• Title/Summary/Keyword: Ballast water treatment system

Search Result 65, Processing Time 0.031 seconds

Analysis of Disinfection Performance of UV LEDs for a Phytoplankton (식물성 플랑크톤에 대한 UV LED의 살균성능 분석)

  • Kil, Gyung-Suk;Choi, Sung-Kuk;Park, Dae-Won;Kim, Sung-Wook;Cheon, Sang-Gyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.6
    • /
    • pp.959-964
    • /
    • 2009
  • This paper dealt with the disinfection performance by Ultra-Violet Light Emitting Diode (UV LED) for a phytoplankton as a basic study for the development of a low-energy consumption ballast water treatment system. UV LEDs having peak wavelength of 255nm, 265nm and 280nm were used in the experiment. UV LED modules with driving circuit were fabricated, and optical and electrical characteristics of them were analyzed. The disinfection performance for phytoplankton depending on the UV wavelength was evaluated by comparing the number of phytoplankton before and after the UV treatments. The experimental result showed that the highest disinfection wavelength for the phytoplankton was 265nm.

A Study of Characteristics on Water Quality and Phytoplankton in Ship's Ballast Water Originating from International Ports of China (우리나라 주요 국제항에 입항하는 중국 기원 선박의 평형수내 수질 및 식물플랑크톤 특성 연구)

  • Jang, Pung-Guk;Hyun, Bonggil;Jang, Min-Chel;Shin, Kyoungsoon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.7
    • /
    • pp.821-828
    • /
    • 2016
  • The water quality and phytoplankton presence in the ballast water (BW) of 37 vessels originating from the international ports of China were investigated to facilitate negotiations for exemptions to the Ballast Water Management Convention (BWM Convention). The shortest duration given BW spent in a vessel was $3.91{\pm}4.61days$ in area "A", which included the Bohai Sea. Total suspended solids, dissolved organic carbon, and particulate organic carbon ranged from 1.80 to $266mg\;L^{-1}$, from 1.09 to $5.79mg\;L^{-1}$, and from 0.17 to $3.65mg\;L^{-1}$, respectively. A low average concentration of nutrients was measured in BW from area "C", but the concentration of nutrients in BW from area "B" (around the Changjiang estuary) was high, which may be related to the relevant supply of freshwater. A high chlorophyll-a concentration (> $1{\mu}g\;L^{-1}$) was measured in six vessels, three of which carried BW in the area "A". High abundance of phytoplankton (> $10,000cells\;L^{-1}$) was measured in four vessels, two of which carried BW in the area "C". Vessel No. 37, originating from Hong Kong Bay in area "C", showed a high density of dinoflagellates. The results suggest that BWM Convention exemption negotiations with China should be performed cautiously.

Remote Communication of sensor data in Ballast Water Treatment System (선박 평형수 처리 시스템에서 센서 데이터의 원격 통신)

  • Kim, Chin-Hoon;Kim, Joo-Man;Kim, Byoung-Chul
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.6
    • /
    • pp.139-147
    • /
    • 2014
  • The ballast water may be discharged into another sea area with marine organisms, it caused problems to disturb the marine ecosystem. So, in order to remove these environmental risk factors, the IMO has mandated the installation of BWTS to the all ships. Our monitoring system diagnose and predict a failure of BWTS by analyzing the sensor information of BWTS collected from which the ships scattered in the ocean of several. This paper presents the design and implementation of communication modules for BWTS remote monitoring considering the satellite communication charge fee. In the our study, we implemented the safety and cost-saving communication modules by LabVIEW program. The collected sensor informations is encrypted and compressed by LabVIEW modules running on RIO. Then they will be transfer to the land server and will be decrypt to enable monitoring in the land server. For the verification, we build the test modules which can verify from collecting the sensor data to consuming them in the monitoring server. We carried out 20 times for the data pattern in all of case. So, we verified the excellent functionality and reliability through the experimental result.

An Application of AHP for the Selection of Optimum Product of BWTS for over 10,000 TEU Container Ship (AHP 기법을 이용한 10,000 TEU 이상 컨테이너선에 적용되는 선박평형수 처리장치 최적제품 선정에 관한 연구)

  • Lee, Sang-Won;Kim, Dong-Joon;Seo, Won-Chul
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.5
    • /
    • pp.395-406
    • /
    • 2015
  • The Ballast Water Treatment System was developed to prevent the unintended transport of unwanted organisms from one region to another as demanded by the IMO (International Maritime Organization). Although various types of BWTS in the world have been developed until now and applied to various ships, there has been no systematic basis for its selection and installation. Currently, the system selection and installation are as per ship owner’s suggestion or by easy installation point of view by the shipyard. In order to organize, systemize and solve problems related to the selection and installation of BWTS, a definitive study has been performed to come up with the best alternative to derive value and criteria which were to be met for vessels which are to be equipped with BWTS. Multiple criteria were compared alongside each other during the course of this study. Accordingly an AHP (Analytic Hierarchy Process) analysis method for A, B and C companies were done for container ships with size 10,000 TEU and above. Equipment type for “A” company is “Filter, UV & TiO2” combined type. For “B” company it is “Filter & UV” combined type. Finally for “C” company it is “Electrolysis” type. Henceforth, the results of this study aims to come up with the optimum way to select the best and the most suitable BWTS for a certain vessel.

Efficiency of concentrating marine microplanktonic organisms using net sampler to verify the efficacy of a ship's ballast water treatment system (USCG phase-II 선박평형수 처리장치 성능 평가에 대비한 해양식물플랑크톤 네트 농축효율 비교)

  • Baek, Seung Ho;Lee, Min Ji;Shin, kyoungsoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.136-143
    • /
    • 2016
  • To provide a type approval test for Ballast Water Treatment System (BWTS) of United States Coast Guard (USCG) Phase-II, this study examined the concentrating efficiency of nets for ${\geq}10{\mu}m$ and ${\leq}50{\mu}m$ sized phytoplanktonic organisms using different mesh sized nets ($5{\mu}m$ or $7{\mu}m$), different injection methods (hand breaker as semi-continuous assessment or pump as continuous assessment), and different filterability for the water volume. As a result of the t-test, the net concentrated efficiency between $5{\mu}m$ and $7{\mu}m$ mesh size was not significant (p > 0.05). The difference in the net concentrated efficiency for filtered natural water volume was not significant (p > 0.05). On the other hand, the Chl.a concentration in the continuous water injection method was significantly (p < 0.05) higher than that of semi-continuous water injection (t-test: t: -4.058). In the natural phytoplankton community, a total of 36 species were identified, including Bacillariophyta (17 species), Dinophyta (15 species), Euglenophyta (1 species), Dictyochophyta (2 species), and unidentified taxa (1 species). Among them, diatom Pseudo-nitzchia spp. was remarkably dominant. In particular, the net concentrated efficiency in all assessments was underestimated to be approximately 20-25%, which was caused by the small size Pseudo-nitzchia spp.. A width size of these genus might have passed through the $5{\mu}m$ or $7{\mu}m$ mesh size of the net. Therefore, net concentrated efficiency is dependent on the size of the observed species in natural water. This issue should be considered when determining the net volume for the type approval test of BWTS.

The Study on the Marine Eco-toxicity and Ecological Risk of Treated Discharge Water from Ballast Water Management System Using Electrolysis (전기분해원리를 이용한 선박평형수관리장치의 배출수에 대한 해양생태독성 및 해양환경위해성에 관한 연구)

  • Shon, M.B.;Son, M.H.;Lee, J.;Son, Y.J.;Lee, G.H.;Moon, C.H.;Kim, Y.S.
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.16 no.2
    • /
    • pp.88-101
    • /
    • 2013
  • The International Convention for the Control and Management of Ship's Ballast Water and Sediments was adopted at 2004 and then various BWMS (ballast water management system) have been developed. In this study, WET (whole effluent toxicity) test with algae (diatom) Skeletonema costatum as primary producer, invertebrate (rotifera) Brachionus plicatilis as 1st consumer and fish (olive flounder) Paralichthys olivaceus as predator, chemical analysis and ERA (environmental risk assessment) were conducted to assess the unacceptable effect on marine ecosystem by emitting the discharge water treated with AquaStar$^{TM}$ BWMS using electrolysis as main treatment equipment for removing the marine organisms in the ship's ballast water. The most sensitive test organism on discharge water treated with AquaStar$^{TM}$ BWMS was S. costatum that gave the NOEC value of 25.00%, LOEC value of 50.00% and 72hr-$EC_{50}$ value of 69.97% from WET test result for 20 psu salinity treated discharge water. NOEC and LOEC value of B. plicatilis and P. olivaceus exposed at 20 psu salinity treated discharge water were 50.00% and 100.00%, respectively. In the chemical analysis results, total number of substances produced by AquaStar$^{TM}$ BWMS was 18 which were bromate, 7 volatile halogenated organic compounds, 7 halogenated acetic acids, 3 halogenated acetonitriles and chloropicrin. Eighteen substances did not consider as persistence and bioaccumulative chemicals. Uncertainty of toxic property of 18 substances was high. PECs of 18 substances calculated by MAMPEC model were ranged from $4.58{\times}10^{-4}$ to $4.87{\mu}g\;L^{-1}$, PNECs of them were ranged from $1.6{\times}10^{-2}$ to $3.2{\times}10^2{\mu}g\;L^{-1}$. And, the PEC/PNEC ratio of 18 substances did not exceed 1. Therefore, ERA for produced substances indicate that the discharge water treated with AquaStar$^{TM}$ BWMS does not pose unacceptable effect on marine life. And $EC_{50}$ value of S. costatum on discharge water treated by BWMS using the electrolysis had positive correlation with initial TRO concentration, concentration and kind & level of HAAs.

Treatment of ballast water by complex process of advance filtration system

  • Park, Sang-Ho;Kim, In-Soo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.1
    • /
    • pp.387-392
    • /
    • 2006
  • There have been several problems in treating shipboard sewage due to special environmental conditions of ship, such as limited space, rolling and pitching, change of temperature and so on. It was suggested that Sequence Batch Reactor (SBR) might be suitable process for overcome these problems in terms of small size, high capacity of treating wastewater and full automation. In this study a SBR process was employed for biological treatment of organic wastes in the shipboard sewage. This process was able to remove nitrogen and phosphorus as well as organic matter efficiently. More than 95% of chemical oxygen demand(COD) were removed. In addition, about 97% of total nitrogen (T-N) was reduced. The total phosphorus(T-P) reduction averaged 93%. A disturbance operation caused by the treatment of Methylene Blue Active Substances(MBAS) was not observed.

  • PDF

A Study on Suction Pump Impeller Form Optimization for Ballast Water Treatment System (선박평형수 처리용 흡입 펌프 임펠러 형상 최적화 연구)

  • Lee, Sang-Beom
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.25 no.1
    • /
    • pp.121-129
    • /
    • 2022
  • With the recent increase in international trade volume the trade volume through ships is also continuously increasing. The treatment of ballast water goes through the following five steps, samples are taken and analyzed at each step, and samples are obtained using a suction pump. These suction pumps have low efficiency and thus need to be improved. In this study, it is to optimize the form of the impeller which affects directly improvements of performance to determine the capacity of suction pump and to fulfill the purpose of this research. To do it, we have carried out parametric design as an input variable, geometric form for the impeller. By conducting the flow analysis for the optimum form, it has confirmed the value of improved results and achieved the purpose to study in this paper. It has selected the necessary parameter for optimizing the form of the pump impeller and analyzed the property using experiment design. And it can reduce the factor of parameter for local optimization from findings to analyze the property of form parameter. To perform MOGA(Multi-Objective Genetic Algorithm) it has generated response surface using parameters for local optimization and conducts the optimization using multi-objective genetic algorithm. with created experiment cases, it has performed the computational fluid dynamics with model applying the optimized impeller form and checked that the capacity of the pump was improved. It could verify the validity concerning the improvement of pump efficiency, via optimization of pump impeller form which is suggested in this study.

A Study on Marine Ecological Risk Assessment of Ballast Water Management Technology Using the Sodium Dichloroisocyanurate (NaDCC) Injection Method (이염화이소시아뉼산나트륨(NaDCC) 주입 선박평형수 처리기술의 해양생태위해성평가에 대한 연구)

  • Kim, Tae Won;Moon, Chang Ho;Park, MiOk;Jeon, MiHae;Son, Min Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.2
    • /
    • pp.203-214
    • /
    • 2018
  • Ballast water treated by sodium dichloroisocyanurate (NaDCC) injection method in ballast water management system (BWMS) contains reactive bromine, chlorine species and disinfection by-products (DBPs). In this study, we conducted whole effluent toxicity (WET) testing and ecological risk assessment (ERA) to investigate its ecotoxicological effects on the marine environment. WET testing was carried out for eight marine and fresh water organisms, i.e. diatom, Skeletonema costatum, Navicula pelliculosa, green algae, Dunaliella tertiolecta, Pseudokirchneriella subcapitata, rotifer, Brachionus plicatilis, Brachionus calyciflorus and fish, Cyprinodon variegatus, Pimephales promelas. The WET test revealed that diatom and green algae were the only organisms that showed apparent toxicity to the effluent; it showed no observed effect concentration (NOEC), lowest observable effect concentration (LOEC) and effect concentration of 50 % (EC50) values of 25.0 %, 50.0 % and over 100.0 %, respectively, in seawater conditions. In contrast, rotifer and fish showed no toxicities to the effluent in the all salinity conditions. Meanwhile, chemical analysis revealed that the BWMS effluent contained total of 25 DBPs such as bromate, isocyanuric acid, formaldehyde, chloropicrin, trihalomethanes (THMs), halogenated acetonitriles (HANs) and halogenated acetic acids (HAAs). Based on ERA, the 25 DBPs were not considered to have persistency, bioaccumulation and toxicity (PBT) properties. The ratio of predicted environmental concentration (PEC) to predicted no effect concentration (PNEC) of the all DBPs did not exceed 1.0 for general harbour environments, but isocyanuric acid, tribromomethane, chloropicrin and monochloroacetic acid exceed 1.0 for near ship environments. However, when NOEC (25.0%) of the WET test results where actual effluent was applied, it was concluded that the NaDCC injection method did not have unacceptable ecological risks to the general harbor including near ship environments.

Ballast Water Treatment System using TiO2 Photocatalysts and UV lamps (광촉매와 자외선 램프를 이용한 선박평형수 처리장치)

  • Lee, Jung-Yoon;Cha, Sang-Wook;Kim, Il-Kwon;Park, Dae-Won;Kil, Gyung-Suk
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2011.10a
    • /
    • pp.70-70
    • /
    • 2011
  • 본 논문에서는 에너지 절감형 선박평형수 처리장치를 개발하기 위하여 $TiO_2$ 광촉매와 자외선 램프를 적용한 선박평형수 처리장치에 대하여 기술하였다. 제작된 처리장치의 정격 출력과 처리용량은 각각 2.16 kW 및 $100m^3/h$이다. 처리장치의 살균효율은 플랑크톤을 사용하여 IMO 규정에 따라 평가하였다. 실험결과로부터 시제작 선박평형수 처리장치의 살균효율은 동물성 플랑크톤에서 99.7 %, 식물성 플랑크톤에서 98.84 %로 나타났다.

  • PDF