• Title/Summary/Keyword: B_1$

Search Result 50,570, Processing Time 0.095 seconds

Grain Yield Potential of a Low-Tillering Large Panicle Type in Rice (벼 소얼 수중형 초형의 수량성)

  • Kim, Je-Kyu;B.S., Vergara
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.4
    • /
    • pp.361-371
    • /
    • 1992
  • For the increase of grain yield potential in rice, a low-tillering large panicled type has been suggested as an ideotype. A low-tillering plant type may have different yield potential and needs different cultural practices from that used in a high-tillering type for the maximum yield. This study was conducted to evaluate the grain yield performances of a low-tillering large panicled rice and high-tillering small panicled rice at different plant spacings, nitrogen(N) levels and seedling numbers per hill. A low-tillering large panicled genotype, IR25588 was compared with a high-tillering small panicled IR58. The grain yield of IR25588 was significantly higher than that of IR58 under a narrow spacing with high N level. The maximum yields of IR58 and IR25588 were reached at about 35,000 and 40,000 spikelets per m$^2$, respectively. The increased grain yield in IR25588 was mainly due to the increase in spikelet number per unit area which is the most precise indicator of grain yield in rice. The optimum spacing for the maximum yield was denser for IR25588 than that for IR58 under high N level. The intra-hill competition of the low-tillering type was lower than that of the high-tillering type. The higher dry matter production and bigger leaf area and culm weight were the main factors for increased grain yield in a low-tillering panicle weight type. Based on the results, the yield potential of a low-tillering panicle weight type was higher than that of a high-tillering panicle number type, especially under a close spacing with high N level.

  • PDF

Establishment of an Optimal Washing Condition of a High Temperature Steaming System for the Production of High Quality Pork (고품질 돈육 생산을 위한 고온증기세척수의 최적 조건)

  • Yang, H.S.;Jeong, J.Y.;Moon, S.H.;Park, G.B.;Joo, Seon-Tea
    • Journal of Animal Science and Technology
    • /
    • v.49 no.1
    • /
    • pp.121-128
    • /
    • 2007
  • The objective of this study was to determine the efficacy of different water temperatures and time of spray-washing on the removal of bacteria contamination from surface of pork carcass and to obtain better meat quality with high temperature stream between 60 to 90℃ for the time ranged from 10 to 60 sec. Results showed that total plate counts were significantly decreased with increasing steam temperature(P<0.05). Similar results were found with the spray time(P<0.05). The lightness(CIE L*) value was significantly increased in both loin and ham cuts over 80℃(P<0.05). Ultimate pH of muscle and water-holding capacity were decreased with increasing steam temperature(P<0.05). There was a significant difference in solubility of sarcoplasmic protein between 70℃ and 80℃ of the steam treatments with higher value at 70℃(P<0.05). Again, longer than 30 sec spray at 70℃ steam, the lightness value of pork was significantly increased(P<0.05), while pH and water-holding capacity of muscle were significantly decreased(P<0.05). Therefore, a desirable pork quality would be achieved with spray-steam washing at 70℃ for 20 sec on pork carcass.

Development of Algorithm in Analysis of Single Trait Animal Model for Genetic Evaluation of Hanwoo (단형질 개체모형을 이용한 한우 육종가 추정프로그램 개발)

  • Koo, Yangmo;Kim, Jungil;Song, Chieun;Lee, Kihwan;Shin, Jaeyoung;Jang, Hyungi;Choi, Taejeong;Kim, Sidong;Park, Byoungho;Cho, Kwanghyun;Lee, Seungsoo;Choy, Yunho;Kim, Byeongwoo;Lee, Junggyu;Song, Hoon
    • Journal of Animal Science and Technology
    • /
    • v.55 no.5
    • /
    • pp.359-365
    • /
    • 2013
  • Estimate breeding value can be used as single trait animal model was developed directly using the Fortran language program. The program is based on data computed by using the indirect method repeatedly. The program develops a common algorithm and imprves efficiency. Algorithm efficiency was compared between the two programs. Estimated using the solution is easy to farm and brand the service, pedigree data base was associated with the development of an improved system. The existing program that uses the single trait animal model and the comparative analysis of efficiency is weak because the estimation of the solution and the conventional algorithm programmed through regular formulation involve many repetition; therefore, the newly developed algorithm was conducted to improve speed by reducing the repetition. Single trait animal model was used to analyze Gauss-Seidel iteration method, and the aforesaid two algorithms were compared thorough the mixed model equation which is used the most commonly in estimating the current breeding value by applying the procedures such as the preparation of information necessary for modelling, removal of duplicative data, verifying the parent information of based population in the pedigree data, and assigning sequential numbers, etc. The existing conventional algorithm is the method for reading and recording the data by utilizing the successive repetitive sentences, while new algorithm is the method for directly generating the left hand side for estimation based on effect. Two programs were developed to ensure the accurate evaluation. BLUPF90 and MTDFREML were compared using the estimated solution. In relation to the pearson and spearman correlation, the estimated breeding value correlation coefficients were highest among all traits over 99.5%. Depending on the breeding value of the high correlation in Model I and Model II, accurate evaluation can be found. The number of iteration to convergence was 2,568 in Model I and 1,038 in Model II. The speed of solving was 256.008 seconds in Model I and 235.729 seconds in Model II. Model II had a speed of approximately 10% more than Model I. Therefore, it is considered to be much more effective to analyze large data through the improved algorithm than the existing method. If the corresponding program is systemized and utilized for the consulting of farm and industrial services, it would make contribution to the early selection of individual, shorten the generation, and cultivation of superior groups, and help develop the Hanwoo industry further through the improvement of breeding value based enhancement, ultimately paving the way for the country to evolve into an advanced livestock country.

Case Report of Radiotherapy to a Breast Cancer Patient with a Pacemaker (인공심장박동기가 이식된 유방암환자의 방사선 치료에 대한 사례 보고)

  • Chae, Seung-Hoon;Park, Jang-Pil;Lee, Yang-Hoon;Yoo, Suk-Hyun;Seong, Won-Mo;Kim, Kyu-Bo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.197-203
    • /
    • 2012
  • Purpose: In this study, we considerate our radiation therapy process for the breast cancer patient implanted a pacemaker applying the machine movement surgery, shielding, beam selection. Materials and Methods: We perform radiation therapy to a 54 years old, breast cancer patient implanted a pacemaker. The patient underwent a surgery to move the position of a pacemaker to right side breast after consultation with cardiology department. Prescribed dose was 5,040 cGy and daily dose 180 cGy for 28 fractions. The 10 MV photon energy, field size 0/$9.5{\times}20$ cm, half beam and opposing portal irradiation are used. To find out appropriate thickness of shielding board, we carried out an experiment using a solid water phantom ($30{\times}30{\times}7$ cm), a Farmer-type chamber (TN30013, PTW, Germany) and a shielding board (Pb $28{\times}27{\times}0.1$ cm). We calculated expected absorbed dose to te pacemaker with absorb ratio and shielding ratio. In the PTP system (Eclipse, Varian, USA), we figured out how much radiation would be absorbed to the machine with and without shielding. First day of the radiation therapy, we measured head scatter to the pacemaker with MOSFET Dose Verification System (TN-RD-70-W, Medical Canada Ltd., Canada). Results: In the phantom measurement, we found out appropriate thickness was 2 mm of shielding board. In the RTP, when using 2 mm shielding the pacemaker will be absorbed 11.5~38.2 cGy and DVH is 77.3 cGy. In the first day of the therapy, 4.3 cGy was measured so 120.4 cGy was calculated during total therapy. The patient was free from any side effects, and the machine also normally functioned. Conclusion: As the report of association which have public confidence became superannuated, there is lack of data about new machine. We believe that radiation therapy to thiese kind of patients could be done successfully with co-operation, patient-suitable planning, accurate QA, frequent in-vivo dosimetry and monitoring.

  • PDF

Clinical Effects of Oseltamivir in Children with Influenza in Busan, in the First Half of 2004 (2004년 상반기에 부산 지역 소아에서 유행한 독감에서 Oseltamivir의 치료 효과)

  • Park, Soo Kyoung;Choi, So Young;Kim, Sung Mi;Kim, Gil Heun;Jung, Jin Hwa;Choi, Im Jung;Cho, Kyung Soon
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.9
    • /
    • pp.976-985
    • /
    • 2005
  • Purpose : Although influenza is one of the most important causes of acute respiratory tract infections in children, effective antiviral therapies are not common and there are only a few clinical studies on treatment of influenza in children. We evaluated the efficacy of oseltamivir in the treatment of naturally aquired influenza in children during the first half of 2004 in Busan. Methods : From January 2004 to June 2004, throat swabs and nasal washes were performed and cultured for the isolation of influenza virus and tested by rapid antigen detection test(QuickVue influenza test) in children with suspected influenza infections. The children who responded positively to the QuickVue influenza test, we divided into two groups : an oseltamivir treatment group and a control group. We compared their clinical symptoms(including fever duration) and diagnosis. The medical records of patients with influenza virus infection were reviewed retrospectively. Results : A total of 621 individuals were suspected of influenza infection. Influenza viruses were isolated in 79(17.2 percent) out of 621 patients examined. QuickVue influenza tests were positive in 181 cases. The treatment group(83 individuals) received oseltamivir twice daily for 5 days, and the control group(99 individuals) were administered only symptom relief medicine. There was no differences between the two groups in clinical diagnosis and symptoms. Oseltamivir treatment reduced the fever duration and other respiratory symptoms. There were no adverse events associated with oseltamivir treatment. Conclusion : Our data suggest that oral oseltamivir treatment reduces the fever duration and other respiratory symptoms of acute influenza without side effects in children.

Inhibitory Substance on the Snake Venoms Produced by Penicillium sp. (사독의 조해물질에 관한 연구)

  • Seu, Jung-Hwn;Yi, Dong-Heui
    • Microbiology and Biotechnology Letters
    • /
    • v.7 no.2
    • /
    • pp.75-89
    • /
    • 1979
  • One strain of Penicillium sp. (175-66-B), isolated from soil, was able to produce a substance that has a strong inibition activity against the Agkistrodon and Trimeresurus venoms. In this experiment, the chemical and biological properties of the sample were investigated. As an inhibitory substance, it was effective to the proteinase, hemorrhagic and lethal factors of Agkistrodon and Trimeresurus venoms, and also effective to several fractions of the proteinases and hemorrhagic factors of Agkistrodon halys blomhoffi venom. Moreover, in the addition of prednisotone, it was more effective for the cure of the mouse envenomated with the venom amount of two fold of MLD$_{100}$. This substance was very stable to the acid, alkali and heat. Its melting point was high enough to sublime at 222$^{\circ}C$ without any decomposition. This sample was easily dissolved only in hot water, but not in several organic solvents except for a little dissolution in elate. It did not have the chelating activity. It had very strong specificity to the snake venoms. but its activity was depressed by the addition of zinc or cupric salts. This sample had no acute toxicity to the mouse. Its chemical formula was $C_{16}$ $H_{12}$$N_2$ $O_{10}$ with the molecular weight of about 392. It has two epoxy groups and four carboxyl radicals, but amino, nitrite and nitrate radicals, unsaturated bonds and aromatic ring were not detected. Theuchemical configuration of this sample was suggested to be;

  • PDF

Prediction of Dietary Protein-Energy Balance by Milk Urea Nitrogen and Protein Contents in Dairy Cow (젖소의 우유 중 단백질과 요소태질소 측정에 의한 사료의 에너지와 단백질 균형 상태 예측)

  • Moon, J.S.;Joo, Y.S.;Kang, H.M.;Jang, G.C.;Kim, J.M.;Lee, B.K.;Park, Y.H.;Son, C.H.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.5
    • /
    • pp.573-584
    • /
    • 2002
  • Milk urea nitrogen (MUN) and Milk protein (MP) are being used as indicators of the protein-energy balance and for actual farm feeding practices. The purpose of this study was to investigate the MUN and MP concentrations of individual cows and bulk tank milk to evaluate the dietary protein-energy balance from lactating Holstein cows. Mean MUN and MP concentrations in the milk samples obtained from 132,636 cows of 4,856 herd during Jan. 1999 to Dec. 2001 were 16.2 5.2mg/dl and 3.30 0.35%, respectively. The highest values were found during summer and lowest valued during winter in MUN. But, the average contents of MP were the highest during winter and the lowest during summer. In order to evaluate protein-energy balance for feeding, we set the level of recommended MP range of 2.90${\sim}$3.29% in early lactation considering a negative energy balance. The recommended level of MP in mid-lactation and late lactation were set as 3.10${\sim}$3.49%, and 3.30${\sim}$3.69%, respectively. Recommended MUN range of 12${\sim}$18 mg/dl was determined through the whole lactation period. Individual cows milk were analyzed by the 9 types based on this levels of MP and MUN in this study. Among the total cows investigated, 26.8%, 25.8%, and 22.2% have shown the recommended criteria of MP and MUN values, respectively. Also, of total herds surveyed, 11.6% had MUN values lower than 12.0 mg/dl and 32.9% had values higher than 18.0 mg/dl and 44.5% of total herd have not met with the recommended criteria of MP values in bulk tank milk. In case of MP, out of the total herd surveyed, 26.0% had MP values lower than 3.10% and 24.0% had values higher than 3.30% and 50.0% had MP values outside the recommended interval (3.1${\sim}$3.3%). This study has indicates that many dairy farms are under improper feeding management practice of the dietary protein-energy balance.

Estimation of Terminal Sire Effect on Swine Growth and Meat Quality Traits (돼지 성장 및 육질 형질에 영향하는 종료웅돈의 효과)

  • Kim, H.S.;Kim, B.W.;Kim, H.Y.;Iim, H.T.;Yang, H.S.;Lee, J.I.;Joo, Y.K.;Do, C.H.;Joo, S.T.;Jeon, J.T.;Lee, J.G.
    • Journal of Animal Science and Technology
    • /
    • v.49 no.2
    • /
    • pp.161-170
    • /
    • 2007
  • A submerged biofilm sequencing batch reactor (SBSBR) process, which liquor was internally circulated through sandfilter, was designed, and performances in swine wastewater treatment was evaluated under a condition of no external carbon source addition. Denitrification of NOx-N with loading rate in vertical and slope type of sandfilter was 19% and 3.8%, respectively, showing approximately 5 times difference, and so vertical type sandfilter was chosen for the combination with SBSBR. When the process was operated under 15 days HRT, 105L/hr.m3 of internal circulation rate and 54g/m3.d of NH4-N loading rate, treatment efficiencies of STOC, NH4-N and TN (as NH4-N plus NOx-N) was 75%, 97% and 85%, respectively. By conducting internal circulation through sandfilter, removal performances of TN were enhanced by 14%, and the elevation of nitrogen removal was mainly attributed to occurrence of denitrification in sandfilter. Also, approximately 57% of phosphorus was removed with the conduction of internal circulation through sandfilter, meanwhile phosphorus concentration in final effluent rather increased when the internal circulation was not performed. Therefore, It was quite sure that the continuous internal circulation of liquor through sandfilter could contribute to enhancement of biological nutrient removal. Under 60g/m3.d of NH4-N loading rate, the NH4-N level in final effluent was relatively low and constant(below 20mg/L) and over 80% of nitrogen removal was maintained in spite of loading rate increase up to 100g/m3.d. However, the treatment efficiency of nitrogen was deteriorated with further increase of loading rate. Based on this result, an optimum loading rate of nitrogen for the process would be 100g/m3.d.

Effectiveness of the Respiratory Gating System for Stereotectic Radiosurgery of Lung Cancer (폐암 환자의 정위적 방사선 수술 시 Respiratory Gating System의 유용성에 대한 연구)

  • Song Heung-Kwon;Kwon Kyung-Tae;Park Cheol-Su;Yang Oh-Nam;Kim Min-Su;Kim Jeong-Man
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.125-131
    • /
    • 2005
  • Purpose : For stereotactic radiosurgery (SRS) of a tumor in the region whose movement due to respiration is significant, like Lung lower lobe, the gated therapy, which delivers radiation dose to the selected respiratory phases when tumor motion is small, was performed using the Respiratory gating system and its clinical effectiveness was evaluated. Materials and Methods : For two SRS patients with a tumor in Lung lower lobe, a marker block (infrared reflector) was attached on the abdomen. While patient' respiratory cycle was monitored with Real-time Position Management (RPM, Varian, USA), 4D CT was performed (10 phases per a cycle). Phases in which tumor motion did not change rapidly were decided as treatment phases. The treatment volume was contoured on the CT images for selected treatment phases using maximum intensity projection (MIP) method. In order to verify setup reproducibility and positional variation, 4D CT was repeated. Results : Gross tumor volume (GTV) showed maximum movement in superior-inferior direction. For patient #1, motion of GTV was reduced to 2.6 mm in treatment phases ($30{\sim}60%$), while that was 9.4 mm in full phases ($0{\sim}90%$) and for patient #2, it was reduced to 2.3 mm in treatment phases ($30{\sim}70%$), while it was 11.7 mm in full phases ($0{\sim}90%$). When comparing two sets of CT images, setup errors in all the directions were within 3 mm. Conclusion : Since tumor motion was reduced less than 5 mm, the Respiratory gating system for SRS of Lung lower lobe is useful.

  • PDF

Implementation of Water Bolus in Patient with Large Tissue Defect (조직결손이 큰 환자에서 물 볼루스의 적용에 관한 고찰)

  • Park, Hyo-Kuk;Lee, Sang-Kyu;Yoon, Jong-Won;Cho, Jeong-Hee;Kim, Dong-Wook;Kim, Joo-Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.18 no.2
    • /
    • pp.105-112
    • /
    • 2006
  • Purpose: To demonstrate that water bolus in the patient surface can decrease the dose inhomogeneity by patient surface large tissue defect when the surface is in an electron-beam field. And We tried to find a easy way to water control. Methods and Materials: To demonstrate the use of water bolus in the irregular surface clinically, the case of a patient with myxofibrosarcoma of the chest wall who was treated with electrons. We obtained dose distribution using missing tissue option of PINACLE 6.2b (ADAC, USA). We fabricate a Mev-green for water bolus in patient with defect of tissue. Then put the water bolus which is vinyl packed water into the designed Mev-green. We peformed CT scan with CT-simulator. Three-dimensional (3D) dose distributions with and without water bolus in the large irregular chest wall were calculated for a representative patient. Resulting dose distributions and dose-volume histograms of water bolus were compared with missing tissue option and non bolus plans. We fabricate a new water control device. Results: Controlled Water bolus markedly decrease the dose heterogeneity, and minimizes normal tissue exposure caused by the surface irregularities of the chest wall mass. In the test case, The non bolus plan has a maximum target dose of 132%. After applying water bolus, the maximum target dose has been reduced substantially to 110.4%. The maximum target dose was reduced by 21.6% using this technique. Conclusion: The results showed that controlled water bolus could significantly improve the dose homogeneity in the PTV for patients treated with electron therapy using water control device. This technique may reduce the incidence of normal organ complications that occur after electron-beam therapy in irregular surface. And our new device shows handiness of water control.

  • PDF