• 제목/요약/키워드: Ball and Plate System

검색결과 47건 처리시간 0.023초

결합된 퍼지 제어기를 이용한 볼과 플레이트 시스템에서의 추정제어기 설계 (Tracking Control of Ball and Plate System via Integrated Fuzzy Controllers)

  • 서민석;현창호;박민용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년 학술대회 논문집 정보 및 제어부문
    • /
    • pp.223-225
    • /
    • 2006
  • A ball moving on a beam is a typical nonlnear dynamic system, which is often adopted to proof test diverse control schemes. Ball and plate system is the extension of the traditional ball and beam problem that moves a metal ball on a rigid plate. In this paper, a trajectory planning and tracking problem is proposed for ball and plate system, which is to control the ball from a point to another without hitting the obstacles. Our scheme is composed of three controllers, TS type optimal path tracking controller, mandani type obstacle avoidance controller and trajectory planning controller that determines the desired trajectory. But this type of construction can give rise to chattering executions. Because the difference of contributions from concurrent controllers can cause behaviors unsmoothly. We propose fuzzy pid supervision control1er to handle this problem.

  • PDF

세라믹 볼을 이용한 판형열교환기 세정장치의 볼 회수율 측정 (The Measurements of Ball Recovery Rate for the Cleaning Apparatus in Plate Heat Exchanger Using Ceramic Ball)

  • 채희만;권정태;차동안;권오경
    • 동력기계공학회지
    • /
    • 제18권1호
    • /
    • pp.38-44
    • /
    • 2014
  • The objectives of this study are to measure the ball recovery rate of cleaning apparatus for plate heat exchanger. Ceramic ball is used for plate heat exchanger cleaning. The main components of cleaning apparatus are comprised of ball collector, ball trap, ejector, pump and plate heat exchanger. The ball recovery rate are obtained with change in recovery time and velocity of water. The results show that the ball recovery rate is slightly increased with increase in the recovery time and the velocity of water over 0.4 m/s in the straight flow. In the case of reverse flow, the ball recovery rate more increased than straight flow. The maximum ball recovery rate of the straight flow and reverse flow reach 83.97% and 86.61%, respectively, when the velocity and cleaning time are 0.5 m/s and 15min.

단일 Camera를 이용한 Ball and Plate 로봇 제어장치 설계 (Design of Ball and Plate Robot controller using Single Camera)

  • 박이근;박주연;박성모
    • 한국멀티미디어학회논문지
    • /
    • 제16권2호
    • /
    • pp.213-225
    • /
    • 2013
  • 본 논문에서는 단일 카메라와 2개의 모터를 이용하는 볼-플레이트 로봇제어장치를 설계하는 방법과 제어 오차를 줄이는 방법을 제안한다. 볼-플레이트 시스템을 설계하기 위해서는 볼의 상태 파악과 플레이트의 균형 유지가 필요하다. 볼의 상태는 캠시프트 알고리즘을 이용하여 추적하고 칼만필터로 공의 위치 오차를 보정한다. 플레이트 균형은 두 개의 모터를 움직여 제어하는데 측정 오차가 적은 DC모터를 사용하였다. 플레이트의 표면적 상태나 공의 위치 추적오류 등을 인하여 작은 오차가 여전히 남아있다. 이러한 오차는 점점 쌓이게 되며 결국은 볼의 균형유지를 방해하게 된다. 이를 해결하기 위해 적분기를 추가한 제어기를 제안한다.

A Study on the design of separation force measuring system for improvement of semiconductor productivity

  • Park, Kun-Jong
    • 한국컴퓨터정보학회논문지
    • /
    • 제22권10호
    • /
    • pp.1-7
    • /
    • 2017
  • In this paper, the separation force measuring system is developed. The separation force aries due to adhesive strength between semiconductor epoxy molding compound(EMC) and the metal plate in semiconductor formed plate. In general, when removing the metal plate in semiconductor formed plate from semiconductor epoxy molding compound, excessive strength can result in a increase in semiconductor defect rates, or conversely, if too little force is exerted on the metal plate in semiconductor formed plate, the semiconductor production rates can decrease. In this study, the design criteria for the selection of the AC servo motor, the role of the ball screw, the relationship between the load cell and the ball screw, and the rate of deceleration are given. In addition, minimizing the reject rate of semiconductors and maximizing the semiconductor production rate are achieved through the standardization of the collected separation force data measured by the proposed system.

Ball-Plate 시스템을 위한 움직이는 공의 추적 (Tracking of Moving Ball for Ball-Plate System)

  • 박이근;박주연;박성모
    • 한국멀티미디어학회:학술대회논문집
    • /
    • 한국멀티미디어학회 2012년도 춘계학술발표대회논문집
    • /
    • pp.143-146
    • /
    • 2012
  • Ball-Plate를 기반으로 하는 균형제어 로봇은 크게 공의 상태를 파악하는 부분과 균형을 유지하는 제어부분 2가지로 구성되어진다. 본 논문은 공의 상태를 파악하기 위해서 단일 카메라를 이용하여 CAMShift 알고리즘으로 볼을 추적한다. 그리고 칼만 필터를 사용하여 발생하는 오차를 줄이는 방법을 제안하고 그 실험 결과에 대해서 설명한다.

  • PDF

ROS-based control for a robot manipulator with a demonstration of the ball-on-plate task

  • Khan, Khasim A.;Konda, Revanth R.;Ryu, Ji-Chul
    • Advances in robotics research
    • /
    • 제2권2호
    • /
    • pp.113-127
    • /
    • 2018
  • Robotics and automation are rapidly growing in the industries replacing human labor. The idea of robots replacing humans is positively influencing the business thereby increasing its scope of research. This paper discusses the development of an experimental platform controlled by a robotic arm through Robot Operating System (ROS). ROS is an open source platform over an existing operating system providing various types of robots with advanced capabilities from an operating system to low-level control. We aim in this work to control a 7-DOF manipulator arm (Robai Cyton Gamma 300) equipped with an external vision camera system through ROS and demonstrate the task of balancing a ball on a plate-type end effector. In order to perform feedback control of the balancing task, the ball is designed to be tracked using a camera (Sony PlayStation Eye) through a tracking algorithm written in C++ using OpenCV libraries. The joint actuators of the robot are servo motors (Dynamixel) and these motors are directly controlled through a low-level control algorithm. To simplify the control, the system is modeled such that the plate has two-axis linearized motion. The developed system along with the proposed approaches could be used for more complicated tasks requiring more number of joint control as well as for a testbed for students to learn ROS with control theories in robotics.

Verification of Periodical Calibration for Iso-center Positions using Quality Assurance System for Irradiation Equipment Position Established at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.192-194
    • /
    • 2002
  • We present the results on the calibration of iso-center positions using the quality assurance system established at PMRC for determination of center position in X-ray and proton irradiation fields. Details on the system are presented in another presentation in this session. The equipment in the system is mounted on a patient treatment bed in each proton exposure room, G1 or G2. A center of a stainless ball on the equipment is set at a cross of laser markers located around the iso-center and fixed on the room and on the snout in the gantry. A proton beam or an X-ray beam is exposed onto the ball through a brass collimator of 100 mm ${\times}$ 100 mm and projected onto the imaging plate set at I cm behind the ball. On the axis perpendicular to the thrust axis of the gantry on the imaging plate, a distance between a center of the collimator image and a center of the ball image varies as a cosine function of gantry angles unless the ball is set on the iso-center. An amplitude of the cosine curve shows the distance between the ball and the iso-center, an offset the offset of the collimator, and a phase shift at a zero crossing point the ball direction viewed from the iso-center. We present the relation among the iso-center position, the laser maker position, and the center of proton and X-ray irradiation fields. Its stability and its reproducibility are discussed.

  • PDF

Quality Assurance System for Determination of Center Position in X-ray and Proton Irradiation Fields using a Stainless Ball and Imaging Plates in Proton Therapy at PMRC

  • Yasuoka, Kiyoshi;Ishikawa, Satoko
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.189-191
    • /
    • 2002
  • In the proton therapy using a gantry system, periodical verification of iso-center position is very important to assure precision of patient positioning system at any gantry angles in proton treatment. In the gantry system, there are three different types of iso-center; 1) in a geometrical view, 2) in an X-ray beam's eye view, 3) in a proton beam's eye view. Idealistically, they would be an identical point. They could, however, be different points. It may be a source of errors in patient positioning. At PMRC, we have established a system of verification for iso-center positions using a stainless ball of 2-cm in diameter and an imaging plate. This system provides the relation among a center of a patient target position, a center of proton irradiation field, and/or a center of X-ray field in accuracy of 50$\square$m in the 2) and 3) views, as images of a center of the stainless ball and a center of a 100 mm${\times}$100 mm-aperture brass collimator recorded on the imaging plate, which is setup at 1-cm behind the ball. In addition, it provides simultaneously the images of the ball and the collimator on an imaging intensifier (II), which is setup downstream of the proton or X-ray beam. We present a method of quality assurance (QA) for calibration of iso-center position in a rotation gantry system at PMRC and the performance of this system. A proton beam position on the 1$\^$st/ scatterer in the nozzle of the gantry affects less sensitive (reduced by a factor of 1/5) to the results of the iso-center position. The effect is systematically correctable. The effect of the nozzle (or the collimator) position is less than 0.5 mm at the maximum extraction (390 mm).

  • PDF

하드 디스크 구동 스핀들 모터의 진동 특성에 관한 연구 (A Study on the Vibration Characteristics of HDD Spindle Motor)

  • 장건희;한재혁
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 춘계학술대회논문집; 경주코오롱호텔; 22-23 May 1997
    • /
    • pp.160-166
    • /
    • 1997
  • The spindle motor in a computer hard disk drive can be modeled as a rotor-bearing system supported by the base plate. Ball bearing is the crucial element to determine the stiffness of the spindle motor, and its design parameters and operating conditions determine the dynamic characteristics of the spindle motor. In the analysis of a rotor-bearing system with a short shaft like a spindle motor, the stiffness of the base plate as well as ball bearings must be considered accurately to analyze the dynamic charateristics of a spindle motor. In this paper, the lateral and the axial vibration of the spindle motor were analyzed by the transfer matrix method for the dual-shaft rotor-bearing model and by d.o.f lumped parameter model, respectively. The simulation results had good agreements with the experimental modal testing. The dynamic characteristics were fully investigated for the change of the major design parameters of the spindle motor, i.e. the preload of ball bearings and the rotational speed.

  • PDF

금속파편충격에 의한 강판의 가속도신호 특성 (Acceleration Signal Characteristics of Steel Plate Impacted by Metallic Loose Parts)

  • 성게용;윤용구
    • 비파괴검사학회지
    • /
    • 제12권2호
    • /
    • pp.21-29
    • /
    • 1992
  • Acceleration signal characteristics of a steel plate, impacted by steel balls, were studied in an attempt to apply the experimental results to the impact location and mass estimation of metallic loose parts in the cooling system of nuclear power plants. Experimental results show that the variation of maximum acceleration amplitude and impact contact time due to the change of ball mass and impact velocity can be well explained by the Hertz impact theory. The frequency spectral pattern shifted slightly in spite of the increase of impact velocity and impact location. Ball mass, however, strongly affected the frequency spectral pattern. Hence the frequency spectrum can be used for estimation of the mass of unknown loose parts in the cooling system.

  • PDF