• Title/Summary/Keyword: Beam Factor

Search Result 1,010, Processing Time 0.025 seconds

Study on the Variation of Energy Dissipation Factor of Reinforced Concrete Beam under Cyclic Loading (반복하중을 받는 철근콘크리트 보의 에너지소산계수 변화 특성 고찰)

  • Suk-Hyeong Yoo;Dae-Young Kang
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.6
    • /
    • pp.86-93
    • /
    • 2023
  • As the hysteretic behavior of reinforced concrete members under cyclic loading progresses, the energy dissipation ability decreases due to a decrease in stiffness and strength and pinching effects. However, the guideline "Nonlinear Analysis Model for Performance-Based Seismic Design of Reinforced Concrete Building Structures, 2021" requires calculating a single energy dissipation factor for each member and all histeric step, so the decrease in energy dissipation capacity according to histeric step cannot be considered. It is judged that Therefore, in this study, the energy dissipation factor according to the histeric step was examined by comparing the existing experimental results and the nonlinear time history analysis results for a general beam under cyclic loading. The energy dissipation factor was calculated as the ratio of the energy dissipation amount of the actual specimen to the energy dissipation amount of the idealized elastoplastic behavior obtained as a result of nonlinear time history analysis. In the existing experiment results, the energy dissipation factor was derived by calculating one cycle for each histeric step, and the energy dissipation factor was derived based on the nonlinear modeling process in the guidelines. In the existing experimental study, the energy dissipation factor was calculated by setting each histeric step (Y-L-R), and the energy dissipation factor was found to be 0.36 in the Y-L step and 0.28 in the L-R step, and the energy dissipation factor in the guideline was found to be 0.31. This shows that the energy dissipation factor calculation formula in the guidelines does not indicate a decrease in the energy dissipation capacity of reinforced concrete members.

Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays (RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구)

  • Lee, Jeong-Ok;Jeong, Dong-Hyeok;Kim, Bu-Gil
    • Journal of radiological science and technology
    • /
    • v.32 no.2
    • /
    • pp.205-212
    • /
    • 2009
  • The response correction factor ( h) is a factor to convert the response of the chamber in solid phantom to the response in water. In RW3 solid phantom, the dependency of beam quality and depth for high energy X-rays are known characteristics, however the dependency of field size, SSD, and chamber type are unknown. In this work we have studied the unknown characteristics on the dependency of response correction factor. The farmer type chamber (FC65G) and small chamber (CC13) were used and two beam qualities of 6 and 15 MV were evaluated. The measured response correction factors at the depth of 5 cm and 10 cm were h = 1.015 and 1.021 for 6 MV X-rays, and h = 1.024 and 1.029 for 15 MV X-rays. In conclusion the response correction factor did not depend on the field size and SSD while depending on the beam quality and depth. In the chambers, there are small differences between the two chambers used in this study but we think additional study for more chambers should be required. The results in this study can be used for analyzing the measured values from ionization chamber dosimetry in RW3.

  • PDF

Polyphase I/Q Network and Active Vector Modulator Based Beam-Forming Receiver For UAV Based Airborne Network (UAV 공중 네트워크를 위한 손실 없는 Polyphase I/Q 네트워크 및 능동 벡터 변조기 기반 빔-포밍 수신기)

  • Jung, Won-jae;Hong, Nam-pyo;Jang, Jong-eun;Chae, Hyung-il;Park, Jun-seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.41 no.11
    • /
    • pp.1566-1573
    • /
    • 2016
  • This paper presents a beam-forming receiver with polyphase In-phase/Quadrature-phase (I/Q) network for airborne communication. In beam-forming receiver, the insertion loss (IL) difference between input path increases the receiver noise figure (NF). The major element for generating IL difference is the impedance variation of phase shifter. In order to maintain a constant IL in every phase, this paper propose a lossless polyphase I/Q network based beam-forming receiver. The proposed lossless polyphase I/Q network has low Q-factor and high impedance for drive back-end VGA (Variable gain amplifier) block with low insertion loss. The 2-stage VGA controls in-phase and quadrature-phase amplitude level for vector summation. The proposed beam-forming receiver prototype is fabricated in TSMC $0.18{\mu}m$ CMOS process. The prototype cover the $360^{\circ}$ with $5.6^{\circ}$ LSB. The average RMS phase error and amplitude error is approximately $1.6^{\circ}$ and 0.3dB.

Determination of Beam Quality Correction Factors for the PTW-Markus Chamber for Electron Beam Qualities R50=1.0 and 1.4 g/cm2 (전자선 선질 R50=1.0과 1.4 g/cm2에 대한 PTW-Markus 전리함의 선질보정인자 결정에 관한 연구)

  • Kim, Me Young;Rhee, Dong Joo;Moon, Young Min;Jeong, Dong Hyeok
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.178-184
    • /
    • 2015
  • The Markus ionization chamber(R) is a small plane parallel ionization chamber widely used in clinical electron beam dosimetry. Plane parallel chambers were recommended for low energy electron dosimetry with the beam quality at $R_{50}<4.0g/cm^2$ (${\bar{E}}{\approx}10MeV$) according to TRS-398 protocol. However, the quality correction factors ($k_{Q,Q_0}$) of the Markus chamber was not presented in TRS-398 protocol for electron beam quality at $R_{50}<2.0g/cm^2$ (${\bar{E}}{\approx}4MeV$). In this study, the $k_{Q,Q_0}$ factors of the Markus chambers (PTW-34045) for beam qualities at $R_{50}=1.0$, 1.4, 2.0, 2.5, 3.0, and $5.0g/cm^2$ were determined by Monte Carlo calculations (DOSRZnrc/EGSnrc) and the dosimetric formalism of quality correction factor. The derived $k_{Q,Q_0}$ values were evaluated using the produced data based on TRS-398 and TG-51 protocols and known values for the Markus chamber.

Nonlinear Flexural Analysis of RC Beam Rehabilitated by Very-Early Strength Latex-Modified Concrete (초속경 라텍스개질 콘크리트로 보강된 RC보의 비선형 휨해석)

  • Choi, Sung-Yong;Yun, Kyong-Ku;Kim, Yong-Bin;Kang, Mun-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.11
    • /
    • pp.4635-4642
    • /
    • 2010
  • Latex modification of concrete provides the material with higher flexural strength, as well as high bond strength and reduced water permeability. One of the most advantages of the very early-strength latex-modified concrete (VES-LMC) could be the similar contraction and expansion behaviour to normal concrete substrate, which enable to ensure long-term performance. The purpose of this study was to parametric nonlinear flexural nonlinear analysis of RC beam rehabilitated by VES-LMC. The results were as follows; The flexural nonlinear analysis model of RC beam overlaid by VES-LMC in ABAQUS was proposed to predict the load-deflection response, interfacial stress, and ultimate strength. The proposed FE analysis model was verified by comparison of an experimental data and the FE analysis results. The FE analysis results showed that yield point as well as flexural stiffness increased as the depth increased; the stiffness of beam overall increased as the bond stiffness became larger; the bond strength between two different materials is a key factor in composite beam. A parametric study showed that an overlay thickness was a main influencing factor to the behavior of RC beam overlaid by VES-LMC.

Post-buckling analysis of shear-deformable composite beams using a novel simple two-unknown beam theory

  • Kaci, Abdelhakim;Houari, Mohammed Sid Ahmed;Bousahla, Abdelmoumen Anis;Tounsi, Abdelouahed;Mahmoud, S.R.
    • Structural Engineering and Mechanics
    • /
    • v.65 no.5
    • /
    • pp.621-631
    • /
    • 2018
  • In this paper, an exact analytical solution is developed for the analysis of the post-buckling non-linear response of simply supported deformable symmetric composite beams. For this, a new theory of higher order shear deformation is used for the analysis of composite beams in post-buckling. Unlike any other shear deformation beam theories, the number of functions unknown in the present theory is only two as the Euler-Bernoulli beam theory, while three unknowns are needed in the case of the other beam theories. The theory presents a parabolic distribution of transverse shear stresses, which satisfies the nullity conditions on both sides of the beam without a shear correction factor. The shear effect has a significant contribution to buckling and post-buckling behaviour. The results of this analysis show that classical and first-order theories underestimate the amplitude of the buckling whereas all the theories considered in this study give results very close to the static response of post-buckling. The numerical results obtained with the novel theory are not only much more accurate than those obtained using the Euler-Bernoulli theory but are almost comparable to those obtained using higher order theories, Accuracy and effectiveness of the current theory.

The Experimental Studu on the P-Δ Influence of Weak Beam Unbraced Frames (보항복형 비가새 골조의 PΔ 영향에 관한 실험적 연구)

  • Kim, Hee Dong;Park, Sang Chul;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.363-372
    • /
    • 2001
  • The objective of this study is to evaluate the $P-{\Delta}$ effect in the case of weak beam unbraced frames by experimental approach. To evaluate $P-{\Delta}$ effect, four specimens were tested under monotonic loading condition. The parameters of tests are the stiffness of column and the axial load ratio. The results show that the value of axial load affects frame stability because $P-{\Delta}$ effects promote the yielding of beam. The maximum lateral load increases in proportion to the increment of column stiffness and rotational stiffness of supports, The collapse mechanism of weak beam unbraced frames is stably formed in the condition of low axial load ratio. The $B_2$ factor of limit state design code does not properly consider the $P-{\Delta}$ effect in inelastic region.

  • PDF

Experimental Study on the Structural Capacity of the U-Flanged Truss Steel Beam (U-플랜지 트러스 보의 구조 내력에 관한 실험 연구)

  • Oh, Myoung Ho;Kim, Young Ho;Kang, Jae Yoon;Kim, Myeong Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.18 no.4
    • /
    • pp.113-121
    • /
    • 2018
  • U-flanged truss beam is composed of u-shaped upper steel flange, lower steel plate of 8mm or more thickness, and connecting lattice bars. Upper flange and lower plate are connected by the diagonal lattice bars welded on the upper and lower sides. In this study the structural experiments on the U-flanged truss beams with various shapes of upper flange were performed, and the flexural and shear capacities of U-flanged truss beam in the construction stage were evaluated. The principal test parameters were the shape of upper flange and the alignment space of diagonal lattice bars. In all the test specimens, the peak loads were determined by the buckling of lattice bar regardless of the upper flange shape. The test results have shown that the buckling of lattice bar is very important design factor and there is no need to reinforce the basic u-shaped upper flange. However, the early lattice buckling occurred in the truss beam with upper steel bars because of the insufficient strength and stiffness of upper chord, and the reinforcement in the upper chord is necessary. The formulae of Eurocode 3 (2005) have presented more exact evaluations of lattice buckling load than those of KBC 2016.

Development of Multi-channel Fiber Laser and Beam Alignment Method (다채널 광섬유 레이저 및 다중 빔 정렬 기술 개발)

  • Kim, Youngchan;Ryu, Daegeon;Noh, Young-Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.33 no.6
    • /
    • pp.245-251
    • /
    • 2022
  • We have developed a multi-channel fiber laser for tiled laser beam combining and a laser output array system for multi-beam alignment. The fiber laser is a master oscillator power amplifier configuration that has a common seed, a preamplifier, and a 7-channel amplifier. The output power of each channel is more than 10 W. The laser output array system is a packed cylindrical configuration for a high fill-factor, and it has capabilities for collimation and tilt control with built-in PZT. Multi-beam alignment to a target is successfully implemented using PZT controlled with a stochastic parallel gradient descent (SPGD) algorithm.

Number of Phase Screens Required for Simulation of a High-energy Laser Beam's Propagation Experiencing Atmospheric Turbulence and Thermal Blooming (대기 난류와 열적 블루밍을 겪는 고출력 레이저 빔의 대기 전파 시뮬레이션에 필요한 위상판 개수 분석)

  • Seokyoung Yoon;Woohyeon Moon;Hoon Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.35 no.2
    • /
    • pp.49-60
    • /
    • 2024
  • We analyze the number of phase screens required for the simulation of a high-energy laser beam's propagation over an atmospheric channel. For high-energy lasers exceeding tens of kilowatts (kW) in power, the laser beam is mainly affected by atmospheric turbulence and thermal blooming. When using the split-step method to implement losses due to atmospheric absorption and scattering and distortion of the beam due to turbulence and thermal blooming, the number of phase screens is a critical factor in determining the accuracy and time required for the simulation. By comparing simulation results obtained using a large number of phase screens (e.g., 150 screens) under a wide range of atmospheric turbulence conditions, we provide new guidelines for the number of phase screens required for simulating the beam propagation of a high-power laser below 2.5×106 W/m2 (e.g., a 500-kW laser beam having a 50-cm diameter).