• 제목/요약/키워드: Balance of the Bipolar

검색결과 12건 처리시간 0.025초

Effects of Trunk Control Rehabilitation Robot Training on Dynamic Balance, Lower Extremity Strength, Gait Ability and Pain in Bipolar Hemiarthroplasty

  • Yang, HyunKwan;Lim, Hyoungwon
    • The Journal of Korean Physical Therapy
    • /
    • 제31권2호
    • /
    • pp.94-102
    • /
    • 2019
  • Purpose: This study examined the effects of trunk control rehabilitation robot training (TCRRT) on the dynamic balance, lower extremity strength, gait ability and pain for bipolar hemiarthroplasty. Methods: Hemiarthroplasty (n=28) patients participated in this study. The subjects were randomized into two groups: trunk control rehabilitation robot training group and control group. Results: The TCRRT group showed significantly more improvement in the MFRT, MMT, 10MWT, TUG, and VAS compared to that before intervention (p<0.05). In addition, all tests were significantly greater in the experimental group than in the control group. Conclusion: These results suggest that TCRRT is feasible and effective for improving the dynamic balance, lower extremity strength, gait ability, and pain efficacy after bipolar hemiarthroplasty.

Two-fluid model of the tangential plasmapause

  • Seough, Jung-Joon;Kim, Khan-Hyuk;Yoon, Peter H.;Lee, Dong-Hun
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 2010년도 한국우주과학회보 제19권1호
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • A bipolar magnetic field perturbation in the meridional plane was observed when the Polar spacecraft crossed the plasmapause near the midnight, which was identified by a clear jump in density and temperature, from the plasmasheet to the plasmasphere. The bipolar variation shows a negative-then-positive polarity. To examine the bipolar magnetic field perturbation at the plasmapause, we assume one-dimensional model with physical quantities varying along a direction normal to the plasmapause and employ two-fluid approach for the tangential plasmapause. That is, the magnetic fields on both sides are parallel. Considering Ampere's law and pressure balance relation, we have a perturbed magnetic field, which is consistent with the observation at the plasmapause.

  • PDF

양극성 DC 배전 시스템 적용을 위한 결합 인덕터 기반의 전압 밸런싱 이중 출력 CLL 공진형 컨버터 (Coupled Inductor Based Voltage Balancing in Dual-Output CLL Resonant Converter for Bipolar DC Distribution System)

  • 이승훈;김정훈;차헌녕
    • 전력전자학회논문지
    • /
    • 제27권4호
    • /
    • pp.348-355
    • /
    • 2022
  • A bipolar DC distribution system suffers from an imbalance in voltages when asymmetric loads are connected at the outputs. Dedicated voltage balancers are required to address the imbalance in bipolar voltage levels. However, additional components eventually increase the cost and decrease the efficiency and power density of the system. Therefore, to deal with the imbalance in output voltages without adding any extra components, this study presents a coupled inductor-based voltage balancing technique with a dual-output CLL resonant converter. The proposed coupled inductor does not require extra magnetic components to balance the output voltages because it is the result of resonant inductors of the CLL tank circuit. It can also avoid complex control schemes applied to voltage balancing. Moreover, with the proposed coupled inductor, the CLL converter acquires good features including zero voltage and zero current switching. Detailed analysis of the proposed coupled inductor is presented with different load conditions. A 3.6-kW hardware prototype was built and tested to validate the performance of the proposed coupled inductor-based voltage balancing technique.

바이폴라막 전기투석에 의한 유기산 회수에 관한 모델링 (Modeling for the Recovery of Organic Acid by Bipolar Membrane Electrodialysis)

  • 김상헌;이병철
    • Korean Chemical Engineering Research
    • /
    • 제44권5호
    • /
    • pp.476-482
    • /
    • 2006
  • 본 연구에서는 유기산염으로부터 유기산으로의 변환을 2실 배열 공정의 바이폴라막 전기투석을 이용하여 행하였다. 유기산으로 아세트산과 젖산을 사용하였으며, 유기산의 농도, 가성소다의 농도 그리고 pH 값들을 전류밀도에 따라 측정하였다. 그 결과 유기산염은 효과적으로 유기산으로 전환되었을 뿐만 아니라, 잔여 $Na^+$ 이온을 수산화나트륨의 형태로 회수할 수 있었다. 실험 결과를 바탕으로 이온 평형을 고려하여 수학적인 모델을 확립하였다. 시간에 따른 유기산의 농도, 가성소다의 농도 그리고 pH 값의 모델식은 실험 데이터와 잘 일치하였다.

Hierarchical Control Scheme for Three-Port Multidirectional DC-DC Converters in Bipolar DC Microgrids

  • Ahmadi, Taha;Hamzeh, Mohsen;Rokrok, Esmaeel
    • Journal of Power Electronics
    • /
    • 제18권5호
    • /
    • pp.1595-1607
    • /
    • 2018
  • In this paper, a hierarchical control strategy is introduced to control a new three-port multidirectional DC-DC converter for integrating an energy storage system (ESS) to a bipolar DC microgrid (BPDCMG). The proposed converter provides a voltage-balancing function for the BPDCMG and adjusts the states of charge (SoC) of the ESS. Previous studies tend to balance the voltage of the BPDCMG buses with active sources or by transferring power from one bus to another. Furthermore, the batteries available in BPDCMGs were charged equally by both buses. However, this power sharing method does not guarantee efficient operation of the whole system. In order to achieve a higher efficiency and lower energy losses, a triple-layer hierarchical control strategy, including a primary droop controller, a secondary voltage restoration controller and a tertiary optimization controller are proposed. Thanks to the multi-functional operation of the proposed converter, its conversion stages are reduced. Furthermore, the efficiency and weight of the system are both improved. Therefore, this converter has a significant capability to be used in portable BPDCMGs such as electric DC ships. The converter modes are analyzed and small-signal models of the converter are extracted. Comprehensive simulation studies are carried out and a BPDCMG laboratory setup is implemented in order to validate the effectiveness of the proposed converter and its hierarchical control strategy. Simulation and experimental results show that using the proposed converter mitigates voltage imbalances. As a result, the system efficiency is improved by using the hierarchical optimal power flow control.

국내 연료전지 분야 연구동향 분석: 전극, 전해질, 분리판, 스택, 시스템, BOP, 진단분석 분야 (Review of Research Trend in Fuel Cell: Analysis on Fuel-Cell-Related Technologies in Electrode, Electrolyte, Separator Plate, Stack, System, Balance of Plant, and Diagnosis Areas)

  • 이영덕;김재엽;유동진;주현철;김한상
    • 한국수소및신에너지학회논문집
    • /
    • 제31권6호
    • /
    • pp.530-545
    • /
    • 2020
  • This paper reviews and summarizes the fuel-cell-related studies those have been recently published in major Korean Citation Index journals, aiming at analyzing the research trend in fuel cell technologies. Six major journals are selected for the literature survey; 57 papers are chosen for the detailed analysis through a screening examination on the total 1,040 papers published during between 2018 and 2020. Papers are classified into six technical categories, such as i) electrode, ii) electrolyte, iii) bipolar plate and stack, iv) fuel cell system, v) balance of plant, and vi) diagnosis-related studies, and summarized by the experts in the relevant area. Through this paper, we provide a comprehensive review on the recent trends and progress in fuel-cell-related research work in Korea.

Understanding the Unfolded Protein Response (UPR) Pathway: Insights into Neuropsychiatric Disorders and Therapeutic Potentials

  • Pitna Kim
    • Biomolecules & Therapeutics
    • /
    • 제32권2호
    • /
    • pp.183-191
    • /
    • 2024
  • The Unfolded Protein Response (UPR) serves as a critical cellular mechanism dedicated to maintaining protein homeostasis, primarily within the endoplasmic reticulum (ER). This pathway diligently responds to a variety of intracellular indicators of ER stress with the objective of reinstating balance by diminishing the accumulation of unfolded proteins, amplifying the ER's folding capacity, and eliminating slow-folding proteins. Prolonged ER stress and UPR irregularities have been linked to a range of neuropsychiatric disorders, including major depressive disorder, bipolar disorder, and schizophrenia. This review offers a comprehensive overview of the UPR pathway, delineating its activation mechanisms and its role in the pathophysiology of neuropsychiatric disorders. It highlights the intricate interplay within the UPR and its profound influence on brain function, synaptic perturbations, and neural developmental processes. Additionally, it explores evolving therapeutic strategies targeting the UPR within the context of these disorders, underscoring the necessity for precision and further research to effective treatments. The research findings presented in this work underscore the promising potential of UPR-focused therapeutic approaches to address the complex landscape of neuropsychiatric disorders, giving rise to optimism for improving outcomes for individuals facing these complex conditions.

LVDC 배전을 위한 75kW급 양방향 컨버터 연구 (A Study on 75kW Bidirectional Converter for LVDC Distribution)

  • 이정용;김호성;조진태;김주용;조영훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2018년도 전력전자학술대회
    • /
    • pp.432-433
    • /
    • 2018
  • A new DC-DC converter circuit for LVDC(Low Voltage Direct-Current) distribution is proposed. DC-DC converter consists of two stage which are voltage balancer and converter stage. The balancing circuit adjust balance input voltage of converter circuit and compensate for unbalanced loads and short circuits. The converter circuit control the bipolar output voltage ${\pm}750V$. Simulation is carried out for this DC-DC converter system.

  • PDF

Study on Validity of 1-D Spherical Model on Aqua-plasma Power Estimation With Electrode Structure

  • 윤성영;장윤창;김곤호
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.74-74
    • /
    • 2010
  • The aqua-plasma is the non-thermal plasma in electrical conductive electrolyte by generates the vapor film layer on the immersed metal electrode surface. This plasma can generate the hydroxyl radical by dissociate the water molecule with the plasma electron. To develop the plasma discharge device for high efficiency in the hydroxyl radical generation, proper model for estimation of plasma power is necessary. In this work, the 1-D spherical model was developed, considering temperature dependence material constants. The relation between the plasma power and hydroxyl generation was also studied by the comparison between the optical emission intensity from the hydroxyl radical using monochromator and estimated plasma power. First, the thickness of vapor layer thickness was estimated using the Navier-Stokes fluid equation in order to calculate the discharge E-field inside vapor layer. Using the E-field magnitude and power balance on the plasma generation, it was possible to estimate the plasma power. The plasma power was assumed to uniformly fill the vapor layer and the temperature of vapor layer was fixed in the boiling temperature of electrolyte, 375K. In the experiment, the aqua-plasma was discharged in the saline by applied the voltage on the bipolar electrode. The range of applied voltage was 234 to 280V-rms in the frequency of 380 kHz. Two type electrodes were produced with two ${\Phi}0.2$ tungsten. The plasma power was estimated from the V-I signal from the two high voltage probes and current probe. The estimated plasma power agreed with the profile of emission intensity when the plasma discharged between the metal electrode and vapor layer surface. However, when the plasma discharged between the metal electrodes, the increasing rate of emission intensity was lower than the increase of plasma power. It implies that the surface reaction is more sufficient rather than the volume reaction in the radical generation, due to the high density of water molecule in the liquid.

  • PDF

Exploring Thermoelectric Transport Properties and Band Parameters of n-Type Bi2-xSbxTe3 Compounds Using the Single Parabolic Band Model

  • Linh Ba Vu;Soo-ho Jung;Jinhee Bae;Jong Min Park;Kyung Tae Kim;Injoon Son;Seungki Jo
    • 한국분말재료학회지
    • /
    • 제31권2호
    • /
    • pp.119-125
    • /
    • 2024
  • The n-type Bi2-xSbxTe3 compounds have been of great interest due to its potential to achieve a high thermoelectric performance, comparable to that of p-type Bi2-xSbxTe3. However, a comprehensive understanding on the thermoelectric properties remains lacking. Here, we investigate the thermoelectric transport properties and band characteristics of n-type Bi2-xSbxTe3 (x = 0.1 - 1.1) based on experimental and theoretical considerations. We find that the higher power factor at lower Sb content results from the optimized balance between the density of state effective mass and nondegenerate mobility. Additionally, a higher carrier concentration at lower x suppresses bipolar conduction, thereby reducing thermal conductivity at elevated temperatures. Consequently, the highest zT of ~ 0.5 is observed at 450 K for x = 0.1 and, according to the single parabolic band model, it could be further improved by ~70 % through carrier concentration tuning.