• Title/Summary/Keyword: Beam extraction

Search Result 153, Processing Time 0.028 seconds

Development of a Low Power Micro-Ion Engine Using Microwave Discharge

  • Koizumi, Hiroyuki;Kuninaka, Hitoshi
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.842-848
    • /
    • 2008
  • In this study, we propose a novel micro-ion engine system. Single plasma source is used for both ion beam source and neutralizing electron source. By changing the electrical connection, either operation can be switched. This micro-ion engine system gives translation motion and attitude control to microspacecraft. The major objective of this study is verification of our concept. Small plasma source of 20 mm diameter was developed. Plasma was sustained by microwave power. Using this plasma source, ion beam extraction and electron emission was successively demonstrated.

  • PDF

Crack Detection of Rotating Blade using Hidden Markov Model (회전 블레이드의 크랙 발생 예측을 위한 은닉 마르코프모델을 이용한 해석)

  • Lee, Seung-Kyu;Yoo, Hong-Hee
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.99-105
    • /
    • 2009
  • Crack detection method of a rotating blade was suggested in this paper. A rotating blade was modeled with a cantilever beam connected to a hub undergoing rotating motion. The existence and the location of crack were able to be recognized from the vertical response of end tip of a rotating cantilever beam by employing Discrete Hidden Markov Model (DHMM) and Empirical Mode Decomposition (EMD). DHMM is a famous stochastic method in the field of speech recognition. However, in recent researches, it has been proved that DHMM can also be used in machine health monitoring. EMD is the method suggested by Huang et al. that decompose a random signal into several mono component signals. EMD was used in this paper as the process of extraction of feature vectors which is the important process to developing DHMM. It was found that developed DHMMs for crack detection of a rotating blade have shown good crack detection ability.

  • PDF

Comparison of panoramic radiography with cone beam CT in predicting the relationship of the mandibular third molar roots to the alveolar canal

  • Shahidi, Shoaleh;Zamiri, Barbod;Bronoosh, Pegah
    • Imaging Science in Dentistry
    • /
    • v.43 no.2
    • /
    • pp.105-109
    • /
    • 2013
  • Purpose: Preoperative radiographic assessment of the mandibular third molars is essential to prevent inferior alveolar nerve damage during extraction. The purpose of this study was to assess the reliability of panoramic signs of association between the roots of teeth and the canal, and to compare the panoramic signs with cone beam computed tomography (CBCT) findings. Materials and Methods: CBCT images of 132 impacted mandibular third molars were evaluated to determine the association of the root to the canal. The CBCT findings were compared with the corresponding panoramic images. Logistic regression analysis was used to define the diagnostic criteria of the panoramic images. Results: Among the panoramic signs, loss of the cortical line was the most frequent radiographic sign predicting association (sensitivity: 79.31). Contact of the tooth with the canal was observed in all cases in which the loss of cortical line of the canal or darkening of the roots was found on the panoramic radiographs. Conclusion: Darkening of the roots and loss of the cortical line on panoramic radiographs might be highly suggestive of the risk of nerve injury.

Design Study of an Axial Injection System for MC50 Cyclotron at KIRAMS

  • Kim, Jae-Hong;Cho, Sung-Jin;Choi, Jun-Yong;Hong, Seung-Pyo;Yu, In-Gong;Park, Hyun;Lee, Ji-Sup
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.262-262
    • /
    • 2012
  • A multi-purpose cyclotron, MC50 has been operated to provide multi-ions of proton, deuteron and alpha at Korea Institute of Radiological and Medical Sciences (KIRAMS). Neutron is also produced through the (p,n) nuclear process with a Be target. However, a wide spectrum of current of ions is requested by beam users for carrying their various application fields. Therefore a simulation study is requested on the design of an axial injection system for high current proton and alpha beam extraction for radio-isotope productions and scientific researches. The purpose of this study is seeking a relatively simple method for the MC50 having higher alpha beam capability and also improving proton and deuteron beams currently used. We are considering two possibilities to improve the internal ion source and to install a new external axial injection system. The external injection system will be consisted of an Einzel lens, a steering magnet, a buncher, and a glazer lens placed in front of an inflector, which is located at the center of the main magnet.

  • PDF

Developmental salivary gland depression in the ascending mandibular ramus: A cone-beam computed tomography study

  • Chen, Christine A.;Ahn, Yoonhee;Odell, Scott;Mupparapu, Mel;Graham, David Mattew
    • Imaging Science in Dentistry
    • /
    • v.46 no.3
    • /
    • pp.223-227
    • /
    • 2016
  • A static, unilateral, and focal bone depression located lingually within the ascending ramus, identical to the Stafne's bone cavity of the angle of the mandible, is being reported. During development of the mandible, submandibular gland inclusion may lead to the formation of a lingual concavity, which could contain fatty tissue, blood vessels, or soft tissue. However, similar occurrences in the ascending ramus at the level of the parotid gland are extremely rare. Similar cases were previously reported in dry, excavated mandibles, and 3 cases were reported in living patients. A 52-year-old African American male patient was seen for pain in the mandibular teeth. Panoramic radiography showed an unusual concavity within the left ascending ramus. Cone-beam computed tomography confirmed this incidental finding. The patient was cleared for the extraction of non-restorable teeth and scheduled for annual follow-up.

Gaussian Model for Laser Image on Curved Surface

  • Annmarie Grant;Sy-Hung Bach;Soo-Yeong Yi
    • Current Optics and Photonics
    • /
    • v.7 no.6
    • /
    • pp.701-707
    • /
    • 2023
  • In laser imaging, accurate extraction of the laser's center is essential. Several methods exist to extract the laser's center in an image, such as the geometric mean, the parabolic curve fitting, and the Gaussian curve fitting, etc. The Gaussian curve fitting is the most suitable because it is based on the physical properties of the laser. The width of the Gaussian laser beam depends on the distance from the laser source to the target object. It is assumed in general that the distance remains constant at a laser spot resulting in a symmetric Gaussian model for the laser image. However, on a curved surface of the object, the distance is not constant; The laser beam is narrower on the side closer to the focal point of the laser light and wider on the side closer to the laser source, which causes the distribution of the laser beam to skew. This study presents a modified Gaussian model in the laser imaging to incorporate the slant angle of a curved object. The proposed method is verified with simulation and experiments.

Reliability of panoramic radiography in predicting proximity of third molars to the mandibular canal: A comparison using cone-beam computed tomography

  • Nunes, Willy James Porto;Vieira, Aline Lisboa;de Abreu Guimaraes, Leticia Drumond;de Alcantara, Carlos Eduardo Pinto;Verner, Francielle Silvestre;de Carvalho, Matheus Furtado
    • Imaging Science in Dentistry
    • /
    • v.51 no.1
    • /
    • pp.9-16
    • /
    • 2021
  • Purpose: The purpose of this study was to analyze the reliability of 7 panoramic radiographic signs for predicting proximity of the root apices of mandibular third molars to the mandibular canal using cone-beam computed tomography and to correlate these findings with the Pell and Gregory and the Winter classification systems. Materials and Methods: An observational, cross-sectional, descriptive study was conducted on 74 patients with bilateral impacted mandibular third molars. Four panoramic radiographic signs were observed in the tooth root (darkening, deflection, and narrowing of the root apices, and bifid apices), and another 3 in the mandibular canal (diversion, narrowing, and interruption of the mandibular canal). Cone-beam computed tomography images were analyzed to identify disruption and diversion of the mandibular canal and root deflection. Results: Binary logistic regression showed that only 4 of the 7 panoramic radiographic signs were able to predict proximity of the root apices of the mandibular third molars to the mandibular canal: darkening of the root, deflection of the root, narrowing of the root, and interruption of the mandibular canal(P<0.05). Conclusion: Darkening, deflection, and narrowing of the root, in tandem with the interruption of the mandibular canal on panoramic radiographs, indicate that cone-beam computed tomography should be performed when planning the extraction of impacted mandibular third molars. Proximity between mandibular third molars and the mandibular canal is correlated with the Winter classification.

The Characteristic Study on the Extraction of a Co Ion in the Metal Ion Implanter (금속이온 주입기에서의 Co 이온의 인출 특성 연구)

  • Lee, Hwa-Ryun;Hong, In-Seok;Trinh, Tu Anh;Cho, Yong-Sub
    • Journal of the Korean Vacuum Society
    • /
    • v.18 no.3
    • /
    • pp.236-243
    • /
    • 2009
  • Proton Engineering Frontier Project (PEFP) has supplied the metal ions to users by using an installed metal ion implanter of 120 keV. At present a feasibility study is being performed for a cobalt ion implantation. For a cobalt ion extraction we studied to sustain the high temperature($648^{\circ}C$) for metal ions vaporization from a cobalt chloride powder by using an alumina crucible in the ion source. The temperature condition of the crucible was satisfied with the plasma generation at the arc current of 120V and EHC power of 250W. The extracted beam current of $Co^+$ ions was dependent on the arc current in the plasma. The maximum beam current was $100{\mu}A$ at 0.18A of the arc current. The 3 peak currents of the extracted ions such as $Co^+$, $CoCl^+$ and $Cl^+$ were obtained by adjusting a mass analyzing magnet and the $Co^+$ ion beam peak current fraction as around 70% in the sum of the peak currents. The fluence of the implanted cobalt ions at the $10{\mu}A$ of the beam current and 90 minutes of the implantation time into an aluminum sample as measured around $1.74{\times}10^{17}#/cm^2$ by a quantitative analysis method of RBS (Rutherford Backscattering Spectrometry).

Characteristics in the Deposition of Mn-Zn Ferrite Thin Films by Ion Beam Sputtering Using a Single Ion Source (단일 이온원을 사용하는 이온빔 스퍼터링법에 의한 Mn-Zn 페라이트 박막의 증착 기구)

  • Jo, Hae-Seok;Ha, Sang-Gi;Lee, Dae-Hyeong;Hong, Seok-Gyeong;Yang, Gi-Deok;Kim, Hyeong-Jun;Kim, Gyeong-Yong;Yu, Byeong-Du
    • Korean Journal of Materials Research
    • /
    • v.5 no.2
    • /
    • pp.239-245
    • /
    • 1995
  • Mn-Zn ferrite thin films were deposited on $SiO_2(1000 \AA)/Si(100)$ by ion beam sputtering using a single ion source. A mosaic target consisting of a single crystal(ll0) Mn-Zn ferrite with a Fe metal strip on it was used. As-deposited films without oxygen gas flow have a wiistite structure due to oxygen deficiencies, which originated from the extra metal atoms sputtered from the metal strips during deposition. The as-deposited films with oxygen gas flow, however, have a spinel structure with (111) preferred orientation. The crystallization of thin films was maximized at the ion beam extraction voltage of 2.lkV, at which the deposited films are bombarded appropriately by the energetic secondary ions reflected from the target. As the extraction voltage increased or decreased from the optimum value, the crystallinity of thin films becomes poor owing to a weak and severe bombardment of the secondary ions, respectively. Crystallization due to the bombardment of the secondary ions was also maximized at the beam incidence angle of $55^{\circ}$. The as-deposited ferrite thin films with a spinel structure showed ferrimagnetism and had an in-plane magnetization easy axis.

  • PDF

Characterization of Cold Hollow Cathode Ion Source by Modification of Electrode Structure (전극 구조 변화에 따른 Cold Hollow Cathode Ion Source의 특성 변화)

  • Seok, Jin-Woo;Chernysh, V.S.;Han, Sung;Beag, Young-Hwoan;Koh, Seok-Keun;Yoon, Ki-Hyun
    • Journal of the Korean Ceramic Society
    • /
    • v.40 no.10
    • /
    • pp.967-972
    • /
    • 2003
  • The inner-diameter 5 cm cold hollow cathode ion source was designed for the high current density and the homogeneous beam profile of ion beam. The ion source consisted of a cylindrical cathode, a generation part of magnetic field, a plasma chamber, convex type ion optic system with two grid electrode, and DC power supply system. The cold hollow cathode ion sources were classified into standard type (I), electron output electrode modified type (II). The operation of the ion source was done with discharge current, ion beam potential and argon gas flow rate. The modification of electron output electrode resulted in uniform plasma generation and uniform area of ion beam was extended from 5 cm to 20 cm. Improved ion source was evaluated with beam uniformity, ion current, team extraction efficiency, and ionization efficiency.