• 제목/요약/키워드: Bath temperature

검색결과 581건 처리시간 0.024초

Cu pyrophosphate bath에서 전기도금된 Cu 박막에 미치는 전류밀도 및 도금온도의 영향 (Effects of Current Density and Solution Temperature on Electrodeposited Cu Thin Film in Cu Pyrophosphate Bath)

  • 심철용;신동율;구본급;박덕용
    • 한국표면공학회:학술대회논문집
    • /
    • 한국표면공학회 2012년도 추계총회 및 학술대회 논문집
    • /
    • pp.136-136
    • /
    • 2012
  • Cu 박막이 pyrophosphate baths로부터 전기도금공정에 의해 제조되었으며, 전류밀도 및 도금온도가 Cu 박막의 특성에 미치는 영향을 조사하였다. 전류 밀도 및 도금온도 모두 전류효율, 잔류응력, 표면형상, 미세조직에 상당한 영향을 미쳤음을 알 수 있었다.

  • PDF

외부 환경 변화에 의한 비 접촉 체온계의 오차 범위 측정 (Investigation of Standard Error Range of Non-Contact Thermometer by Environment)

  • 김정은;박상웅;최혜경
    • 대한통합의학회지
    • /
    • 제8권4호
    • /
    • pp.307-321
    • /
    • 2020
  • Purpose : A person infected by SARS-CoV2 may present various symptoms such as fever, pain in lower respiratory tract, and pneumonia. Measuring body temperature is a simple method to screen patients. However, changes in the surrounding environment may cause errors in infrared measurement. Hence, a non-contact thermometer controls this error by setting a correction value, but it is difficult to correct it for all environments. Therefore, we investigate device error values according to changes in the surrounding environment (temperature and humidity) and propose guidelines for reliable patient detection. Methods : For this study, the temperature was measured using three types of non-contact thermometers. For accurate temperature measurement, we used a water bath kept at a constant temperature. During temperature measurement, we ensured that the temperature and humidity were maintained using a thermo-hygrometer. The conditions of the surrounding environment were changed by an air conditioner, humidifier, warmer, and dehumidifier. Results : The temperature of the water bath was measured using a non-contact thermometer kept at various distances ranging from 3~10 cm. The value measured by the non-contact thermometer was then verified using a mercury thermometer, and the difference between the measured temperatures was compared. It was observed that at normal surrounding temperature (24 ℃), there was no difference between the values when the non-contact thermometer was kept at 3 cm. However, as the distance of the non-contact thermometer was increased from the water bath, the recorded temperature was significantly different compared with that of mercury thermometer. Moreover, temperature measurements were conducted at different surrounding temperatures and the results obtained significantly varied from when the thermometer was kept at 3 cm. Additionally, it was observed that the effect on temperature decreases with an increase in humidity Conclusion : In conclusion, non-contact thermometers are lower in lower temperature and dry weather in winter.

Chemical Bath Deposition 방법으로 CdSe 박막 성장과 광센서 특성 (Photosensor of properties for CdSe thin film grown by Chemical Bath Deposition Method)

  • 홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 반도체 재료 센서 박막재료 전자세라믹스
    • /
    • pp.1-4
    • /
    • 2004
  • Polycrystalline CdSe thin films were grown on ceramic substrate using a chemical bath deposition(CBD)method. They were annealed at various temperature and X-ray diffraction patterns were measured by X-ray diffractometer in order to study CdSe polycrystal structure. Using extrapolation method of X-ray diffraction patterns for the CdSe samples annealed in $N_2$ gas at $450^{\circ}C$ it was found hexagonal structure whose lattice parameters $a_0$ and $c_0$ were $4.302{\AA}$ and 7.014 ${\AA}$, respectively. Its grain size was about 0.3 ${\mu}m$. Hall effect on this sample was measured by Van der Pauw method and studied on carrier density and movility depending on temperature. From Hall data, the mobility was likely to be decreased by piezo electric scattering at temperature range of 33K and 200K, and by polar optical scattering at temperature range of 200K and 293K. We measured also spectral response, sensitivity$(\gamma)$, maximum allowable power dissipation and response time on these samples.

  • PDF

이반응형 브리지 화합물을 이용한 폴리에스테르/면 복합소재의 단일분산염료염색 (I) (The Disperse Dyeing of Polyester/Cotton Blend Using a Hetero-bifunctional Bridge Compound (I))

  • 김태경;윤석한;김미경
    • 한국염색가공학회지
    • /
    • 제18권3호
    • /
    • pp.1-9
    • /
    • 2006
  • In order to dye polyester/cotton blend fabric by one-bath dyeing process with single disperse dye, a novel hetero-bifunctional bridge compound(DBDCBS) was synthesized and utilized. The DBDCBS was designed to contain two different reactive groups such as ${\alpha},{\beta}$-dibromopropionylamido and dichloro-s-triazinyl groups. The ${\alpha},{\beta}$-dibromopropionylamido group shows considerable reactivity towards amines or amino groups at acidic condition and high temperature. In contrast, the dichloro-s-triazinyl group has reactivity towards hydroxyl groups at alkaline condition and room temperature. In order to examine whether as a bridge the compound could combine dyes containing amino groups with cellulosic substrates, disperse dyes containing amino group were tried to dye the cotton fibers pretreated with the DBDCBS compound. By the results, polyester/cotton blends were dyed by one-bath dyeing process with single disperse dye,1,4-diaminoanthraquinone.

Characterization of vanadium carbide coating deposited by borax salt bath process

  • Aghaie-Khafri, M.;Daemi, N.
    • Advances in materials Research
    • /
    • 제1권3호
    • /
    • pp.233-243
    • /
    • 2012
  • Thermal reactive diffusion coating of vanadium carbide on DIN 2714 steel substrate was performed in a molten borax bath at $950-1050^{\circ}C$. The coating formed on the surface of the substrate had uniform thickness ($1-12{\mu}m$) all over the surface and the coating layer was hard (2430-2700 HV), dense, smooth and compact. The influence of the kinetics parameters, temperature and time, has been investigated. Vanadium carbide coating was characterized by scanning electron microscopy (SEM), energy dispersive X-ray spectrometry (EDX) and X-ray diffraction analysis (XRD). The corrosion resistance of the coating was evaluated by potentiodynamic polarization in 3.5% NaCl solution. The results obtained showed that decrease of coating microhardness following increasing time and temperature is owing to the coarsening of carbides and coating grain size.

Chemical Bath Deposition 방법으로 성장된 CdSe 박막의 광전도셀 특성 (Growth and optical properties for CdSe thin film by Chemical Bath Deposition Method)

  • 유상하;홍광준
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2006년도 추계학술대회 논문집 Vol.19
    • /
    • pp.75-76
    • /
    • 2006
  • olycrystailine CdSe thin films were grown on ceramic substrate using a chemical bath deposition (CBD)method. They were annealed at various temperature and X-ray diffraction patterns were measured by X-ray diffractometer in order to study CdSe polycrystal structure. Its grain size was about 0.3 ${\mu}m$. Hall effect on this sample was measured by Van der Pauw method and studied on carrier density and movility depending on temperature. We measured also spectral response, sensitivity($\gamma$), maximum allowable power dissipation and response time on these samples.

  • PDF

화학적으로 증착된 CdS 박막의 반응온도에 따른 물성 (Effect of Reaction Temperature on Properties of CdS Thin Films Prepared by Chemical Bath Deposition)

  • 송우창
    • 한국표면공학회지
    • /
    • 제38권3호
    • /
    • pp.112-117
    • /
    • 2005
  • In this paper, CdS thin films, which were widely used as a window layer of the CdS/CdTe and the $CdS/CuInSe_2$heterojunction solar cell, were grown by chemical bath deposition, and the structural, optical and electrical properties of the films on reaction temperatures were investigated. Cadmium acetate and thiourea were used as cadmium and sulfur source, respectively. And Ammonium acetate was used as the buffer solution. As the reaction temperatures were increased, the deposition rate of CdS fllms prepared by CBD was increased and the grain size was large due to increasing reaction rate in solution, also optical transmittance of the films in visible lights was increased on rising reaction temperatures.

목욕시설에서 발생한 열사병의 임상양상 및 열사병의 다발성 주요 합병증에 관한 예측인자 분석 (Clinical characteristics of heat stroke in bath facilities, and analysis of predictive factors of multiple major complications)

  • 박석진;현성열;임용수;조진성;민경진;양혁준
    • 대한응급의학회지
    • /
    • 제29권5호
    • /
    • pp.500-508
    • /
    • 2018
  • Objective: The aim of this study was to evaluate the clinical characteristics of heat stroke in a bath facility and investigate predictive factors of multiple major complications in heat stroke patients. Methods: This was a retrospective study on heat stroke patients who visited an urban emergency center from January 2010 to March 2018. We compared clinical characteristics, complication, and outcomes of heat stroke patients in bath and non-bath facilities. Multivariate logistic regression analysis were performed to identify independent predictors of multiple major complications in heat stroke patients. Results: A total of 67 heat stroke patients with heat stroke were enrolled, of which 42 (62.6%) were in a bath facility and 25 (37.3%) were in a non-bath facility. Patients with heat stroke in the bath facility were characterized by old age, past medical history of hypertension and diabetes mellitus, and high incidence of hypotension compared with those in the non-bath facility but also low incidence of acute renal failure, seizure, and multiple major complications. In the multivariate analysis, predictive factors of multiple major complications in heat stroke patients were non-bath facility (odds ratio [OR], 5.4; 95% confidence interval [CI], 1.2-29.9), Glasgow Coma Scale (GCS)${\leq}8$ (OR, 8.2; 95% CI, 1.3-49.4), and mean arterial pressure (MAP), body temperature above $40.5^{\circ}C$ (OR, 8.1; 95% CI, 1.1-58.8) <60 mmHg (OR, 14.8; 95% CI, 1.8-122.9). Conclusion: Heat stroke in the bath facility resulted in less major complications, and high body temperature, GCS ${\leq}8$, and MAP <60 mmHg were independent predictive factors of multiple major complications in heat stroke patients.

한약재 약욕요법이 소아 발열기간에 미치는 영향 : 체계적 문헌고찰 및 메타분석 (Effect of Herbal Bath for Duration of Pediatric Fever : a Systematic Review and Meta-analysis)

  • 김예지;박소현;서혜선;박슬기;이선행;이진용
    • 대한한방소아과학회지
    • /
    • 제35권3호
    • /
    • pp.53-66
    • /
    • 2021
  • Objective The purpose of this study is to evaluate whether herbal bath shortens the duration of pediatric fever. Methods Databases, such as Medline, EMBASE, Cochrane library, OASIS, KISS, KMBASE, CNKI, Wanfang Med Online were used to search randomized controlled trials. Those trials that included children younger than 18-year-old were evaluated for the clinical efficacy of herbal bath in fever by analyzing 'body temperature (BT) drop start time' and 'time to return to normal BT'. Results 12 studies or 1306 participants were analyzed in the study. When applying herbal bath in combination with the controlled treatment, 'BT drop start time' was decreased by 0.11 hours, and 'time to return to normal BT' was decreased by 10.94 hours compared to the controlled group. When comparing herbal bath with tepid bath, 'time to return to normal BT' was reduced by 8.19 hours in herbal bath group. In regards to safety, 3 studies out of 12 studies mentioned about its adverse events: 2 studies did not have any adverse events, and a minor needle-shaped bleeding had occurred in one of the studies. Conclusion Use of herbal bath as a treatment of fever in children was associated with shortened duration of fever. However, cautious interpretation is necessary due to its limited safety data.

붕산처리(硼酸處理) 합판(合板)의 열판건조(熱板乾燥) 및 동적(動的) 탄성율(彈性率)에 관(關)한 연구(硏究) (Studies on Press Drying and Dynamic Elastic Modulus of Plywood Treated with Boric Acid)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제15권3호
    • /
    • pp.56-67
    • /
    • 1987
  • Plywoods used for construction as a decorative interior material are inflammable and can make fire accidents, causing destruction of human life and property. Therefore, it is indeed required to make fire-retardant treated plywood. In this study, 3.7mm yellow meranti plywoods were soaked in 18% boric acid solutions and tap water by hot-cold bath for 1/2, 2/2, 4/2, 6/2 hours and redrying of treated plywoods was carried out by press drying at the platen temperature of 110, 130, 160, $180^{\circ}C$ and then it was conducted to investigate solution absorption, drying rates, dynamic young's modulus. specific gravity and fire-retardant factors such as burning point, flame spread length. flame exhausted time, back side carbonized area and weight loss by treating time, treating solutions and platen temperature. The results are as follows; 1. When plywood was impregnated with the hot bath temperature of $70^{\circ}C$ for 1. 2, 4, 6 hours and the cold bath temperature of $15^{\circ}C$ for 2 hours respectively, retentions of boric acid were 1.565, l.597, 1.643, 1.709kg/$(30cm)^3$ and all of them exceeded the minimum retention [1.125kg/$(30cm)^3$] even in the shortest treatment. 2. In hot-cold bath method for 1/2 hours, the drying rates of treated plywood remarkably increased with the extension of platen temperature of 110, 130, 160, $180^{\circ}C$ and the values of boric acid treated plywood were 5.900, 10.196, 45.42, 54.958m.c%/min and the values of water treated plywood were 6.014, 12.373, 46.520, 55.730m.c%/min and drying rates of water treated plywood were faster than those of boric acid treated plywood. 3. The values of boric acid treated plywoods in dynamic young's modulus were widely higher than those of water treated plywoods. And it can be observed that there were highly significant differences for treating time between dynamic young's modulus, and the values of boric acid plywoods increased with the extension of treating time but on the contrary water treated plywoods were decreased values with prolonged time 4. It was observed that there were highly significant differences for platen temperature between dynamic young's modulus. When the values of water treated plywoods in dyna nic young's modulus were abruptly decreased according to the rise of platen temperature. boric acid treated plywoods showed rather increased values at $160^{\circ}C$ of platen temperature. And in 2- way interactions, there were also highly significant for dynamic young's modulus between treating time x treating solutions and platen temperature x treating solutions. 5. Correlation coefficients of fire-retardant factors were shown in table 5. It could be recognized that there were close correlations between the treating solutions and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, but there was no correlation between fire-retardant factors and treating time and platen temperature. 6. From table 6, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carbonized area, weight loss between treating solutions. And in 2-way interactions, there were highly significant for burning point, flame spread length, weight loss between treating time $\times$ treating solutions.

  • PDF