• 제목/요약/키워드: Bare Tube

검색결과 68건 처리시간 0.022초

LiBr/$H_2O$계 흉수기의 흡수촉진에 관한 실험적 연구 (Experimental investigation of enhanced heat and mass transfer toy LiBr/$H_2O$ absorber)

  • 설원실;권오경;윤정인
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.581-588
    • /
    • 1998
  • An experimental study of the absorption process of water vapor into Lithium Bromide solution was performed. For the purpose of development of high performance absorption chiller-heater utilizing Lithium Bromide solution as working fluid, the absorber is the most effective to improve the performance of an absorber because it requires the largest heat transfer area in an absorption chiller-heater system. This paper introduces bare tube and floral tube for the absorber of absorption chiller-heaters. floral tube has higher heat and mass transfer performance than bare tube conventionally used in absorbers and the it is expected to perform high heat and mass transfer. This paper will provide important information on the selection of absorber tubes in commercial absorption chiller -heaters.

  • PDF

계면활성제를 이용한 수평관군 흡수기의 전열촉진 (Heat Transfer Enhancement with Surfactants in Horizontal Bundle Tubes on Absorber)

  • 설원실;권오경;문춘근;윤정인
    • 대한기계학회논문집B
    • /
    • 제24권8호
    • /
    • pp.1097-1103
    • /
    • 2000
  • This research was concerned with the enhancement of heat transfer by surfactant added to the aqueous solution of LiBr. Different horizontal tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, floral tube and hydrophilic tube. The additive mass concentration was about 0.05${\sim}$5.5%. The heat transfer coefficient was measured as a function of solution flow rate for the range of 0.01${\sim}$0.034 kg/ms. The experimental results were compared with cases without surfactant. The enhancement of heat transfer by Marangoni convection effect generated by the addition of the surfactant is observed in each test tube. The increase of heat transfer coefficient by surfactant addition is about 35${\sim}$90% for bare tube, 40${\sim}$70% for the floral tube, 30${\sim}$50% for the hydrophilic tube and was higher for the cases with smaller a little solution flow rates.

A Study of the Defrosting Behavior according to Surface Characteristics of a Fin-Tube Heat Exchanger

  • Jhee, Sung;Lee, Kwan-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제8권2호
    • /
    • pp.101-107
    • /
    • 2000
  • In this study, the defrosting behavior according to the surface characteristics of a fin-tube heat exchanger is experimentally examined. It has been found that the draining rates of the hydrophilic and hydrophobic heat exchangers are evenly dispersed during do-frosting, compared with that of the bare one. This is due to the high density frost of the hydrophilic heat exchanger, and the surface characteristics of the hydrophobic heat ex-changer, The rest periods of the hydrophilic and hydrophobic heat exchangers are shorter, and their weight of residual water is also smaller than that of the bare heat exchanger. The hydrophobic heat exchanger is the most efficient in terms of the defrosting efficiency.

  • PDF

수직관 흡수기의 물질전달에 미치는 계면활성제의 영향 (Influence of Surfactant on Mass Transfer of Vertical Absorber)

  • 권오경;윤정인;윤재호
    • 대한기계학회논문집B
    • /
    • 제27권5호
    • /
    • pp.604-611
    • /
    • 2003
  • This study was concerned with the enhancement of mass transfer by surfactant added to the aqueous solution of LiBr. Different vertical inner tubes were tested with and without an additive of normal octyl alcohol. The test tubes were a bare tube, groove tube, corrugate tube and inserted spring tubes. The additive concentration of normal octyl alcohol as a surfactant is about 0.08mass%. The Sherwood number was measured as a function of film Reynolds number 20~200. The experimental results were compared with those which use no surfactant. The enhancement of mass transfer by Marangoni convection effect which was generated by addition of the surfactant is proved for each testing tube Especially, it is clarified that the tube with the spring has the highest enhancement effect. A correlation of the experimental mass transfer data for the bare, groove, corrugate and insert spring tubes results expressed as the form of Sh=cㆍ Re$_{f}$ $^{n}$ .

베어관을 이용한 30RT급 하이브리드 밀폐형 냉각탑의 성능특성에 관한 실험적 연구 (An Experimental Study on Performance Characteristic of 30RT Closed-Type Hybrid Cooling Tower using Bare Tube)

  • 전철호;이호생;문춘근;김재돌;윤정인
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.1096-1101
    • /
    • 2005
  • In this study, the experiment of thermal performance about closed-type hybrid cooling tower was conducted. A closed type cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The test section for this experiment has the process that the cooling water flows from top part of heat exchanger to bottom side in the inner side of tube, and spray water flows gravitational direction in the outer side of it. Air contacts of tube outer side are counterflow. The heat transfer pipe used in this experiment is a bare type tube having an outside diameter of 15.88mm. In this experiment, heat performances of the cooling tower are calculated such as overall heat transfer coefficient of between the process fluid and air, cooing capacity and pressure drop.

  • PDF

미소해칭 전열관의 표면거칠기에 따른 흡수열전달 특성 (Characteristics of Absorption Heat Transfer on Micro-Scale Hatched Tubes with Different Surface Roughness)

  • 조현철;김춘동;김익생;박찬우;강용태
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.641-647
    • /
    • 2002
  • Objectives of this paper are to investigate the effect of roughness of micro-hatching tubes on the absorption performance and to develop on experimental correlation of Nusselt as a function of the roughness. Three different micro-scale hatched tubes and a bare tube were tested in the present experiment. $H_{2}O/LiBr$ solution is used as working fluid. It was found that absorption performance of micro-scale hatched tubes were improved upto 2 times with an error band of ${\pm}25%$ compared with the bare tube. An experimental correlation of Nusselt was developed as a function of the roughness.

스프링삽입형 유하액막식 흡수기의 열 및 물질전달 특성 (Characteristics of Heat and Mass Transfer for a Falling Film Type Absorber with Insert Spring Tubes)

  • 윤정인;오후규;백목효부
    • 대한기계학회논문집
    • /
    • 제19권6호
    • /
    • pp.1501-1509
    • /
    • 1995
  • It is known that the heat and mass transfer characteristics in the absorber are most sensitive of the temperature boost of all the heat exchangers and the development of a more efficient absorber should be highly important. This paper describes absorption experiments made with different inside tube diameters, tube length and tube shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a Lithium Bromide-water solution flowing down an absorber of vertical inner tubes. As a result, insert spring tube compares bare tube and heat transfer improved by order of insert spring tube P2(pitch 20 mm) and P1(pitch 10 mm).

수직흡수기의 열 및 물질전달 촉진 (Enhancement of Heat and Mass Transfer for a Vertical Type Absorber)

  • 권오경
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제22권3호
    • /
    • pp.362-370
    • /
    • 1998
  • Absorption systems require a heat source for working but they have a great merit in that relatively low-temperature and low-quality types of thermal energy such as solar heat and exhaust heat can be effectively utilized as heat source. However details research related to absorbers which have a great effect on performances has been rarely done and thus there has been a strong hope for positive developments to improve their efficiencies. This paper describes absorption experiments made with different inside tube diameters and shapes. The purpose of this study is to acquire basic knowledge about heat and mass transfer in a falling film type absorber with vertical inner tubes. Heat and mass transfer were measured for water vapor absorption into a water/LiBr solution flowing down an absorber of vertical inner tubes. As a result absorption acceleration tube compares bare tube and heat transfer improved by order of insert spring tube corrugated tube grooved tube. And the acceleration that is good provided in inserting spring tube for both sides of heat and mass transfer.

  • PDF

콘크리트 충전 각형강관 주각부의 내력 및 변형에 관한 연구 (A Study on the Behaviors of Column-to-Footing Connections for Concrete Filled Tube(CFT) System)

  • 김철환;김성은
    • 한국강구조학회 논문집
    • /
    • 제22권3호
    • /
    • pp.253-260
    • /
    • 2010
  • 콘크리트충전 강관구조는 구조성능이 우수하고 내화성능 등이 우수하여 점진적으로 현장 적용이 확대되고 있다. 그러나 지금까지 이러한 구조형식에 있어서는 구조부재의 저항능력에 대해 연구가 활발하게 진행되어 왔으나, 기둥의 주각부에 대한 연구가 활발하지 못하여 아직까지 주각부에 대한 응력의 흐름이나 이력 특성에 대해 명확히 규명되어 있지 못하며, 따라서 주각부에 대한 구조설계 시에는 순수 철골구조에서 적용하는 설계방법을 원용하여 설계되고 있다. 본 연구에서는 충전강관 기둥의 주각부에 있어서의 구조적 거동을 규명하기 위하여 실험을 수행하였다. 실험의 주된 변수로는 강관의 주각부 형식과 매립깊이를 변수로 하였으며, 비교를 위하여 순수강관 기둥에 대한 주각부의 실험도 병행하였다. 실험결과 순수강관과 충전강관의 주각부에 있어 구조적 거동의 차이점은 크게 나타나지 않고 있으나, 주각부의 형식에 따른 거동의 차이는 크게 나타나고 있다.

멀티버너 보일러용 열교환기 모듈 특성 시험 - 모듈 순서에 따른 특성결과 - (Experimental Study on Thermal Characteristics of Heat Exchanger Modules for Multi Burner Boiler)

  • 강새별;김종진;안준
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3053-3058
    • /
    • 2008
  • We develop a heat exchanger modules for a multi-burner boiler. The heat exchanger module is kind of a heat recovery steam generator (HRSG). This heat recovery system has 4 heat exchanger modules. The 1st module consists of 27 bare tubes due to high temperature exhaust gas and the others consist of 27 finned tubes. The maximum steam pressure of each module is 1 MPa and tested steam pressure is 0.7 MPa. In order to test these heat exchanger modules, we make a 0.5t/h flue tube boiler (LNG, $40\;Nm^3/h$). We tested the heat exchanger module with changing the position of each heat exchanger module. We measured the inlet and outlet temperature of each heat exchanger module and calculated the heat exchange rate. The results show that if module C is placed at second stage (the 1st stage is always module O, bare tube module), there is no need to attach an additional heat exchanger module. In this case the exit temperature of module C is low enough to enter an economizer which is more effective in heat recovery than a heat exchanger module.

  • PDF