• Title/Summary/Keyword: Balloon Shape

Search Result 25, Processing Time 0.02 seconds

Development of Sharpness Measuring Method for Glass Aggregate Particle made from Waste Glass Bottle

  • Sano, Shigeru;Yamada, Mari
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.76-79
    • /
    • 2001
  • In Japan in of today, there is no aspect in which the quantity of waste glass bottle discharged from ordinary homes decreases. Moreover, the kind of shape and color of the waste glass bottles are increasing little by little. In the recycling of the glass bottle, it becomes a problem that many kind of the color is abounding. It is possible to use the transparent glass bottle as raw material of the glassware. Since the reproduction of the color is difficult, the colored glass bottle is not possible to use as a raw material. Therefore, the processing of these glass bottles entirely depends on the reclamation. In Japan, the security of the new reclaimed land is very difficult for the reason of the environmental damage. Moreover, the life expectancy in many reclaimed lands is anticipated with within two years. Therefore, the development of the processing method of glass bottle other than reclamation becomes a rapid problem. At present it is examined that it is used of an aggregate of the colored pavement, as one of the application methods of colored glass bottle. The particle size of produced glass aggregate is also 5mm or less, because the thickness is 5mm or less on almost glass bottles. And almost glass particles have the sharp tip. The application as the aggregate is limited for this sharpness of the particle. This study was carried out for the purpose of the establishment of sharpness measuring method of the glass aggregate particle. It is possible that the injury degree to human in the handling is known, if showing the sharpness of the aggregate particle at the objective numerical value is possible. And the application of the glass aggregate is spread. In this research, the balloon fracture method was used for the sharpness measurement of the glass particle. This method is based on the completely new idea, and it is possible to express completely the possibility of injury to the human. It is reported with the detailed result in full paper, because this study is continuous in order to get the JIS which is industrial standard of Japan.

  • PDF

Prediction of the Unwinding Performance of Optical Fiber Cables by Nonlinear Dynamics Analysis (비선형 동적 거동 해석을 통한 광섬유 케이블의 풀림 성능 예측 연구)

  • Lee, Jae-Wook;Kim, Kun-Woo;Kim, Hyung-Ryul;Yoo, Wan-Suk;An, Deuk-Man
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.3
    • /
    • pp.347-352
    • /
    • 2010
  • Under harsh environments in which remote control is impossible, wire-guided control technology is effective for controlling distant underwater vehicles that serve mother ships in missions, such as exploration and installation. When the fiber is unwound from the spool, tension fluctuations occur in the fiber because of the relative velocity of the moving vehicles and unwinding velocity of the fiber. As a result, fiber cables exhibit complicated behaviors, become entangled, and may get cut. In this study, a spool-like design for winding tens of kilometers of fiber cables is proposed by analyzing cable winding. The unwinding performance of the designed spool is estimated by performing nonlinear dynamics analysis of the nonlinear behavior and tension fluctuations observed during the unwinding of the fiber.

Material Design and Analysis of Coronary Artery Stents (관상동맥혈관용 스텐트의 구조해석과 재료설계)

  • Park, Joong-Gwun;Kang, Tae-Won;Lee, Kee-Sung;Kim, Tae-Woo
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.7
    • /
    • pp.362-367
    • /
    • 2007
  • Stent is a tiny structure made with either ceramic coating and/or bare metal. Being approximately $1{\sim}2 mm$ in diameter, it consists of holes, slots, or void space and is designed to cover entire medical lesions. Stent implantation into patients' arteries has been practiced for a little more than a decade in order to widen the blocked artery. The adoption of the stent has significantly improved the efficacy when compared with the previous medical practice by balloon angioplasty alone. Yet better biomedical performance of the stent is being demanded in order to eliminate the still existing problem of artery restenosis, which means the artery becomes narrowed again. Recent literature survey shows researches on ceramic coatings onto the stent surface, or material design to improve the mechanical response of the stent. This study focuses more on the material design and mechanical analysis. The results showed that the void configuration within the stent affects the mechanical response significantly. The rectangular shape was found to yield expansion at a relatively lower pressure than the elliptical slot for a slotted tube stent. The present results, when combined with research on coating at the stent surface, may provide stents with improved bio-medical performance.

The Consideration of the Region of Interest on $^{99m}Tc$-DMSA Renal Scan in Pediatric Hydronephrosis Patients (수신증을 진단 받은 소아 환자의 DMSA 신장 검사에서 정확한 관심영역 설정에 대한 고찰)

  • NamKoong, Hyuk;Lee, Dong-Hyuk;Oh, Shin-Hyun;Cho, Seok-Won;Park, Hoon-Hee;Kim, Jung-Yul;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.27-33
    • /
    • 2012
  • Purpose: Most of diagnosis in the pediatric hydronephrosis patients have been performed $^{99m}Tc$-DMSA renal scan. Then the region of interest (ROI) is set for comparative analysis of uptake ratio in left-right kidney after acquiring the image. But if the equipment set an automatic ROI, the ROI could include expanded renal pelvis due to hydronephrosis and the uptake ratio of left-right kidney will be incorrect result. Therefore this study compared both ROIs including expanded renal pelvis and excluding renal pelvis through experiment using normal kidney phantom and expanded renal pelvis phantom and suggested setting method of improved ROI. In addition, this study have been helped by readout doctor for investigate distinction radiopharmaceutical uptake between renal cortex and remained urine by expanded renal pelvis. Materials and Methods: The both of renal phantoms were filled with water and shacked with $^{99m}TcO_4$ 111 MBq. In order to describe the expanded renal pelvis, the five latex balloon were all filled with 10 mL water and each of balloon was mixed with $^{99m}TcO_4$ 18.5, 37, 55.5, 74, 92.5 MBq. And we made phantom with fixed $^{99m}TcO_4$activity of 37 MBq and mixed water 5, 10, 15, 20, 25 mL in each balloon. The left kidney was fixed its shape and the right kidney was modified like as hydronephrosis kidney by attached the latex balloons. And the acquiring counts were 2 million. After acquisition, we compared the image of ROI with Expanded renal pelvis and the image of ROI without renal pelvis for analyzing difference in the uptake ratio of left-right kidney and for reproducibility, set the ROI 5 times in the same images. Patients were injected $^{99m}Tc$-DMSA 1.5~1.9 MBq/kg and scanned 3 to 4 hours after injection. The each of 3 skillful radio technologists performed the comparing estimation by setting ROI. To determine statistical significance between two data, SPSS (ver. 17) Wilcoxon Signed Ranks Test was used. Results: As a result of renal phantom's experiment, we compared with average of counts Background (BKG) ratios in the setting of ROI including expanded renal pelvis and setting of excluding expanded renal pelvis. Therefore, they can obtain changed counts and changed ratios. Patient also can obtain same results. In addition, the radiopharmaceutical uptake in expanded renal pelvis was come out the remained urine that couldn't descend to ureter by the help of readout doctor. Conclusion: As above results, the case of setting ROI including expanded renal pelvis was more abnormally increasing uptake ratio than the case of setting ROI excluding expanded renal pelvis in analysis the uptake ratio in left-right kidney of hydronephrosis. Because of the work convenience and prompted analysis, the automatic ROI is generally used. But in case of the hydronephrosis study, we should set the manual ROI without expanded renal pelvis for an accurate observation of the uptake ratio of left-right kidney since the radiopharmaceutical uptake in expanded renal pelvis is the remained urine.

  • PDF

Retroperitoneal Abscess Caused by Staphylococcus intermedius in a Dog (개에서 Staphylococcus intermedius에 의한 복막후농양 발생례)

  • Lee, Sang-Gwan;Hoh, Woo-Phil;Eom, Ki-Dong;Lee, Keun-Woo;Oh, Tae-Ho
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.176-180
    • /
    • 2009
  • Two year-old female miniature schnauzer was presented with depression, abdominal pain and inappetence. Physical examination revealed tachypnea, fever, and abdominal pain. Leukocytosis with neutrophilia was shown in complete blood count. Radiograph revealed the increase of opacity in parallel to vertebra and dislocation of descending colon. Calculi and sludge in bladder, hydronephrosis and dilation of proximal ureter in right kidney were observed in ultrasonographic examination; also, irregular shape of structure in retroperitoneal cavity was observed. Urinalysis showed protein urine and hemtauria. Many epithelial cells, spindle cells, calcium oxalate dihydrate crystals, struvite crystals, amorphous crystals and granular casts, WBC, cocci were examined in urine sediment test. ERD-kit test result was highly positive. Based on those test and excretory urogram pyelonephritis and complete unilateral obstruction of ureter were confirmed. A balloon type structure in retroperitoneal cavity was found through the exploratory laparotomy. In cytologic examination of aspirated fluid from dilated area many degenerated neutrophils and phagocytized cocci were observed. Staphylococcus intermedius was cultured from aspirated fluid. Based on these clinical results retroperitoneal abscesses caused by Staphylococcus intermedius was diagnosed with ureter obstruction and concurrent cystic calculi. Nephrectomy of right kidney with ureter was performed.