• Title/Summary/Keyword: Beam on time

Search Result 1,783, Processing Time 0.027 seconds

Investigating vibration behavior of smart imperfect functionally graded beam subjected to magnetic-electric fields based on refined shear deformation theory

  • Ebrahimi, Farzad;Jafari, Ali
    • Advances in nano research
    • /
    • v.5 no.4
    • /
    • pp.281-301
    • /
    • 2017
  • In this disquisition, an exact solution method is developed for analyzing the vibration characteristics of magneto-electro-elastic functionally graded (MEE-FG) beams by considering porosity distribution and various boundary conditions via a four-variable shear deformation refined beam theory for the first time. Magneto-electroelastic properties of porous FG beam are supposed to vary through the thickness direction and are modeled via modified power-law rule which is formulated using the concept of even and uneven porosity distributions. Porosities possibly occurring inside functionally graded materials (FGMs) during fabrication because of technical problem that lead to creation micro-voids in FG materials. So, it is necessary to consider the effect of porosities on the vibration behavior of MEE-FG beam in the present study. The governing differential equations and related boundary conditions of porous MEE-FG beam subjected to physical field are derived by Hamilton's principle based on a four-variable tangential-exponential refined theory which avoids the use of shear correction factor. An analytical solution procedure is used to achieve the natural frequencies of porous-FG beam supposed to magneto-electrical field which satisfies various boundary conditions. A parametric study is led to carry out the effects of material graduation exponent, porosity parameter, external magnetic potential, external electric voltage, slenderness ratio and various boundary conditions on dimensionless frequencies of porous MEE-FG beam. It is concluded that these parameters play noticeable roles on the vibration behavior of MEE-FG beam with porosities. Presented numerical results can be applied as benchmarks for future design of MEE-FG structures with porosity phases.

Numerical and experimental assessments of focused microwave thermotherapy system at 925 MHz

  • Kim, Jang-Yeol;Lee, Kwang-Jae;Kim, Bo-Ra;Jeon, Soon-Ik;Son, Seong-Ho
    • ETRI Journal
    • /
    • v.41 no.6
    • /
    • pp.850-862
    • /
    • 2019
  • This work investigated three-dimensional (3D) focused microwave thermotherapy (FMT) at 925 MHz for a human tissue mimicking phantom using the time reversal (TR) principle for musculoskeletal disorders. We verified the proposed TR algorithm by evaluating the possibility of 3D beam focusing through simulations and experiments. The simulation, along with the electromagnetic and thermal analyses of the human tissue mimicking phantom model, was conducted by employing the Sim4Life commercial tool. Experimental validation was conducted on the developed FMT system using a fabricated human tissue mimicking phantom. A truncated threshold method was proposed to reduce the unwanted hot spots in a normal tissue region, wherein a beam was appropriately focused on a target position. The validation results of the simulation and experiments obtained by utilizing the proposed TR algorithm were shown to be acceptable. Effective beam focusing at the desired position of the phantom could be achieved.

Superconducting properties and microstructure of electron beam irradiated MgB2 superconductors

  • Kim, C.J.;Lee, Y.J.;Cho, I.H.;Jun, B.H.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.18-22
    • /
    • 2022
  • The effect of electron beam (EB) irradiation on superconducting properties and microstructures of MgB2 bulk superconductors were investigated. At E-beam doses of 1×1016 e/cm2 and 1×1017 e/cm2, the effect of irradiation on a superconducting transition temperature (Tc) of MgB2 was weak. As a dose increases to 5×1017 e/cm2, Tc decreases by 0.5 K. The critical current density (Jc) measured at 4.2 K and 20 K, and 0 T - 5 T increases slightly as exposure time increases. X-ray diffraction for the irradiation surface of MgB2 shows that the diffraction intensity of (hkl) peaks decreases proportionally as the exposure time increases. This indicates that the crystallinity of MgB2 was degraded by irradiation. TEM investigation for the irradiated sample showed distorted lattice structure, which is consistent with the XRD results. The Jc increase and Tc reduction of MgB2 by irradiation are believed to be caused by the lattice distortion.

An Experimental Study on the Speeds of Various Screen-Film Systems (증감지(增感紙)-Film계(系)의 감도측정(感度測定)에 관(關)한 실험(實驗))

  • Kang, Hong-Seok;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.11 no.1
    • /
    • pp.3-16
    • /
    • 1988
  • Author has made an experiment on absolute speeds of 18 screenfilm combinations that have been on sale in Korea, with various beam qualities. At this time, the beam qualities were 60kVp with the ANSI extremity phantom, 80kVp with the ANSI chest phantom and 85kVp with 20 mm aluminium filter under scatter free condition. The obtained results were as follows; 1. When three independent measurements were performed, the percent standard deviations of mAs quantities of 1.0 + fog were decreased by the hardening of the beam quality, and the decreasing tendency was somewhat great in the blue systems. 2. Generally, the increasing tendency of absolute speeds was distinct by the hardening of the beam quality in the green systems. Conclusively, the green systems were more strongly dependent upon the beam quality rather than the blue systems. Therefore, the relative speed of green systems to blue systems were great under the same condition. 3. Differences in the green systems were kept almost constant even though the beam qualities were changed. 4. They were shown the mutual relationship of absolute speed and relative speed rather than independent.

  • PDF

Structural Diagnosis in Time Domain on Damage Size (손상크기에 따른 시간영역에서의 구조물 진단)

  • 권대규;임숙정;방두열;이성철
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.259-262
    • /
    • 2002
  • This paper provides the experimental verification of a non-destructive time domain approach to examine structural damage. Time histories of the vibration response of structure were used to identify the presence of damage. Damage in a structure cause changes in the physical coefficients of mass density, elastic modulus and damping coefficient. This paper examines the use of beam like structures with PVDF sensor and PZT actuator to perform identification of those physical parameters, and hence to detect the damage. Experimental results are presented from tests on cantilevered composite beams damaged at different location and with damage of different dimensions. It is demonstrated that the method can sense the presence of damage, and characterize the damage to a satisfactory precision.

  • PDF

Numerical investigation seismic performance of rigid skewed beam-to-column connection with reduced beam section

  • Zareia, Ali;Vaghefi, Mohammad;Fiouz, Ali R.
    • Structural Engineering and Mechanics
    • /
    • v.57 no.3
    • /
    • pp.507-528
    • /
    • 2016
  • Reduced beam section (RBS) moment resisting connections are among the most economical and practical rigid steel connections developed in the aftermath of the 1994 Northridge and the 1995 Kobe earthquakes. Although the performance of RBS connection has been widely studied, this connection has not been subject to in the skewed conditions. In this study, the seismic performance of dogbone connection was investigated at different angles. The Commercial ABAQUS software was used to simulate the samples. The numerical results are first compared with experimental results to verify the accuracy. Nonlinear static analysis with von Mises yield criterion materials and the finite elements method were used to analyze the behavior of the samples The selected Hardening Strain of materials at cyclic loading and monotonic loading were kinematics and isotropic respectively The results show that in addition to reverse twisting of columns, change in beam angle relative to the central axis of the column has little impact on hysteresis response of samples. Any increase in the angle, leads to increased non-elastic resistance. As for Weak panel zone, with increase of the angle between the beam and the column, the initial submission will take place at a later time and at a larger rotation angle in the panel zone and this represents reduced amount of perpendicular force exerted on the column flange. In balanced and strong panel zones, with increase in the angle between the beam and the central axis of the column, the reduced beam section (RBS), reaches the failure limit faster and at a lower rotation angle. In connection of skewed beam, balanced panel zone, due to its good performance in disposition of plasticity process away from connection points and high energy absorption, is the best choice for panel zone. The ratio of maximum moment developed on the column was found to be within 0.84 to 1 plastic anchor point, which shows prevention of brittle fracture in connections.

Catching efficiency of a shrimp beam trawl according to the length of beam and wing net and its influence on the hauling work (새우조망 어구의 막대 (빔)와 날개그물 길이에 따른 어획성능과 양망 작업에의 영향)

  • Park, Hae-Hoon
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.3
    • /
    • pp.396-406
    • /
    • 2014
  • Shrimp beam trawl fishery is one of the important coastal fisheries in Korea. It has a regulation to the length of beam (8m) and wing net (7m) of shrimp beam trawl that has been used in the district of Junlanam-do and Gyungsangnam-do. This regulation was made in relation to the size of shrimp beam trawler of 3-ton class at that time. Now the shrimp beam fishing vessel has a limit not greater than 5 tons in gross ton. Recently, with improvement of fishing industry and fishing vessel fishermen asked the expansion of the length of beam and wing net, therefore it is necessary to investigate the effect of lengthening the beam and wing net length. Three different beams (8m, 10m and 12m in length) and three different wing net (7m, 10m and 13m in length) were made and the experiment was conducted near Narodo of Goheng by two fishing vessels of 4.98 and 4.88 tons in gross ton between June 2011 and October 2012. When the length of wing net was increased from 7m to 10m and 13m, the relative catch ratio in total biomass was increased 25% and 79% for shrimp, (17% and 22% in total), respectively. And when the beam length was increased from 8m to 10m and 12m, the relative catch ratio was increased 35% and 84% for shrimp, (21% and 37% in total), respectively. The force exerted to the iron guide of inhauler's with the beam length of 8m was about 30% greater than that with the beam length of 10m when hauling the shrimp beam trawl net.

Homeotropic Alignment Effect of a Nematic Liquid Crystal on Oblique Deposited SiOx Thin-film with e-beam Evaporation

  • Choi, Dai-Seub
    • Transactions on Electrical and Electronic Materials
    • /
    • v.8 no.6
    • /
    • pp.274-277
    • /
    • 2007
  • In this study, liquid crystal(LC) aligning capabilities for homeotropic alignment on the $SiO_x$ thin film by electron beam evaporation method were investigated. Also, the control of pretilt angles and thermal stabilities of the nematic liquid crystal(NLC) treated on $SiO_x$ thin film were investigated. A high pretilt angle of about $86.5^{\circ}$ was obtained, and also the suitable pretilt angle of the NLC on the $SiO_x$ thin film at $10{\sim}50nm$ thickness with e-beam evaporation can be achieved. The uniform LC alignment and good thermal stabilities on the $SiO_x$ thin film surfaces with electron beam evaporation can be achieved. It is considered that the LC alignment on the $SiO_x$ thin film by electron beam evaporation is attributed to elastic interaction between LC molecules and micro-grooves at the $SiO_x$ thin film surface created by evaporation.

Dose Characteristics of Stereotatic Radiosurgery CONE used for ML-6M Linear Accelerator (ML-6M LINAC에 장착한 Radiosurgery Cone의 Beam 특성에 대한 고찰)

  • Moon, Un-Chull;Kim, Hyun-Jin;Kim, Young-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.7 no.1
    • /
    • pp.15-31
    • /
    • 1995
  • The radiosurgery treatment is one time, non surgical approach to the treatment of patients with intracranial disorders whose conditions would be difficult or dangerous to treat with conventional sugical procedures. The LINAC based radiosurgery is based on the combination of multiple isocentric arc irradiation with small fields centered in the stereotactic target. The absorption of the beam in a tissue equivalent medium, such as water, as well as the uniformity, or profile, of the beam must be precisely documented. The beam characteristics and dosimetric measurememts of the 6MV X-ray beam from a ML-6M linear accelerator are examined. The percent depth dose (PDD) and beam profile (including flatness, symmetry and penumbra) is calibrated with the radiosurgery cone in water phantom. The cone is made of lead which size is from $10{\times}10mm{\phi}$ to $30{\times}30mm{\phi}$ All of these dosimetric measurements sufficiently characterized the beam to permit safe clinical use.

  • PDF

LC Orientation Characteristics of NLC on Polyimide Surface According to Ion-beam Irradiation Angles (이온빔 조사각도에 따른 네마틱 액정의 액정 배향 특성)

  • Lee, Kang-Min;Oh, Byeong-Yun;Park, Hong-Gyu;Lim, Ji-Hun;Lee, Won-Kyu;Na, Hyun-Jae;Kim, Byoung-Yong;Han, Jeong-Min;Lee, Sang-Keuk;Seo, Dae-Shik
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.329-329
    • /
    • 2008
  • To date, rubbing has been widely used to align LC molecules uniformly. Although rubbing can be simple, it has fundamental problems such as the generation of defects by dust and static electricity, and difficulty in achieving a uniform LC alignment on a large substrate. Therefore, noncontact alignment has been investigated. Ion beam induced alignment method, which provides controllability, nonstop process, and high resolution display. In this study, we investigated liquid crystal (LC) alignment with ion beam (IB) that non contact alignment technique on polyimide and electro-optical characteristics of twisted nematic (TN)-liquid crystal display (LCD) on the poly imide under various ion beam angles. In this experiment, Polyimide layer was coated on glass by spin-coating and Voltage-transmittance(VT) and response time characteristics of the TN cell were measured by a LCD evaluation system. The good characteristics of the nematic liquid crystal (NLC) alignment with the ion beam exposure poly imide surface was observed. The tilt angle of NLC on the PI surface with ion beam exposure can be measured under $1^{\circ}4 for all of irradiation angles. In addition, it can be achieved the good ED properties, and residual DC property of the ion beam aligned TN cell on polyimide surface.

  • PDF