• 제목/요약/키워드: Base Plate

검색결과 612건 처리시간 0.241초

Evaluation of Fracture Toughness on High Frequency Electric Resistance Welded API 5LB Steel Pipe (API 5LB강관의 고주파전기저항용접부에 관한 파괴인성 평가)

  • 오세욱;윤한기;안계원
    • Journal of Ocean Engineering and Technology
    • /
    • 제1권1호
    • /
    • pp.127-137
    • /
    • 1987
  • The evaluation of the elastic-plastic fracture toughness $J_{1C}$ was performed on the center of weld metal(CWM), the heat affected zone (HAZ) and the base metal (BM) of API 5LB steel pipes welded by the high frequency electric resistance welding. The $J_{1C}$ was evaluated by the JSME R-Curve and JSME SZW methods using the smooth and side-grooved specimens. The results are as follows; (1) The $J_{1C}$ values by the SZW method are overestimated as compared with those by the R-curve method, because the micro-crack is formed as SZW increase with the deformation at SZ after initiation of the ductile crack. (2) The everage of $J_{1C}$ values by the the R-curve and the SZW methods in side-grooved specimens tended to decrease in comparison with smooth specimens 9.42% at CWM, 4.2% at HAZ, 23.2% at BM, respectively. (3) The boundary of the fatigue pre-crack, stretched zone, and dimple regions appeared more clearly in side-grooved specimens, for the slight change of SZW in the direction of the plate thickness, as compared with smooth specimens.

  • PDF

Study on flow behavior of polymer solutions in microchannels (미세구조 내에서의 사출성형 흐름에 관한 연구)

  • Kim Dong-Hak;Xu Guojun;Koelling Kurt W.;Lee L.James
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제7권3호
    • /
    • pp.471-475
    • /
    • 2006
  • Filling the microchannels is very important in designing micro-injection molding, microdevices, etc. In this paper, flow dynamics was studied in injection molding with microchannels. A transparent PMMA mold was designed and the flow dynamics was observed. The experiment was performed using poly (ethylene oxide) (PEO) and polyacrylamide (PA) aqueous solutions. The transignt dynamic flow and flow competition between the base plate and the microchannels were observed. The flow observation was used to explain previous filling length results in microchannels during micro-injection molding.

  • PDF

The Evaluation of Water Vapor Transport and Waterproofness Properties of the Waterproof and Breathable Fabrics (국내 시판 의류용 투습방수소재의 투습방수 성능평가)

  • Shim, Huen Sup
    • The Korean Journal of Community Living Science
    • /
    • 제27권2호
    • /
    • pp.295-304
    • /
    • 2016
  • This study was conducted to evaluate and compare the waterproofness and water vapor transport properties of 30 waterproof and breathable textiles in the market. MVTR upright cup test with water, MVTR inverted cup test with potassium acetate, and sweating hot plate test method were used for measuring the breathability of fabric samples. The waterproofness of all fabric samples and evaporative resistance of garment ensembles made with 5 selected waterproof and breathable textiles out of 30 samples were tested. The results of this study were as follows. The base fabrics of the most samples were basic weave structure with either polyester or nylon fiber. The waterproofness was over $5000mmH_2O$ for all the samples except densely woven fabrics. The evaporative resistance of garments that were made out of 5 fabric samples with a range of low to high breathability ranged $39.9{\sim}56.7m^2{\cdot}P{\cdot}W^{-1}$. The data of the water vapor transport properties of fabric samples varied with different test methods. Overall the bicomponent film fabrics showed better breathability and less standard deviation regardless of test methods. It is expected the breathability data without the information of test conditions used for marketing would confuse the consumers and the apparel manufacturers.

Temperature and Mechanical Properties of Welded Joints Under Friction Stir Welding Conditions of Mg Alloy (AZ61) (Mg Alloy(AZ61) 마찰교반용접 조건에 따른 용접부의 온도와 기계적 특성변화)

  • Lee, Woo Geun;Kim, Jung Seok;Sun, Seung-Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • 제26권4호
    • /
    • pp.378-386
    • /
    • 2017
  • Friction stir welding was performed using six welding conditions to evaluate the mechanical properties and microstructure of the welded zone based on its temperature change in the extruded plate of magnesium alloy AZ61. The welded zone temperature was measured using a thermocouple, and the maximum temperature ranges for the advancing and retreating sides were approximately $210-315^{\circ}C$ and $254-339^{\circ}C$, respectively. Depending on the welding conditions, a temperature difference of more than $100^{\circ}C$ was observed. In addition, the maximum yield strength and maximum tensile strength of the welded component was 84.4% and 96.9%, respectively, of those of the base material. For the temperatures exceeding $300^{\circ}C$, oxidation defects occurred in the weld zone, which decreased the mechanical strength of the weld zone. The microstructure and texture confirmed that fracture occurred because of the grain size deviation of the welding tool and the severe anisotropy of the texture of the welded joints.

A Study on Piping Support Design Process in Plant Piping System (플랜트 배관계에서 배관지지대 설계 기법에 관한 연구)

  • Chung, Chulsup
    • Journal of the Korean Institute of Gas
    • /
    • 제18권6호
    • /
    • pp.14-20
    • /
    • 2014
  • In this study, the stress analysis for the piping support design is performed as per the rules of the ASME Code, Section III, subsection NF-Component Support which provides a simplified method of design analysis for piping support. This method makes use of simple equations and conservative allowable stress limits for design and service loadings. For the base plate, code equation is satisfied within the allowable limits. Both anchor bolts and pipe strap are governed by the their interaction equations. The stresses resulting from various loadings and their combinations are within the allowable limits specified in the above mentioned ASME Code. Thus, it was proved that the structural integrity of the pump assembly was satisfactory.

A Study on the Structural Standard of the Tube and Coupler Scaffold (단관비계의 구조규격에 관한 연구)

  • 이영섭
    • Journal of the Korean Society of Safety
    • /
    • 제5권2호
    • /
    • pp.66-75
    • /
    • 1990
  • This study is conducted to establish the structural standard of tube and coupler scaffold which is suitable for our present stuation through the comparison analysis for domestic and foreign standards as well as measurement of field survey. The results of this study are as follows : 1) The load is classified by three categories, light-duty(equal and lower than 150kg/m$^2$), medium-duty(150-250 kg/m$^2$), heavy-duty(250-350kg/m$^2$), and the equivalent horizontal length of side posts is each, 1.5-1.8m, 1.2-1.5m, equal and lower than 1.2m, and the equivalent horizontal length between front and rear posts is each 1.2-1.5m, 0.9-1.2m, equal and lower thatn 0.9m, in accordance with the load classification. 2) The height between upper and lower runner is equal and lower than 1.5m, and the brace across the width of scaffold should be installed within 15m in horizontal direction at 45 degree angle. 3) The entire scaffold should be securely tied to the wall of permanent structure with uslng anchor and bolt at intervals not to exceed 6m in case of non-connection and 4.5m in case of connection in both horizontal and vertical direction. 4) The post should be installed on the sound foundation tied to lumber footing with using base plate, and standard platform plank should be produced in the factory and widely used in the construction field.

  • PDF

Features of the flow over a finite length square prism on a wall at various incidence angles

  • Sohankar, A.;Esfeh, M. Kazemi;Pourjafari, H.;Alam, Md. Mahbub;Wang, Longjun
    • Wind and Structures
    • /
    • 제26권5호
    • /
    • pp.317-329
    • /
    • 2018
  • Wake characteristics of the flow over a finite square prism at different incidence angles were experimentally investigated using an open-loop wind tunnel. A finite square prism with a width D = 15 mm and a height H = 7D was vertically mounted on a horizontal flat plate. The Reynolds number was varied from $6.5{\times}10^3$ to $28.5{\times}10^3$ and the incidence angle ${\alpha}$ was changed from $0^{\circ}$ to $45^{\circ}$. The ratio of boundary layer thickness to the prism height was about ${\delta}/H=7%$. The time-averaged velocity, turbulence intensity and the vortex shedding frequency were obtained through a single-component hotwire probe. Power spectrum of the streamwise velocity fluctuations revealed that the tip and base vortices shed at the same frequency as that ofspanwise vortices. Furthermore, the results showed that the critical incidence angle corresponding to the maximum Strouhal number and minimum wake width occurs at ${\alpha}_{cr}=15^{\circ}$ which is equal to that reported for an infinite prism. There is a reduction in the size of the wake region along the height of the prism when moving away from the ground plane towards the free end.

Satellite FEM Validation test for High Frequency Jitter Analysis

  • Oh, Shi-Hwan;Yong, Ki-Lyuk
    • Bulletin of the Korean Space Science Society
    • /
    • 한국우주과학회 2008년도 한국우주과학회보 제17권2호
    • /
    • pp.28.4-29
    • /
    • 2008
  • The aim of the test is to provide an experimental basis to validate the prediction of the FEM for high frequency jitter analysis due to reaction wheel. The principle is to measure structural transfer functions between the input disturbances at RWA base plate and the accelerations near the end tips of payload, in a configuration close to the operational model. The spacecraft shall have to be suspended, in order to be representative of on-orbit boundary conditions. The results of the test shall be compared to the output of the FEM analysis, and if needed, local upgrades of the FEM and/or margin policy shall be defined in order to guarantee a good test/FEM consistency. Test results were compared with the transfer functions of the FEM, which is globally tuned based on the results of vibration test and consequently have lower damping coefficients values than 1% in the frequency range of 60~200Hz. The damping coefficients estimated from the figures of FRF test results are different from the theoretical FEM, but the magnitude trend of FRF of the test results is somewhat similar with the analytical, it is expected that the overall jitter effect of final estimation is nearly same with the preliminary analysis result in which the damping coefficients were assumed to be 1% for all modes in FEM.

  • PDF

Soil -structure interaction analysis of a building frame supported on piled raft

  • Chore, H.S.;Siddiqui, M.J.
    • Coupled systems mechanics
    • /
    • 제5권1호
    • /
    • pp.41-58
    • /
    • 2016
  • The study deals with physical modeling of a typical building frame resting on pile raft foundation and embedded in cohesive soil mass using finite element based software ETABS. Both- the elements of superstructure and substructure (i.e., foundation) including soil is assumed to remain in elastic state at all the time. The raft is modelled as a thin plate and the pile and soils are treated as interactive springs. Both- the resistance of the piles as well as that of raft base - are incorporated into the model. Interactions between raft-soil-pile are computed. The proposed method makes it possible to solve the problems of uniformly and large non-uniformly arranged piled rafts in a time saving way using finite element based software ETABS. The effect of the various parameters of the pile raft foundation such as thickness of raft and pile diameter is evaluated on the response of superstructure. The response included the displacement at the top of the frame and bending moment in columns. The soil-structure interaction effect is found to increase displacement and increase the absolute maximum positive and negative moments. The effect of the soil- structure interaction is observed to be significant for the type of foundation and soil considered in the present study.

Effects of Welding Conditions and Material Arrangement on Tensile Properties of Friction Stir Lap Welded of Dissimilar Al Alloy, A5J32/A5052 (A5J32/A5052 이종 알루미늄 합금 겹치기 마찰교반접합부의 인장성질에 미치는 재료배열 및 접합조건의 영향)

  • Yoon, Tae-Jin;Kang, Myung-Chang;Kang, Chung-Yun
    • Journal of Powder Materials
    • /
    • 제20권4호
    • /
    • pp.302-307
    • /
    • 2013
  • A5J32-T4 and A5052-H32 dissimilar aluminum alloy plates with thickness of 1.6 and 1.5 mm were welded by friction stir lap welding (FSLW). The FSLW were studied using different probe length tool and various welding conditions which is rotation speed of 1000, 1500 rpm and welding speed of 100 to 600 mm/min and material arrangement, respectively. The effects of plunge depth of tool and welding conditions on tensile properties and weld nugget formation. The results showed that three type nugget shapes such as hooking, void, sound have been observed with revolutionary pitch. This plunge depth and material arrangement were found to effect on the void and hooking formation, which in turn significantly influenced the mechanical properties. The maximum joint efficiency of the FSLWed plates was about 90% compared to base metal, A5052-H32 when the A5052-H32 was positioned upper plate and plunge depth was positioned at near interface between upper and lower plates.