• 제목/요약/키워드: Barium sulfate

검색결과 82건 처리시간 0.024초

3CaO.$SiO_2$의 구조전이에 미치는 $BaSO_4$의 영향 (The Effect of Barium Sulfate on the Structural Transformations in Tricalcium Silicate)

  • 서일영;최상흘
    • 한국세라믹학회지
    • /
    • 제11권2호
    • /
    • pp.17-21
    • /
    • 1974
  • Miscibility of barium sulfate in tricalcium silicate was investigated by firing 3CaCO3·SiO2 mixture containing barium sulfate at 1530℃. Added amount of barium sulfate to the mixture was zero to 5 mole % with intervals of 1 mole %. Lattice parametres were also calculated. Results were as follow; 1) Dissolution of barium sulfate in tricalcium silicate does not alter the symmetry in room temperature, but influences it's polymorphic transition forms, temperatures and thermal effects; modification triclinic Ⅱ is stabilized in room temperature. 2) Barium sulfate dissolves about up to 2 mole % in tricalcium silicate and more than this amount, tricalcium silicate formation is inhibited. 3) Unit cell volume of tricalcium silicate is slightly decreased with dissolution of barium sulfate, mainly because of contraction in c axis.

  • PDF

Barium 조영제의 농도 차이가 PET 검사에 미치는 영향 (Influence on PET Exam Caused by Density Differences of Barium-sulfate Contrast Media)

  • 최우준;신상기;남기표;박순기
    • 핵의학기술
    • /
    • 제12권1호
    • /
    • pp.27-32
    • /
    • 2008
  • Purpose: The evaluation of SUV (Standardized Uptake Values) for quantitative analysis in PET exam is the most significant. In PET exam, we make attenuation correction images by using $^{68}Ge$, $^{137}Cs$ or CT data. At this time, a distorted attenuation map affects quantitative analysis. After the exam using barium-sulfate and high density of barium contrast make attenuation map distorted. And then it brings bed influences on SUV. The aim of this study is to verify the relationship between high density barium-sulfate and SUV in PET exam. Materials and Methods By using $^{18}F$-FDG, we made barium-sulfate powder, density of 0, 1.5, 3, 5, 10 and 15% respectively and acquired PET and PET/CT images per each density. And we examined SUV variations from PET and PET/CT images according to differences of barium's density. Moreover, we finally calculated SUV causing variations in HU (Hounsfield Units) values to justify whether the differences of barium density bring any changes in PET/CT exam. Results: From PET images acquired from transmission scan with $^{68}Ge$, we got SUV figures from 6.46 to 6.8 in barium density between 0 to 15 percent. On the other hand, In PET images acquired from Tx scan that using CT, SUV was 6.77 to 23.73, derived from the same barium density. And CT HU values range from 29 to 2004. Conclusion: PET images from Tx data using $^{68}Ge$ weren't affected by barium density and had no differences in SUV. But in the PET/CT images using CT Tx data, there's considerable variations in HU and SUV values according to a difference of barium density in HU values. To perform a precise examination, barium sulfate should be removed from a human body before performing a PET exam.

  • PDF

황산바륨의 최적합성조건 (Optimal Synthesis Conditions of Barium Sulfate)

  • 신화우;최광식
    • 약학회지
    • /
    • 제46권5호
    • /
    • pp.364-368
    • /
    • 2002
  • Optimal synthetic conditions of barium sulfate were investigated from the viewpoint of yield and bulkiness according to a randomized complete block design proposed by Box and Wilson. Barium chloride and Sodium sulfate were utilized as reactants in order to prepare barium sulfate in this study. The optimum Synthesis conditions of barium sulfate obtained from this study are as follows; Reactant temperature; 60~75$^{\circ}C$ (viewpoint of yield) and 60~71$^{\circ}C$ (viewpoint of bulkiness). Concentration of two reactants; 12.7~14.4% (viewpoint of yield) and 5~10.5% (viewpoint of bulkiness). Mole ratio of two reactants, [BaCl$_2$]/[Na$_2$SO$_4$]; 1.62~1.96 (viewpoint of yield) and 2.0 (viewpoint of bulkiness). Reacting time; 13~15 minutes (viewpoint of yield) and 12~14 minutes (viewpoint of bulkiness). Drying temperature of product; 86~10$0^{\circ}C$ (viewpoint of yield) and 6$0^{\circ}C$ (viewpoint of bulkiness).

3D 프린터를 이용한 바륨혼합형 차폐체에 대한 연구 (A Study on Barium Mixed Radiation Shield using 3D Printer)

  • 강헌효;김동현
    • 한국방사선학회논문지
    • /
    • 제14권5호
    • /
    • pp.627-634
    • /
    • 2020
  • 본 연구는 기존의 납을 대신해 친환경 물질인 황산바륨과 3D 프린터 소재인 PLA 필라멘트를 혼합하여 형태학적 구현을 위한 차폐체를 개발하고자 하였다. 환경 물질인 황산바륨 분말 가루와 3D프린터 소재인 PLA 필라멘트를 사용하였으며, 황산바륨 분말 가루와 PLA를 혼합하기 위하여 압출기로 융합 후 3D 프린터로 차폐체를 제작하였다. 황산바륨 파우더 분말 가루와 PLA 필라멘트 혼합비율을 확인하기 위해 혼합입도를 분석하였으며, 혼합된 차폐체의 차폐능을 확인하기 위해 황산바륨 함유량에 따른 두께별 흡수선량을 구하여 선량을 평가한 후 차폐능을 분석했다.황산바륨 분말 입자와 PLA 필라멘트 혼합 입도 평가 시 외관상과 주사전자현미경 관찰사진에서 함유량이 30%일 때 가장 적정비율로 혼합된 것을 확인하였다. 황산바륨 함유량에 따른 두께별 흡수선량 결과에서 함유량이 0%일 때와 각 % 별 함유량을 비교했을 때 두께 0.5 cm에서 흡수선량의 차이가 가장 크게 나타났으며, 바륨함유량이 30%일 때 두께 3 cm에서 가장 낮은 선량값을 나타냈다. 또한 바륨함유량이 30%를 기점으로 함유량이 증가할수록 흡수 선량값은 다시 높아지는 결과가 나타났다. 기존의 납 대신 친환경 물질인 황산바륨을 필라멘트 소재인 PLA와 혼합하여 형태학적인 차폐체를 만들 수 있었다. 혼합물에 대한 바륨의 혼합비율은 30%가 가장 적절하며, 본 연구를 토대로 진단 방사선 분야 내 3D 프린터를 이용한 형태학적 차폐체 구현을 위한 기초 자료로 사용될 것으로 기대한다.

실리콘 혼합 차폐체의 개발과 성능비교 (Development and Performance Comparison of Silicon Mixed Shielding Material)

  • 정회원;민정환
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권3호
    • /
    • pp.187-195
    • /
    • 2023
  • A shield was made by mixing materials such as bismuth(Bi) and barium(Ba) with silicon to evaluate its shielding ability. Bismuth was made into a shield by mixing a bismuth oxide(Bi2O3) colloidal solution and a silicon base and applied to a fibrous fabric, and barium was made by mixing lead oxide(PbO) and barium sulfate(BaSO4) with a silicon curing agent and solidifying it to make a shield. The test was conducted according to the lead equivalent test method for X-ray protective products of the Korean Industrial Standard. The experiment was conducted by increasing the shielding body one by one from the test condition of 60 kVp, 200 mA, 0.1sec and 100 kVp, 200 mA, 0.1 sec. At 60 kVp, 2 lead oxide-barium sulfate shields, 2 bismuth oxide 1.5 mm shields, and 5 bismuth oxide 0.3 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. At 100 kVp, 2 lead oxide-barium sulfate shields and 2 bismuth oxide 1.5 mm shields showed shielding ability equal to or higher than that of lead 0.5 mm. It was confirmed that when using 2 pieces of lead oxide-barium sulfate and 1.5 mm of bismuth oxide, respectively, it has shielding ability equivalent to that of lead. Bismuth oxide and lead oxide-barium sulfate are lightweight and have excellent shielding ability, thus they have excellent properties to be used as an apron for radiation protection or other shielding materials.

전침자극이 개의 위장관운동에 미치는 영향 (Effects of Electroacupuncture on Motility of the Castro-intestinal Tract of Dogs)

  • 성재기;남치주
    • 한국임상수의학회지
    • /
    • 제5권1호
    • /
    • pp.9-21
    • /
    • 1988
  • Gastro-intestinal mortility and transit time of barium sulfate after electroacupuncture were investigated in normal dogs and administration of xylatine in dogs. Electroacupuncture was performed with a current of 1.5 volt and 20 Hz at the acupoints of Tsu San Li(right(+) left(-) in dogs for 30 minutes. The results were as follows: 1. After electroacupuncture stimnlation in normal dogs, rates of stomach contractions was not changed, but amplitudes of stomach motility was markadly increased. The electroacupuncture stimulation tasted about 60 minutes after the end of electroacupuncture. 2. The stomach contractions was markedly increased, while the amplitudes of stomach motility was sligltly decreased by the administration of xylazine in dogs. 3. The rates of stomach contractions and amplitudes of motility were markedly increased after administration of xylazine in the electroacupuncture stimulated dogs. 4. Gastric emptying time o barium sulfate after electroacupuncture stimulation in dogs was highly significantly decreased compared with that of normal dogs(p < 0.01). 5. Small bowel transit time of barium sulfate after electroacupuncture stimulation in dogs was highly significantly decreased compared with that of normal dogs (p < 0.01). 6. Gastroduodenal transit time of barium sulfate after administration of xylazine following electroacupuncture stimulation dogs was blighty significantly decreased compared to that of dogs dosed with xylazine (p< 0.01). 7. Small bowel transit time of barium sulfate after administration of xylazine following electroacupuncture stimulation dogs markedly decreased compared to that of dogs dosed with xylazine (p < 0.05).

  • PDF

황산바륨의 공침현상을 이용한 중금속 이온의 제거 (Removal of heavy metal by coprecipitation with barium sulfate)

  • 임헌성;임석근
    • 분석과학
    • /
    • 제19권4호
    • /
    • pp.280-284
    • /
    • 2006
  • The objective of this study is to investigate the removal of heavy metal by using the coprecipitation of barium sulfate. Several parameters governing the efficiency of the coprecipitation method were evaluated by the pH of sample solution, amount of coprecipitant, and addition of sulfide for the removal of As(V), Cd(II), Cr(III), Cr(VI), Cu(II), Hg(II) and Pb(II) metal ions ($10{\mu}g/ml$ each). The coprecipitation was about 80% - 95% only for lead at low pH but under 10% for other ions. The amount of removal was about 95% - 100% for Cd, Hg, Pb, Cu in the all pH range by the addition of sulfide with barium sulfate but As(V) and Cr(III, VI) ions were not affected by the same conditions.

Portland Cement Clinker 생성반응에 미치는 $CaSO_4$$BaSO_4$의 영향 (Effect of $CaSO_4$ and $BaSO_4$ on the Formation of Portland Cement Clinker)

  • 서일영;최상흘
    • 한국세라믹학회지
    • /
    • 제11권1호
    • /
    • pp.29-35
    • /
    • 1974
  • Effect of calcium sulfate and barium sulfate on the formation of portland cement clinker was studied by means of chemical analysis. DTA and X-ray diffraction analysis. In the presence of liquid phase, effect of the additives on the formation of tricalcium silicate was examined according to the reaction, 2CaO.$SiO_3$+CaO$\longrightarrow$3CaO.$SiO_3$, which is the principal reaction in portland cement clinkerization, and optimum conditions in firing clinker concerning amount of additive, firing time and temperature were determined, and its kinetics was referred to. The experimental results are summerized as follow: (1) Appropriate burning temperature range of cement clinker is more limited as the content of calcium sulfate in clinker is increased. Amount of calcium sulfate, firing time and temperature in proper condition of clinkerization is related to each others. Being added suitable quantity of calcium sulfate, firing temperature of clinker can be lowered about $100^{\circ}C$. (2) When 3-5 mole% of calcium sulfate is added, firing time of 15-30 minutes at about $1380^{\circ}C$ is reasonable, and if the content is over7 mole %, firing for 1 hr. or more at $1350^{\circ}C$ is anticipated to be optimum condition. (3) In the reaction of tricalcium silicate formation, the role of barium sulfate as a mineralizer is similar to that of calcium sulfate, but the optimum firing temperature of cement clinker containing barium sulfate tends to be 20-$30^{\circ}C$ higher than that of clinker containing calcium sulfate. (4) When barium sulfate is used as mineralizer, 2-3 mole % of it to tricalcium silicate is recommended and if it is added more than this amount, free CaO is increased rapidly in clinker and alite formation is inhibited.

  • PDF

Massive barium sulfate aspiration during upper gastrointestinal contrast material study in an elderly patient with dysphagia

  • Yun, Hae Ryong;Kim, Chang-gon;Park, Jihye;Park, Yong eun;lee, Yong-il;Yoo, Byung-Woo;Chung, Kyung Soo;Kim, Young Sam;Song, Joo Han
    • Journal of Yeungnam Medical Science
    • /
    • 제33권2호
    • /
    • pp.162-165
    • /
    • 2016
  • Barium sulfate is an inert material used as a radiographic contrast medium during upper gastrointestinal contrast studies for evaluation of patients with dysphagia. Oral barium aspiration is an uncommon but well-reported complication of this procedure. While barium aspiration of small amounts may not cause any symptoms, massive barium aspiration can be life-threatening, particularly in elderly patients with multiple comorbidities. In this case report, we describe an elderly patient with multiple comorbidities who presented with thyrotoxicosis and dysphagia, and then died after massive barium aspiration. Despite administration of intensive medical care with ventilator support and therapeutic bronchoalveolar lavage to remove the aspirated barium, the patient died of multiple organ failure 9 days after barium aspiration. Clinicians should pay attention to elderly patients with predisposing factors for aspiration in whom upper gastrointestinal barium contrast studies are indicated, and should consider other diagnostic tools for evaluation of dysphagia in this population.

바륨설페이트/티타늄디옥사이드/디메치콘의 복합화 및 메이크업에서의 응용 (A Study on the Surface-Modification of Barium Sulfate/TiO$_2$/Dimethicone Composite Powder and its Application in Color Cosmetics)

  • Kyung-Ho, Choi;Seung-Yong, Ko;Hak-Hee, Kang;Ok-Sub, Lee
    • 대한화장품학회지
    • /
    • 제30권2호
    • /
    • pp.197-200
    • /
    • 2004
  • 감촉 및 광학적 요소는 파우다 파운데이션에 있어서 매우 중요한 요소이다. 이러한 감촉과 광학적인 요소를 동시에 만족하는 분체에 관심을 가지고 다양한 소재 및 제조방법을 연구 중에 바륨설페이트를 기본 입자로 하는 복합화 된 분체를 개발하게 되었다. 바륨설페이트는 입자의 모양이 매우 넓고 표면의 굴곡이 없는 판상으로 감촉면에서 부드러운 사용성과 균일한 부착 특성을 나타내며 굴절율도 피부보다 약간 높은 수준으로 인위적이지 않고 자연스러운 광학적 특성을 나타내고 있다. 그러나 파운데이션에서 요구되는 광학적 특성인 자외선 차단능력이나 커버력, 블루밍 효과에 있어서는 기대수준에 못 미치는 것을 알 수 있었다. 이러한 특징은 파우다 파운데이션에서 사용되는 대부분의 분체에 있어서 공통적으로 나타나는 특성으로 감촉적인 측면(소프트, 밀착력 등)과 광학적 측면(커버력, 자외선 차단력 등)을 동시에 만족하는 분체가 극히 드문 것을 알 수 있다. 본 연구에서는 이러한 점을 극복하고자 감촉적인 측면에서 우수한 바륨설페이트를 모입자로 하고 자외선 차단능력과 블루밍에서 우수하나 자체의 응집력이 강하고 사용감이 거친 특징을 나타내고 있는 티타늄디옥사이드를 자입자로 하여 복합화하려 하였다. 이때 중요 요소로 복합화 되는 티타늄디옥사이드의 함량에 따라 복합안료의 감촉적인 측면과 분산력 등이 민감하게 달라지는 것을 알 수 있었다. 이에 패널을 이용하여 복합안료의 사용성에 영향을 미치지 않는 수준의 함량을 결정하여 복합화 처리했으며, 사용자가 피부에 도포시 발생되는 피지나 땀에 대한 변색과 사용감을 고려하여 피지나 땀에 강한 발수, 발유 능력을 나타내며 부드러운 감촉의 디메치콘으로 복합안료를 코팅 처리하여 복합분체를 만들게 되었다. 이렇게 만든 복합분체(barium sulfate/TiO$_2$/dimethicone)를 패널을 이용한 테스트와 기기를 이용한 테스트를 실시하여 효과를 검증하게 되었다.