• Title/Summary/Keyword: Base disturbance

Search Result 97, Processing Time 0.022 seconds

A Study on the Structure Characteristics of Planting Ground in Incheon International Airport, Korea (인천국제공항 식재기반 구조 및 토양특성 연구)

  • Lee, Seung-Won;Han, Bong-Ho;Lee, Kyong-Jae;Kwak, Jeong-In;Yeum, Jung-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.3
    • /
    • pp.77-91
    • /
    • 2015
  • This study aims to suggest adequate soil management through the analysis of physicochemical properties of soil in the planting grounds of Incheon International Airport, which was constructed on a massive land reclamation site. Study areas were 5 sites at the international business complex, the passenger terminal, the airport support complex, the free trade zone, and the access road. Soil profile analysis showed that 9 plots out of the 27 plots were hardpan and heterospere within 80cm from the soil surface. The earth laid on the ground was categorized as gravel based soil(4 plots), dredged soil from the sea bottom and mixed reclamation materials(2 plots), clay with poor permeability(3 plots) and waste construction material(1 plot). Average soil hardness was $11.5kg/cm^2$ and soil textures were sandy soil, sandy loam and loamy sand. Average soil pH was 6.7 and average organic matter content was 0.7%. Electrical conductivity was 0.0dS/m and exchangeable cation concentrations were $Ca^{2+}$ 3.4cmol/kg, $Mg^{2+}$ 1.5cmol/kg, $K^+$ 0.3cmol/kg and $Na^+$ 1.0cmol/kg. Average cation exchange capacity was 11.0cmol/kg. Although average figures in Solum mostly meet the landscape design criteria, properties of each soil layer showed various values sometimes over the limit. Base saturations were $Ca^{2+}$ 29.9%, $Mg^{2+}$ 13.3% and $K^+$ 3.7% for lower soil, $Ca^{2+}$ 33.3%, $Mg^{2+}$ 17.0% and $K^+$ 2.7% for mid-soil and $Ca^{2+}$ 32.6%, $Mg^{2+}$ 12.2% and $K^+$ 1.9% for upper soil. Exchangeable sodium percentages were 16.4% for lower soil, 7.5% for mid-soil and 4.7% upper soil. Sodium adsorption rates were 0.8 for lower soil, 0.3 for mid-soil and 0.2 for upper soil. Factors affecting to the vegetation growth were heterogeneity and poorness of solum, disturbance of dredged soils, high soil hardness including hardpan in the subsurface soil layer and shallow effective soil depth, high soil acidity, imbalance of base contents, low organic matter content and low available phosphate levels in the soil.

Quaternary Geology and Paleoecology of Hominid Occupation of Imjin Basin (임진강유역 구석기 공작의 고생태학적 배경)

  • Seonbok Yi
    • The Korean Journal of Quaternary Research
    • /
    • v.2 no.1
    • /
    • pp.25-50
    • /
    • 1988
  • The survival of rich evidence of palaeolithic occupation found in the Imjin-Hant'an River basin was possible due to many fortuitous geological conditions provided there. Formation of the basalt plain in a narrow valley system which developed during the late Mesozoic insured the appearance of a basin of sedimentation in which archaeological sites would be preserved with relatively minor post-depositional disturbance. Geomagnetic and K-Ar dating indicates that lava flows occurred during the Brunes Normal Epoch. During and after the process of basin sedimentation, erosion of the plain was confined to the major channel of the present river system which developed along the structural joints formed by the lava flow. Due to characteristic columnar structure and platy cleavage of the basalt bedrock, erosion of the basalt bedrock occurred mainly in vertical direction, developing deep but narrow entrenched valleys cut into the bedrock. Consequently, the large portion of the site area remained intact. Cultural deposits formed on top of the basalt plain were left unmodified by later fluvial disturbances due to changes in the Hant'an River base-level, since they were formed about 20 to 40m above the modern floodplain. Sedimentological evidence of cultural deposits and palynological analysis of lacustrine bed formed in the tributary basin of the Hant'an River indicate that hominid occupation occurred in this basin under rapidly deteriorating climatic conditions. From three thermoluminescence dates, the timing of hominid occupation as represented by 'Acheulian-like' bifaces apparently occur sometime during 45,000 BP. Thus, deposition of cultural layers in this basin approximately coincides with the beginning of the second stadial of the final glacial, during which the Korean Peninsula must have had provided a sanctuary for prolonged human occupation.

  • PDF

Permission of the Claim that Prohibits Military Aircraft Operation Nearby Residential Area - Supreme Court of Japan, Judgement Heisei 27th (Gyo hi) 512, 513, decided on Dec. 8, 2016 - (군사기지 인근주민의 군용기 비행금지 청구의 허용 여부 - 최고재(最高裁) 2016. 12. 8. 선고 평성(平成) 27년(행(行ヒ)) 제512, 513호 판결 -)

  • Kwon, Chang-Young
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.33 no.1
    • /
    • pp.45-79
    • /
    • 2018
  • An increase of airplanes and military aircraft operation lead to significant demanding of residential claims by people who live in nearby airports and military bases due to noise, vibration and residential damages caused by aircraft operations. In recent years, a plaintiff has filed a lawsuit against the defendant, claiming the prohibition of using claimant's possessed land as a helicopter landing route, and the Daejeon High Court was in favour of the plaintiff. Although the Supreme Court later dismissed the Appeal Court decision, it is necessary to discuss the case of setting flight prohibited zone. In Japan, the airport noise lawsuits have been filed for a long time, mainly by environmental groups. Unlike the case that admitted residential damages caused by noise, the Yokohama District Court for the first time sentenced a judgment of the prohibition of the flight. This ruling was partially changed in the appellate court and some of the plaintiffs' claims were adopted. However, the Supreme Court of Japan finally rejected such decision from appeal and district courts. Atsugi Base is an army camp jointly used by the United States and Japan, and residents, live nearby, claim that they are suffering from mental damage such as physical abnormal, insomnia, and life disturbance because of the noise from airplane taking off and landing in the base. An administrative lawsuit was therefore preceded in the Yokohama District Court. The plaintiff requested the Japan Self-Defense Forces(hereinafter 'JSDF') and US military aircraft to be prohibited operating. The court firstly held the limitation of the flight operation from 10pm to 6am, except unavoidable circumstance. The case was appealed. The Supreme Court of Japan dismissed the original judgment on the flight claim of the JSDF aircraft, canceled the first judgment, and rejected the claims of the plaintiffs. The Supreme Court ruled that the exercise of the authority of the Minister of Defense is reasonable since the JSDF aircraft is operating public flight high zone. The court agreed that noise pollution is such an issue for the residents but there are countermeasures which can be taken by concerned parties. In Korea, the residents can sue against the United States or the Republic of Korea or the Ministry of National Defense for the prohibition of the aircraft operation. However, if they claim against US government regarding to the US military flight operation, the Korean court must issue a dismissal order as its jurisdiction exemption. According to the current case law, the Korean courts do not allow a claimant to appeal for the performance of obligation or an anonymous appeal against the Minister of National Defense for prohibiting flight of military aircraft. However, if the Administrative Appeals Act is amended and obligatory performance litigation is introduced, the claim to the Minister of National Defense can be permitted. In order to judge administrative case of the military aircraft operation, trade-off between interests of the residents and difficulties of the third parties should be measured in the court, if the Act is changed and such claims are granted. In this connection, the Minister of National Defense ought to prove and illuminate the profit from the military aircraft operation and it should be significantly greater than the benefits which neighboring residents will get from the prohibiting flight of military aircraft.

The Correlation between HRCT Emphysema Score and Exercise Pulmonary Testing Parameters (HRCT Emphysema Scoring과 운동부하 폐기능검사 지표들 간의 상관관계)

  • Choi, Eun-Kyoung;Choi, Young-Hee;Kim, Doh-Hyung;Kim, Yong-Ho;Yoon, Se-Young;Park, Jae-Seuk;Kim, Keun-Youl;Lee, Kye-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.50 no.4
    • /
    • pp.415-425
    • /
    • 2001
  • Background : The correlation between the high resolution computed tomography(HRCT) emphysema score and the physiologic parameters including resting and exercise pulmonary function test was investigated in 14 patients($60.6{\pm}10.3$ years) with pulmonary emphysema. Methods : The patients underwent a HRCT, a resting pulmonary function test, and incremental exercise testing(cycle ergometer, 10 W/min). Computed tomography scans were obtained on a GE highlight at 10 mm intervals using 10 mm collimation, from the apex to the base after a full inspiration. The emphysema scores were determined by a CT program 'Density mask' outlining the areas with attenuation values less than -900 HU, indicating the emphysema areas, and providing an overall percentage of lung involvement by emphysema. Results : Among the resting PFT parameters, only the diffusing capacity(r=-0.75) and $PaO_2$ (r=-0.66) correlated with the emphysema score(p<0.05). Among the exercise test parameters, the emphysema score correlated significantly with the maximum power(r=-0.74), maximum oxygen consumption(r=-0.68), anaerobic threshold(V-slope method: r=-0.69), maximal $O_2$-pulse(r=-0.73), and the physiologic dead space ratio at the maximum workload(r=-0.80)(p<0.01). Conclusion: We could find that exercise testing parameters showed a much better correlation with the HRCT emphysema score, which is known to have a good correlation with the pathologic severity than the resting PIT parameters. Therefore it is suggested that exercise testing is superior to resting PIT for estimating in the estimation of the physiologic disturbance in emphysema patients.

  • PDF

Physical Properties of Surface Sediments of the KR(Korea Reserved) 1, 2, and 5 Areas, Northeastern Equatorial Pacific (북동태평양 대한민국 광구 KR1, 2, 5 지역 표층 퇴적물의 물리적 특성 비교)

  • Lee, Hyun-Bok;Chi, Sang-Bum;Park, Cheong-Kee;Kim, Ki-Hyune;Ju, Se-Jong;Oh, Jae-Kyung
    • The Sea:JOURNAL OF THE KOREAN SOCIETY OF OCEANOGRAPHY
    • /
    • v.13 no.3
    • /
    • pp.168-177
    • /
    • 2008
  • Trafficablility of a miner and potential environmental impacts due to mining activities should be considered in the selection of a commercial manganese nodule mining site. These two factors can be evaluated comparatively with physical properties and shear strength of sea-bed sediments. For the qualitative comparison of potential minig sites in terms of these two factors, physical properties such as water contents, void ratios, porosities, and grain densities, and shear strengths of surface sediments were determined for the three potential manganese nodule mining sites(KR1, KR2, and KR5) in the Korean manganese nodule contract area, northeast Pacific. For the study, sediment samples were collected from 107 stations from 2004 to 2006. The physical properties of surface sediments showed more significant differences between northern(KR1, KR2) and southern(KR5) blocks than between northern blocks(KR1 vs. KR2). Water content, void ratio, and porosity of sediments from KR5 were relatively higher than those from KR1 and KR2. Grain density of sediments from KR5 was relatively lower than those from KR1 and KR2. Shear strengths of the top 10cm sediments were higher in KR1 and KR2, whereas those of the deeper part were highest in KR5 block. Generally, sediments of high water contents are less suspendible than those of the low water contents by benthic disturbances, thus less disturbance is expected in the sediments of high water content by mining activities. In terms of trafficability, the shear strength of sediment below 10 cm deep is more important than shallower part because miner will disturb at least top 10 cm interval of the surface sediments. Base on these results, we conclude that KR5 area will be the best site for commercial mining among three investigated sites in this study.

A Basic Study on the Establishment of Preservation and Management for Natural Monument(No.374) Pyeongdae-ri Torreya nucifera forest of Jeju (천연기념물 제374호 제주 평대리 비자나무 숲의 보존·관리방향 설정을 위한 기초연구)

  • Lee, Won-Ho;Kim, Dong-Hyun;Kim, Jae-Ung;Oh, Hae-Sung;Choi, Byung-Ki;Lee, Jong-Sung
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.32 no.1
    • /
    • pp.93-106
    • /
    • 2014
  • In this study, Analyze environment of location, investigation into vegetation resources, survey management status and establish to classify the management area for Natural monument No.374 Pyengdae-ri Torreya nucifera forest. The results were as follows: First, Torreya nucifera forest is concerned about influence of development caused by utilization of land changes to agricultural region. Thus, establish to preservation management plan for preservation of prototypical and should be excluded development activity to cause the change of terrain that Gotjawal in the Torreya nucifera forest is factor of base for generating species diversity. Secondly, Torreya nucifera forest summarized as 402 taxa composed 91 familly 263 genus, 353 species, 41 varieties and 8 forms. The distribution of plants for the first grade & second grade appear of endangered plant to Ministry of Environment specify. But, critically endangered in forest by changes in habitat, diseases and illegal overcatching. Therefore, when establishing forest management plan should be considered for put priority on protection. Thirdly, Torreya nucifera representing the upper layer of the vegetation structure. But, old tree oriented management and conservation strategy result in poor age structure. Furthermore, desiccation of forest on artificial management and decline in Torreya nucifera habitat on ecological succession can indicate a problem in forest. Therefore, establish plan such as regulation of population density and sapling tree proliferation for sustainable characteristics of the Torreya nucifera forest. Fourth, Appear to damaged of trails caused by use. Especially, Scoria way occurs a lot of damaged and higher than the share ratio of each section. Therefore, share ratio reduction Plan should be considered through the additional development of tourism routes rather than the replacement of Scoria. Fifth, Representing high preference of the Torreya nucifera forest tourist factor confirmed the plant elements. It is sensitive to usage pressure. And requires continuous monitoring by characteristic of Non-permanent. In addition, need an additional plan such as additional development of tourism elements and active utilizing an element of high preference. Sixth, Strength of protected should be differently accordance with importance. First grade area have to maintenance of plant population and natural habitats. Set the direction of the management. Second grade areas focus on annual regeneration of the forest. Third grade area should be utilized demonstration forest or set to the area for proliferate sapling. Fourth grade areas require the introduced of partial rest system that disturbance are often found in proper vegetation. Fifth grade area appropriate to the service area for promoting tourism by utilizing natural resources in Torreya nucifera forest. Furthermore, installation of a buffer zone in relatively low ratings area and periodic monitoring to the improvement of edge effect that adjacent areas of different class.

Diagnosis of Obstructive Sleep Apnea Syndrome Using Overnight Oximetry Measurement (혈중산소포화도검사를 이용한 폐쇄성 수면무호흡증의 흡증의 진단)

  • Youn, Tak;Park, Doo-Heum;Choi, Kwang-Ho;Kim, Yong-Sik;Woo, Jong-Inn;Kwon, Jun-Soo;Ha, Kyoo-Seob;Jeong, Do-Un
    • Sleep Medicine and Psychophysiology
    • /
    • v.9 no.1
    • /
    • pp.34-40
    • /
    • 2002
  • Objectives: The gold standard for diagnosing obstructive sleep apnea syndrome (OSAS) is nocturnal polysomnography (NPSG). This is rather expensive and somewhat inconvenient, however, and consequently simpler and cheaper alternatives to NPSG have been proposed. Oximetry is appealing because of its widespread availability and ease of application. In this study, we have evaluated whether oximetry alone can be used to diagnose or screen OSAS. The diagnostic performance of an analysis algorithm using arterial oxygen saturation ($SaO_2$) base on 'dip index', mean of $SaO_2$, and CT90 (the percentage of time spent at $SaO_2$<90%) was compared with that of NPSG. Methods: Fifty-six patients referred for NPSG to the Division of Sleep Studies at Seoul National University Hospital, were randomly selected. For each patient, NPSG with oximetry was carried out. We obtained three variables from the oximetry data such as the dip index most linearly correlated with respiratory disturbance index (RDI) from NPSG, mean $SaO_2$, and CT90 with diagnosis from NPSG. In each case, sensitivity, specificity and positive and negative predictive values of oximetry data were calculated. Results: Thirty-nine patients out of fifty-six patients were diagnosed as OSAS with NPSG. Mean RDI was 17.5, mean $SaO_2$ was 94.9%, and mean CT90 was 5.1%. The dip index [4%-4sec] was most linearly correlated with RDI (r=0.861). With dip index [4%-4sec]${\geq}2$ as diagnostic criteria, we obtained sensitivity of 0.95, specificity of 0.71, positive predictive value of 0.88, and negative predictive value of 0.86. Using mean $SaO_2{\leq}97%$, we obtained sensitivity of 0.95, specificity of 0.41, positive predictive value of 0.79, and negative predictive value of 0.78. Using $CT90{\geq}5%$, we obtained sensitivity of 0.28, specificity of 1.00, positive predictive value of 1.00, and negative predictive value of 0.38. Conclusions: The dip index [4%-4sec] and mean $SaO_2{\leq}97%$ obtained from nocturnal oximetry data are helpful in diagnosis of OSAS. CT90${\leq}$5% can be also used in excluding OSAS.

  • PDF