차단전압 균형과 넓은 부하범위를 갖는 새로운 3-레벨 ZVS PWM DC-DC 컨버터 (A Novel Three-Level ZVS PWM Inverter Topology for High-Voltage DC/DC Conversion Systems with Balanced Voltage Sharing and Wider Load Range)

  • 송인호;유상봉;서범석;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1996년도 창립기념 전력전자학술발표회 논문집
    • /
    • pp.71-75
    • /
    • 1996
  • As the Three-level ZVS PWM DC-DC converter operates likewise full-bridge ZVS PWM DC-DC converter and the blocking voltage of each switching device is a half of the DC-link voltage, it is suitable for the high imput voltage applications. However, it has some problems as follows; The blocking voltage of each devices is unbalanced and it causes the power losses of the inner switching devices to be increased. Also, it has narrow load range so that the switching losses and the efficiency are reduced as it goes to the light load. This paper presents an nove Three-level ZVS PWM DC-DC converter, which can reduce the overvoltage of the outer switches, eliminate the unbalance of the voltage sharing between the switches at turn-off due to the stray inductances, and operate from no load to full load. The characteristics and the performances of the proposed Three-level ZVS PWM DC-DC converter are verified by simulation and experimental results

  • PDF

무정전전원장치의 병렬운전 제어기법에 관한 연구 (A Study on the Parallel Operation Control Technique of On-line UPS System)

  • 곽철훈;최규하
    • 전력전자학회논문지
    • /
    • 제8권6호
    • /
    • pp.585-592
    • /
    • 2003
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between Inverters on synchronous d-q reference frame.

전기자동차용 납축전지의 시분할 균등충전기 (Time-sharing Charge System for Equalization of Lead-Acid Battery)

  • 강신영;김광헌;임영철
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제11권2호
    • /
    • pp.94-101
    • /
    • 1997
  • 본 논문에서는 일정 주기마다 전지의 단자전압을 검출하여 단자전압에 따라 균등충전 시간을 시분할로 제어하여 전지간의 불균등을 해소시키는 균등 충전방식을 제안하였다. 기존의 균등 충전방식과 달리 구조가 간단하고 소형, 경량으로 전지자동차용 탑재형 균등 충전시스템으로 이용이 가능하다. 또한, 원칩 마이크로프로세서를 이용하여 일정 주기마다 단자전압을 검출하여 제어하므로 전지의 과충전을 예방할 수 있고, 따라서 전지 수명 연장에도 효과적이라 할 수 있다.

  • PDF

3-레벨 IGBT ZVS PWM DC/DC 컨버터의 성능 향상 (A Study on the 3-level IGBT ZBS PWM DC/DC Converter with High Performance)

  • 송인호;유상봉;현동석
    • 전력전자학회논문지
    • /
    • 제2권3호
    • /
    • pp.1-10
    • /
    • 1997
  • 3-레벨 ZVS PWM DC/DC 컨버터는 풀브리지 ZVS PWM DC/DC 컨버터와 같은 동작 특성을 가지면서 입력전압의 반을 스위칭 소자의 차단전압으로 갖기 때문에 높은 입력을 갖는 DC-DC 변환시스템에 적합한 구조라 할 것이다. 그러나 부유 인덕턴스의 영향으로 인한 내외측 소자간의 차단전압 불균형의 문제와 경부하에서 영전압 스위칭 동작을 하지 못하므로 부하범위가 작다는 문제점을 가지고 있다. 이와 같은 문제점들은 시스템의 신뢰도를 낮추며, 경부하로 갈수록 효율을 떨어뜨리게 된다. 철도 차량과 같은 고압, 대용량의 시스템에서 이러한 문제들은 더욱 두드러 진다. 본 논문에서는 내외측 소자간의 차단전압 불균형의 문제를 없애며, 무부하에서 전부하까지 모든 부하 영역에서 영전압 스위칭 동작을 할 수 있는 새로운 3-레벨 ZVS PWM DC/DC 컨버터를 제시한다. 제안한 회로의 동작 특성과 타당성을 시뮬레이션 및 실험 결과를 통하여 입증한다.

  • PDF

마이크로 프로세서를 이용한 축전지의 병렬 운전 부하분담률 개선에 관한 연구 (A Study on the Improved Load Sharing rate in Paralleled Operated Lead Acid Battery by Using Microprocessor)

  • 이정민
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2000년도 전력전자학술대회 논문집
    • /
    • pp.493-497
    • /
    • 2000
  • A battery is the device that transforms the chemical energy into the direct-current electrical energy without a mechanical process. Unit cells are connected in series to obtain the required voltage while being connected in parallel to organize capacity for load current. Because the voltage drop down in one set of battery is faster than in two one it may result in the low efficiency of power converter with the voltage drop and cause the system shutdown. However when the system being shutdown. However when the system being driven in parallel a circular-current can be generated,. It is shown that as a result the new batteries are heated by over-charge and over-discharge and the over charge current increases rust of the positive grid and consequently shortens the lifetime of the new batteries. The difference between the new batteries and old ones is the amount of internal resistance. In this paper we can detect the unbalance current using the microprocessor and achieve the balance current by adjusting resistance of each set, The internal resistance of each set becomes constant and the current of charge and discharge comes to be balanced by inserting the external resistance into the system and calculating the change of internal resistance.

  • PDF

온라인 무정전전원장치의 병렬운전 제어기술 (Parallel Operation Control Technique of On-line UPS System)

  • 조준석;강병희;고재석;최규하;김진홍;정석언
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.501-505
    • /
    • 2001
  • The parallel operation system of UPS is used to increase reliability of power source at critical load. But parallel UPS system has a few defects, impedance is different from each other and circulating current occurs between UPSs, due to line impedance and parameter variation, though controlled by the same synchronization signal. According to such characteristic of parallel UPS, balanced load-sharing control is the most important technique in parallel UPS operation. In this paper, a novel power deviation compensation algorithm is proposed. it is composed of voltage controller to compensate power deviation that be calculated by using active and reactive current deviation between inverters on synchronous d-q reference frame.

  • PDF

납 축전지의 병렬운전시 부하분담률 개선 (Improved Load Sharing Rate in Paralleled Operated Lead Acid Batteries)

  • 반한식;최규하
    • 전력전자학회논문지
    • /
    • 제6권1호
    • /
    • pp.34-42
    • /
    • 2001
  • 전지는 화학에너지를 기계적인 처리과정 없이 전기에너지로 직접 전환하는 장치이다. 부하전압과 부하전류의 용량에 따라 단위전지를 직.병렬 연결하여 사용하게 되며, 전지의 병렬운전은 단독운전 보다 전압강하를 더 천천히 발생시키므로 전압강하에 민감한 전력변환장치들의 효율에 밀접한 관계를 가지고 있다. 병렬운전의 필요성과 장점 때문에 대부분의 축전지를 사용하는 시스템은 병렬운전을 하고 있고, 반면에 선.구 축전지 사이에서 순환 전류가 흐르고, 자가방전이 일어나는 단점 또한 가지고 있다. 신 축전지에서 충.방전 전류가 과다하게 흐르는 불평형 현상과 이로 인해 축전지의 수명단축을 일으키게된다. 본 논문에서는 마이크로 프로세서를 사용하여 선.구 축전지 사이의 볼평형 전류를 검출하고 외부저항을 첨가시켜 내부저항의 차이에 대한 감소효과를 얻어 불평형 전류를 보상하였다. 이를 실험을 통해 구현하였다.

  • PDF