• Title/Summary/Keyword: Background Radioactivity

Search Result 105, Processing Time 0.027 seconds

Comparison of Recovery Coefficients for Correction of Reduced SUV by Partial Volume Effect and Organ Movements in PET/CT Images (PET/CT 영상의 부분체적효과와 장기의 움직임으로 인해 감소된 SUV의 보정을 위한 회복계수의 비교)

  • Kim, Youngjae;Park, Hoon-Hee;Lee, Joo-Young;So, Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.241-248
    • /
    • 2022
  • In this study, a recovery coefficient (RC) calculation was conducted that can correct the underestimation of the standardized uptake value (SUV) due to the partial volume effect (PVE) through phantom measurements and formulas. The experiment was conducted using a dynamic phantom capable of implement cranio-caudal movement at a respiratory rate of 15 times per minute along with the measured phantom experiment of the stopped state, and the RC of the moving state is calculated and compared. Ingenuity TF (Philips Healthcare, Netherland) was used as a positron emission tomography/computed tomography (PET/CT) device. PET-CT Phantom (Biodex Medical System, USA) was used as a phantom for measurement. A phantom image in a stationary state was acquired, and a moving phantom image was acquired using the AZ-733V Respiratory Phantom (Anzai Medical Co, Japan) capable of breathing movement in the cranio-caudal direction under the same acquisition parameters. For RC calculation, the sphere maximum radioactivity concentration and the background mean radioactivity concentration of the acquired images were measured, and the initially determined sphere and background radioactivity concentrations were calculated. The calculated RC was 0.08 to 0.72. The size of sphere smaller, it was confirmed that the RC reduced. And the RC in the moving state reduced than in the stationary state. As a result of this study, the change of the RC was confirmed according to the size of spheres and the phantom moving. Using the RC derived by implement movement of breathing with the respiratory phantom, it is possible to considering correction of underestimated SUV by the partial volume effect of PET images and the patient movements.

A Study of Determination of Minimum Detectable Activity at Measuring of Pu Isotopes in Environmental Samples (환경시료 중 Pu 측정에서 최소검출방사능 농도 산출에 대한 연구)

  • Lee, Myung-Ho;Cho, Young-Hyun;Choi, Gun-Sik;Lee, Chang-Woo;Shin, Hyun-Sang
    • Analytical Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.64-71
    • /
    • 2001
  • In this paper, the formula of lower limit of detection considering the measuring time of sample and background was derived using the basic concepts of lower limit of detection. Among parameters affecting the determination of MDA value, the MDA values were calculated with variation of amount of sample and measuring time of sample and background. The results of adequate division between the measuring time of sample and that of background studied in this research make it possible to evaluate confidence limits on the radio analytical results in the environmental sample.

  • PDF

Development of Self-Questionnaire for Internal Dose Assessment by Food Ingestion

  • JiEun Lee;Hyo Jin Kim;Yong-Uk Kye;Dong-Yeon Lee;Wol Soon Jo;Chang-Geun Lee;Jung-Ki Kim;Yeong-Rok Kang
    • Journal of Radiation Protection and Research
    • /
    • v.47 no.4
    • /
    • pp.204-213
    • /
    • 2022
  • Background: The accident at the Fukushima Daiichi nuclear power plant increased the level of anxiety related to the radioactive contamination of various foods sourced in Japan. Particularly, after the accident, the detection of artificial radionuclides in locally produced foods raised food safety concerns. In this study, the radioactivity concentrations and annual ingestions of 40K and 137Cs in food products commonly and frequently consumed by the general public were investigated, and the annual effective dose of each was evaluated. Materials and Methods: The 2016-2018 data from the Radiation Safety Management Report released by the Korea Nuclear Safety Technology Center was referenced for the evaluation of the amounts of 40K and 137Cs contained in food. Using the food-ingestion survey mentioned above as a reference, we selected 62 foods to include in our radioactivity concentration and dose assessment. We also developed a questionnaire and evaluated the responses from the subjects who answered the questionnaire. Results and Discussion: The radioactivity concentration of 137Cs was found to be close to or below the level of minimum detectable activity. Additionally, the annual ingestion of 62 foods was 294.77 kg/yr, the effective doses from 40K and 137Cs were 136.4 and 0.163 μSv/yr, respectively. Conclusion: Thus, the findings confirmed that the effective dose from 40K and 137Cs in food tends to be lower than the effective dose limit of 1 mSv/yr suggested by the International Commission on Radiological Protection (ICRP) Publication 60. The questionnaire developed in this study is expected to be useful for estimating the annual effective dose status of Korean adults who consume foods containing 40K and 137Cs.

Evaluation of Reasonable $^{18}F$-FDG Injected Dose for Maintaining the Image Quality in 3D WB PET/CT (PET/CT 검사에서 영상의 질을 유지하기 위한 적정한 $^{18}F$-FDG 투여량의 평가)

  • Moon, A-Reum;Lee, Hyuk;Kwak, In-Suk;Choi, Sung-Wook;Suk, Jae-Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.2
    • /
    • pp.36-40
    • /
    • 2011
  • Purpose: $^{18}F$-FDG injected dose to the patient is quite different between the recommended dose from manufacturer and the actual dose applied to each of hospitals. injection of inappropriate $^{18}F$-FDG dose may not only increase the exposed dose to patients but also reduce the image quality. we thus evaluated the proper $^{18}F$-FDG injected dose to decrease the exposed dose to patients considering the image quality. Materials And Methods: NEMA Nu2-1994 phantom was filled with $^{18}F$-FDG increasing hot cylinder radioactivity concentration to 1, 3, 5, 7, 9 MBq/kg based on the ratio of 4:1 between the hot cylinder and background activity. after completing the transmission scan using ct, emission scan was acquired in 3D mode for 2 minutes 30 seconds/bed. ROI was set up on hot cylinder and background radioactivity region. after measuring $SUV_{max}$ those regions, then analyzed SNR at the points. clinical experiment has been conducted the object of patients who have came to smc from november 2009 to august 2010, 97 patients without having a hepatic lesions were selected. ROI was set up in the liver and thigh area. after measuring $SUV_{max}$, the image quality was compared following the injected dose. Results: in phantom study, as the injected radioactivity concentration per unit mass was 1, 3, 5, 7, 9 MBq/kg, $SUV_{max}$ was 23.1, 24.1, 24.3, 22.8, 23.6 and SNR was shown 0.48, 0.54, 0.56, 0.55, 0.55. according to increment of the injected dose, $SUV_{max}$ and SNR was increased under 5 MBq/kg but they were decreased over 7 MBq/kg. in case of clinical experiment, as increased the injected radioactivity concentration per unit mass was 4.72, 5.34, 6.16, 7.41, 8.68 MBq/kg, $SUV_{max}$ was 2.68, 2.67, 2.26, 1.88, 1.95 and SNR was shown 0.52, 0.53, 0.46, 0.46, 0.44. if the injected dose exceeds 5 MBq/kg, showed a decrease pattern as phantom study. Conclusion: increasing $^{18}F$-FDG injected dose considered patient's body weight improve image quality within a certain range. if it exceeds the range, it can be reduced image quality due to random and scatter coincidences. this study indicates that the optimal injected dose was 5 MBq/kg per unit mass the injected radioactivity concentration in 3d wb pet/ct.

  • PDF

Gamma-ray Full Spectrum Analysis for Environmental Radioactivity by HPGe Detector

  • Jeong, Meeyoung;Lee, Kyeong Beom;Kim, Kyeong Ja;Lee, Min-Kie;Han, Ju-Bong
    • Journal of Astronomy and Space Sciences
    • /
    • v.31 no.4
    • /
    • pp.317-323
    • /
    • 2014
  • Odyssey, one of the NASA's Mars exploration program and SELENE (Kaguya), a Japanese lunar orbiting spacecraft have a payload of Gamma-Ray Spectrometer (GRS) for analyzing radioactive chemical elements of the atmosphere and the surface. In these days, gamma-ray spectroscopy with a High-Purity Germanium (HPGe) detector has been widely used for the activity measurements of natural radionuclides contained in the soil of the Earth. The energy spectra obtained by the HPGe detectors have been generally analyzed by means of the Window Analysis (WA) method. In this method, activity concentrations are determined by using the net counts of energy window around individual peaks. Meanwhile, an alternative method, the so-called Full Spectrum Analysis (FSA) method uses count numbers not only from full-absorption peaks but from the contributions of Compton scattering due to gamma-rays. Consequently, while it takes a substantial time to obtain a statistically significant result in the WA method, the FSA method requires a much shorter time to reach the same level of the statistical significance. This study shows the validation results of FSA method. We have compared the concentration of radioactivity of $^{40}K$, $^{232}Th$ and $^{238}U$ in the soil measured by the WA method and the FSA method, respectively. The gamma-ray spectrum of reference materials (RGU and RGTh, KCl) and soil samples were measured by the 120% HPGe detector with cosmic muon veto detector. According to the comparison result of activity concentrations between the FSA and the WA, we could conclude that FSA method is validated against the WA method. This study implies that the FSA method can be used in a harsh measurement environment, such as the gamma-ray measurement in the Moon, in which the level of statistical significance is usually required in a much shorter data acquisition time than the WA method.

Food Ingestion Standards for Nuclear Emergency Exposure Situations

  • Keum, Dong-Kwon;Jeong, Hyojoon;Jun, In;Lim, Kwang-Muk;Choi, Yong-Ho;Hwang, Won-Tae
    • Journal of Radiation Protection and Research
    • /
    • v.42 no.3
    • /
    • pp.166-175
    • /
    • 2017
  • Background: This study presents food ingestion standards for radioactivity that can be applied in nuclear emergency exposure situations, and discusses the validity of the current domestic standards. Materials and Methods: This study derived food ingestion standards for radiocesium and radioiodine using domestic food intake rates and intervention levels, which serve as a basis for determining the necessity of public protective actions, and then compared them with the existing guidelines. Operational intervention levels were also derived using domestic food intake rates, and were compared with those of the International Atomic Energy Agency. Results and Discussion: The derived activity concentrations for food ingestion standards of radiocesium for infants were higher than those in the Act on Physical Protection and Radiological Emergency (APPRE) for all food categories, while for adults, the derived activity concentrations for drinking water and milk appeared to be slightly lower. The derived activity concentrations for vegetables, fruits, and grains were greater than those in the guidelines of the APPRE, while the derived activity concentrations for meat and seafood were similar to those in the APPRE. The derived activity concentrations for radioiodine were greater than both domestic and global standards. The calculated operational intervention levels (OILs) based on domestic food intake rates were greater than the IAEA's default OIL6 values for most radionuclides, except for a few ${\alpha}$-radionuclides. Conclusion: The current domestic guidelines turned out to be conservative overall, compared to the present results that were calculated using domestic food intake rates. It is recommended that the domestic guidelines should be revised and complemented transparently through an in-depth review by stakeholders on a solid scientific basis.

Biodistribition of [$^{125}I$]-labeled biotinylated dendrimer derivatives for antibody pretargeting

  • Kim, Hyung-Sik;Han, Eui-Sik;Wong, Karen J.;Paik, Chang H.
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.99.3-100
    • /
    • 2003
  • It is desirable to improve the tumor targeting and blood clearance pharmacokinetics of radiolabeled monoclonal antibodies. To achieve this goal, several avidin-biotin (Bt) binding systems have been developed to decouple large molecular weight antibodies from small radiolabels, thereby achieving high tumor-to-background radioactivity ratios. We inserted a readily catabolizable linker, triglycine (TG), between 3-[/sup125/I]iodobenzoate and dendrimer (G3). We also neutralized the positive charges of G3 by acylation with tetrafluorophenyl glycolate, thereby blocking proximal tubular reabsorption of G3 mediated by charge attraction. (omitted)

  • PDF

$^{99m}Tc-Labeling$ of Monoclonal Antibody to Carcinoembryonic Antigen and Biodistribution (항 암태아성항원에 대한 단세포군항체의 $^{99m}Tc$ 표지법개발 및 생체분포)

  • Moon, Dae-Hyuk;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Chung, Hong-Keun;Park, Jae-Gahb
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.2
    • /
    • pp.380-391
    • /
    • 1992
  • This study was designed to evaluate a direct method of $^{99m}Tc$ labeling using $\beta-mercaptoethanol$ as a reducing agent, and to investigate whether $^{99m}Tc$ labeled specific monoclonal antibody against carcinoembryonic antigen (CEA-92) can be used for the scintigraphic localization of human colon cancer xenograft. Purified CEA-92 IgG was fragmented into F $(ab')_2$ and then labeled with $^{99m}Tc$ by transchelation method using glucarate as a chelator. Labeling efficiency, immunological reactivity and in vitro stability of $^{99m}Tc$ CEA-92 F $(ab')_2$ were measured and then injected intravenously into nude mice bearing human colon cancer (SNU-C4). Scintigrams were obtained at 24 hour after injection. Then nude mice were sacrificed and the radioactivity was measured Labeling efficiency of injected $^{99m}Tc$ CEA-92 F $(ab')_2$, immunoreative fraction and in vitro stability at 24 hour of injected $^{99m}Tc$ CEA-92 F $(ab')_2$ was 45.2%, 32.8% and 57.4%, respectively. At 24 hour after injection, % ID/g in kidney (46.77) showed high uptake, but %ID/g in tumor (1.65) was significantly higher than spleen (0.69), muscle (0.16), intestine (0.45), stomach (0.75), heart (0.48) and blood (0.45). There was no significant difference between tumor and liver (1.81). Tumor contrast as quantitated by tumor to blood ratio of $^{99m}Tc$ CEA-92 F $(ab')_2$ was increased significantly (p<0.005) until 24 hours (3.70), and there was no statistical differece from tumor to blood ratio of I-131 CEA-92 F $(ab')_2$. The scintigram demonstrated localization of radioactivity over transplanted tumor, but significant background radioactivity was also noted over kidney and abdomen. It is concluded that CEA-92 F $(ab')_2$ can be labeled with $^{99m}Tc$ by a direct transchelation method using $\beta-mercaptoethanol$ as a reducing agent and $^{99m}Tc$ labeled CEA-92 F $(ab')_2$ can be used for the scintigraphic localization of human colon cancer xenograft in nude mice model.

  • PDF

Development of the Measurement Method of Extremely Low Level Activity with Imaging Plate (Imaging Plate를 이용한 극저준위 방사능 측정에 관한 연구)

  • Kwak, Ji-Yeon;Lee, K.B.;Lee, Jong-Man;Park, Tae-Soon;Oh, Pil-Jae;Lee, Min-Kie;Seo, Ji-Suk;Hwang, Han-Yull
    • Journal of Radiation Protection and Research
    • /
    • v.29 no.4
    • /
    • pp.231-236
    • /
    • 2004
  • An imaging plate(IP) detector, a two-dimensional digital radiation detector that can acquire image of radioactivity distribution in a sample, has been applied in many fields; for industrial radiography, medical diagnosis, X-ray diffraction test, etc. In this study, the possibility of IP detector to be used lot measuring radioactivity of sample is explored using its high sensitivity, higher spatial resolution, wider dynamic range and screen uniformity for several kinds radiations. First, the IP detector is applied to measure the surface uniformity for area source. Surface uniformity is measured rapidly and nondestructively by measuring the radioactivity distribution of common standard area source$(^{241}Am)$. Next, the IP is employed to study the possibility of measuring an extremely low-level activity of environmental sample. For this study the screen uniformity, shield effect of background radiation, linear dynamic range and fading effect of the IP detector is investigated. The potato, banana, radish and carrot samples are chosen to measure ultra low-level activity of $^{40}K$ isotope. The efficiency calibration of IP detector is carried out using the standard source.

Distribution of Radioactivities of $^{226,228}Ra,\;^{137}Cs$ and $^{40}K$ in Soil in Busan Area (부산지역 토양의 $^{226,228}Ra,\;^{137}Cs$$^{40}K$ 방사능 분포)

  • Seo, Bum-Kyoung;Sung, Jung-Wook;Kim, Hyun-Duck;Lee, Dae-Won
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.4
    • /
    • pp.441-445
    • /
    • 2001
  • In this work we investigated distribution of the natural and artificial radioactive nuclides and level of the regional background in soil in Busan. For 45 points, the environmental radioactivity concentration of Busan surface soil is $14.38{\sim}57.03\;(mean\;:\;33.95)\;Bq{\cdot}kg^{-1}$ for $^{226}Ra,\;2.41{\sim}86.58\;(mean\;:\;51.08)\;Bq{\cdot}kg^{-1}$ for $^{228}Ra,\;223.64{\sim}1332.30\;(mean\;668.51)\;Bq{\cdot}kg^{-1}$ for $^{40}K$ and $<0.33{\sim}33.37\;(mean:13.74) Bq{\cdot}kg^{-1}$ for $^{137}Cs$. Also, in order to investigate vertical distribution for radioactivity, we examined radioactive concentration with mountain height. But there was no correlation between radiaoactivity distribution and mountain height. The $^{226}Ra/^{228}Ra$ and $^{226}Ra/^{40}K$ concentration ratios were $0.68{\pm}19 %$ and $0.06{\pm}34%$, respectively.

  • PDF