• Title/Summary/Keyword: Back pressure test

Search Result 218, Processing Time 0.025 seconds

A Study on the Development of an Automatic Multi-Nozzle Injection Molding Machine (Multi-Nozzle Injection Molding Automatic Machine 개발에 관한 연구)

  • Lee, Jong-Hyung;Kim, Jung-Hwan;Yi, Chang-Heon;Kim, Yun-Gon;Lim, Chun-Kyoo;Lee, Chun-Kon;Kwon, Yung-Shin
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.10 no.2
    • /
    • pp.123-128
    • /
    • 2007
  • The demand for the precision rubber products has been rapidly increasing with the recent growth of industries. And the requirement for the productivity and the quality calls out for the injection molding machines with the precision machining ability as well as the high productivity. Especially modern automobile industry is in urgent need of developing injection molding machines for the high quality rubber products with high productivity. And the inability of the domestic companies to meet the standards causes importing foreign machines and as a result spending good amount of dollars. It is extremely important to develop competitive machines and strengthen the infrastructure of the related industries. In this paper the functions and the structure of a automatic multi-nozzle injection molding machine has been studied to set up a proper test system for the precision rate and the reliability of the machines, which can help build the machines to meet the request of the industry.

  • PDF

The Development of LPP Combustor for ESPR

  • Kinoshita, Yasuhiro;Oda, Takeo;Kobayashi, Masayoshi;Ninomiya, Hiroyuki;Kimura, Hideo;Hayashi, Shigeru;Yamada, Hideship;Shimodaira, Kazuo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.453-459
    • /
    • 2004
  • An axially staged combustor equipped with an LPP combustion system and CMC liner walls has been investigated for stable combustion and low NOx emissions for the ESPR project. Several fuel injectors were designed and manufactured for the LPP burner, and single sector combustor tests were conducted to evaluate fundamental combustion characteristics such as emissions, instabilities, auto-ignition, and flash back at typical operating conditions from idle to Mn 2.2 cruise. The latest test results showed that the LPP burner had a good potential for the low NOx target. It was also found that the NOx emission level was greatly affected by a distortion in the air flow velocity field upstream of the LPP burner due to the diffuser and fuel feed arm. The CMC material was investigated to apply for the high temperature and low NOx combustor. Annular combustor liner walls were manufactured with the CMC material, and they have been tested at low pressure conditions to evaluate the soundness of the material and the mounting and seal system. This paper reports the latest research activities on the LPP combustion system and CMC liner walls for the ESPR project.

  • PDF

Modeling of Force Components Acting on Quay Walls During Earthquakes (지진시 중력식 안벽에 작용하는 하중성분의 모델링)

  • 김성렬;권오순;김명모
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.2
    • /
    • pp.107-121
    • /
    • 2003
  • When the seismic stability of quay walls is analyzed, the magnitudes of force components acting on quay walls during earthquakes and the phase relations among these force components must be properly evaluated. In general, force components include inertia force of the quay wall, lateral earth force, and water force. The magnitude and the phase relation of each force component vary according to the magnitude of the excess pore pressures developed in backfill soils of the quay wall. The dynamic thrust mobilized at the contact surface between the backfill soil and the wall develops as a result of the interactions among these force components. We propose a simple model to evaluate the magnitude and phase variation of the dynamic thrust on the back of the wall in terms of the excess pore pressure. The proposed model can predict the dynamic thrust by summing the magnitudes of farce components calculated from design equations for seismic pressures on the wall. The proposed model was verified by comparing its results with the results from a series of shaking table tests.

An Experimental Study on the Ballistic Accuracy by Air Guide Grooves (공기안내홈이 탄도 정확도에 미치는 실험적 연구)

  • Kim, Junkyu;Kim, Hyungse;Lee, Moonhwan
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.2
    • /
    • pp.195-201
    • /
    • 2016
  • An experimental study has been found the air guide grooves for reducing drag. When a bullet is fired and move in the air, the drag is generated. The vortex which is one of the types of drag hinders the movement of the bullet. To solve this phenomenon, cut a negative grooves that we are called the air guiding grooves at the back of bullet. The grooves bullet has identified that the drag compared to conventional ammunition(KM80 and K193) is reduced to 4.480 and 4.054 : 10 % through a Finite Analysis Program($Ansys^{TM}$). Even pressure center was retreating 0.72 % compared to a Bullet(KM80 and K193). Effect obtained with these results is the accuracy of the grooves bullet in a shooting test was improved by over 32 %(KM80: 2.86, air guide grooves : 1.94) compared to conventional ammunition(KM80 and K193). In addition, muzzle velocity is increased 73 m/s. This is expected to be extended the velocity and effective range of bullet. Also, the velocity of the grooves bullet is increased when moving in the air while the velocity of the bullet(KM80 and K193) is reduced. The gas ejected from the muzzle to be balanced and stable flight of the Bullet. Given these effects, we can reckon the air guide grooves have positive influence.

Indicator of Diagnosing Fatigue by Analyzing Questionnaire Data (설문지를 이용한 피로 진단 지표 연구)

  • Yoon, Tak-Hyun;Park, Soo-Jung;Choi, Na-Rae;Jin, Ming;Joo, Jong-Cheon;Kwon, Young-Mi
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.17 no.3
    • /
    • pp.179-188
    • /
    • 2013
  • Objectives This study was designed to development the diagnosis indicators for the fatigue group without disease using analysis of questionnaire data. Methods The subjects were divided into three groups, the fatigue group with disease, the fatigue group without disease, non-fatigue group without disease. Thirteen kinds of questionnaire (Fatigue visual analogue scale, Fatigue severity scale, Pain visual analogue scale, Short-form McGill pain questionnaire score, Headache impact Test-6, Neck disability index, Oswestry low back pain disability questionnaire score, Blood stasis assessment scale, Physical activities questionnaire score, Beck depression inventory, Anger expression inventory score, Mood disability scale, Job stress scale) were carried out for the subjects. Results The results of this study are ; 1) The weight, the systolic and diastolic blood pressure were different among three groups. 2) Among nine questionnaires related to the physical or life conditions, the averages of eight questionnaires were not same one another. 3) Among four questionnaires related to the mental condition or autonomic nervous system, the averages of Beck depression inventory were not same one another. Conclusion The fatigue group without disease can be diagnosed through using the both the questionnaires related to the physical or life condition and the those related to the mental condition or autonomic nervous system.

Age-related Differences in Ankle-joint Proprioception and Postural Balance in Women: Proprioception of Force Versus Position

  • Kim, Seo-hyun;Yi, Chung-hwi;Lim, Jin-seok;Lim, One-bin
    • Physical Therapy Korea
    • /
    • v.29 no.2
    • /
    • pp.124-130
    • /
    • 2022
  • Background: During postural control, older adults are more dependent on proprioception than are young adults. Ankle proprioception, which plays an important role in maintaining postural balance, decreases with age. Published studies are insufficient to establish a significant age difference in postural sway resulting from the known age-related decrease in ankle proprioception and do not examine various detailed test conditions. Objects: The present study aimed to compare ankle proprioception between older and younger groups along dimensions of position vs. force proprioception and dorsiflexion vs. plantarflexion. The present study also aimed to compare postural sway between young and older women during quiet standing under two sensory conditions. Methods: We recruited seven young women aged 21-24 and seven older women aged 60-63. Ankle proprioception was assessed as the accuracy of the joint position sense (JPS) and the force sense (FS). Postural sway was assessed using center-of-pressure measurements recorded during quiet standing under two sensory positions: eyes open and eyes closed with head tilted back. Results: Older women had lower JPS in dorsiflexion and lower FS in plantarflexion than did younger women. We found no significant age differences in JPS in plantarflexion or in FS in dorsiflexion. We observed a main effect of group on postural sway in two sway parameters out of three. We observed significant differences in JPS with dorsiflexion, and in FS with plantarflexion. Conclusion: Proprioception for ankle plantar flexor decreased more significantly with aging than did that for ankle dorsiflexor, accounting for the impaired postural balance observed in older women.

Column cleaning, regeneration and storage of silica-based columns (실리카 기반 컬럼의 세척, 재생 및 보관 가이드)

  • Matt James;Mark Fever
    • FOCUS: LIFE SCIENCE
    • /
    • no.1
    • /
    • pp.1.1-1.4
    • /
    • 2024
  • This article provides comprehensive guidance on the maintenance, cleaning, regeneration, and storage of silica-based HPLC (High-Performance Liquid Chromatography) columns. The general considerations emphasize the importance of using in-line filters and guard cartridges to protect columns from blockage and irreversible sample adsorption. While these measures help, contamination by strongly adsorbed sample components can still occur over time, leading to an increase in back pressure, loss of efficiency, and other issues. To maximize column lifetime, especially with UHPLC (Ultra-High Performance Liquid Chromatography) columns, it is advisable to use ultra-pure solvents, freshly prepared aqueous mobile phases, and to filter all samples, standards, and mobile phases. Additionally, an in-line filter system and sample clean-up on dirty samples are recommended. However, in cases of irreversible compound adsorption or column voiding, regeneration may not be possible. The document also provides specific recommendations for column cleaning procedures, including the flushing procedures for various types of columns such as reversed phase, unbonded silica, bonded normal phase, anion exchange, cation exchange, and size exclusion columns for proteins. The flushing procedures involve using specific solvents in a series to clean and regenerate the columns. It is emphasized that the flow rate during flushing should not exceed the specified limit for the particular column, and the last solvent used should be compatible with the mobile phase. Furthermore, the article outlines the storage conditions for silica based HPLC columns, highlighting the impact of storage conditions on the column's lifetime. It is recommended to flush all buffers, salts, and ion-pairing reagents from the column before storage. The storage solvent should ideally match the one used in the initial column test chromatogram provided by the manufacturer, and column end plugs should be fitted to prevent solvent evaporation and drying out of the packing bed.

  • PDF

Comparison of removal efficiency of diesel particulate filter with different measurement methods in a high-speed marine diesel engine (선박용 고속 디젤엔진에 적용한 디젤미립자 필터의 측정방법에 따른 입자상물질 저감효율 비교 연구)

  • Lee, Ik-Sung;Ko, Dong-Kyun;Moon, Gun-Feel;Nam, Youn-Woo;Kim, Shin-Han;Oh, Young-Taig
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.41 no.4
    • /
    • pp.362-367
    • /
    • 2017
  • This study was conducted to compare the particulate removal efficiency of the developed diesel particulate filter using various measurement methods in a high-speed marine diesel engine. A four-stroke mechanical marine diesel engine is used for the test, which has a maximum output of 403 kW and is coupled to an AC dynamometer to control engine speed and load. The test was conducted based on four steady-state engine operating conditions of E3 engine test cycle for the measurement of PM and soot removal efficiency using partial dilution method considered as gravimetric method and filter smoke number method as light absorption method, respectively. As a result of the removal efficiency measurement according to the application of diesel particulate filter, particulate matter was reduced from 76% to 91% and the soot was reduced by more than 90% while meeting the permissible engine back pressure. From these results, the applicability of diesel particulate filter adopted in high-speed marine diesel engines could be confirmed. In addition, based on the result that the particulate removal efficiency varies with different measurement methods, the necessity of unification of these methods could be identified.

Effects of Laminariae Thallus Extracts on Body Weight and Lipid Metabolism in High Fat Diet Rats (곤포(昆布)추출물이 고지방 식이에 의한 체중변화와 체내 지질대사에 미치는 영향)

  • Jeong Ji-Cheon;Nam Won-Gi;Shin Hyeon-Cheol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.19 no.5
    • /
    • pp.1296-1302
    • /
    • 2005
  • Laminariae Thallus has been known to be effective for the treatment of obesity. Te show the effectiveness of Laminariae Thallus in a more scientific way, Laminariae Thallus extract was prepared and evaluated in high fat diet rats by measuring the changes of body weight and lipid metabolism as described briefly below. 200 g of crushed Laminariae Thallus was extracted with methyl alcohol. The extract was evaporated under reduced pressure to give 14.4g. For 10 weeks, control group rat were ingested high fat diet, while the test group rat were fed with a fat diet pius Laminariae Thallus extract. Normal group was fed with normal diet. 150 mg of Laminariae Thallus extract per 1 kg of body weight was added to the diet in a test group rats. Control group rats on a high fat diet gained weight significantly, whereas the test group rats on a high fat diet plus Laminariae Thallus extract gained weight less. Significant increase of liver weight caused in a high fat diet was also inhibited by the Laminariae Thallus extract treatment. Total lipid, triglyceride, phospholipid and total cholesterol levels of serum in the high fat diet rats were remarkably increased, whereas their levels on a high fat diet plus Laminariae Thallus extract were less increased. While serum HDL-cholesterol levels was remarkably decreased in a high fat diet, its level was less decreased in a high fat diet plus Laminariae Thallus extract. Furthermore, we observed that the activities of hepatic acetyl-CoA carboxylase and fatty acid synthetase increased in a high fat diet, while their activities in a high fat diet plus Laminariae Thallus extract were getting back nearly to the normal levels of normal diet rats. These result showed that the obesity caused by a high fat diet was effectively inhibited by a Laminariae Thallus extract. Our results also showed that the abnormal lipid metabolism caused by a high fat diet was effectively cured by adding Laminariae Thallus extract.

Study of Factors for development of Advanced Media filter for Ballast water Treatment (밸러스트 수 처리용 메디아 필터 개발을 위한 여과특성에 관한 연구)

  • Park, Seon-Jeong;Lim, Jae-Dong;Kim, Dong-Geun;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.32 no.6
    • /
    • pp.499-503
    • /
    • 2008
  • As the conference result of MEPC in IMO, development of ballast water management system corresponding to newly established ballast water management standard (D2 regulation) of shipping is being made an active progress over the whole world. The ballast water management system should treat particular material of more than $10{\mu}m$ in high capacity of more than 500t per hour in the event of filtration process. Also, it is very difficult to develop a practical management system since a limited element which a narrow space of the ship should be designed in the minimal volume is assumed. Therefore, the study promoted a study on the next generation auto back wash media filter to overcome such a limited element. Also, the study performed pressure and flux measurement test followed by thickness of each filter medium for filtration by each size to grasp a relation between absorption and pressure at the time of vacuum filtration and mechanical analysis and turbidity change observation of filtered water after vacuum filtration.