• Title/Summary/Keyword: Beam Center

Search Result 2,031, Processing Time 0.038 seconds

Various Technologies for Simultaneous Removal of NOx and SO2 from Flue Gas (배출가스의 질소산화물과 이산화황 동시 저감 기술)

  • Park, Hyun-Woo;Uhm, Sunghyun
    • Applied Chemistry for Engineering
    • /
    • v.28 no.6
    • /
    • pp.607-618
    • /
    • 2017
  • Harmful air pollutants are exhausted from the various industrial facilities including the coal-fired thermal power plants and these substances affects on the human health as well as the nature environment. In particular, nitrogen oxides ($NO_x$) and sulfur dioxide ($SO_2$) are known to be causative substances to form fine particles ($PM_{2.5}$), which are also deleterious to human health. The integrated system composed of selective catalytic reduction (SCR) and wet flue gas desulfurization (WFGD) have been widely applied in order to control $NO_x$ and $SO_2$ emissions, resulting in high investment and operational costs, maintenance problems, and technical limitations. Recently, new technologies for the simultaneous removal of $NO_x$ and $SO_2$ from the flue gas, such as absorption, advanced oxidation processes (AOPs), non-thermal plasma (NTP), and electron beam (EB), are investigated in order to replace current integrated systems. The proposed technologies are based on the oxidation of $NO_x$ and $SO_2$ to $HNO_3$ and $H_2SO_4$ by using strong aqueous oxidants or oxidative radicals, the absorption of $HNO_3$ and $H_2SO_4$ into water at the gas-liquid interface, and the neutralization with additive reagents. In this paper, we summarize the technical improvements of each simultaneous abatement processes and the future prospect of technologies for demonstrating large-scaled applications.

IN-VIVO DOSE RECONSTRUCT10N USING A TRANSMISION FACTOR AND AN EFFECTIVE FIELD CONCEPT (팬텀투과계수와 유효조사면 개념을 이용한 종양선량 확인에 관한 연구)

  • Kim, You-Hyun;Yeo, In-Hwan;Kwon, Soo-Il
    • Journal of radiological science and technology
    • /
    • v.25 no.1
    • /
    • pp.63-71
    • /
    • 2002
  • The aim of this study Is to develop a simple and fast method which computes in-vivo doses from transmission doses measured doting patient treatment using an ionization chamber. Energy fluence and the dose that reach the chamber positioned behind the patient is modified by three factors: patient attenuation, inverse square attenuation. and scattering. We adopted a straightforward empirical approach using a phantom transmission factor (PTF) which accounts for the contribution from all three factors. It was done as follows. First of all, the phantom transmission factor was measured as a simple ratio of the chamber reading measured with and without a homogeneous phantom in the radiation beam according to various field sizes($r_p$), phantom to chamber distance($d_g$) and phantom thickness($T_p$). Secondly, we used the concept of effective field to the cases with inhomogeneous phantom (patients) and irregular fields. The effective field size is calculated by finding the field size that produces the same value of PTF to that for the irregular field and/or inhomogeneous phantom. The hypothesis is that the presence of inhomogeneity and irregular field can be accommodated to a certain extent by altering the field size. Thirdly, the center dose at the prescription depth can be computed using the new TMR($r_{p,eff}$) and Sp($r_{p,eff}$) from the effective field size. After that, when TMR(d, $r_{p,eff}$) and SP($r_{p,eff}$) are acquired. the tumor dose is as follows. $$D_{center}=D_t/PTF(d_g,\;T_p){\times}(\frac{SCD}{SAD})^2{\times}BSF(r_o){\times}S_p(r_{p,eff}){\times}TMR(d,\;r_{p,eff})$$ To make certain the accuracy of this method, we checked the accuracy for the following four cases; in cases of regular or irregular field size, inhomogeneous material included, any errors made and clinical situation. The errors were within 2.3% for regular field size, 3.0% irregular field size, 2.4% when inhomogeneous material was included in the phantom, 3.8% for 6 MV when the error was made purposely, 4.7% for 10 MV and 1.8% for the measurement of a patient in clinic. It is considered that this methode can make the quality control for dose at the time of radiation therapy because it is non-invasive that makes possible to measure the doses whenever a patient is given a therapy as well as eliminates the problem for entrance or exit dose measurement.

  • PDF

Property of Dose Distribution in Accordance with Dose Rate Variation in Intensity Modulated Radiation Therapy (세기조절방사선치료에서 선량율 변화에 따른 선량분포 특성)

  • Kang, Min-Kyu;Kim, Sung-Joon;Shin, Hyun-Soo;Kim, Sung-Kyu
    • Progress in Medical Physics
    • /
    • v.21 no.2
    • /
    • pp.218-222
    • /
    • 2010
  • As radiation is irradiated from various directions in intensity modulated radiation therapy (IMRT), longer treatment time than conventional treatment method is taken. In case of the patients who have problem to keep same posture for long time because of pain and injury, reducing treatment time through increased dose rate is a way for effective treatment. This study measured and found out the variation of dose and dose distribution in accordance with dose rate variation. IMRT treatment plan was set up to investigate from 5 directions - $0^{\circ}$, $72^{\circ}$, $144^{\circ}$, $216^{\circ}$, $288^{\circ}$ - using ECLIPSE system (Varian, SomaVision 6.5, USA). To confirm dose and dose rate in accordance with dose rate variation, dose rate was set up as 100, 300, 500 MU/min, and dose and dose distribution were measured using ionization chamber (PTW, TN31014) and film dosimeter (EDR2, Kodak). At this time, film dosimeter was inserted into acrylic phantom, then installed to run parallel with beam's irradiating direction, 21EX-S (Varian, USA) was utilized as linear accelerator for irradiation. The measured film dosimeter was analyzed using VXR-16 (Vidar System Corporation) to confirm dose distribution.

A Study on the Measurement of Half-life for the 179Re Isotope Produced by a 100 MeV Proton Nuclear Reaction (100 MeV 양성자 핵반응에 의해 생성된 179Re 동위원소의 반감기 측정에 관한 연구)

  • Lee, Samyol
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.4
    • /
    • pp.447-453
    • /
    • 2020
  • This study accurately measured the half-life of the 179Re radioactive isotope using the 100 MeV proton and high-purity HPGe gamma ray measurement system generated from a high-energy proton linear accelerator at the Korea Atomic Energy Research Institute. The result obtained is 19.64 ± 0.26 min. Compared with the past results of the half-life of the 179Re radioisotope known to date, the results of B. Harmatz published in 1960 and B. J. Meijer published in 1975 measured the median value higher than the results obtained in this study. In the case of K. J. Hofstetter, published in 1966, a very large error is also characteristic. This result showed a tendency that the center value was very consistent with the result of this study. The results of Coral M. Baglin's 19.5 min published in 2009 are very consistent with the error range. The obtained measured result was compared with the result of ENSDF (Evaluated Nuclear Structure Data File). Through this study, more reliable values were measured for the results of the half-life of the 179Re, which was previously incorrect, and the validity of the recently published results of Coral M. Baglin was confirmed.

The Optimal Condition and Enzyme Activity of Entomopathogenic Fungus Beauveria bassiana Using Extracted Rice Bran (미강추출물을 이용한 곤충병원성 곰팡이 Beauveria bassiana의 최적 배양조건 및 효소활성)

  • Kim, Chang-Su;Lee, Jung-Bok;Kim, Beam-Soo;Lee, Min-Hye;Kang, Kyeong-Muk;Joo, Woo-Hong;Kim, Jin-Won;Im, Dae-Joon;Kwon, Gi-Seok
    • Journal of Life Science
    • /
    • v.23 no.8
    • /
    • pp.1010-1018
    • /
    • 2013
  • The greenhouse whitefly, Bemisia tabaci, is considered one of the most destructive pests of crops. In this study, we aimed to determine the optimal liquid culture conditions in shake flasks for maximal sporulation of Beauveria bassiana M130 using rice bran. The optimal initial pH for the spore production of B. bassiana using extracted rice bran medium was 5.2 and $28^{\circ}C$. The screening in shake flasks of carbon and nitrogen sources resulted in the identification of an optimal medium based on 0.5% $(NH_4)_2SO_4$, with extracted rice bran 8:1. Using this medium, a production level of $2.15{\times}10^9$ spores per ml was obtained after six days from culture inoculation at $28^{\circ}C$ in a rotary shaking incubator at 130 rpm. In addition, the specific activities of extracellular enzymes of chitinase and protease were $4,296{\mu}mol$ and $375{\mu}mol$, respectively. These results suggest that Beauveria bassiana M130 could be a bio-controller for the greenhouse whitefly.

The Effects of Cynanchi wilfordii Radix Ethanol Extracts upon Irradiated Rat's Blood and Organ (백하수오 에탄올추출물이 방사선조사에 따른 흰쥐의 혈구 및 장기에 미치는 영향)

  • Kim, Jang-Oh;Choi, Jun-Hyeok;Shin, Ji-Hye;Jung, Do-Young;Min, Byung-In
    • Journal of radiological science and technology
    • /
    • v.39 no.3
    • /
    • pp.451-459
    • /
    • 2016
  • The development of radioprotector is being actively conducted in order to reduce the damage from over radiation exposure at radiation accident or radiation therapy. So this study was confirmed for radiation protective effects using the Cynanchi wilfordii Radix that has been known to be effective for antioxidant activity, anti-cancer, immune enhancing effects. The method of this study was administered orally Cynanchi wilfordii Radix ethanol extracts to Sprague Dawley Rat(SD Rat) for 14 days once a day, while measuring changed blood cell, spleen index, liver and uterus tissue along the change in time of 1, 4, 7 and 21 days after X-ray beam of 7 Gy irradiation. As the result of the experiment, the experimental group's rats which are administered with Cynanchi Wilfordii Radix ethanol extracts showed a rapid recovery in white blood cell count(p < 0.05) and spleen index(p < 0.05). In addition, condensation of nuclei, cytoplasmic swelling, and inflammatory cell infiltration in experimental group's liver cell was decreased more than in irradiation group's component. Further, experimental group's Uterine gland decreased the apoptosis more than irradiation group's components did. It is expected that Cynanchi Wilfordii Radix extracts will be useful as a new radioprotector. With above in mind, this paper may provide appropriate implications with the field of emergency management such as radiation accident.

Color Filter Based on a Sub-wavelength Patterned Metal Grating (광파장 이하 주기를 갖는 금속 격자형 컬러필터)

  • Lee, Hong-Shik;Yoon, Yeo-Taek;Lee, Sang-Shin;Kim, Sang-Hoon;Lee, Ki-Dong
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.6
    • /
    • pp.383-388
    • /
    • 2007
  • A color filter was demonstrated incorporating a patterned metal grating in a quartz substrate. The filter is created in a metal layer perforated with a symmetric two-dimensional array of circular holes, with the pitch smaller than the wavelength of the visible light. A finite-difference time-domain simulation was performed to analyze the device by investigating the effect of structural parameters like the grating height, the period, the hole size, and the refractive index of the hole-filling material on its performance. The device performance was especially optimized by controlling the refractive index of the material comprising the holes of the grating. And two different devices were fabricated by means of the e-beam direct writing with the following design parameters: the grating height of 50 nm, the two pitches of 340 nm for the red color and 260 nm for the green color. For the prepared device with the period of 340 nm, the center wavelength was 680 nm and the peak transmission 57%. And for the other device with the pitch of 260 nm, the center wavelength was 550 nm and the peak transmission was 50%. The filling of the hole with a material whose refractive index is matched to that of the substrate has led to an increase of ${\sim}15%$ in the transmission efficiency.

MPTP-induced vulnerability of dopamine neurons in A53T α-synuclein overexpressed mice with the potential involvement of DJ-1 downregulation

  • Lee, Seongmi;Oh, Seung Tack;Jeong, Ha Jin;Pak, Sok Cheon;Park, Hi-Joon;Kim, Jongpil;Cho, Hyun-seok;Jeon, Songhee
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.6
    • /
    • pp.625-632
    • /
    • 2017
  • Familial Parkinson's disease (PD) has been linked to point mutations and duplication of the ${\alpha}$-synuclein (${\alpha}$-syn) gene. Mutant ${\alpha}$-syn expression increases the vulnerability of neurons to exogenous insults. In this study, we developed a new PD model in the transgenic mice expressing mutant hemizygous (hemi) or homozygous (homo) A53T ${\alpha}$-synuclein (${\alpha}$-syn Tg) and their wildtype (WT) littermates by treatment with sub-toxic (10 mg/kg, i.p., daily for 5 days) or toxic (30 mg/kg, i.p., daily for 5 days) dose of 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine (MPTP). Tyrosine hydroxylase and Bcl-2 levels were reduced in the ${\alpha}$-syn Tg but not WT mice by sub-toxic MPTP injection. In the adhesive removal test, time to remove paper was significantly increased only in the homo ${\alpha}$-syn Tg mice. In the challenging beam test, the hemi and homo ${\alpha}$-syn Tg mice spent significantly longer time to traverse as compared to that of WT group. In order to find out responsible proteins related with vulnerability of mutant ${\alpha}$-syn expressed neurons, DJ-1 and ubiquitin enzyme expressions were examined. In the SN, DJ-1 and ubiquitin conjugating enzyme, UBE2N, levels were significantly decreased in the ${\alpha}$-syn Tg mice. Moreover, A53T ${\alpha}$-syn overexpression decreased DJ-1 expression in SH-SY5Y cells. These findings suggest that the vulnerability to oxidative injury such as MPTP of A53T ${\alpha}$-syn mice can be explained by downregulation of DJ-1.

Antioxidative and Antimicrobial Activities of Extracts from Different Parts of Crotalaria sessiflora L. (활나무 부위별 추출물의 유지에 대한 항산화 효과 및 항균성에 관한 연구)

  • Woo, NaRiYah;Kim, TaeSoo;Park, Chun-Geon;Seong, Ha-Jeong;Ko, Sang-Beam;Kang, Myung-Hwa
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.34 no.7
    • /
    • pp.948-952
    • /
    • 2005
  • The antioxidative and antimicrobial properties of the solvent extracts of 3 parts (leaf, stem, root) of Crotalaria sessiflora L. were investigated, in order to find out new natural food additives. The antioxidative activities of the extracts were determined by peroxide value (POV) and the conjugated diene value (CDV) of corn oil stored for 30 days at $60\pm2^{\circ}C$. Each part of the extracts were added as $0.02,\;0.05\%$ and then compared with BHT. The anti oxidative activities were as follows in decreasing order: BHT > LeafEX > StemEX > RootEX > control. The induction period showed that the part of the Crotalaria sessifloria L. group added with solvent extract showed a longer induction period compared with the control group. The part of Crotalaria sessiflora L. solvent extract were shown to have antimicrobial effects on the microorganism such as Bacillus subtilis, Staphylococcus aureus, Listeria monocytogenes, Salmonella Enteritidis, Pseudomonas flrourescens and Escherichia coli. Especially the effect on the Pseudomonas flrourescens was remarkable.

The study of improving the performance of lower direction finding ability due to the interfered phase difference of circular array Antennas (원형배열안테나의 위상간섭에 의한 방향탐지 성능저하 개선연구)

  • Chung, Jae-Woo;Kim, Young-Kil
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.535-539
    • /
    • 2010
  • This paper include to study DoA(Direction of Arrival) for radio collection and monitoring system. The direction finding calculated by applying the CVDF (Correlation Vector Direction Finding) algorithm for the five circular dipole antenna over V / UHF band. To improve the accuracy of direction finding by applying CVDF algorithm needs to obtain ideal phase difference each antennas. However, a circular array antenna phase difference pattern may be distorted on a specific frequency band or to particular direction. The effect of installing each array antennas circularly and the effect of the interference of center pole (located in the center of a circular array antenna mount) may make the distortion of phase pattern. If you use an active antenna instead of passive antenna to obtain good sensitivity, you would measure the more distortion. This paper propose how to change combination of antennas to measure the phase in real-time and how to use antenna beam patterns for minimizing the degradation phenomena at applying simple CVDF algorithm and increasing the direction finding capability.

  • PDF