• Title/Summary/Keyword: Bead shape

Search Result 255, Processing Time 0.023 seconds

Verification of Target Position in Stereotactic Radiosurgery Based on Photon Knife System (Photon Knife 시스템에 근거한 뇌정위 방사선수술에서 표적위치 확인)

  • 최태진;김진희;김옥배
    • Progress in Medical Physics
    • /
    • v.14 no.2
    • /
    • pp.99-107
    • /
    • 2003
  • This study was performed to prepare the verification film for localizing beam-target position with the Photon Knife radiosurgery system (PKRS) using linear accelerator(Mitsubishi, Model ML-15MDX). We developed a laser calibration system using a reticle of transparent lucite to detect Inlet and outlet beams. We verified fixation of the second collimator with film mounted on a holder in the shape of an octagon block 5cm apart from the isocenter. The film was exposed to photon beams of linear accelerator at an interval of 45 degrees during the gantry movement. There were no shifts in the beam of the second collimator during gantry movement. We used a position marker which is designed a head-shaped small lead block and a 10 mm in diameter of steel bead in the plastic tube. The position marker helped to verify the beam directions with patient position in multi-arc and trans-multi-arc of PKRS The verification of beam alignments showed an average 0.8$\pm$0.26 mm discrepancy in LINAC-gram images of PKRS. In our study, the couch movement was $\pm$5 mm laterally, while it shook $\pm$ 2 mm toward the couch axis. The couch, however, was immediately returned to the initial site after shaking. Thus, we postulate that the beam-target position(s) should be verified with LINAC-gram in a stereotactic radiosurgery system to achieve the accuracy of beam-target alignment.

  • PDF

A Study on Material Characteristics and Manufacturing Techniques for Gold-granule Beads Excavated from the Neungsan-ri Temple Site in Buyeo (부여 능산리사지 출토 금제구슬의 재료학적 특성 및 제작기법 연구)

  • Yang, Soohyeon;Ro, Jihyun
    • Conservation Science in Museum
    • /
    • v.26
    • /
    • pp.67-82
    • /
    • 2021
  • Two golden beads (Buyeo 5336) housed at the Buyeo National Museum were discovered in 1993 near the site of an ancient workshop in Neungsan-ri in Buyeo-gun, Chungcheongnam-do Province. These rare examples from the Baekje Kingdom of an application of granulation have maintained their original form intact, and thus serve as important materials for the investigation of production techniques applied. This study analyzed the composition of the golden beads using a portable X-ray fluorescence analyzer, a stereo microscope, and a scanning electron microscope with an energy dispersive X-ray spectrometer. The manufacturing technique was examined through the observation of the micro-shape and the surface condition and by a composition analysis of the joint part. In both beads, a hole was pierced in a hollow body and the bead was decorated with golden wires around the hole and gold granules in other parts. In some areas, golden granules had been attached to the gold plate and golden wires were then placed over the granules. The purity of both the wires and the granules was analyzed as 23.6 - 23.7K. A high copper content was detected in some of the parts where the granules were attached. The findings of a previous reproduction experiment and study of production methods suggest that the beads were made using the copper diffusion technique.

Structural and Photocatalytic Properties of TiO2 Thin Film Coated Glass Beads (유리알에 코팅된 TiO2 박막의 구조 및 광촉매 특성)

  • Ji Eun, Jeong;Chang-Yong, Lee
    • Applied Chemistry for Engineering
    • /
    • v.34 no.1
    • /
    • pp.30-35
    • /
    • 2023
  • The glass bead surface was coated using a TiO2 sol, after which dry-treated (TB) and calcined (TBc) samples were prepared. Photocatalytic degradation of methylene blue and toluene, as well as characterization of the TiO2 thin films, were carried out. The TiO2 thin film of the TB sample had the same shape as the sponge foam, according to FE-SEM, XPS, and FTIR analyses, and contained both amorphous and crystalline TiO2. On the other hand, crystalline TiO2 was mainly present in the TiO2 thin film of the TBc sample, and needle-shaped particles and tiny ones were mixed. The adsorption capacity for methylene blue and the degradation rate of the TBc sample were less than 10 % compared with those of the TB sample, and the adsorption capacity and degradation rate of the TBc sample decreased similarly as the amount of TiO2 coating increased. The amount of toluene adsorption for the TBc sample (46 mg/g) was smaller than that of the TB sample with the same coating amount, but the degradation rate was similar. In the case of the TB sample, the degradation rate for toluene decreased less than the adsorption capacity as the amount of TiO2 coating increased. This result is considered to be because, in the non-calcined TB sample, the active site reduction of the crystalline particles occurred less and the specific surface area of the amorphous texture decreased as the amount of TiO2 coating increased.

Spontaneous Passage of Gastrointestinal Foreign Bodies in Children (소아에서 위장관 이물의 자연 배출에 대한 경험적 고찰)

  • Lee, Ji-Hyuk;Nam, Suk-Hyun;Lee, Jee-Hyun;Lee, Hae-Jeong;Choe, Yon-Ho
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.10 no.2
    • /
    • pp.157-165
    • /
    • 2007
  • Purpose: Ingested foreign bodies are removed by endoscopy, surgery or spontaneous passage, however, the decision of therapeutic modality chosen depends on the type, size, shape and location of the ingested foreign bodies. Therefore, this study was conducted to investigate the rate and characteristics of foreign bodies that were passed spontaneously out of the intestine. Methods: One hundred and sixty patients who visited Samsung Medical Center for treatment of gastrointestinal foreign bodies between January 2001 to July 2007 were enrolled in this study. Related data was colleted by reviewing the medical records of patients with proven foreign bodies retrospectively, as well as by conducting phone interviews with the parents of the patients. All cases were classified based on the nature and location of the ingested foreign body, as well as whether it was treated by spontaneous passage. Results: Of the 160 cases involving the passage of foreign bodies in children were included in this study (95 boys and 65 girls), endoscopic removals, operative removals or spontaneous passages were conducted in 80, 3 and 77 patients, respectively. The spontaneous passage rates for each type of object were as follows; coins (36.5%), bead and baduk stones (83.3%), long and sharp materials (52.6%), magnets (69.2%) and disc batteries (50.0%). In cases involving round-shaped foreign bodies, such as coins, the diverse spontaneous passage rates were more diverse. When foreign bodies were stuck below esophagus, similar sized coins and baduk stones had spontaneous passage rates greater than 80% regardless of age. Conclusion: It is better for clinicians to wait for spontaneous passage to occur in cases involving coins or round-shaped foreign bodies that are located at or below the stomach.

  • PDF

Remediation of Heavy Metal Contaminated Groundwater by Using the Biocarrier with Dead Bacillus sp. B1 and Polysulfone (Bacillus sp. B1 사균과 Polysulfone으로 이루어진 미생물 담체를 이용한 중금속 오염 지하수 정화)

  • Lee, Min-Hee;Lee, Ji-Young;Wang, Soo-Kyun
    • Economic and Environmental Geology
    • /
    • v.43 no.6
    • /
    • pp.555-564
    • /
    • 2010
  • Remediation process by using the bio-carrier (beads) with dead Bacillus sp. B1 and polysulfone was investigated for heavy metal contaminated groundwater. Sorption batch experiments using the bio-carrier were performed to quantify the heavy metal removal efficiencies from the contaminated solution. The analyses using SEM/EDS and TEM for the structure and the characteristic of precipitates on/inside the beads were also conducted to understand the sorption mechanism by the bio-carrier. Various amounts of freeze-dried dead Bacillus sp. B1 were mixed with polysulfone + DMF(N,N-dimethylformamide) solution to produce the bio-carrier (beads; less than 2mm in diameter) and 5% of Bacillus sp. B1 in the bio-carrier was optimal for Pb removal in the solution. The removal efficiency ratings of the bio-carrier for Pb, Cu and Cd were greater than 80% after adding 2g of bio-carrier in 50ml of aqueous solution (<10mg/L of each heavy metal concentration). Reaction time of the bio-carrier was very fast and most of the sorption reaction for heavy metals were completed within few hours. Batch experiments were duplicated at various pH conditions of aqueous solutions and Cu and Pb removal efficiencies highly maintained at wide pH ranges (pH 2-12), suggesting that the bio-carrier can be useful to clean up the acidic waste water such as AMD. From SEM/EDS and TEM analyses, it was observed that the bio-carrier was spherical shape and was overlapped by many porous layers. During the sorption experiment, Pb was crystallized on the surface of porous layers and also was mainly concentrated at the boundary of Bacillus sp. B1 stroma and polysulfone substrate, showing that the main mechanism of the bio-carrier to remove heavy metals is the sorption on/inside of the bio-carriers and the bio-carriers are excellent biosorbents for the removal of heavy metal ions from groundwater.