• Title/Summary/Keyword: Beam Quality Factor

Search Result 115, Processing Time 0.03 seconds

Deformation of the floor structure of railway vehicle depending on temperature and humidity (온습도 변화에 따른 철도차량 바닥재의 변형)

  • Shin, Bum-Sik;Kim, Myong-Soo;Choi, Yeon-Sun
    • Proceedings of the KSR Conference
    • /
    • 2008.06a
    • /
    • pp.1002-1007
    • /
    • 2008
  • The floor structure of railway vehicle can deflect and warp due to variation of temperature and humidity at the inside and outside of vehicle. In this study, its temperature and humidity characteristics was investigated experimentally for beam and plate specimen and numerically for the floor structure assembly. The temperature and humidity characteristics of a part were measured and the deformation and stress distribution of the floor structure were calculated using a commercial software. And the warp deformation of the plywood was measured experimentally. The results show that the temperature and humidity effects on the floor structure are the important factor to decide the strength and the quality of the floor structure of railway vehicles.

  • PDF

Introduction of Prediction Method of Welding Deformation by Using Laminated Beam Modeling Theory and Its Application to Railway Rolling Stock

  • Mun, Hyung-Suk;Jang, Chang-Doo
    • International Journal of Railway
    • /
    • v.2 no.4
    • /
    • pp.175-179
    • /
    • 2009
  • The welding deformation and its prediction method at the HAZ (Heat-Affected Zone) are presented in this paper. The inherent strain method is well known as analytical method to predict welding deformation of large scale welded structure. Depend on the size of welding deformation in welding joints, the fatigue life, the stress concentration factor and the manufacturing quality of welded structure are decided. Many welded joints and its manufacturing control techniques are also required to railway rolling stock and its structural parts such as railway carbody and bogie frame. Proposed methods in this paper focus on the two different the inherent strain area at HAZ. This is main idea of proposed method and it makes more reliable result of welding deformation analysis at the HAZ.

  • PDF

Establishment of automated manufacturing system for high-purity [18F]Sodium fluoride: 3-year production experience

  • Jung, Soonjae;Kim, Jung Young;Han, Sang Jin;Seo, Youngbeom;Lee, Kyo Chul;Ryu, Young Hoon;Choi, Jae Yong
    • Journal of Radiopharmaceuticals and Molecular Probes
    • /
    • v.5 no.1
    • /
    • pp.48-53
    • /
    • 2019
  • A bone metastasis is an important factor for prognosis and treatment of breast or prostate cancer patients. [$^{18}F$]Sodium fluoride ([$^{18}F$]NaF) is a PET radiopharmaceutical that can detect bone metastasis. Conventional [$^{18}F$]NaF production process included radioactive metal impurities because the product was prepared by adding saline after beam irradiation to $[^{18}O]H_2O$. In this study, we apply the method of removing radionuclidic impurities. To meet the criteria prescribed by GMP in quality control, we designed the custom-made [$^{18}F$]NaF automatic module. The mean radiochemical yield was $82.1{\pm}4.4%$ (n = 32) productions for 3 years) and the total preparation time was 4 min. The final produced [$^{18}F$]NaF solution meets the USP criteria for quality control. Thus, this fully automated system is validated for clinical use.

An autonomous synchronized switch damping on inductance and negative capacitance for piezoelectric broadband vibration suppression

  • Qureshi, Ehtesham Mustafa;Shen, Xing;Chang, Lulu
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.17 no.4
    • /
    • pp.501-517
    • /
    • 2016
  • Synchronized switch damping (SSD) is a structural vibration control technique in which a piezoelectric patch attached to or embedded into the structure is connected to or disconnected from the shunt circuit in order to dissipate the vibration energy of the host structure. The switching process is performed by a digital signal processor (DSP) which detects the displacement extrema and generates a command to operate the switch in synchronous with the structure motion. Recently, autonomous SSD techniques have emerged in which the work of DSP is taken up by a low pass filter, thus making the whole system autonomous or self-powered. The control performance of the previous autonomous SSD techniques heavily relied on the electrical quality factor of the shunt circuit which limited their damping performance. Thus in order to reduce the influence of the electrical quality factor on the damping performance, a new autonomous SSD technique is proposed in this paper in which a negative capacitor is used along with the inductor in the shunt circuit. Only a negative capacitor could also be used instead of inductor but it caused saturation of negative capacitor in the absence of an inductor due to high current generated during the switching process. The presence of inductor in the shunt circuit of negative capacitor limits the amount of current supplied by the negative capacitance, thus improving the damping performance. In order to judge the control performance of proposed autonomous SSDNCI, a comparison is made between the autonomous SSDI, autonomous SSDNC and autonomous SSDNCI techniques for the control of an aluminum cantilever beam subjected to both single mode and multimode excitation. A value of negative capacitance slightly greater than the piezoelectric patch capacitance gave the optimum damping results. Experiment results confirmed the effectiveness of the proposed autonomous SSDNCI technique as compared to the previous techniques. Some limitations and drawbacks of the proposed technique are also discussed.

Comparison of Radiation Dose in the Measurement of MDCT Radiation Dose according to Correction of Temperatures and Pressure, and Calibration of Ionization Chamber (MDCT 선량측정에서 온도와 압력에 따른 보정과 Ionization Chamber의 Calibration 전후 선량의 비교평가)

  • Lee, Chang-Lae;Kim, Hee-Joung;Jeon, Seong-Su;Cho, Hyo-Min;Nam, So-Ra;Jung, Ji-Young;Lee, Young-Jin;Lee, Seung-Jae;Dong, Kyung-Rae
    • Progress in Medical Physics
    • /
    • v.19 no.1
    • /
    • pp.49-55
    • /
    • 2008
  • This study aims to conduct the comparative analysis of the radiation dose according to before and after the calibration of the ionization chamber used for measuring radiation dose in the MDCT, as well as of $CTDI_w$ according to temperature and pressure correction factors in the CT room. A comparative analysis was conducted based on the measured MDCT (GE light speed plus 4 slice, USA) data using head and body CT dosimetric phantom, and Model 2026C electrometer (RADICAL 2026C, USA) calibrated on March 21, 2007. As a result, the $CTDI_w$ value which reflected calibration factors, as well as correction factors of temperature and pressure, was found to be the range of $0.479{\sim}3.162mGy$ in effective radiation dose than the uncorrected values. Also, under the routine abdomen routine CT image acquisition conditions used in reference hospitals, patient effective dose was measured to indicate the difference of the maximum of 0.7 mSv between before and after the application of such factors. These results imply that the calibration of the ion chamber, and the correction of temperature and pressure of the CT room are crucial in measuring and calculating patient effective dose. Thus, to measure patient radiation dose accurately, the detailed information should be made available regarding not only the temperature and pressure of the CT room, but also the humidity and recombination factor, characteristics of X-ray beam quality, exposure conditions, scan region, and so forth.

  • PDF

Utilization of Rotational Beam Direction Patterns for Performance Enhancement of Cell Boundary UEs (셀 경계 단말의 성능 향상을 위한 회전성 빔 방향 패턴의 활용)

  • Lee, Donghyun;Sung, Wonjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.11
    • /
    • pp.12-20
    • /
    • 2013
  • Even though extensive research results have been applied to wireless cellular systems to improve their capacity and coverage, severe performance degradation experienced in cell boundary areas still remains as a major limiting factor to prohibit further improvement of user equipment (UE) throughput. In the Long Term Evolution-Advanced (LTE-A) standard of the Third Generation Partnership Project (3GPP), Some advanced techniques have been introduced to overcome this "cell-edge problem", including coordinated multipoint transmission and reception (CoMP) and inter-cell interference coordination (ICIC). In this paper, we propose yet another strategy to improve the performance of low-tier UEs by using the concept of multiple beam direction patterns (BDPs). Such multiple BDPs can be implemented using multi-layer antenna arrays stacked vertically at base station (BS) sites to transmit signals in different main beam directions. In comparison to conventional three-sector antennas with a fixed beam pattern, the proposed methods makes signal transmission in a rotational fashion to significantly enhance the reception quality of UEs located near sector (or cell) edge areas, preventing the situation where certain UEs are marginally covered by the BS for the whole transmission time. Performance evaluation results show that the proposed scheme outperforms the conventional three-sector transmission by 171% in low 5% UEs in terms of the UE throughput.

Linearly Polarized 1-kW 20/400-㎛ Yb-doped Fiber Laser with 10-GHz Linewidth (선편광된 10 GHz 선폭의 1 kW급 20/400-㎛ 이터븀 첨가 광섬유 레이저)

  • Jung, Yeji;Jung, Minwan;Lee, Kangin;Kim, Taewoo;Kim, Jae-Ihn;Lee, Yongsoo;Cho, Joonyong
    • Korean Journal of Optics and Photonics
    • /
    • v.32 no.3
    • /
    • pp.120-125
    • /
    • 2021
  • We have developed a linearly polarized high-power Yb-doped fiber laser in the master oscillator power amplifier (MOPA) scheme for efficient spectral beam combining. We modulated the phase of the seed laser by pseudo-random binary sequence (PRBS), with the bit length optimized to suppress stimulated Brillouin scattering (SBS), and subsequently amplified seed power in a 3-stage amplifier system. We have constructed by coiling the polarization-maintaining (PM) Yb-doped fiber, with core and cladding diameters of 20 ㎛ and 400 ㎛ respectively, to a diameter of 9-12 cm for suppression of the mode instability (MI). Finally, we obtained an output power of 1.004 kW with a slope efficiency of 83.7% in the main amplification stage. The beam quality factor M2 and the polarization extinction ratio (PER) were measured to be 1.12 and 21.5 dB respectively. Furthermore, the peak-intensity difference between the Rayleigh signal and SBS signal was observed to be 2.36 dB in the backward spectra, indicating that SBS is successfully suppressed. In addition, it can be expected that the MI does not occur because not only there is no decrease in slope efficiency, but also the beam quality for each amplified output is maintained.

Evaluation of the usefulness of Halcyon VMAT treatment plan through comparison with tomotherapy in bilateral breast cancer radiation therapy. (양측 유방암 방사선치료 시 토모테라피와의 비교를 통한 Halcyon VMAT 치료계획의 유용성 평가)

  • LIM JUN TAEK;PARK JU YOUNG;PARK SU YEON;JEON SEONG JIN;PARK TAE YANG;HWANG DA JIN
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.83-92
    • /
    • 2022
  • Purpose: To evaluate usefulness of Tomotherapy and Halcyon VMAT treatment in radiation therapy for bi-breast cancer Materials and Methods: For 10 patients with bi-breast cancer, volumetric modulated arc therapy(VMAT) treatment plan was established using helical Tomotherapy(Accuray. USA) with field width of 5.0-cm and pitch of 0.287, and Halcyon(Varian Medical System, Palo Alto, CA, Version 3.0 USA) of 6arc and 8arc. Prescribed dose was 42.4 Gy/16, and V 40.3Gy of Planning Target Volume(PTV) was 90%. The quality of plan was evaluated by comparing the dose to tumor and normal organs, and the efficiency was evaluated by comparing total MU and beam on time. Results: About three treatment plans(Tomotherapy, Halcyon 6Arc VMAT, Halcyon 8Arc VMAT) , the mean homogeneity index(H.I) of PTV were 1.07, 1.10, 1.11, and the mean conformity index(C.I) of PTV were 1.21, 1.16, 1.17, respectively. The average value of the dose assessment item for a normal organ is V 5Gy(%) of both lung was 36.3, 31.2, 29.7, and V 15Gy(%) were 18.6, 15.5, 14.6, respectively. The mean heart dose(Gy) were 4.17, 2.69, 2.51. Total MU were (7498.6, 2494.2, 2471.5), and beam on time(sec) were 462.5, 195.4, 198.0. Conclusion: Halcyon VMAT showed similar quality of treatment plan compared to helical Tomotherapy, while also protecting normal organs. In addition, the efficiency of radiotherapy increased due to a decrease in Beam On Time and MU.

A Study on Measurement of Output Dose in X-ray Unit (X-선장치에서 출력선량 측정에 관한 연구)

  • Kim, Jong Eon;Lee, Sang Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.3
    • /
    • pp.289-294
    • /
    • 2020
  • In order to control the quality of X-ray images and patient exposure, it is necessary to document the output dose(air absorption dose(mGy)) output from the X-ray unit from the measurement. The purpose of this study is to find an equation that can calculate the output dose from the measurement of the output dose and output factor(Of) of the X-ray Unit. The output dose and output factors of the X-beam irradiated from the X-ray unit were measured using an XR multi-detector. The output dose calculation formula was obtained by fitting the measured output dose divided by the tube current-exposure time product(mAs) and the set tube voltage with Allometric1. The final output dose calculation formula was obtained by multiplying this formula with the output factor. It is considered that the obtained final output dose calculation formula will be useful for all tube voltages, tube currents, exposure times, field sizes, and distances.

A study on the characteristic of Pockel cell Q-switch for Nd:YAG laser (Nd:YAG Laser를 위한 포켓셀 Q-스위치특성 연구)

  • Kim, Whi-Young
    • Journal of Digital Contents Society
    • /
    • v.10 no.2
    • /
    • pp.199-207
    • /
    • 2009
  • The Q-switching the shutter or the different optical science element puts in within the laser light resonator and the storehouse departs from the within the resonator it loses the mortar and the reversal distribution which when is sufficient creates from within the active medium, opens the shutter instantaneously and it is to do to be made to emit with the light where the energy which is accumulated within the resonator is strong very. Like this Q-switching of laser resonator--It decreases factor increasing suddenly to make. To method of Laser Q-switching mechanical switching methods, electro-optic switching methods and switching by saturable absorber methods, acousto-optic switching method etc. 4 kind are being used on a large scale. In these people the conversion which is electric in compliance with the effect which is electrooptics is widely being used the Q-switching pulse of short pulse width because being it will be able to create. Consequently, Pockel cell where it has the quality of electrooptics effect) the Q-it is become known that it is suitable it uses with switch. From the research which it sees FET and one-chip microprocessor where it is a switching element and pulse transfomer to plan and produce pockel cell Q-switch driving gears, pulse style Nd: It applied in YAG Laser system and it investigated and researched the operating characteristic of the Q-switch. Also, the Q-switch leads and Nd where it is output: YAG with forecast in compliance with a theoretical calculation it comes to buy laser beam side politics it compared and laser beam qualities which had become Q-switching it analyzed.

  • PDF