• Title/Summary/Keyword: Bang-Jae

Search Result 1,252, Processing Time 0.031 seconds

Effects of Shield Materials on the Growth and Yield Characteristics of Melon Grown inside a Plastic Greenhouse in Summer Season (고온기 멜론 시설재배 시 자재별 차광 효과)

  • Lee, Jae Han;Lee, Jung Sup;Kwon, Joon Kook;Yeo, Kyung Hwan;Bang, Ji Woong;Kim, Jin Hyun;Lee, Choung Keun;Park, Kyoung Sub;Myung, Dong Ju
    • Journal of Bio-Environment Control
    • /
    • v.30 no.4
    • /
    • pp.304-311
    • /
    • 2021
  • This Experiment was conducted to determine the effects of light shield materials when melon grown inside a plastic greenhouse in summer season. The average temperatures were 36.6℃, 34.5℃ and 34.0℃ respectively for the control(non-shield), coating agent, and the white net. The light transmittances were 69% and 75%, respectively inside the greenhouse treated with the coating agent and white net immediately after applicants, compared with that inside the control greenhouse. At the 40 and 80 days after treatment, the light transmittances for the coating agent were 92% and 98%, respectively, indicating it was slowly decomposed and removed, but there was no change in the transmittance for the white net. While the leaf number did not differ among the treatments, the plant height was higher in the white net and shading agent than in control. The weight of the leaves, fresh-weight and dry-weight were no different from that of shading, but it became heavier in the later stages. The marketable fruit yield was increased by 6% for white nets and 5% for the coating agent compared to control, there was no statistical significance. Therefore, coating agent is considered as an effective method to lower temperature during high temperature period, but it is preferable to use it in consideration of cultivation period, because the coating agent is gradually removed.

Synthesis and Characterization of Polymers with Azobenzene and Hexamethylene Groups in Main Chain (주사슬에 아조벤젠기와 헥사메틸렌기를 갖는 고분자의 합성 및 특성)

  • Gu, Su-Jin;Lee, Eung-Jae;Bang, Moon-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.86-92
    • /
    • 2019
  • Polymers with various compositions of azobenzene and hexamethylene groups in the main chain were synthesized by a Schotten-Baumann reaction and their properties were investigated. The chemical structures and physical properties of the synthesized polymers were investigated by Fourier transform infrared spectroscopy, proton nuclear magnetic resonance spectroscopy, differential scanning calorimetry, thermogravimetric analysis, polarized optical microscopy, and x-ray diffraction. The polymers showed an inherent viscosity of 1.28-1.36 dl/g and were relatively insoluble in most organic solvents. The melt transition temperature increased rapidly with increasing number of azobenzene groups in the polymer. When the azobenzene monomer content was more than 50 mol%, no melting transition occurred below the decomposition temperature. Among the polymers with a melt transition temperature, the MP-A3C7 and MP-A5C5 polymers were liquid crystalline materials and exhibited a nematic phase with weak liquid crystallinity over a wide liquid crystal temperature range. This difference in the properties of the synthesized polymers is likely due to the changes in intermolecular forces resulting from the linearity and polarity of the trans-form of azobenzene.

Changes of carbon-13 Isotope of Dissolved Inorganic Carbon Within Low-pH CO2-rich Water during CO2 Degassing (pH가 낮은 탄산수의 CO2 탈기에 따른 용존탄소동위원소 변화)

  • Chae, Gitak;Yu, Soonyoung;Kim, Chan Yeong;Park, Jinyoung;Bang, Haeun;Lee, Inhye;Koh, Dong-Chan;Shinn, Young Jae;Oh, Jinman
    • Journal of Soil and Groundwater Environment
    • /
    • v.24 no.3
    • /
    • pp.24-35
    • /
    • 2019
  • It is known that ${\delta}^{13}C_{DIC}$ (carbon-13 isotope of dissolved inorganic carbonate (DIC) ions) of water increases when dissolved $CO_2$ degases. However, ${\delta}^{13}C_{DIC}$ could decrease when the pH of water is lower than 5.5 at the early stage of degassing. Laboratory experiments were performed to observe the changes of ${\delta}^{13}C_{DIC}$ as $CO_2$ degassed from three different artificial $CO_2$-rich waters (ACWs) in which the initial pH was 4.9, 5.4, and 6.4, respectively. The pH, alkalinity and ${\delta}^{13}C_{DIC}$ were measured until 240 hours after degassing began and those data were compared with kinetic isotope fractionation calculations. Furthermore, same experiment was conducted with the natural $CO_2$-rich water (pH 4.9) from Daepyeong, Sejong City. As a result of experiments, we could observe the decrease of DIC and increase of pH as the degassing progressed. ACW with an initial pH of 6.4, ${\delta}^{13}C_{DIC}$ kept increasing but, in cases where the initial pH was lower than 5.5, ${\delta}^{13}C_{DIC}$ decreased until 6 hours. After 6 hours ${\delta}^{13}C_{DIC}$ increased within all cases because the $CO_2$ degassing caused pH increase and subsequently the ratio of $HCO_3{^-}$ in solution. In the early stage of $CO_2$ degassing, the laboratory measurements were well matched with the calculations, but after about 48 hours, the experiment results were deviated from the calculations, probably due to the equilibrium interaction with the atmosphere and precipitation of carbonates. The result of this study may be not applicable to all natural environments because the pressure and $CO_2$ concentration in headspace of reaction vessels was not maintained constant as well as the temperature. Nevertheless, this study provides fundamental knowledge on the ${\delta}^{13}C_{DIC}$ evolution during $CO_2$ degassing, and therefore it can be utilized in the studies about carbonated water with low pH and the monitoring of geologic carbon sequestration.

Prediction of itching diagnostic marker through RNA sequencing of contact hypersensitivity and skin scratching stimulation mice models

  • Kim, Young-Won;Zhou, Tong;Ko, Eun-A;Kim, Seongtae;Lee, Donghee;Seo, Yelim;Kwon, Nahee;Choi, Taeyeon;Lim, Heejung;Cho, Sungvin;Bae, Gwanhui;Hwang, Yuseong;Kim, Dojin;Park, Hyewon;Lee, Minjae;Jang, Eunkyung;Choi, Jeongyoon;Bae, Hyemi;Lim, Inja;Bang, Hyoweon;Ko, Jae-Hong
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.23 no.2
    • /
    • pp.151-159
    • /
    • 2019
  • Pruritus (itching) is classically defined as an unpleasant cutaneous sensation that leads to scratching behavior. Although the scientific criteria of classification for pruritic diseases are not clear, it can be divided as acute or chronic by duration of symptoms. In this study, we investigated whether skin injury caused by chemical (contact hypersensitivity, CHS) or physical (skin-scratching stimulation, SSS) stimuli causes initial pruritus and analyzed gene expression profiles systemically to determine how changes in skin gene expression in the affected area are related to itching. In both CHS and SSS, we ranked the Gene Ontology Biological Process terms that are generally associated with changes. The factors associated with upregulation were keratinization, inflammatory response and neutrophil chemotaxis. The Kyoto Encyclopedia of Genes and Genomes pathway shows the difference of immune system, cell growth and death, signaling molecules and interactions, and signal transduction pathways. Il1a, Il1b and Il22 were upregulated in the CHS, and Tnf, Tnfrsf1b, Il1b, Il1r1 and Il6 were upregulated in the SSS. Trpc1 channel genes were observed in representative itching-related candidate genes. By comparing and analyzing RNA-sequencing data obtained from the skin tissue of each animal model in these characteristic stages, it is possible to find useful diagnostic markers for the treatment of itching, to diagnose itching causes and to apply customized treatment.

Performance Comparison of 28 GHz Array Antennas for 5G Mobile Devices (5G 단말용 28 GHz 배열안테나의 안테나 타입별 성능 비교 연구)

  • Kim, Sun-Ryul;Hong, Young-Taek;Bang, Ji-Hoon;Choi, Jae-Hoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.30 no.1
    • /
    • pp.45-53
    • /
    • 2019
  • In this paper, three types of array antennas for 5G mobile devices operating at 28 GHz were designed, and their performances were compared. The isolation between antenna elements was compared based on $S_{21}$. The $S_{21}$ of dipole, slot, and patch type are -13.76 dB, -16.88 dB, and -11.47 dB, respectively, with the slot-type antenna having the highest isolation. In order to compare the beam coverage performance, several characteristics such as beam width and maximum beam steering angle were analyzed. The analysis shows that the slot type has the widest steering angle of $63^{\circ}$ while the patch type has narrowest with $36^{\circ}$. In addition, to verify the performance of the antennas in the actual usage environment of the device, antenna characteristics in talk mode and data mode were analyzed through simulation. The results confirmed that the slot-type array antenna is the most suitable array antenna element for 28 GHz 5G mobile devices.

Development of a Dynamic Downscaling Method using a General Circulation Model (CCSM3) of the Regional Climate Model (MM5) (전지구 모델(CCSM3)을 이용한 지역기후 모델(MM5)의 역학적 상세화 기법 개발)

  • Choi, Jin-Young;Song, Chang-Geun;Lee, Jae-Bum;Hong, Sung-Chul;Bang, Cheol-Han
    • Journal of Climate Change Research
    • /
    • v.2 no.2
    • /
    • pp.79-91
    • /
    • 2011
  • In order to study interactions between climate change and air quality, a modeling system including the downscaling scheme has been developed in the integrated manner. This research focuses on the development of a downscaling method to utilize CCSM3 outputs as the initial and boundary conditions for the regional climate model, MM5. Horizontal/vertical interpolation was performed to convert from the latitude/longitude and hybrid-vertical coordinate for the CCSM3 model to the Lambert-Conformal Arakawa-B and sigma-vertical coordinate for the MM5 model. A variable diagnosis was made to link between different variables and their units of CCSM and MM5. To evaluate the dynamic downscaling performance of this study, spatial distributions were compared between outputs of CCSM/MM5 and NRA/MM5 and statistic analysis was conducted. Temperature and precipitation patterns of CCSM/MM5 in summer and winter showed a similar pattern with those of observation data in East Asia and the Korean Peninsula. In addition, statistical analysis presented that the agreement index (AI) is more than 0.9 and correlation coefficient about 0.9. Those results indicate that the dynamic downscaling system built in this study can be used for the research of interaction between climate change and air quality.

Surface Deterioration Diagnosis of Taejong Heonreung Sindobi Monument using Nondestructive Method (비파괴 기법을 이용한 태종 헌릉 신도비의 표면 훼손도 진단)

  • Lee, Myeong-seong;Park, Sung-mi;Chun, Yun-gun;Lee, Sun-myung;Lee, Jae-man
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.4
    • /
    • pp.90-107
    • /
    • 2013
  • The Stone Monument of Taejong King in Heonreung Royal Tomb, Seoul was originally erected in 1424 to pay a tribute to Bang Won Lee's achievement who was named Taejong, the Third King of Joseon Dynasty. The monument has been damaged by Japanese Invasion of Korea in 1592 so that another monument was newly made and erected together with the original monument in 1695. The original monument was made of medium-grained biotite granite for the turtle base and medium-grained milky white crystalline limestone for the stele body and the top stone. The turtle base of the original monument is destroyed beyond the original shape and inscription due to irregular shaped breaking and a set of longitudinal crack. Analyzing the deterioration degree by using nondestructive methods, the 88 percentage of the front area and 38 percentage of the back area of the monument are damaged, and the lower part of the stele body is dominantly deteriorated especially due to the combination of discoloration and physical deterioration. The new monument in 1695 is also made of granite and limestone. The weathering indices of the turtle base and stele body stones by the calculation from ultrasonic velocity are 0.10 and 0.74, respectively. This is because the original monument is presumed to be degraded by heat shock and physical attack during the Japanese war, and the long-term outdoor exposure accelerated the weathering of the monument afterward without protective shelter.

Design of I-123 Nuclide production system (I-123 핵종생산장치 시스템 설계)

  • Jung, Hyun-Woo;You, Jae-Jun;Kim, Byung Il;Chun, KwonSoo;Lee, Ji-Seub;Park, Hyun;Choi, JunYong;Oh, Se-Young;Bang, Sang-Kwon;Lee, Dong Hoon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.05a
    • /
    • pp.496-499
    • /
    • 2014
  • Xe Gas is moved to Target from GPM. It is Used to feasible nuclear reaction from proton of 30MeV Cyclotron being investigated by the Xe-124 Gas target System. This system is divided into four parts. Hardware was constructed by solidworks and Helium Supply is to cool the Havor Foil. Water has the job of cooling down the temperature when Xe Gas is being investigated in the target. Temperature and pressure gauges are attached to be checked easily. GPM(Gas Process Manifold) has the part that prepares to transport Xe Gas. There are Storage Vessel that stores Xe Gas, the cold trap that filters humidity and impurity and lastly storage vessel that temporarily stores Xe Gas. HCS(Helium Circulation System) using the Helium to cleaning and cooling. these parts are used to SIEMENS PLC and Pcvue Program. Because It is more comfortable and easy maintenance.

  • PDF

Pile-cap Connection Behavior between Hollow-Head Precast Reinforced Concrete Pile and Foundation (프리캐스트 철근콘크리트 중공 말뚝과 기초 접합부 반복가력 거동)

  • Bang, Jin-Wook;Jo, Young-Jae;Ahn, Kyung-Chul;Kim, Yun-Yong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.1
    • /
    • pp.71-77
    • /
    • 2019
  • Recently, most of the pile foundations have been applied as a method to transfer the heavy load of the structure to the ground with high bearing capacity. In this study, the pile-cap behavior between foundation and hollow-head precast reinforced concrete(HPC) pile reinforced with longitudinal rebar and filling concrete was experimentally evaluated depending on the cyclic load and reinforcement ratio. As the drift ratio increases, it was found that the cracks pattern and fracture behavior of two types of pile-cap specimens according to the reinforcement ratio were evaluated to be similar. As the reinforcement ratio increases by 1.77 times, the BS-H25 specimen increases the maximum load by 1.47 times compared to the BS-H19 specimen. However, the ductility ratio of positive and negative was decreased by 76% and 70% respectively. After the yielding of the pile-cap reinforcing rebars, the positive and negative stiffness of the all specimens were decreased by a range from 66% to 71% and a range from 54% to 57% respectively, and the average stiffness of BS-H25 specimen is 13% higher than that of BS-H19 specimen. The cumulative dissipated energy capacity of BS-H19 and BS-H25 specimen under ultimate load state is 5.5 times and 6.6 times higher than that of service load state.

Characteristics and Clinical Course of Fusiform Middle Cerebral Artery Aneurysms According to Location, Size, and Configuration

  • Seo, Dongwook;Lee, Si Un;Oh, Chang Wan;Kwon, O-Ki;Ban, Seung Pil;Kim, Tackeun;Byoun, Hyoung Soo;Kim, Young Deok;Lee, Yongjae;Won, Yu Deok;Bang, Jae Seung
    • Journal of Korean Neurosurgical Society
    • /
    • v.62 no.6
    • /
    • pp.649-660
    • /
    • 2019
  • Objective : To analyze the angiographic features and clinical course, including treatment outcomes and the natural course, of fusiform middle cerebral artery aneurysms (FMCAAs) according to their location, size, and configuration. Methods : We reviewed the literature on adult cases of FMCAAs published from 1980 to 2018; from 25 papers, 112 FMCAA cases, for which the location, size, and configuration could be identified, were included in this study. Additionally, 33 FMCAA cases in our hospital were included, from which 16 were assigned to the observation group. Thus, a total of 145 adult FMCAA cases were included. We classified the FMCAAs according to their location (l-type 1, beginning from prebifurcation; l-type 2, beginning from bifurcation; l-type 3, beginning from postbifurcation), size (small, <10 mm; large, ${\geq}10mm$; giant, ${\geq}25mm$), and configuration (c-type 1, classic dissecting aneurysm; c-type 2, segmental ectasia; c-type 3, dolichoectatic dissecting aneurysm). Results : The c-type 3 was more commonly diagnosed with ischemic symptoms (31.8%) than hemorrhage (13.6%), while 40.9% were found accidentally. In contrast, c-type 2 was more commonly diagnosed with hemorrhagic symptoms (14.9%) than ischemic symptoms (10.6%), and 72.3% were accidentally discovered. According to location, ischemic symptoms and hemorrhage were the most frequent symptoms in l-type 1 (28.6%) and l-type 3 (34.6%), respectively. Most of l-type 2 FMCAAs were found incidentally (68.4%). Based on the size of FMCAAs, only 11.1% of small aneurysms were found to be hemorrhagic, while 18.9% and 26.0% of large and giant aneurysms were hemorrhagic, respectively. Although four aneurysms of the 16 FMCAAs in the observation group increased in size and one aneurysm decreased in size during the observation period, no rupture was seen in any case and there were no significant predictors of aneurysm enlargement. Of 104 FMCAAs treated, 14 cases (13.5%) were aggravated than before surgery and all the aggravated cases were l-type 1. Conclusion : While ischemic symptoms occurred more frequently in l-type 1 and c-type 3, hemorrhagic rather than ischemic symptoms occurred more frequently in l-type 3 and c-type 2. In case of l-type 1 FMCAAs, more caution is required in determining the treatment due to the relatively high complication rate.