor unit)의 증가로 치료시간이 길어지고 치료계획용적(Planning Target Volume, PTV) 주변의 정상장기를 효과적으로 보호할 수 있는 치료계획이 필요하다. 특히 다중표적의 경우 SBRT를 여러 번에 나누어 치료해야하거나 선량 겹침으로 인한 고 선량 영역(Hot spot)이 생길수도 있다. 본 연구는 다중표적 간암에서 TrueBeam STx(Varian, USA)의 무편평화여과기선질(Flattening filter free, FFF) beam을 이용한 용적변조회전치료(Volumetric modulated arc therapy, VMAT)의 유용성을 평가하고자 한다. 대상 및 방법 : 다중표적 간암의 SBRT를 시행하는 5명의 환자를 대상으로 TrueBeam STx의 10MV FFF beam을 이용한 VMAT과 15MV 편평화여과기선질(Flattening filter, FF) beam을 이용한 입체조형치료(conformal radiotherapy, CRT)계획을 세웠다. 두 치료계획을 비교하기 위하여 선량용적히스토그램(Dose Volume Histogram, DVH)을 이용하여 치료계획용적(Planning Target Volume, PTV), 간, 십이지장, 장, 식도, 척수에 들어가는 선량을 평가하고 전체 MU 값을 비교하였다. 또한 두 치료계획의 치료시간을 비교하기 위하여 Beam on time을 평가하였다. 결 과 : PTV에 대한 처방선량지수(Conformity Index, CI), 선량균질지수(Homogeneity index, HI), 처방선량포함지수(Paddick's Conformity Index, PCI)의 평균값은 VMAT에서 각각 $1.006{\pm}0.028$, $1.098{\pm}0.016$, $1.132{\pm}0.084$, CRT에서 $1.381{\pm}0.419$ $1.136{\pm}0.042$, $1.534{\pm}0.465$로 평가되었다. 정상장기에 대한 선량은 CRT에서 VMAT 보다 약 1.8배 높은 선량으로 평가되었다. 전체 MU값은 VMAT에서 약 1.3배 높게 평가되었고 VMAT과 CRT 두 치료계획의 평균 Beam on time은 각각 6.8분, 21.3분으로 평가되었다. 결 론 : 다중표적 간암의 정위적체부방사선치료에서 FFF Beam을 이용한 VMAT을 적용하면 선량 겹침 없이 다중표적을 한 번에 치료할 수 있으며 PTV의 선량포함을 만족하면서 주위의 정상장기를 더 효과적으로 보호할 수 있는 치료계획이 가능하다. 또한 FFF Beam의 높은 선량률(Dose rate)을 이용하여 치료시간을 단축시켜 치료 중 발생할 수 있는 오차를 감소시킬 수 있다.

  • PDF

Identification of prestress force in a prestressed Timoshenko beam

  • Lu, Z.R.;Liu, J.K.;Law, S.S.
    • Structural Engineering and Mechanics
    • /
    • 제29권3호
    • /
    • pp.241-258
    • /
    • 2008
  • This paper presents a new identification approach to prestress force. Firstly, a bridge deck is modeled as a prestressed Timoshenko beam. The time domain responses of the beam under sinusoidal excitation are studied based on modal superposition. The prestress force is then identified in the time domain by a system identification approach incorporating with the regularization of the solution. The orthogonal polynomial function is used to improve the noise effect and obtain the derivatives of modal responses of the bridge. Good identification results are obtained from only the first few measured modal data under both sinusoidal and impulsive excitations. It is shown that the proposed method is insensitive to the magnitude of force to be identified and can be successfully applied to indirectly identify the prestress force as well as other physical parameters, such as the flexural rigidity and shearing rigidity of a beam even under noisy environment.

Liquid Crystal Orientation Mechanism: Competition Between Rubbing and Ion-beam Method

  • Kim, Ji-Ho;Han, Jeong-Min;Shon, Jin-Geun
    • Journal of Electrical Engineering and Technology
    • /
    • 제8권6호
    • /
    • pp.1457-1461
    • /
    • 2013
  • The effect of liquid crystal (LC) alignment on a homeotropic polyimide (PI) surface induced by ion beam (IB) irradiation and rubbing process was studied. LC alignment was not affected by IB irradiation with an exposure time of 10 s, and an IB irradiation with an exposure time of 60 s more effectively oriented the LCs on the PI layer than the rubbing process. It was assumed that the LC alignment depended on the C-O bonds created from the C=O bonds on the PI surface broken by IB irradiation after an exposure time of 60 s, which resulted in a strong surface energy that transformed the homeotropic LC alignment to homogeneous states.

광대역 빔 조향을 위한 위상 배열 안테나의 실시간 지연 위상 천이기 구성에 관한 연구 (A Study on Configuration of True Time Delay Phase Shifter for Wideband Beam Steering Phased Array Antenna)

  • 정진우;류지호;박재돈;서종우
    • 한국군사과학기술학회지
    • /
    • 제20권3호
    • /
    • pp.413-420
    • /
    • 2017
  • We investigate the performance of a true time delay(TTD) phase shifter to reduce the beam squint caused by frequency changes of a phased array antenna in wideband communication systems. To design a high gain phased array antenna, we need a long TTD, which causes high RF loss, low resolution and large dimension of TTD phase shifters. To overcome the problems, we propose a schematic of dual TTD phase shifters, which consists of short time delay(STD) in radio frequency(RF) part and long time delay(LTD) in intermediate frequency(IF) part. Our analysis results show that the proposed scheme reduces the required bits and delay time in RF band of the TTD compared to the conventional single TTD scheme.

Wave propagation of a functionally graded beam in thermal environments

  • Akbas, Seref Doguscan
    • Steel and Composite Structures
    • /
    • 제19권6호
    • /
    • pp.1421-1447
    • /
    • 2015
  • In this paper, the effect of material-temperature dependent on the wave propagation of a cantilever beam composed of functionally graded material (FGM) under the effect of an impact force is investigated. The beam is excited by a transverse triangular force impulse modulated by a harmonic motion. Material properties of the beam are temperature-dependent and change in the thickness direction. The Kelvin-Voigt model for the material of the beam is used. The considered problem is investigated within the Euler-Bernoulli beam theory by using energy based finite element method. The system of equations of motion is derived by using Lagrange's equations. The obtained system of linear differential equations is reduced to a linear algebraic equation system and solved in the time domain and frequency domain by using Newmark average acceleration method. In order to establish the accuracy of the present formulation and results, the comparison study is performed with the published results available in the literature. Good agreement is observed. In the study, the effects of material distributions and temperature rising on the wave propagation of the FGM beam are investigated in detail.

전자선 조사된 폴리프로필렌 부직포의 그라프트에 있어 보관조건이 미치는 영향 (Effect of Storage Conditions on Graft of Polypropylene Non-woven Fabric Induced by Electron Beam)

  • 이진영;전준표;강필현
    • 방사선산업학회지
    • /
    • 제9권2호
    • /
    • pp.57-62
    • /
    • 2015
  • In this study, we fabricated effect of storage conditions on graft of polypropylene (PP) non-woven fabric induced by electron beam. The electron beam irradiations on PP non-woven fabric were carried out over a range of irradiation doses from 25 to 100 kGy to make free radicals on fabric surface. The radical measurement was established by electron spin resonance (ESR) for confirming the changes of the alkyl radical and peroxy radical according to effect of storage time, storage temperature and atmosphere. It was observed that the free radicals were increased with irradiation dose and decreased with storage time due to the continuous oxidation. However, the radical extinction was significantly delayed due to reduced mobility of radicals at extremely low temperature. The degree of graft based on the analysis of ESR was investigated. The conditions of graft reaction were set at a temperature: $60^{\circ}C$, reaction time: 6 hours and styrene monomer concentration: 20 wt%.

Simulation of Ultrasonic Beam Focusing on a Defect in Anisotropic, Inhomogeneous Media

  • Jeong, Hyun-Jo;Cho, Sung-Jong;Erdenetuya, Sharaa;Jung, Duck-Yong
    • 비파괴검사학회지
    • /
    • 제31권6호
    • /
    • pp.635-641
    • /
    • 2011
  • In ultrasonic testing of dissimilar metal welds, application of phased array technique in terms of incident beam focusing is not easy because of complicated material structures formed during the multi-pass welding process. Time reversal(TR) techniques can overcome some limitations of phased array since they are self-focusing that does not depend on the geometrical and physical properties of testing components. In this paper, we test the possibility of TR focusing on a defect within anisotropic, heterogeneous austenitic welds. A commercial simulation software is employed for TR focusing and imaging of a side-drilled hole. The performance of time reversed adaptive focal law is compared with those of calculated focal laws for both anisotropic and isotropic welds.

Delamination analysis of inhomogeneous viscoelastic beam of rectangular section subjected to torsion

  • Victor I. Rizov
    • Coupled systems mechanics
    • /
    • 제12권1호
    • /
    • pp.69-81
    • /
    • 2023
  • This paper considers a delamination analysis of a statically undetermined inhomogeneous beam structure of rectangular section with viscoelastic behavior under torsion. The beam is built in at its two ends. The beam has two longitudinal inhomogeneous layers with a delamination crack between them. A notch is made in the upper crack arm. The external torsion moment applied on the beam is a function of time. Under these conditions, the beam has one degree of indeterminacy. In order to derive the strain energy release rate, first, the static indeterminacy is resolved. Then the strain energy release rate is obtained by analyzing the balance of the energy with considering the viscoelastic behavior. The strain energy release rate is found also by analyzing the compliance of the beam for checkup. Solution of the strain energy release rate in a beam without a notch in the upper crack arm is derived too. In this case, the beam has two degrees of static indeterminacy (the torsion moment in the upper crack arm is treated as an additional internal redundant unknown). A parametric investigation of the strain energy release rate is carried-out.