• Title/Summary/Keyword: Battery Case

Search Result 390, Processing Time 0.033 seconds

A Study on Maintainability Improvement for Underwater Weapon Training Vehicle (수중무기 훈련탄의 정비성 향상방안 연구)

  • Jeong, Jinseob
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.16 no.2
    • /
    • pp.111-117
    • /
    • 2013
  • In this paper, we have proposed novel technique to improve maintainability for training vehicle of underwater weapon system. In case of under water weapon, the fire procedure is related with operation of expulsion system in submarines. So the submarine crews should practice the complex fire procedure of weapon system by using training vehicle, which is safer and cheaper than operational weapon. After emitted from submarine, the training vehicle rise to the surface and should be withdrawn from the sea. The recovered training vehicle is transported to maintenance depot and pass through the recycling procedure including disassembling the vehicle, data acquisition & analysis, battery charge, replacing expandable components, testing the captive equipment, and assembling the vehicle. The disassembling & assembling of training vehicle which is composed of watertight section or airframe, is time-consuming work. So in this paper, we have studied the elements of recycling procedure and propose the method to exclude the assembling & disassembling work for maintainability improvement.

A study of ALP for elevator (엘리베이터용 정전시 비상구출장치에 관한 연구)

  • Jang, C.H.;Lee, G.H.;Hur, H.J.;Lee, J.G.;Kim, H.J.;Choi, C.S.;Jeong, J.T.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07f
    • /
    • pp.2013-2015
    • /
    • 1997
  • Elevator stops emergently when power failures happen during operation. In that case, the passenger should wait with frightened in the car untill they are rescued by repair man or power resumes. This paper describes an automatic landing device for power-failure(ALP) that consists of UPS and battery charge control system. The excellence of the ALP operation is verified by experiments in elevator test tower.

  • PDF

A Study on the Insulation Resistance Measurement Technique for Electrical Safety of Green Car (친환경자동차의 전기안전을 위한 절연저항 측정에 관한 연구)

  • Lee, Ki-Yeon;Kim, Dong-Ook;Kim, Hyang-Kon;Moon, Hyun-Wook
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.597-601
    • /
    • 2009
  • Green car such as a hybrid electrical vehicle and fuel cell vehicle is developed as a commercial target. UN/ECE/WP29 is developing GTR of HFCV and establishing the regulation and standard of electrical safety by ELSA. The regulation and standard about Electrical safety of vehicle are prescribed in ISO, UN/ECE, FMVSS, Japanese Attachment and so on, in case of insulation resistance is referred to keep more than 100/Vdc, 500/Vac. However, accurate method to measure insulation resistance agreeable to structure of vehicle does not exist now, it is actually that correctness of measurement drops according to the feature of battery and fuel cell stack. In this paper, the method to measure insulation resistance for protection against electrical shock by direct contact or indirect contact in Green Car will be indicated by making a comparison between the insulation measurement in standard of electrical safety and the experiment results for HEV and HFCV.

A Stability Analysis of Bus Controller of Power Control Unit for GEO Satellite (정지궤도위성 전력조절장치 버스제어기 안정도해석)

  • Choi Jaedong
    • Proceedings of the KIPE Conference
    • /
    • 2004.07b
    • /
    • pp.874-877
    • /
    • 2004
  • This paper presents the bus controller analysis of a power control unit of GEO satellite with 3kW power output. The sensing error of bus voltage produce control signal of the shunt switch assembly and the battery power converter, and the tolerance of error signal generated decide the stability of proposed system. The worst case analysis considered for the initial tolerance, temperature effect, tolerance of end of life is peformed to verify a designed bus controller. And also, the stability of system proposed according to moving of zero and pole values by some component failures is analyzed.

  • PDF

THE ORIGIN OF LARGE SCALE GALACTIC MAGNETIC FIELDS

  • SUBRAMANIAN K.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.spc1
    • /
    • pp.155-158
    • /
    • 1996
  • Magnetic fields correlated on several kiloparsec scales are seen in spiral galaxies. Their origin could be due to the winding up of a primordial cosmological field or due to amplification of a small seed field by a turbulent galactic dynamo. Both options have difficulties: There is no known battery mechanism for producing the required primordial field. Equally the turbulent dynamo may self destruct before being able to produce the large scale field, due to excess generation of small scale power. The current status of these difficulties is discussed. The resolution could depend on the nature of the saturated field produced by the small scale dynamo. We argue that the small scale fields do not fill most of the volume of the fluid and instead concentrate into intermittent ropes, with their peak value of order equipartition fields, and radii much smaller than their lengths. In this case these fields neither drain significant energy from the turbulence nor convert eddy motion of the turbulence on the outer scale to wave like motion. This preserves the diffusive effects needed for the large scale dynamo operation.

  • PDF

A Study on the comparison of FEM and FEM for Backward Impact Extrusion Process (후방 충격압출 성형 공정의 FVM과 FEM의 적용성에 관한 연구)

  • 정상원;조규종;김성훈
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2003.06a
    • /
    • pp.1565-1568
    • /
    • 2003
  • The backward extrusion process is one of the commonly used metal forming processes. In this paper. a battery case which has the rectangular section, is analyzed using a 3D metal forming package(MSC.Superforge). This pacakge uses the finite volume analysis method. It is shown that the MSC.Superforge package using finite volume method provides result very close to those obtained from a finite element analysis package(MSC.Superform). However, the simulation time using the finite volume method was almost 10 % of the simulation time consumed by the other package using finite element method. Moreover, the finite volume method used in MSC.Superforge can eliminate the remeshing problems that make the simulating a metal forming process with severe deformation, such as the extrusion process, so difficult.

  • PDF

A Model for Degradation of $\beta$-$Al_2O_3$ Solid Electrolyte ($\beta$-$Al_2O_3$ 고체전해질의 퇴화모델)

  • 송효일;김응수;윤기현
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.5
    • /
    • pp.23-28
    • /
    • 1985
  • A model for degradation of $eta$-$Al_2O_3$ is derived from sress generated by Poiseuille pressure capillary effect and effulent flux in charging process of Na-S Battery. Critical current density for degradation increase with increasing the crack length and crack tip radius. radius 10-7cm and crack length 10-5cm Dependence of crack growth velocity on crack lengh is seperated two regions that is for a large crack length it is predominated by Poiseuille pressure and effulent fluex but in the case of small crack length it is controlled by capillary effect.

  • PDF

Quantitative Visualization of Inlet Flow of the Centrifugal Blower (원심 블로어 입구 유동의 정량적 가시화 연구)

  • Jeong, Tae-Sik;Tu, Xin Cheng;Kim, Sung-Jun;Jang, Hwan-Young;Kim, Jin-Kwang;Kim, Hyoung-Bum
    • Journal of the Korean Society of Visualization
    • /
    • v.11 no.2
    • /
    • pp.27-33
    • /
    • 2013
  • The inlet flow of centrifugal blower were quantitatively visualized using particle image velocimetry. Because the centrifugal blower system is one of the key parts of EV battery cooling system, the quantitative information of flow field of centrifugal blower is important to design and optimize the cooling system. Two types of inlet parts were used in this study. One is the straight inlet and the other is a bended one. The results showed the flow asymmetry exists in the straight model due to the pressure difference in the blower. In case of the bended one, the separation bubble and the increase of head loss appeared compared with the straight model.

A Study on FE Analysis For Improvement of Backward Impact Extrusion Process (후방 충격압출 공정개선을 위한 유한요소 해석기법 연구)

  • 정상원;정용호;김규하;조규종
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.641-645
    • /
    • 2002
  • In case of aluminum-cased battery, The ratio of height and base of square is generally above the ten times, square-shaped and problem of non-axis symmetry. It is typical model to set up the analysis method of finite element. The reliable analysis of finite element method is suggested, which is used to investigate the possibility that multi-stage deep drawing and ironing used currently is replaced by backward impact extrusion favorable in the respect of cost production and productivity. The influence of parameter was analyzed and compared, which was considered to analyze the process of large deformation plasticity such as extrusion. Die and billet was made as the same shape of finite element model. The results of experiment show good forming without the rupture and wrinkles with the optimum velocity 100mm/sec obtained by analysis.

  • PDF

Case Based Diagnosis Modeling of Dark Current Causes and Standardization of Diagnosis Process (사례기반의 암전류 원인 진단 모델링 및 표준화)

  • Jo, Haengdeug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.25 no.2
    • /
    • pp.149-156
    • /
    • 2017
  • Various kinds of accessories(e.g., clock, radio, automatic door locks, alarm devices, etc.) or unit components (e.g., black box, navigation system, alarm, private audio, etc.) require dark current even when the vehicle power is turned off. However, accessories or unit components can be the causes of excessive dark current generation. It results in battery discharge and the vehicle's failure to start. Therefore, immediate detection of abnormal dark current and response are very important for a successful repair job. In this paper, we can increase the maintenance efficiency by presenting a standardized diagnostic process for the measurement of the dark current and the existing problem. As a result of the absence of a system to block the dark current in a vehicle, diagnosis and repair were performed immediately by using a standardized dark current diagnostic process.