• 제목/요약/키워드: Beam Head

검색결과 359건 처리시간 0.025초

전자빔건 헤드유니트의 설계와 제작 (Establishment of Gun Head Unit for Electron Beam Machining System)

  • 강재훈;이찬홍;최종호
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1875-1878
    • /
    • 2005
  • It is not efficient and scarcely out of the question to use commercial expensive electron beam lithography system widely used for semiconductor fabrication process for the manufacturing application field of various devices in the small business scope. Then scanning electron microscope based electron beam machining system is maybe regarded as a powerful model can be used for it simply. To get a complete suite of thus proper system, column unit build up with electron beam gun head unit is necessarily required more than anything else to modify scanning electron microscope. In this study, various components included ceramic isolation plate and main body which are essentially constructed for electron beam gun head unit are designed and manufactured. And this electron beam gun head unit will be used for next connected study in the development step of scanning electron microscope based electron beam machining system.

  • PDF

반복하중을 받는 외부 보-기둥 접합부에서 작은 헤드를 사용한 Headed Bar적용 (Application of Headed Bars with Small Head in Exterior Beam-Column Joints Subjected to Reversed Cyclic Loads)

  • 하상수;최동욱;이창호
    • 콘크리트학회논문집
    • /
    • 제19권4호
    • /
    • pp.411-420
    • /
    • 2007
  • 본 연구는 반복 수평 하중을 받는 외부 보-기둥 접합부에서 작은 헤드를 사용한 headed bar의 사용성을 검증하기 위해 $90^{\circ}$ 표준갈고리로 정착한 실험체와 headed bar로 정착한 접합부 실험체를 제작하여 각각의 실험 결과를 비교하였다. 또한, headed bar 정착 성능에 영향을 주는 헤드 단면적, 단조 및 반복 가력 여부, 헤드와 보강근의 용접 여부등의 headed bar 인발 성능에 관한 영향을 구명하기 위한 인발실험을 병행하였다. 인발실험의 결과, headed bar의 인발강도는 헤드 면적 증가에 따라 증가하였고, 헤드와 보강근의 용접 유무, 가력 조건 (단조하중 및 반복하중)은 실험 결과에 큰 영향을 미치지 않는 것으로 나타났다. 외부 보-기둥 접합부 실험의 결과, $90^{\circ}$ 표준갈고리로 정착한 실험체와 headed bar로 정착한 실험체가 초기 균열, 균열의 발생 등 모두 거의 비슷한 양상이었으나, 최종 파괴 시에는 headed bar로 정착된 실험체가 $90^{\circ}$ 표준갈고리로 정착된 실험체에 비해 최대 강도 도달 이후 연성 거동, 연성비 및 변형 성능, 에너지소산 면적 등에서 우수한 거동을 보여주었다. 따라서 ACI 352 위원회의 설계지침을 따라서 제작된 접합부 상세와 동일한 조건으로 표준갈고리 대신 상대적으로 작은 headed bar를 사용할 수 있을 것으로 판단된다.

Development and Evaluation of a Thimble-Like Head Bolus Shield for Hemi-Body Electron Beam Irradiation Technique

  • Shin, Wook-Geun;Lee, Sung Young;Jin, Hyeongmin;Kim, Jeongho;Kang, Seonghee;Kim, Jung-in;Jung, Seongmoon
    • Journal of Radiation Protection and Research
    • /
    • 제47권3호
    • /
    • pp.152-157
    • /
    • 2022
  • Background: The hemi-body electron beam irradiation (HBIe-) technique has been proposed for the treatment of mycosis fungoides. It spares healthy skin using an electron shield. However, shielding electrons is complicated owing to electron scattering effects. In this study, we developed a thimble-like head bolus shield that surrounds the patient's entire head to prevent irradiation of the head during HBIe-. Materials and Methods: The feasibility of a thimble-like head bolus shield was evaluated using a simplified Geant4 Monte Carlo (MC) simulation. Subsequently, the head bolus was manufactured using a three-dimensional (3D) printed mold and Ecoflex 00-30 silicone. The fabricated head bolus was experimentally validated by measuring the dose to the Rando phantom using a metal-oxide-semiconductor field-effect transistor (MOSFET) detector with clinical configuration of HBIe-. Results and Discussion: The thimble-like head bolus reduced the electron fluence by 2% compared with that without a shield in the MC simulations. In addition, an improvement in fluence degradation outside the head shield was observed. In the experimental validation using the inhouse-developed bolus shield, this head bolus reduced the electron dose to approximately 2.5% of the prescribed dose. Conclusion: A thimble-like head bolus shield for the HBIe- technique was developed and validated in this study. This bolus effectively spares healthy skin without underdosage in the region of the target skin in HBIe-.

Evaluation of linear measurements of implant sites based on head orientation during acquisition: An ex vivo study using cone-beam computed tomography

  • Sabban, Hanadi;Mahdian, Mina;Dhingra, Ajay;Lurie, Alan G.;Tadinada, Aditya
    • Imaging Science in Dentistry
    • /
    • 제45권2호
    • /
    • pp.73-80
    • /
    • 2015
  • Purpose: This study evaluated the effect of various head orientations during cone-beam computed tomography (CBCT) image acquisition on linear measurements of potential implant sites. Materials and Methods: Six dry human skulls with a total of 28 implant sites were evaluated for seven different head orientations. The scans were acquired using a Hitachi CB-MercuRay CBCT machine. The scanned volumes were reconstructed. Horizontal and vertical measurements were made and were compared to measurements made after simulating the head position to corrected head angulations. Data was analyzed using a two-way ANOVA test. Results: Statistical analysis revealed a significant interaction between the mean errors in vertical measurements with a marked difference observed at the extension head position (P<0.05). Statistical analysis failed to yield any significant interaction between the mean errors in horizontal measurements at various head positions. Conclusion: Head orientation could significantly affect the vertical measurements in CBCT scans. The main head position influencing the measurements is extension.

듀얼 헤드 갠트리 방사선치료 시스템 설계를 위한 몬테칼로 시뮬레이션 연구 (Modeling of Dual Head Gantry Radiotherapy System with Monte Carlo Simulation)

  • 박승우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권4호
    • /
    • pp.627-632
    • /
    • 2017
  • 듀얼 헤드 갠트리(dual-head) 갠트리 방사선치료 시스템을 설계하기 위해 LINAC의 단일 헤드는 GATE를 예비 연구로 사용하여 모델링되었다. LINAC 헤드는 임상에서 사용되고 있는 VARIAN사를 대상으로 모델링되었다. LINAC 헤드에서 생성된 6MV의 광자선을 물 팬텀에 조사하여 빔의 특성을 평가하였다. GATE 시뮬레이션은 X- 선 스펙트럼을 생성한 후 물 팬텀에 광자선을 조사하였다. 결과로는 백분율 깊이 선량 과 빔의 프로파일을 평가하였으며, $5{\times}5$$10{\times}10cm^2$에서 수행하였다. 빔 품질이 검증 된 후 듀얼 헤드 갠트리(dual head gantry) 방사선치료 시스템을 시뮬레이션 한 후 팬텀(phantom)을 이용한 선량 분포 측면에서 LINAC 시스템의 단일 헤드와 비교하였다. 듀얼 헤드 갠트리 방사선치료 시스템은 단일 헤드 방사선치료 시스템에 비해 방사선치료의 효율 면에서 40~60% 높은 것을 확인할 수 있었으며, 듀얼 헤드 방사선치료 시스템은 방사선치료 및 치료시간을 줄일 수 있을 것이 사료된다.

압전세라믹을 이용한 사각보형 진동자이로의 설계 및 성능분석 (Design and Analysis of Square Beam Type Piezoelectric Vibrating Gyroscope)

  • 이정훈;박연규;이종원
    • 소음진동
    • /
    • 제5권3호
    • /
    • pp.403-411
    • /
    • 1995
  • Square beam type piezoelectric vibrating gyro is developed for the measurement of angular velocity, which is compact, small in size and mass- producible. It features that three pieces of piezoelectric ceramics and bonded onto one face of equilateral square bar type gyro head. Two of them are used as sentuators which drive the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head and measure Coriolis force. The third piece is used for the feedback signal in order to resonate the gyro head with its fundamental natural frequency. Matching two fundamental natural frequencies in the gyro head with its driving frequency is found critical in the design of vibration gyro. Calibration results show that the vibrating gyro developed has the dynamic characteristics of first-order system within the frequency range of interest, which can be easily compensated by a lead compensator.

  • PDF

NFR 방식 Optical Flying Head의 형상 최적설계 (Optimal Design of Optical Flying Head for Near-Field Recording)

  • 김석훈;윤상준;최동훈;정태건;박진무;김수경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1165-1169
    • /
    • 2003
  • This paper presents an approach to optimally design the air-bearing surface (ABS) of the optical flying head for near-field recording technology (NFR). NFR is an optical recording technology using very small beam spot size by overcoming the limit of beam diffraction. One of the most Important problems in NFR is a head disk interface (HDI) issue over the recording band during the operation. A multi-criteria optimization problem is formulated to enhance the flying performances over the entire recording band during the steady state. The optimal solution of the slider, whose target flying height is 50 nm, is automatically obtained. The flying height during the steady state operation becomes closer to the target values than those fur the initial one. The pitch and roll angles are also kept within suitable ranges over the recording band. Especially, all of the air-bearing stiffness are drastically increased by the optimized geometry of the air bearing surface.

  • PDF

Design of Diffraction Limited Head Mounted Display Optical System Based on High Efficiency Diffractive Elements

  • Tehrani, Masoud Kavosh;Fard, Sayed Sajjad Mousavi
    • Current Optics and Photonics
    • /
    • 제1권2호
    • /
    • pp.150-156
    • /
    • 2017
  • A diffraction limited optical system for head mounted displays (HMDs) was designed. This optical system consists of four modules, including 1:5 mm and 5:30 mm beam expanders, polarization grating-polarization conversion system (PG-PCS) and refractive/diffractive projection optical module. The PG-PCS module transforms the unpolarized Gaussian beam to a linearly polarized beam and it simultaneously homogenizes the spatial intensity profile. The optical projector module has a $30^{\circ}$ field of view, a 22 mm eye relief, and a 10 mm exit pupil diameter with a compact structure. Common acrylic materials were utilized in the optical design process; therefore, the final optical system was lightweight. The whole optical system is suitable for a 0.7 inch liquid crystal on silicon microdisplay (LCOS) with HDTV resolution ($1920{\times}1080$) and $8.0{\mu}m$ pixel pitch.

595nm Pulsed Dye Laser를 이용한 수술 흉터 치료 1예 (A Case of the Treatment of Surgical Scar with 595nm Pulsed Dye Laser)

  • 박기남;유승재;정만기;손영익;전형기;김원석;정한신
    • 대한두경부종양학회지
    • /
    • 제22권2호
    • /
    • pp.175-178
    • /
    • 2006
  • Pulsed dye laser(PDL) is originally designed for the treatment of vascular lesions but also effective in improving the quality and appearance of surgical scars. Recently, 595nm Pulsed dye laser(V-beam laser), which has the advantage of deeper tissue penetration and lesser amount of purpura, is spotlighted as a new option for the treatment of surgical scar. The authors treated a surgical scar of a female patient with V-beam laser for 3 times between 4 and 12 weeks after surgery. Subjective satisfaction was improved with visual analogue scale (VAS) and objective improvements were found in parameters of vascularity, pliability and height with Vancouver Scar Scale(VSS). We report the effectiveness of V-beam laser in surgical scar of Asian patient and plan the prospective study with larger scale.

조선시대 목조건축 도리와 보의 결구방법에 관한 연구 (A Study on the Structural Methods between Purlin and Beam at Wooden Architecture in Joseon Dynasty)

  • 정연상
    • 건축역사연구
    • /
    • 제16권6호
    • /
    • pp.87-100
    • /
    • 2007
  • This study examines on the structural Methods between purlin and beam at Wooden Architecture in Joseon Dynasty($1372{\sim}1910$). Through the investigation, it is verified that the structural methods between purlin and beam is the technique utilizing tenon joint(통장부맞춤), Sungeoteok joint(숭어턱맞춤), dovetailed tenon joint(주먹장맞춤). And the methods of tenon joint is followed by the Sungeoteok joint, which is used in the buildings after middle Joseon dynasty. The method of tenon joint(통장부맞춤) is to connect the beam with the purlin by carving out the head of the beam as '一' shape. And the structural methods between Janghyeo(장혀, timber under purlin) and beam is halved joint(반턱맞춤) and tenon joint (통장부맞춤). The buildings in late Goryeo Dynasty and Joseon Dynasty adopted the method of tenon joint between purlin and beam. The method of Sungeoteok joint is to connect the beam with the purlins by carving out the head of the beams '凸' shape. And the structural methods between Janghyeo and beams is halved joint(반턱맞춤) and tenon joint(통장부맞춤), the method of tenon and step joint(통장부턱맞춤), dovetailed joint between beam and Janghyeo to increase the security of shear force.

  • PDF