• Title/Summary/Keyword: Bacteriological quality

Search Result 66, Processing Time 0.018 seconds

Bacteriological Quality of Sea Water at Swimming Beaches in Busan Area (부산시내 해수욕장해수의 세균학적 수질에 관한 연구)

  • KIM Yong-Kwan;CHANG Dong-Suck
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.3
    • /
    • pp.148-157
    • /
    • 1981
  • This experiment was carried out to evaluate the sanitary quality of sea water at popular swimming beaches such as Haeundae, Kwanganri and Songjeong which are located in the suburbs of Busan Korea. One hundred and seventy five sea water samples were collected from the 25 stations during the both summer seasons in 1979 and in 1980. The sampling stations were established in the above 3 swimming beaches and the estuary of Suyeong river (See Fig.1.). To evaluate the sanitary quality, coliform group, fecal coliform, viable cell count and Vibrio parahaemolyticus were observed. The median value of coliform group MPN of the samples ranged 2,300 to 6,500/100m1 in Kwanganri, 670 to 910/100m1 in Haeundae and 430 to 460/100m1 in Songjeong swimming beach. Geometric mean of fecal coliform MPN was 3,200/100m1 in Kwanganri, 500/100m1 in Haeundae and 360/100m1 in Songjeong swimming beach. Composition of coliform was $23\%$ Escheri-chia coli group, $20\%$ Citrobacter freundii group, $41\%$ Klebsiella aerogenes group and $16\%$others. The density of Vibrio parahaemolyticus in Kwanganri was much higher than those of in other beaches by 5 to 6 times. Plate count of the samples in the estuary of Suyeong river was varied from 300 to $8.5\times10^6/ml$ during the study period. No remarkable difference was observed in bacterial density by tide in swimming beaches but the bacterial density of sea water at ebb tide was obviously higher than those of the samples at flood tide in the estuary of Suyeong river.

  • PDF

Monitoring on Microbiological Contamination of Packed Ice Creams from Manufacturing Factories in Korea (국내 제조공장에서 생산된 아이스크림류의 미생물학적 오염실태 조사)

  • Heo, Eun-Jeong;Ko, Eun-Kyung;Kim, Young-Jo;Seo, Kun-Ho;Park, Hyun-Jung;Wee, Sung-Hwan;Moon, Jin San
    • Journal of Food Hygiene and Safety
    • /
    • v.29 no.3
    • /
    • pp.202-206
    • /
    • 2014
  • In this study, the bacteriological survey was examined on ice creams at manufacturing factories in Korea during the summer season of 2011. The nineteen selected among 166 samples by preliminary test were collected from 11 different manufacturing factories in four major manufacturers in May 2011. Samples from ice milk, ice creams, sherbets, and non milk fat ice creams were tested for the total aerobic bacteria, coliform bacteria, and five food borne pathogens, respectively. The results showed that the coliforms including E. coli O157:H7, Salmonella spp., Staphylococcus aureus, Clostridium perfringens, and Listeria monocytogenes were not detected on all the ice creams. The total aerobic bacteria of the packed samples examined ranged between $2.5{\times}10^3$ and $5.5{\times}10^5cfu/g$. One ice cream, two sherbets, and four ice milk samples exceeded the acceptable limits of total aerobic bacteria according to the Korean standards for ice cream ($1.0{\times}10^5cfu/g$) and others ($5.0{\times}10^4cfu/g$). The levels of these microorganisms from ice creams were higher in three original equipment manufacturers than seven self-manufacturers. Three of ten ice creams (30.0%), three of six ice milks (50.0%), and one of two sherbets (50%) exceeded the acceptable limits of total aerobic bacteria, respectively. The personnel hygiene procedures with chocolate and vanilla chip addition from the manufacturing process were the main sources of the microbial contamination of stick-bar type ice creams when being produced in a factory. Improvement of the hazard analysis critical control points (HACCP) system should be introduced into the ice cream factory to improve the microbial quality of the ice cream products in Korea.

Chemical and Bacteriological Quality of Spring Waters in Pusan Area (부산시내 약수의 화학적 및 세균학적 수질에 관한 연구)

  • KIM Yong-Gwan;KOH Kwang-Bae
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.2
    • /
    • pp.169-175
    • /
    • 1986
  • This study was carried out to evaluate the water quality of spring waters in Pusan area (see Fig. 1). In this experiment, one hundred and forty water samples were collected at 20 stations from July to December 1985. Range and mean value of constituents of the samples were as follows ; pH 6.2-8.2, 7.07 ; water temperature $4.0-23.5^{\circ}C,\;15.9^{\circ}C$ ; electrical conductivity $0.228{\times}10^{2}-2.125{\times}10^2{\mu}{\mho}/cm,\;0.860{\times}10^2{\mu}{\mho}/cm$; chloride ion 3.28-19.3mg/l, 6.81mg/l ; nitrite-nitrogen ND-0.221 mg/l, 0.017mg/l ; nitrate-nitrogen ND-6.779mg/l, 0.877 mg/l ; phosphate-phosphorus ND-0.105mg/l, 0.021mg/l ; silicate-silicious 2.12-22.70mg/l, 9.04mg/l, respectively. Especially, electrical conductivity, chloride ion, nitrite-nitrogen, nitrate-nitrogen, and silicate-silicious of the station 11 (Millakdong) were higher than those of others as $1.815{\times}10^2{\mu}{\mho}/cm$, 13.5mg/l, 0.076mg/l, 4.772mg/l and 14.07mg/l. Range and geometric mean value of total coliform and fecal coliform MPN's of the samples were 0-1,500/100ml, 13-470/100ml and 0-460/100ml, 2-32/100ml. Composition of coliform was $26.37\%$ Escherichia coli group, $21.98\%$ Citrobacter freundii group, $37.36%$ Entrobacter aerogenes group and $14.29\%$ others.

  • PDF

Distribution and Characteristics of Heterotrophic Plate Count Bacteria in Water Samples from Drinking Water Dispensers (냉온수기에서 일반세균의 분포 및 분리한 세균의 특성)

  • Lee, Eun-Hwa;Koh, Ji-Yun;Kim, Jong-Seol
    • Korean Journal of Microbiology
    • /
    • v.44 no.3
    • /
    • pp.244-250
    • /
    • 2008
  • To evaluate bacteriological water quality, samples were taken from drinking water dispensers placed at S company (S-C) and U highschool (U-H) in Ulsan. The medians of heterotrophic plate counts (HPCs) were 53 CFU/ml for the 74 water samples of S-C and 80 CFU/ml for the 36 cold water samples of U-H, and 38% of the S-C and 42% of the U-H samples showed HPC bacterial concentrations higher than 100 CFU/ml. Coliform bacteria were detected from one sample of S-C. To determine the major source of bacterial contamination, water samples were taken daily for $6\sim8$ days from the bottled water containers as well as the faucets of an experimental water dispenser. While the average HPCs in the bottled water containers were 33 CFU/ml for the first and 132 CFU/ml for the 2nd analysis, the HPC concentration in the cold water samples was 1,022 CFU/ml for the 2nd analysis. These results suggest that the majority of bacteria detected in the cold water samples were originated from the biofilms on the surface of water passages within the water dispensers. There was no significant increase in HPC bacterial concentrations within the bottled water container after installation on the water dispenser. We could isolate and tentatively identify 3 genera 6 species of Gram-positive and 7 genera 7 species of Gram-negative bacteria from the plate count agar plates of U-H samples. Among the isolates, 72% were observed as Gram-positive, and Micrococcus spp. was the most abundant with 54% of the total, followed by Sphingomonas paucimobilis with 16%. It appears that most of the HPC bacteria detected in water dispensers originate from indoor airborne bacteria, which may play important roles in the formation of biofilms on the surface of water passages within the water dispensers.

Studies on Bacterial Contamination of Domestic Chicken Breeding Farm (국내 종계장에 있어서 미생물 오염에 관한 연구)

  • 김기석;이희수;김상희;박근식
    • Korean Journal of Poultry Science
    • /
    • v.18 no.3
    • /
    • pp.151-159
    • /
    • 1991
  • As a part of investigation on causes of drop in egg production in domestic chicken breeding farm, bacteriological contamination on air, feed, drinking water and artificial insemination instruments of randomly selected three farms was surveyed. Total bacterial population in the air was very high in all of the chicken houses tested and was not significantly different among these farms . However, total bacterial counts in the air of the problem house having egg drop problem and colibacillosis was higher than normal house within the problem farm. Bacterial population in the assorted feed was low before or after administration on the normal farm while it was much more increased after administration than before administration on the problem farm. Bacterial population of the drinking water in the source of water supply was very low and has no differences among farms tested. Also, bacterial population in the normal farm was not significantly different between source of water supply and after administration. However, population of total bacteria and coliform bacteria after administration was increased. Bacterial population was much higher in the artificial insemination instrument of problem farm than normal farm. However, this bacterial population in the problem farm was decreased to those of normal farm after these instruments were sanitized.

  • PDF

Chemical and Bacteriological Water Qualify of the Sonakdong River (서낙동강 강수의 화학적${\cdot}$세균학적 수질)

  • KIM Yong Gwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.19 no.4
    • /
    • pp.347-355
    • /
    • 1986
  • The Sonakdong river is very important water source not only for agricultural water of Kimhae field but also for fishery water. Recently the middle and lower areas of the river have the tendency to be heavily contaminated by domestic sewage and agricultural chemicals. Fifty six water samples were collected from 8 stations from July to December in 1985 for the experiment (Fig. 1). To evaluate the water quality, pH, water temperature, electrical conductivity, chloride ion, nutrients ($NO^{-}_{2}-N,\;NO^{-}_{3}-N,\;NH^{+}_{4}-N,\;PO^{3-}_{4}-P,\;SiO_2-Si$), total coliform, fecal coliform, and fecal streptococcus were determined. Range and mean value of the samples were as follows; pH $6.3{\sim}9.4$, 7.91; water temperature $6.1{\sim}34.8^{\circ}C,\;23.88^{\circ}C$; electrical conductivity (from St. A to G) $1.575{\times}10^2{\sim}30.50{\times}10^2{\mu}{\mho}/cm,\;6.57{\times}10^2{\mu}{\mho}/cm$; chloride ion $23.5{\sim}14,300mg/l$, 770.0mg/l; nitrite-nitrogen $0.007{\sim}0.110mg/l$, 0.053mg/l; nitrate-nitrogen $0.001{\sim}1.638mg/l$, 0.649 mg/l; ammonia-nitrogen $0.017{\sim}4.200mg/l$, 0.497mg/l; phosphate-phoshorus $0.011{\sim}0.281mg/l$, 0.086mg/l; and silicate-silicious $2.4{\sim}6.5mg/l$, 4.43mg/l. Electrical conductivity and chloride ion of the station F(Chomanpo) were $2.676{\times}10^2{\mu}{\Omega}cm$ and 123.99mg/l which were lower than those of others. Among the analyzed nutrients, silicate-silicious concentration was the highest through all the samples. The bacterial density of the samples ranged $36{\sim}110,000/100ml$ for total coliform, $15{\sim}46,000/100ml$ for fecal coliform and $3.6{\sim}15,000/100ml$ for fecal streptococcus. The range and the mean of the TC/FC ratio were $3.0{\sim}9.6$, 5.51 and those of the FC/FS ratio were $1.1{\sim}9.2$, 6.19, respectively. On the other hand, fecal coliform was not detected in about $78\%$ of the water samples examined. Composition of coliform was $52\%$ Escherichia coli group, $3\%$ Citrobacter freundii group, $13\%$ Enterobacter aerogenes group and $31\%$ others.

  • PDF