• Title/Summary/Keyword: BOK-WIRE

Search Result 74, Processing Time 0.025 seconds

A Study on the Double Dielectric Barrier Discharge for $NO_x$ reduction (이중 베리어 방전 반응기를 사용한 $NO_x$ 제거에 관한 연구)

  • Kim, Dong-Ook;Kim, Eung-Bok;Chung, Young-Sik
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2182-2185
    • /
    • 1999
  • In this experimental study we propose the double dielectric barrier discharge(DDBD) reactor to produce as high an electric field as possible. DDBD reactor is designed to remove $NO_x$ at atmospheric pressures from the moving pollution source such as diesel automobile DDBD reactor consisted of two cylinder glass tubes arranged so that the gas flow was directed between the two tubes. Inside of the inner tube was filled with small metal beads and outside of the inner tube was wounded with stainless wire to form the electrode. The outer tube was surrounded by an aluminum foil In this reactor there are three electrodes, i.e. metal bead(C), helical wire(I) and aluminum foil(0). By using DDBD reactor we will report some interesting results of treatment of the gas which is the dilute mixtures of NO in N2. And then we compared thee results with the results of cylinder-wire(CW) which is one of popularly used reactor in non-thermal plasma applications.

  • PDF

Numerical Calculation of Longitudinal Current Distribution in Grounding Electrode for Analyzing the Grounding Impedance (접지임피던스 분석을 위한 접지전극의 전류분포 수치계산)

  • Cho, Sung-Chul;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.1
    • /
    • pp.46-52
    • /
    • 2013
  • The current distribution passing through grounding electrode is required for calculating an impedance of grounding electrode using the electromagnetic field model. In this paper the numerical calculation for currents passing through a grounding electrode as a function of frequency was given. The proposed approach is based on the wire antenna model(AM) in the frequency domain. The Pocklington's equation driven from the wire antenna theory was numerically calculated by the Galerkin's method. The triangle function was applied to both the basis function and the weighting function. The current distribution of a horizontal ground electrode was simulated in MATLAB. Also these results were compared with the data obtained from the CDEGS HIFREQ calculation.

Classification and recognition of electrical tracking signal by means of LabVIEW (LabVIEW에 의한 Tracking 신호 분류 및 인식)

  • Kim, Dae-Bok;Kim, Jung-Tae;Oh, Sung-Kwun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.779-787
    • /
    • 2010
  • In this paper, We introduce electrical tracking generated from surface activity associated with flow of leakage current on insulator under wet and contaminated conditions and design electrical tracking pattern recognition system by using LabVIEW. We measure the leaking current of contaminated wire by using LabVIEW software and the NI-c-DAQ 9172 and NI-9239 hardware. As pattern recognition algorithm and optimization algorithm for electrical tracking system, neural networks, Radial Basis Function Neural Networks(RBFNNs) and particle swarm optimization are exploited. The designed electrical tracking recognition system consists of two parts such as the hardware part of electrical tracking generator, the NI-c-DAQ 9172 and NI-9239 hardware and the software part of LabVIEW block diagram, LabVIEW front panel and pattern recognition-related application software. The electrical tracking system decides whether electrical tracking generate or not on electrical wire.

Wire and Wireless Transmitting-Receiving Set for Vertical Angle and Depth Measurement of Deep Mixing Method (유무선송수신을 이용한 심층혼합처리공법 수직도 및 심도 자동측정에 관한 연구)

  • Han, Woo-Sun;Yu, Chan;Han, Man-Bok
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.10a
    • /
    • pp.629-634
    • /
    • 2002
  • Demands for the automatic measurement on angle and depth of equipment were arisen for the better construction in deep mixing method and grouting method. Civil, geotechnical, electronic, and communication experts worked together for the development of automatic measuring devices using wire and wireless transmitting-receiving set. The results on the development of automatic devices in an industrial installation will be presented.

  • PDF

Development of a Computer Program for Analysis of Induced Lightning Overvoltages on Overhead Distribution Lines (가공배전선로 유도뢰 해석 프로그램 개발)

  • Lee, Young-Han;Jung, Dong-Hak;Ha, Bok-Nam;NamKung, Do;Yoo, Hyun-Jae
    • Proceedings of the KIEE Conference
    • /
    • 1996.07b
    • /
    • pp.683-685
    • /
    • 1996
  • A computer program for calculation of induced lightning overvoltages on the multiconductor overhead distribution lines has been developed. This program is very useful in a wide range of applications for investigating the effects on distribution lines of lightning protection equipment such as lightning arresters, overhead ground wire and arcing devices.

  • PDF

Fabrication and Characterization of Silicon Device for Flow Measurement(l) (흐름측정용 실리콘 소자의 제작 및 특성 평가(l))

  • Lee, Myeong-Bok;Ju, Byeong-Gwon;Lee, Jeong-Il;Kim, Hyeong-Gon;O, Myeong-Hwan;Gang, Gwang-Nam
    • Korean Journal of Materials Research
    • /
    • v.3 no.1
    • /
    • pp.28-32
    • /
    • 1993
  • Abstract The hot wire anemometer-type flow sensor, which consisted of Ni thin film resistors evaporated on Si substrates, was fabricated and characterized. It was known that the temperature coefficients of Ni resistors were decreased as the film thickness was thinned and the operating characteristics of the fabricated flow sensor were determined as a sensitivity of 111.3${\mu}$W/(${\ell}$ pm$)^{1/2}$ and a dynamic response time of several 10 seconds.

  • PDF

Estimation of Power Collector Wear Considering the Operating Environment of a Maglev (자기부상열차의 주행 환경을 고려한 집전자 마모도 평가)

  • Lee, Kyoung-bok;Ma, Sang-kyeon;Lim, Jae-won;Park, Do-young;Son, Jeong-ryong;Kang, Hyun-il
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.38-42
    • /
    • 2017
  • The wear of the third track power collector is one of the essential check factors for safe train operation. Rapid wear of the current collector accelerates the line of the catenary. In addition, the arc generated when the catenary line is turned off causes a malfunction in the minute portion of the catenary line, thereby shortening the life of the catenary line. In this paper, to analyze the mechanical wear of the current collector during driving according to the environmental factor of the Maglev(magnetic levitation train), it was divided into dry season and wet season. the wear of metallized collector, copper alloy collector and carbon collector were measured and compared with each other. The wear rate was measured according to the position of the wire, the position of the power collector and the position per hour. Microscopic photographs of the cross section and surface of the power collector were measured. The electrical currents of the metallized collector, copper alloy collector and carbon collector were measured.

Reentrainment of Carbon Soot Particles in a Corona Discharge Reactor (코로나 방전 반응기에서 Carbon Soot 입자의 재비산)

  • Lee, Jae-Bok;Hwang, Jung-Ho;Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.7
    • /
    • pp.1002-1009
    • /
    • 2000
  • Among the various types of diesel after-treatment device, the corona discharge reactor may be considered as a powerful process for trapping submicron particles. But after precipitation on the electrodes occurs, the reentrainment of particles is severe and often causes low or negative precipitation efficiency. Experiments were performed to investigate the effect of an applied voltage on the reentrainment of soot particles from the electrodes. A co-annular laminar diffusion flame burner was used as the soot generator. When a highly negative voltage was applied, exfoliation of the deposited soot particles and an increase in concentration of particles smaller than approximately 150 nm were observed. Turbulence induced from the negative tuft corona and sputtering caused particle reentrainment from the corona wire and from plates as well. Under soot laden combustion gas, a streamer corona often occurred in the wire-cylinder reactor. Because of its transient nature, streamer corona violently increased the concentration of reentrained particles and CO gas.

System based on Java Card Using XML Digital Signature on Wireless Internet (무선 환경에서 XML 전자서명을 이용한 Java Card 기반 시스템)

  • Jang Chang-Bok;Choi Eui-In
    • The KIPS Transactions:PartC
    • /
    • v.12C no.1 s.97
    • /
    • pp.37-44
    • /
    • 2005
  • As wireless network was developed and Capability of Wireless Phone was increased, M-Commerce was activates In Wireless network environment. User Authentication and Security in E-Commerce Environment is very important, so Authentication Technology, such as WPKI and Hermes System, XML Digital Signature in Wire Network is studying. But if authentication systems was implemented heterogeneous, WPKI is difficult to implement the system, it's not interoperate with authentication system on wire internet, not support XML digital Signature. Hermes system also not interoperate with XML digital signature system. So our paper designed System that can interoperate among digital signature systems and XML document to apply XML digital signature technology on wire network to wireless network, and then implemented system that can XML digital signature to use Java Card.

The Effect of Using Nano NiO Powder Made by Pulsed Wire Evaporation (PWE) Method on SOFC Anode Functional Layer (Pulsed Wire Evaporation(PWE) Method으로 제조된 나노 NiO 분말의 SOFC 연료극 기능성층으로의 적용)

  • Kim, Hae-Won;Kim, Dong-Ju;Park, Seok-Joo;Lim, Tak-Hyoung;Lee, Seung-Bok;Shin, Dong-Ryul;Yoon, Soon-Gil;Song, Rak-Hyun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.6
    • /
    • pp.485-491
    • /
    • 2009
  • In present work, NiO/YSZ anode functional layer was prepared by nano NiO powder and 8YSZ powder. The nano NiO powders were made by Pulsed wire evaporation (PWE) method. Nano NiO- YSZ functional layer was sintered at the temperature of $900-1400^{\circ}C$. The prepared functional layer was characterized by scanning electron microscopy (SEM) and electrochemical impedance spectroscopy. The nano NiO- YSZ anode functional layer sintered at $1300^{\circ}C$ shows the lowest polarization resistance. Nano NiO- YSZ anode functional layer shows about two times smaller polarization resistance than the anode functional layer made by commercial NiO-YSZ powders. Based on these experimental results, it is concluded that the nano NiO-YSZ cermet is suitable as a anode functional layer operated at $800^{\circ}C$.