• Title/Summary/Keyword: BTS test

Search Result 31, Processing Time 0.024 seconds

Characterization of Ultra Low-k SiOC(H) Film Deposited by Plasma-Enhanced Chemical Vapor Deposition (PECVD)

  • Kim, Sang-Yong
    • Transactions on Electrical and Electronic Materials
    • /
    • v.13 no.2
    • /
    • pp.69-72
    • /
    • 2012
  • In this study, deposition of low-dielectric constant SiOC(H) films by conventional plasma-enhanced chemical vapor deposition (PECVD) were investigated through various characterization techniques. The results show that, with an increase in the plasma power density, the relative dielectric constant (k) of the deposited films decreases whereas the refractive index increases. This is mainly due to the incorporation of organic molecules with $CH_3$ group into the Si-O-Si cage structure. It is as confirmed by FT-IR measurements in which the absorption peak at 1,129 $cm^{-1}$ corresponding to Si-O-Si cage structure increases with power plasma density. Electrical characterization reveals that even after fast thermal annealing process, the leakage current density of the deposited films is in the order of $10^{-11}$ A/cm at 1.5 MV/cm. The reliability of the SiOC(H) film is also further characterized by using BTS test.

A Study on the Effect of Plasma Deuterium Treatment on Reliability of Poly-Silicon Thin Film Transistors (중수소 프라즈마 처리가 다결정 실리콘 TFT의 안정성에 미치는 영향에 관한 연구)

  • Sohn Song Ho;Bae S. C.;Kim Donghwan
    • Korean Journal of Materials Research
    • /
    • v.14 no.7
    • /
    • pp.516-521
    • /
    • 2004
  • We applied a deuterium plasma treatment to the surface of polycrystalline silicon films using PECVD and observed the change with AFM, XRD, ET-IR, and SIMS measurement. A bias temperature stressing (BTS) test was carried out to evaluate the reliability of the thin-film transistors (TFT). TFTs with channel lengths as small as 2 ${\mu}m$ were electrically stressed fer up to 1000 sec at room temperature. From the parameter variation such as s-factor, leakage current and on/off ratio, we suggest that the deuterium plasma treatment suppress the hot carrier effect and improve the stability of TFTs.

Characterization of low-k dielectric SiOCH film deposited by PECVD for interlayer dielectric (PEDCVD로 증착된 ILD용 저유전 상수 SiOCH 필름의 특성)

  • Choi, Yong-Ho;Kim, Jee-Gyun;Lee, Heon-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.11a
    • /
    • pp.144-147
    • /
    • 2003
  • Cu+ ions drift diffusion in formal oxide film and SiOCH film for interlayer dielectric is evaluated. The diffusion is investigated by measuring shift in the flatband voltage of capacitance/voltage measurements on Cu gate capacitors after bias temperature stressing. At a field of 0.2MV/cm and temperature $200^{\circ}C,\;300^{\circ}C,\;400^{\circ}C,\;500^{\circ}C$ for 10min, 30min, 60min. The Cu+ ions drift rate of $SiOCH(k=2.85{\pm}0.03)$ film is considerable lower than termal oxide. As a result of the experiment, SiOCH film is higher than Thermal oxide film for Cu+ drift diffusion resistance. The important conclusion is that SiOCH film will solve a causing reliability problems aganist Cu+ drift diffuion in dielectric materials.

  • PDF

Stability enhancement of armorphous znic oxide thin film transistors fabricated by pulsed laser deposition with DBD (PLD-DBD 공정으로 제작된 비정질 Zn 산화물 박막트랜지스터의 안정성 향상)

  • Chun, Yoon-Soo;Chong, Eu-Gene;Jo, Kyoung-Chol;Kim, Seung-Han;Jung, Da-Woon;Lee, Sang-Yeol
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.391-391
    • /
    • 2010
  • The stability enhancement of Znic oxide thin film transistor deposited by PLD-DBD has been reported here using the bias temperature stress test. Znic oxide (ZnO) thin films were deposited on $SiO_2$/Si (100) by pulsed laser deposition method with and without dielectric barrier discharge (DBD) method. The DBD is the efficient method to adopt the nitrogen ions into the thin films. The TFT characteristics of ZnO TFTs with and without Nirogen (N) doping show similar results with $I_{on/off}$ of $10^5{\sim}10^6$. However. the bias temperature stress (BTS) test of N-doped ZnO TFT with DBD shows higher stability than that of ZnO TFT.

  • PDF

Assessing the long-term durability and degradation of rocks under freezing-thawing cycles

  • Seyed Zanyar Seyed Mousavi;Mohammad Rezaei
    • Geomechanics and Engineering
    • /
    • v.34 no.1
    • /
    • pp.51-67
    • /
    • 2023
  • In this research, the degradation rate of physical properties of the Angouran pit bedrock (calc-schist) is first investigated under the specific numbers of freeze-thaw (F-T) cycles. Then, the durability of calc-schist specimens against the F-T cycle number (N) is examined considering the mechanical parameters, and using the decay function and half-time techniques. For this purpose, point load strength (IS(50)), second durability index (Id2), Brazilian tensile strength (BTS), and compressive (VP) and shear (VS) wave velocities of calc-schist specimens are measured after 0, 7, 15, 40, and 75 N. For comparing the degradation rate of mechanical properties of available rock types on the Angouran mine walls, these tests are also carried out on the limestone and amphibolite schist specimens beside the calc-schist. According to test results, the exponential regression models are developed between the mechanical parameters of rock specimen's and N variable. Also, the long-term durability of each rock type versus N is studied using the decay function and half-time techniques. Results indicated that the degradation rate differs for the above rock types in which amphibolite schist and calc-schist specimens have the highest and least resistance against the N, respectively. The obtained results from this study can play a key role in the optimal design of the mine's final walls.

New Trend Proposal in Optimization Techniques Application for Mobile Network, Analysis and Signal Processing

  • HAMROUNI, Chafaa
    • Journal of Multimedia Information System
    • /
    • v.7 no.3
    • /
    • pp.221-230
    • /
    • 2020
  • Used optimization techniques as solution for mobile network have been implemented as a reference systems for various applications against fading and signals perturbation, in addition each transition to 5th generation telecommunication standards require a deep studies in order to park an applied instantaneous process. The paper describes a preliminary planning and a careful preparation to update both subscriber radio access network as well as data transmission network this approach conducts to make network resource updates invisible for customers and with minimal costs for mobile operators basically in terms of delay. In addition, network operators transit to mobile networks, multimedia services efficient delivery are considered the challenging application and the most promising for mobile network operators today, this work conduct to optimize video consumption of mobile users which are exponentially increasing. The interference is a complex phenomenon in mobile radio telecommunication system, and a mobile phone can be a source of interference to another one. Actual advances in technology necessitate the need for the complicated software solution that can take several unexpected phenomena in consideration to rise to a level higher than ever. The capability needs today require the use of Drive test which is used to take the performance of network in the field by using a special software called TEMS investigation, it have been implemented as standalone systems for various applications. The paper focuses on considering as the best technical for optimization of mobile networks, analysis and processing of signal, a Drive Test is the method used to take the performance of network in the field by using a special software called TEMS investigation. Most used in the world, this software is reputed to detect and analyze many problems of mobile network between the mobile phone and the transmitter: BTS in case of GSM and Node B for UMTS. An example of that is interference in radio communication. It exists permanently and it degrades considerably the quality of received signal when it exceeds certain levels.

Capacitance Fuel Sensor for Commercial Vehicle Software Verification Through R-BENCH TOOL (R-BENCH TOOL을 이용한 상용차용 정전용량 방식의 연료 센서의 소프트웨어 검증 평가)

  • Kim, Sang Woo;Lee, Ju Hyoung;Son, Jung Hyun;Lee, Soo Ho;Lee, Duck Jin
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.1-8
    • /
    • 2014
  • Recently vehicle development trend changes from machinery vehicle to the electrical and electronic devices. As well the electrical and electronic devices commercial vehicles are increasing more than machinery system. The capacitance fuel sensor is a sensor that, by measuring the capacitance value of fuel level sensor MCU operating for the final voltage value of the signal output. That is increasing durability and fuel measurement accuracy more than conventional ceramic resistor type. For Sensor software verification R-BENCH TOOL generated test case automatically. We make the programmable Capacitor board for test. And it was confirmed that more than 98% of the high reliability of the software.

Effects of Different Concentrations of Escherichia coli and Days of Preservation on Boar Sperm Quality

  • Chung, Ki-Hwa;Kim, In-Cheul;Son, Jung-Ho
    • Reproductive and Developmental Biology
    • /
    • v.37 no.4
    • /
    • pp.213-217
    • /
    • 2013
  • The objective of this study was to investigate the effect of bacterial contamination on elapsed time after preservation on boar semen. Known numbers of Escherichia coli (E. coli) were inoculated to freshly ejaculated semen and sperm parameters such as viability, motility, agglutination, acrosome integrity and hypo-osmotic swelling test were performed during 7 days of liquid preservation. Semen samples were prepared using antibiotic free BTS extender and 4 different levels of E. coli were treated to semen with following concentrations; 3,000, 5,000, 7,000, 10,000 CFU/ml of sperms. Semen samples were preserved at $17^{\circ}C$ for 7 days in semen storage until analyzed. Aliquots were subjected to measure the sperm viability, motility and agglutination using computer assisted sperm analysis (CASA) system, acrosome integrity was performed using chlortetracycline (CTC) staining method and hypo-osmotic swelling test was performed using hypotonic solution from day 1 (day of semen collection) to 7. Detrimental effects on sperm motility and viability were observed 3 days after preservation at the level of 5,000 CFU/ml (p<0.05). Percentage of sperm abnormality was higher (p<0.05) in over 5,000 CFU/ml groups. Sperm agglutination rate was also significantly higher (p<0.05) in groups of 5,000 and 7,000 CFU/ml. The rate of acrosome reacted sperm was higher as preservation time goes in all the samples but the pattern was clearly higher among E. coli contaminated groups (p<0.05). The sperm membrane integrity in terms of hypo-osmotic test, E. coli affects little compared to other sperm parameters. The deleterious effects observed due to the bacterial contamination in semen suggest that importance of hygiene protocol to minimize the bacterial contamination during semen collection and processing.

Effects of Gym-ball Exercise in Standing Position on Muscle Strength, Balance, Gait and Fall Efficacy in Stroke Patients (선 자세에서 짐볼 운동이 뇌졸중 환자의 근력, 균형, 보행 및 낙상 효능감에 미치는 효과)

  • Lim, Yun-Jeong;Kang, Soon-Hee
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.10 no.1
    • /
    • pp.49-60
    • /
    • 2022
  • Purpose : The purpose of this study was to identify whether gym-ball exercise in standing position was an effective intervention for improving muscle strength, balance, gait, and fall efficacy in stroke patients. Methods : Twenty-four stroke patients were randomized into three groups: experimental group 1 (n=8), experimental group 2 (n=8), and control group (n=8). Experimental groups 1, 2 and the control group performed the gym-ball exercise in standing position, same exercise without a gym-ball, and general physical therapy for 4 weeks, five times a week in 30-minute sessions. Muscle strength, balance, gait, and fall efficacy were assessed using a handheld dynamometer, the Berg Balance Scale (BBS), the wearable BTS G-WALK® sensor, and the Korean version of the Falls Efficacy Scale (K-FES), before and after training, respectively. Comparisons within and between groups were analyzed using the Wilcoxon signed rank test, Kruskal Wallis H test, and Mann-Whitney U test. Bonferroni correction was performed when significant differences between groups were identified (p<.017, .05/3). Results : Regarding muscle strength, BBS score, cadence and FES-K were significantly improved after intervention in all three groups. The weight bearing rate, gait speed and step length in experimental group 1 and 2 were significantly improved after the intervention. The stride length in experimental group 1 were significantly improved after the intervention. Experimental group 1 had significantly improved BBS score and stride length after intervention than experimental group 2 and control group. Experimental group 1 and 2 improved muscle strength, weight bearing rate, and FES-K score more than the control group. Experimental group 1 showed significant improvement in cadence, gait speed, and step length after the intervention than control group. Conclusion : This study showed that exercise with gym-ball in standing position can be an effective intervention to improve balance and gait in stroke patients than the same exercise without gym-ball.

Use of a capacitance voltage technique to study copper drift diffusion in low-k polyimide (C-V Technique을 이용한 low-k polyimide로의 구리의 drift diffusion 연구)

  • Choi, Yong-Ho;Lee, Heon-Yong;Kim, Jee-Gyun;Kim, Jung-Woo;Kim, Yoo-Kyuong;Park, Jin-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.05c
    • /
    • pp.137-140
    • /
    • 2003
  • Cu+ ions drift diffusion in different dielectric materials is evaluated. The diffusion is investigated by measuring shift in the flatband voltage of capacitance/voltage measurements on Cu gate capacitors after bias temperature stressing. At a field of 1.lMV/cm and temperature $200^{\circ}C$, $250^{\circ}C$, $300^{\circ}C$ for 1H, 2H, 5H. The Cu+ ions drift rate of polyimide$(2.8{\leq}k{\leq}3.2)$ is considerably lower than thermal oxide. Also Cu+ drift rate of polyimide is similar to PECVD oxide. But, polyimide film is even more resistant to Cu drift diffusion and thermal effect than Thermal oxide, PECVD oxide: This results got a comparative reference. The important conclusion is that polyimide film is strongly dielectric material by thermal effect and Cu drift diffusion.

  • PDF