• Title/Summary/Keyword: BRIDGE 3.0

Search Result 518, Processing Time 0.027 seconds

Behavior Analysis of IPM Bridge and Rahmen Bridge (토압분리형 교량과 라멘교의 거동분석)

  • Shin, Keun-Sik;Han, Heui-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.4
    • /
    • pp.597-605
    • /
    • 2019
  • IPM bridge is an integral bridge that can be applied from span 30.0m up to 120.0m, the shape conditions of IPM bridge is also applicable to the rahmen bridge. In this study, to perform the structural analysis of Rahmen bridge and IPM Bridge, the researchers compared the distribution types such as load, moment, and displacement of those bridges. Structural analysis was carried out on four span models ranging from single span bridges to four spans of 120.0 m, based on span length of 30.0 m. Structural analysis was carried out on those bridge with span 30.0m up to 120.0m. The conclusions drawn from this study are as follows. 1) The bending moments were calculated to be large for the Rahmen bridge, and the horizontal displacements were estimated to be large for the IPM bridge. 2) Since the bending moments are derived by the span length rather than the extension of the bridge, the permissible bending moment for the span length should be considered in the design. 3) The pile bent of the IPM bridge did not exceed the plastic moment of the steel pipe pile at 120.0m span, but because the horizontal displacement in the shrinkage direction is close to 25mm, the design considerations are needed. 4) In the actual design, it is important to ensure stability against member forces, so review of the negative moment is most important.

Load Bearing Capacity Evaluation of Continuous IPC Girder Bridge. (IPC 거더 연속교의 실교량 내하력 평가 연구)

  • Han, Man-Yop;Hwang, Eu-Seung;Jin, Kyung-Seok;Kang, Sang-Hoon;Shin, Jae-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05a
    • /
    • pp.475-478
    • /
    • 2005
  • This study was performed to evaluate about load bearing capacity of continuos IPC Girder Bridge under and after Construction. This is Ichi-1 Bridge that is 2-40m span continuous bridge on a extension road through the Ichun and the Naesa. The result of static loading test to use a 25ton truck after construction, deflection ratio is 0.64 that is $35\%$ and average of response ratio is 0.48$\~$0.89 that is less than theoretical value. The result of dynamic loading test, the number of proper vibrations is 3.06Hz that is like theoretical value 3.61Hz, the modulus of impact is 0.235 that is bigger than specification 0.19. the load bearing capacity is minimum DB-40 that is so big value. In the result, continuos IPC Girder Bridge is safe in short period. we will evaluate long period behavior of continuos IPC Girder Bridge.

  • PDF

The Effects of Performing a One-legged Bridge with Hip Abduction and Unstable Surface on Trunk and Gluteal Muscle Activation in Healthy Adults

  • Bak, Jong-Woo;Cho, Min-Kwon;Chung, Yi-Jung
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.3
    • /
    • pp.205-211
    • /
    • 2016
  • Purpose: This study investigated the influence of muscle activity of the trunk and lower limb during a bridge exercise using a unstable surface and during one-legged bridge hip abduction in healthy adults. Methods: Nineteen healthy participated in this study (12 males and 7 females, aged $29.0{\pm}5.0$). The participants were instructed to perform the bridge exercises under six different conditions. Trunk and lower limb muscle activation, such as the erector spinae (ES), gluteus maximus (GM), external oblique (EO), and internal oblique (IO), was measured using surface electromyography. The six different bridge exercise conditions were conducted randomly. Data analysis was performed by using the mean scores after three trials of each condition. Results: On the ipsilateral side, muscle activity of the IO, EO, and ES during the hip abduction condition (Single-legged hip abduction bridge, Bridge with use of a ball and single-leg hip abduction, Bridge with use of a sling and single-leg hip abduction) was significantly higher than those during Unstable surface (Bridge with use of a ball, Bridge with use of a sling) and General bridging exercise (p<0.05). In the contralateral side, activities of the GM and EO during Single-legged hip abduction bridge, Bridge with use of a ball and single-leg hip abduction and Bridge with use of a sling and single-leg hip abduction was significantly higher than that during Bridge with use of a ball, Bridge with use of a sling and General bridging exercise (p<0.05). Conclusion: This study demonstrated that performing a bridge exercise with use of a sling and single-leg hip abduction had an effect on trunk and gluteal muscle activation. The findings of this study suggest that this training method can be clinically effective for unilateral training and for patients with hemiplegia.

Optimal Target Reliability of Bridges Based on Minimum Life-Cycle Cost Consideration

  • Wang, Junjie;Lee, J-C
    • Computational Structural Engineering : An International Journal
    • /
    • v.2 no.1
    • /
    • pp.11-17
    • /
    • 2002
  • Cost-effectiveness in design is considered for determining the target reliability of concrete bridges under seismic actions. This objective can be achieved based on the economic optimization of the expected life-cycle cost of a bridge, which includes initial cost, direct losses, and indirect losses of a bridge due to strong earthquakes over its lifetime. A separating factor is defined to consider the redundancy of a transportation network. The Park-Ang damage model is employed to define the damage of a bridge under seismic action, and a Monte Carlo method based on the DRAIN-2DX program is developed to assess the failure probability of a bridge. The results for an example bridge analyzed in this paper show that the optimal target failure probability depends on the traffic volume carried by the bridge and is between 1.0×10/sup -3/ to 3.0×10/sup -3/ over a life of 50 years.

  • PDF

Gap comparison between single crown and three-unit bridge zirconia substructures

  • Anunmana, Chuchai;Charoenchitt, Masnisa;Asvanund, Chanavut
    • The Journal of Advanced Prosthodontics
    • /
    • v.6 no.4
    • /
    • pp.253-258
    • /
    • 2014
  • PURPOSE. To compare marginal and internal gaps of zirconia substructure of single crowns with those of three-unit fixed dental prostheses. MATERIALS AND METHODS. Standardized Co-Cr alloy simulated second premolar and second molar abutments were fabricated and subsequently duplicated into type-III dental stone for working casts. After that, all zirconia substructures were made using $Lava^{TM}$ system. Marginal and internal gaps were measured in 2 planes (mesial-distal plane and buccal-palatal plane) at 5 locations: marginal opening (MO), chamfer area (CA), axial wall (AW), cusp tip (CT) and mid-occlusal (OA) using Replica technique. RESULTS. There were significant differences between gaps at all locations. The $mean{\pm}SD$ of marginal gap in premolar was $43.6{\pm}0.4{\mu}m$ and $46.5{\pm}0.5{\mu}m$ for single crown and 3-unit bridge substructure respectively. For molar substructure the $mean{\pm}SD$ of marginal gap was $48.5{\pm}0.4{\mu}m$ and $52.6{\pm}0.4{\mu}m$ for single crown and 3-unit bridge respectively. The largest gaps were found at the occlusal area, which was $150.5{\pm}0.5{\mu}m$ and $154.5{\pm}0.4{\mu}m$ for single and 3-unit bridge premolar substructures respectively and $146.5{\pm}0.4{\mu}m$ and $211.5{\pm}0.4{\mu}m$ for single and 3-unit bridge molar substructure respectively. CONCLUSION. Independent-samples t-test showed significant differences of gap in zirconia substructure between single crowns and three-unit bridge (P<.001). Therefore, the span length has the effect on the fit of zirconia substructure that is fabricated using CAD/CAM technique especially at the occlusal area.

Effects of Bridge Exercise Combined with Vibration on Abdominal Muscle Thickness (진동을 병행한 교각운동이 복부 근육 두께에 미치는 영향)

  • Jae Cheol Park;Jin Gyu Jeong
    • Journal of Korean Physical Therapy Science
    • /
    • v.30 no.3
    • /
    • pp.31-40
    • /
    • 2023
  • Background: The purpose of this study was to confirm the effect of bridge exercise combined with vibration on abdominal muscle thickness. Design: Randomized controlled trial. Methods: As study subjects, 24 adults in their 20s were classified into 12 vibration bridge exercise groups and 12 bridge exercise groups. The time was divided into before the experiment, 3 weeks after the experiment, and 6 weeks after the experiment. Two-way repeated ANOVA was used to examine changes in the muscle thickness of the external oblique, internal oblique, and transverse abdominal muscles of the trunk muscles, and the significance level was set at 0.05. If there was an interaction between time and group, post-hoc analysis was performed, and the significance level was set at 0.01. Results: There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). There was a significant difference in the external oblique muscle in the change by period, the interaction between time and group, and the change between groups (p<0.05). Conclusion: As a result of this study, bridge exercise combined with vibration had a positive effect on the muscle thickness of the external oblique, internal oblique, and transversus abdominis muscles. It suggests the possibility of using the basic data of vibration exercise and the lumbar stabilization exercise in clinical practice.

ON INFINITE CLASSES OF GENUS TWO 1-BRIDGE KNOTS

  • Kim, Soo-Hwan;Kim, Yang-Kok
    • Communications of the Korean Mathematical Society
    • /
    • v.19 no.3
    • /
    • pp.531-544
    • /
    • 2004
  • We study a family of 2-bridge knots with 2-tangles in the 3-sphere admitting a genus two 1-bridge splitting. We also observe a geometric relation between (g - 1, 1)-splitting and (g,0)- splitting for g = 2,3. Moreover we construct a family of closed orientable 3-manifolds which are n-fold cyclic coverings of the 3-sphere branched over those 2-bridge knots.

Long-Term Performance Evaluation of a GFRP Slab Bridge (GFRP 슬래브 교량의 장기성능 평가)

  • Ji, Hyo-Seon
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.3
    • /
    • pp.349-360
    • /
    • 2012
  • This paper describes a detailed assessment of the structural safety, serviceability, capacity rating and long-term performance of a glass fiber-reinforced polymer (GFRP) slab bridge superstructure. This first all-GFRP slab bridge was installed in Korea on May 2002. The GFRP slab bridge is a simply supported, its length is 10.0 m, and is designed to carry two-lane traffic and has an overall width of 8.0m. The GFRP slab bridge is a sandwich structure with a corrugated core, fabricated by hand lay-up process with E-glass fibers and vinyl ester resins. The assessment of long-term performance for the GFRP slab bridge in 2004, 2011 includes a field load testing identical to that performed in 2002. The assessment indicates that the GFRP slab bridge has no structural problems and is structurally performing well in-service as expected. The assessment may provide a baseline data for the capacity ratings assessment of the GFRP slab bridge and also serve as part of a long-term performance of all-GFRP bridge superstructure.

Calculation of Maximum Effective Temperature of Steel Box Girder Bridge Using Artificial Neural Network (인공신경망을 이용한 강박스거더의 유효온도 산정)

  • Lee, Seong- Haeng
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.96-103
    • /
    • 2018
  • An analysis using a statistical method is generally used to determine the effective temperature based on the temperature design load of a bridge. In this study, the effective temperature was calculated by building an artificial neural network (ANN) capable of improving the statistical method. A Steel box girder bridge specimen was made with a width of 2.0 m, height of 2.0 m, and length of 3.0 m and 0.2 m the upper slab. Twenty one temperature gauges were attached to measure the temperature between 2014 and 2016 for three years. An ANN was learned using the data measured from 2014~2015 and the results were compared with the Euro codes. The error rate between the Euro code and statistical analysis values was analyzed to be 4.1 % for the total measurement point. The ANN was verified and the effective bridge temperatures were calculated using the temperature data measured in 2016. The results revealed an approximate 3.97 % difference from the statistical analysis values. This degree of error is considered to be acceptable in terms of engineering for the analysis of an ANN. An ANN can easily predict the effective temperature of a bridge by knowing the input values of the region's highest temperature, bridge type, and upper asphalt thickness when designing the bridge's temperature loads.

A Study of Cervical Margin Distortion in Preheating Method during Soldering (관교의치(冠橋義齒) 납착시 Preheating 방법에 따른 치경부(齒經部) 변록의 적합도(適合度)에 관한 실험적 연구)

  • Kim, Won-Tai
    • Journal of Technologic Dentistry
    • /
    • v.6 no.1
    • /
    • pp.11-14
    • /
    • 1984
  • The auther performed this experimental study on cervical margin distortion in preheating method during soldering. 1. In soldering methods, the method using the furnace has less distortion than the method using open-flame and longer the bridge spon, the larger the distortions. 2. Table Ⅰ Showed that buccal margin, lingual margin, mesial margin and distal margin had respectively 0.01mm, 0.02mm, 0.03mm, 0.03mm closer adaptation in 3 unit bridge than in 5 unit bridges. 3. Table II showed that buccal margin, lingual margin, mesial margin and distal margin had respectively 0.06mm, 0.07mm, 0.11mm, 0.05mm closer adaptation in 3 unit bridge than in 5 unit bridges.

  • PDF