• 제목/요약/키워드: Ball Bar

검색결과 118건 처리시간 0.022초

Configuration sensitivity analysis of mechanical dynamics

  • Bae, Daesung
    • 한국공작기계학회논문집
    • /
    • 제10권1호
    • /
    • pp.112-119
    • /
    • 2001
  • Design sensitivity is an important is an important device in improving a mechanical system design. A continuum design consists of the shape and orientation design. This research develops the shape and orientation design sensitivity method. The configura-tion design variables of multibody systems define the shape and orientation changes. The equations of motion are directly differentiated to obtain the governing equations for the design sensitivity. The governing equation of the design sensitivity is formulated as an over determined differential algebraic equation and treated as ordinary differential equations on mani-folds. The material derivative of a domain functional is performed to obtain the sensitivity due to shape and orientation changes. The configuration design sensitivities of a fly-ball governor system and a spatial four bar mechanism are obtained using the proposed method and are validated against those obtained from the finite difference method.

  • PDF

고성능 셀/패킷 스위치를 위한 고속 VOQ 관리기 설계 (Design of High-Speed VOQ Management Scheme for High Performance Cell/Packet Switch)

  • 정갑중;이범철
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.369-372
    • /
    • 2001
  • This paper presents the design of high-speed virtual output queue(VOQ) management scheme for high performance cell/packet switch, which has a serial cross bar structure. The proposed VOQ management scheme has been designed for wire-speed routing with a pipelined buffer management. It provides the tolerance of requests and grants data transmission latency between the VOQ manager and central arbiter using a new request control method that is based on a high-speed shifter. The designed VOQ manager has been implemented in a field programmable gate array chip with a 77MHz operating frequency, a 900-pin fine ball grid array package, and 16$\times$16 switch size.

  • PDF

Machining Center의 2차원 원호절삭정도 자동진단 System의 개발에 관한 연구

  • 김정순;남궁석;제정신
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 춘계학술대회 논문집
    • /
    • pp.9-12
    • /
    • 1992
  • 지금까지 공작기계의 성능은 주로 기하학적 운동정도, 위치결정정도, 공작정도등의 시험 및 검사에의해 평가되어왔다. 그러나, 공작기계의 수치제어 System으로서의 평가는 충분히 행히지고있지 않았다. 원호절삭 정도시험으로서 Direct Test법은 공작물을 직접절삭하기 때문에공구나, 공작물의 영향을 받아서 공작기계의 운동정도만을 검사하는 것은 곤란하다. 그래서 직접 절삭하지않고 원호절삭 원동정도를 평가할 수 있는 방법으로서 Circular test법과 Double Ball Bar법이 개발 되어 사용되고 있다. 본 연구에서는 상술한 2가지 방법의 대체 방법으로 간단하고 값싸게 제작할 수 있는 새로운 원호절삭 정도측정장치와 측정 system을 개발하여 이 측정기로측정한 원호형상과 Machining Center의 운동오차 요인과의 정량적으로 고찰하였다.

터보펌프용 극저을 베어링/실 성능시험설비 (Cryogenic Bearing and Seal Test Facility for a Turbopump)

  • 곽현덕;전성민;김진한
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.341-347
    • /
    • 2005
  • To perform a cryogenic development test for Tribo-elements in a turbopump, a cryogenic bearing and seal test facility (BSTF) is designed and currently under construction in KARI. The working fluid is liquid nitrogen operating at a temperature $-197^{\circ}C$. The maximum operating pressure and volume flow rate of BSTF are 100 bar and 10 liters per second, respectively. The development tests of floating ring seals, inter-propellant seals (IPS) and cryogenic ball bearings in a turbopump will be performed using the BSTF. This paper briefly described design requirements and procedures of BSTF.

  • PDF

공작기계의 오차요소 측정을 통한 3차원 위치정밀도 향상 (The enhancement of 3-dimensional positioning accuracy by measuring error factors for CNC machine tools)

  • 손진욱;서석환;정세용;이응석;위현곤
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.260-265
    • /
    • 1994
  • Efforts have been devoted to developing rapid and accurate methods for measuring the errors of machine tools. The method os measurement and calibration of machine tool errors should be general and efficient. The objective of this study is to show in detail the full sequence from the measurement of errors factors to the verification of the positioning accuracy after compensation for the volumetric error. In this paper, we described the steps in measuring the volumetric error parameters, a general error model composed of error parameters, temperature, and the desired position. The validity of the error calibration methods proposed in this paper was tested using a vertical 3-axis CNC machine with a laser interferometer and a ball bar.

  • PDF

2자유도 헵틱디바이스 설계 및 가상환경 모델링 기법에 관한 연구 (A study on the 2-DOF haptic device design and virtual environment modelling)

  • 성하경;범진환;이성호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 D
    • /
    • pp.2510-2512
    • /
    • 2002
  • In this paper, we investigated 2-DOF haptic device and the method of virtual environment modeling for virtual reality. We designed an modified five bar link system to improve the performance. The haptic control system is composed of calculating kinematics and statics, controlling actuator, and describing the virtual environment. Using this system, we realized the virtual spring model and the freely falling ball model.

  • PDF

NC선반의 원 운동정도 측정장치의 개발 (Developement of Measuring Units of circular Motion Accuracy on NC Lathe)

  • 김영석;김재열
    • 한국공작기계학회논문집
    • /
    • 제10권6호
    • /
    • pp.1-7
    • /
    • 2001
  • It is very important to test circular motion accuracy of NC machine tools as it affects all other machines machined by them in industries. In this paper, it has become possible to detect errors of linear displacement of radial directions for circle tar motion accuracy test using newly assembled magnetic type of linear scale so called Magnescale ball-bar system. It has also organized computer program systems using tick pulses come out from computer for getting error motion data at colt start time interval in circular motion test on NC lathe. Error data gotten from test is expressed to plots and analysed to numerics by various statistical treatments.

  • PDF

Machining Center의 공간정도 측정장치의 개발 (Developement of Measuring Units of Space Motion Accuracy in Machining Center)

  • 김영석;남궁석
    • 한국정밀공학회지
    • /
    • 제12권2호
    • /
    • pp.37-47
    • /
    • 1995
  • In recent years, it has been variously developed for testing the accuracy of circular motion of NC machine tools, for example Telescoping Ball Bar Method by Bryan, Circular test Method by Knapp and $r^{-{\theta} }$ Method by Tsutsumi etc., but these methods are all 2-dimentional measuring methods on plane. These simple methods of circular motion accuracy test of NC machine tools have been studied by many reserchers as above, but it is not yet settled in the code of measuring methods of motion errors of NC machine tools, because of errors of measuring units and sensors, and also especially the difficulties of centering of measuring units and the spindle of machining center. In this paper, in use of 2 rotary encoders and 1 magnetic type linear scale with resolution of 0.5 .mu. m, it has become possible for measuring of 3 dimentional space motion accuracy.

  • PDF

자동차 전장부품을 위한 Sn-0.5Cu-(X)Al(Si) 중온 솔더의 접합특성 연구 (A study of joint properties of Sn-Cu-(X)Al(Si) middle-temperature solder for automotive electronics modules)

  • 유동열;고용호;방정환;이창우
    • Journal of Welding and Joining
    • /
    • 제33권3호
    • /
    • pp.19-24
    • /
    • 2015
  • Joint properties of electric control unit (ECU) module using Sn-Cu-(X)Al(Si) lead-free solder alloy were investigated for automotive electronics module. In this study, Sn-0.5Cu-0.01Al(Si) and Sn-0.5Cu-0.03Al(Si) (wt.%) lead-free alloys were fabricated as bar type by doped various weight percentages (0.01 and 0.03 wt.%) of Al(Si) alloy to Sn-0.5Cu. After fabrications of lead-free alloys, the ball-type solder alloys with a diameter of 450 um were made by rolling and punching. The melting temperatures of 0.01Al(Si) and 0.03Al(Si) were 230.2 and $230.8^{\circ}C$, respectively. To evaluation of properties of solder joint, test printed circuit board (PCB) finished with organic solderability perseveration (OSP) on Cu pad. The ball-type solders were attached to test PCB with flux and reflowed for formation of solder joint. The maximum temperature of reflow was $260^{\circ}C$ for 50s above melting temperature. And then, we measured spreadability and shear strength of two Al(Si) solder materials compared to Sn-0.7Cu solder material used in industry. And also, microstructures in solder and intermetallic compounds (IMCs) were observed. Moreover, thickness and grain size of $Cu_6Sn_5$ IMC were measured and then compared with Sn-0.7Cu. With increasing the amounts of Al(Si), the $Cu_6Sn_5$ thickness was decreased. These results show the addition of Al(Si) could suppress IMC growth and improve the reliability of solder joint.

Implant and root supported overdentures - a literature review and some data on bone loss in edentulous jaws

  • Carlsson, Gunnar E.
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권4호
    • /
    • pp.245-252
    • /
    • 2014
  • PURPOSE. To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth. MATERIALS AND METHODS. Papers on alveolar bone loss and implant overdentures have been studied for a narrative review. RESULTS. Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture. CONCLUSION. In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.