• Title/Summary/Keyword: BS8414

Search Result 2, Processing Time 0.02 seconds

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

The Study on Real Scale Fire Test of Building Exterior Wall Assemblies (건축물 외장재 수직확산 실대형 화재실험에 관한 연구)

  • Kweon, Oh-Sang;Yoo, Yong-Ho;Kim, Heung-Youl
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.295-300
    • /
    • 2011
  • 국내 건축물 외장재의 화재위험성 판단을 위한 기준 설정 및 건축물 외장재 수직확산 방지를 위하여 국내 외 실규모 화재실험을 비교 분석하였다. 현재 미국, 영국 등의 화재안전선진국들에서는 NFPA 285, BS 8414-1 등의 실대형 화재 실험을 통하여 외장재의 화재위험성을 판단하고 있다. 이에 본 연구에서는 국내 외 건축물 외장재의 수직화재확산 성능 평가 방법들의 비교 분석을 통하여 국내 실정에 맞는 실대형의 화재실험 방법을 결정하고자 하였다. 본 결과를 통해 건축물의 단위 공간에서 화재가 발생하여 화재의 성장이 플래시오버에 도달한 후 창문 등의 개구부를 통하여 화염이 출화되었을 때 이러한 화염에 의한 건축물 외장재의 수직화재 확산 성능 평가하는 건축물 외장재 수직확산 실대형 화재실험 장비를 개발하고자 하였다.

  • PDF