• Title/Summary/Keyword: Base shear force

Search Result 155, Processing Time 0.03 seconds

Relationships between Antioxidants and Quality Characteristics from Velvet Antlers of Formosan Sambar Deer

  • Cheng, Shih-Lin;Jian, You-Ling;Chen, Chih-Ming;Liu, Bing-Tsan
    • Food Science of Animal Resources
    • /
    • v.37 no.4
    • /
    • pp.542-551
    • /
    • 2017
  • The quality characteristics of velvet antlers obtained from Formosan sambar deer (Cervus unicolor Swinhoi) (SDVA), harvested from 63 to 81 d during the velvet antler growth period, were evaluated by investigating the relationships between antioxidant levels; including content, activity, and content/activity ratios, and physical properties; including shear force values, color, and Ca content. The hardness of samples from base velvet antler sections increased, and that the color of these samples tended to become reddish-yellow (redder and more yellow), suggesting that the Ca content in the base section of the sample was not ossified yet. Samples from the upper sections of velvet antler showed higher superoxide dismutase (SOD), catalase (CAT), and glutathione peroxidase (GPX) content (3.91 to 1.50 mg/mL, 2.53 to 0.90 mg/mL, and 3.95 to 1.58 mg/mL, respectively) than did samples from the middle and base sections (p<0.05). The activity and content/activity ratios of GPX measured in the upper section were also found to be significantly greater than in the middle and base sections (p<0.05). We further observed that the content and activity of GPX was significantly and negatively correlated with Ca content, shear force values, and the content/activity ratio of this antioxidant (p<0.01). The study findings may serve as a reference index for quality evaluations of velvet antlers of Formosan sambar deer in future.

Prediction of engineering demand parameters for RC wall structures

  • Pavel, Florin;Pricopie, Andrei
    • Structural Engineering and Mechanics
    • /
    • v.54 no.4
    • /
    • pp.741-754
    • /
    • 2015
  • This study evaluates prediction models for three EDPs (engineering demand parameters) using data from three symmetrical structures with RC walls designed according to the currently enforced Romanian seismic design code P100-1/2013. The three analyzed EDPs are: the maximum interstorey drift, the maximum top displacement and the maximum shear force at the base of the RC walls. The strong ground motions used in this study consist of three pairs of recordings from the Vrancea intermediate-depth earthquakes of 1977, 1986 and 1990, as well as two other pairs of recordings from significant earthquakes in Turkey and Greece (Erzincan and Aigion). The five pairs of recordings are rotated in a clockwise direction and the values of the EDPs are recorded. Finally, the relation between various IMs (intensity measures) of the strong ground motion records and the EDPs is studied and two prediction models for EDPs are also evaluated using the analysis of residuals.

Control Effectiveness of Shear Walls Connected by Beams with Friction Dampers (인방보에 마찰형 감쇠기가 설치된 전단벽의 제진효과)

  • Chung, Hee-San;Min, Kyung-Won
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.22 no.1
    • /
    • pp.105-115
    • /
    • 2009
  • Numerical analysis of shear walls governed by flexural behavior is conducted for the seismic control performance of proposed friction dampers installed at the center of coupling beams. Control effectiveness of shear walls connected by beams with the proposed dampers are compared for single shear wall with same flexural rigidity. Average responses of the shear walls with the dampers are found with seven scaled-downed earthquakes based on KEC 2005 design spectrum. Slip load is the most important design parameter. It is designed to be 5, 10, 20, 30, 60, 90% of total vertical shear force at damper location to prevent damper slip in specific stories. Nonlinear time-history analysis is conducted by using SeismoStruct analysis program. Seismic control performance of the dampers is evaluated for base shear, energy dissipation, curvature and top-floor displacement. Results show that the dampers are the most effective in reducing the responses when their total slip load is 30% of total vertical shear force.

High-frequency force balance technique for tall buildings: a critical review and some new insights

  • Chen, Xinzhong;Kwon, Dae-Kun;Kareem, Ahsan
    • Wind and Structures
    • /
    • v.18 no.4
    • /
    • pp.391-422
    • /
    • 2014
  • The high frequency force balance (HFFB) technique provides convenient measurements of integrated forces on rigid building models in terms of base bending moments and torque and/or base shear forces. These base moments or forces are then used to approximately estimate the generalized forces of building fundamental modes with mode shape corrections. This paper presents an analysis framework for coupled dynamic response of tall buildings with HFFB technique. The empirical mode shape corrections for generalized forces with coupled mode shapes are validated using measurements of synchronous pressures on a square building surface from a wind tunnel. An alternative approach for estimating the mean and background response components directly using HFFB measurements without mode shape corrections is introduced with a discussion on higher mode contributions. The uncertainty in the mode shape corrections and its influence on predicted responses of buildings with both uncoupled and coupled modal shapes are examined. Furthermore, this paper presents a comparison of aerodynamic base moment spectra with available data sets for various tall building configurations. Finally, e-technology aspects in conjunction with HFFB technique such as web-based on-line analysis framework for buildings with uncoupled mode shapes used in NALD (NatHaz Aerodynamic Loads Database) is discussed, which facilitates the use of HFFB data for preliminary design stages of tall buildings subject to wind loads.

Experimental Study on Seismic Behavior of Roof Joint

  • Cui, Yao;Gao, Xiaoyu;Liu, Hongtao;Yamada, Satoshi
    • International journal of steel structures
    • /
    • v.18 no.4
    • /
    • pp.1373-1383
    • /
    • 2018
  • Experimental study was conducted to investigate the seismic behavior of roof joint. Eight full-scale specimens were tested considering the effects of axial force, joint height, hole shape of base plate and edge distance of concrete on the failure mode and resistance capacity of roof joint. With the increase of axial force, the hysteretic curves were fuller. The mechanical model of roof joint change from bending to shear. With the increase of joint height, the ultimate strength of roof joint decreased. If the hole shape of base plate changed from circle to loose, the slip behavior of roof joint appeared and the ultimate strength of roof joint decreased. The damage of edge concrete may occur if the edge distance of concrete was not big enough.

Seismic Behavior Evaluation of Unreinforced Masonry Structure Considering Soil-Structure Interaction (지반-구조물 상호작용을 고려한 비보강 조적조 구조물의 지진거동평가)

  • 김희철;김관중;홍원기
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.4
    • /
    • pp.9-16
    • /
    • 2001
  • The purpose of this study is to evaluate a seismic behavior of unreinforced masonry(URM) structure. For more efficient evaluation, quasi-dynamic analysis method is used in this study. The influence of soil-structure interaction on the seismic response of low rise structures is discussed through comparison of the computed seismic response for the structure on rigid or dense soil and that on soft soil. The results of analytical study show that the story shear forces and the base shear forces could increase on soft soil. Furthermore, it was observed that an approximate expressions prescribed in current seismic codes may underestimate the value of the base shear force of low rise buildings on soft soil.

  • PDF

Shear bond strength of veneering porcelain to zirconia and metal cores

  • Choi, Bu-Kyung;Han, Jung-Suk;Yang, Jae-Ho;Lee, Jai-Bong;Kim, Sung-Hun
    • The Journal of Advanced Prosthodontics
    • /
    • v.1 no.3
    • /
    • pp.129-135
    • /
    • 2009
  • STATEMENT OF PROBLEM. Zirconia-based restorations have the common technical complication of delamination, or porcelain chipping, from the zirconia core. Thus the shear bond strength between the zirconia core and the veneering porcelain requires investigation in order to facilitate the material's clinical use. PURPOSE. The purpose of this study was to evaluate the bonding strength of the porcelain veneer to the zirconia core and to other various metal alloys (high noble metal alloy and base metal alloy). MATERIAL AND METHODS. 15 rectangular ($4\times4\times9mm$) specimens each of zirconia (Cercon), base metal alloy (Tillite), high noble metal alloy (Degudent H) were fabricated for the shear bond strength test. The veneering porcelain recommended by the manufacturer for each type of material was fired to the core in thickness of 3mm. After firing, the specimens were embedded in the PTFE mold, placed on a mounting jig, and subjected to shear force in a universal testing machine. Load was applied at a crosshead speed of 0.5mm/min until fracture. The average shear strength (MPa) was analyzed with the oneway ANOVA and the Tukey's test ($\alpha$= .05). The fractured specimens were examined using SEM and EDX to determine the failure pattern. RESULTS. The mean shear strength ($\pm\;SD$) in MPa was 25.43 ($\pm\;3.12$) in the zirconia group, 35.87 ($\pm\;4.23$) in the base metal group, 38.00 ($\pm\;5.23$) in the high noble metal group. The ANOVA showed a significant difference among groups, and the Tukey' s test presented a significant difference between the zirconia group and the metal group. Microscopic examination showed that the failure primarily occurred near the interface with the residual veneering porcelain remaining on the core. CONCLUSION. There was a significant difference between the metal ceramic and zirconia ceramic group in shear bond strength. There was no significant difference between the base metal alloy and the high noble metal alloy.

Effect of Retention System on the Characteristics of Floc and Retention (보류 시스템이 Floc 특성과 보류에 미치는 영향)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.33 no.3
    • /
    • pp.9-17
    • /
    • 2001
  • The floc characteristics of base paper stock for coating by the retention aid system consisting of polyacrylamide (high molecular weight low charge density, HMLC) and PEI without and with anionic inorganic oxide (IO) were investigated under various shear conditions of MDDA (modified dynamic drainage analyzer). The floc size was increased with cationic electrolytes dosage whatever inorganic oxide is applied or not. The effect of inorganic oxide on the floc size showed the different result between PAM and PEI. The smaller floc was obtained by PAM without inorganic oxide, but larger floc was obtained by PAM with inorganic oxide. However, the effect of shear force was not observed. Floc formation index was decreased by the addition of cationic electrolytes with or without inorganic oxide. Floc formation index had better correlation format formation index than floc size. The relationships between wet web permeability and mat air permeability showed the significant linear correlation ($R^2$=0.97~0.98) for HML PAM and PEI. Floc formation index gave more useful information than the retention measurement when the performance of retention aids is evaluated at the laboratory before applying at the paper mill.

  • PDF

Seismic responses of asymmetric steel structures isolated with the TCFP subjected to mathematical near-fault pulse models

  • Tajammolian, H.;Khoshnoudian, F.;Bokaeian, V.
    • Smart Structures and Systems
    • /
    • v.18 no.5
    • /
    • pp.931-953
    • /
    • 2016
  • In this paper, the effects of mass eccentricity of superstructure as well as stiffness eccentricity of isolators on the amplification of seismic responses of base-isolated structures are investigated by using mathematical near-fault pulse models. Superstructures with 3, 6 and 9 stories and aspect ratios equal to 1, 2 and 3 are mounted on a reasonable variety of Triple Concave Friction Pendulum (TCFP) bearings considering different period and damping ratio. Three-dimensional linear superstructure mounted on nonlinear isolators are subjected to simplified pulses including fling step and forward directivity while various pulse period ($T_p$) and Peak Ground Velocity (PGV) amounts as two crucial parameters of these pulses are scrutinized. Maximum isolator displacement and base shear as well as peak superstructure acceleration and drift are selected as the main engineering demand parameters. The results indicate that the torsional intensification of different demand parameters caused by superstructure mass eccentricity is more significant than isolator stiffness eccentricity. The torsion due to mass eccentricity has intensified the base shear of asymmetric 6-story model 2.55 times comparing to symmetric one. In similar circumstances, the isolator displacement and roof acceleration are increased 49 and 116 percent respectively in the presence of mass eccentricity. Furthermore, it is demonstrated that torsional effects of mass eccentricity can force the drift to reach the allowable limit of ASCE 7 standard in the presence of forward directivity pulses.

A Study on the Properties in Friction Weldability of Ni-Cr-Mo and SM45C (Ni-Cr-Mo과 SM45C의 마찰용접특성(摩擦熔接特性)에 관한 연구(硏究))

  • Lim, Hyung-Taek;Min, Taeg-Ki
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.29-36
    • /
    • 2007
  • The present study examined the mechanical properties of the friction welding of Ni-Cr-Mo to SM45C. Friction welding was conducted at welding conditions of 2,000 rpm, friction pressure of 100MPa, friction time of 0.8, 1.0, 1.2, 1.4, 1.6, 1.8, 2.0 seconds, upset pressure of 150MPa, and upset time of 3.0 seconds. When the friction time was 1.6 seconds, the maximum tensile strength of the friction weld happened to be 1,020MPa, which is 120% of the base material's tensile strength(850MPa). At the same condition, the maximum shear strength was 438MPa, which is equivalent to 103% of the base material's shear strength(425MPa). At the same condition, the maximum vickers hardness was Hv490 at Ni-Cr-Mo nearby weld interface, which is higher Hv40 than condition of the friction time 0.8 seconds, and the maximum vickers hardness was Hv305 from weld interface of SM45C, which is higher Hv12 than condition of the friction time 0.8 seconds. The results of microstructure analysis show that the structures of two base materials have fined and rearranged along a column due to heating and axial force during friction, which has affected in raising hardness and tensile strength.