• 제목/요약/키워드: BOD removal rate

검색결과 231건 처리시간 0.028초

비점오염관리를 위한 강우유출수 처리습지의 성능평가방법 개발 (A Study on the Development of Performance Evaluation Method for the Stormwater Treatment Wetland)

  • 김영윤;김상단;이석모;성기준;송교욱;손민호
    • 한국물환경학회지
    • /
    • 제29권3호
    • /
    • pp.354-364
    • /
    • 2013
  • The performance of the stormwater wetlands can be significantly influenced by antecedent stormwater in storage at the commencement of a stormevent. As inflows are intermittent and stochastic in nature, the evaluation of the treatment efficiency of a stormwater wetland should be considered by runoff capture and water treatment characteristics during interevent periods. In this study, analytical probabilistic model is applied to identity runoff capture rate and treatment efficiency of the stormwater wetland. To achieve this, continuous rainfall data recorded in Busan for 31 years has been analyzed to derive the runoff capture rate, and 1st order kinetic decay constants ($k_V$, 1/d) are calculated from regression analysis to identify pollutants removal during interevent periods. The results show that about 60.9% of annual average runoff is captured through the stormwater wetland. The annual average treatment efficiencies of SS, BOD, COD, TN and TP is about 11.4, 8.9, 9.8, 4.3 and 9.6%, respectively. The analytical model has been compared with the numerical model and it shows that analytical model is valid. Performance evaluation methods developed in this study has the advantages of considering characteristics of rainfall-runoff, facility type and pollutant removal.

고도산화공정(AOPs)을 이용한 난분해성 염색폐수 처리 (Treatment of Refractory Dye Wastewater Using AOPs)

  • 김종오;이권기;정종태;김영노
    • 한국지반환경공학회 논문집
    • /
    • 제7권3호
    • /
    • pp.21-29
    • /
    • 2006
  • 난분해성 염색폐수를 처리하기 위한 화학적 처리 방법으로 오존단독처리와 3가지 경우의 고도산화공정[AOPs($O_3/H_2O_2$, $O_3/UV$, $O_3/H_2O_2/UV$)]의 처리특성을 실험적으로 검토하였다. 각각의 처리방법에서 합성 염색폐수를 대상으로 $COD_{cr}$ 및 색도의 제거효율, 생분해도(biodegradability)향상에 대한 처리특성을 상대적으로 비교 평가하였고 pH, 온도, 주입량, 순환유량 등을 주요운전인자로 하여 각 산화공정의 최적운전 조건을 파악하였다. 대상으로 한 모든 공정에서 염색폐수의 색도는 단시간에 대부분 제거되었지만, $COD_{cr}$ 제거측면과 생분해도 향상에서는 $O_3/H_2O_2/UV$ 공정이 가장 좋은 처리효율을 나타냈다.

  • PDF

혐기/무산소/호기공법의 원생동물 군집구조 (Protozoa Structure of Anaerobic/Anoxic/Oxic Process.)

  • 이찬형;문경숙
    • 한국미생물·생명공학회지
    • /
    • 제31권3호
    • /
    • pp.264-270
    • /
    • 2003
  • 1.북부 하수처리장에서 동정된 원생동물 및 후생동물의 종류는 32속으로 섬모충류는 17속이었다. 총 개체수는 연평균 5,266개체/ml(2,631∼9,744)이며, 속별 개체수는 Trachelophyllum이 가장 많았다. 종류별로는 편모충류가 6속(11%), 육질충류 3속(7%), 섬모충류 17속(78%), 후생동물이 6속(4%)이며, 섬모충류는 나구류와 시모류가 각각 33%, 23%을 차지하였다. 총 개체수는 하절기에 감소하고 동절기에 상승하는 경향을 나타내었다. 2. 수온 $20^{\circ}C$ 미만인 경우, 속별 개체수와 유출수 BOD, SS농도는 음의 상관관계가 형성되고, 속별 개체수와 유출수 COD, TN, TP농도는 양의 상관관계가 형성되었다. 상관분석의 결과 $20^{\circ}C$미만의 자료에서 Lepadella가 TP제거율에 대한 지표 미생물로의 가능성이 나타나며, Trochilia, Entosiphon, Coiepus는 TN제거율의 지표미생물로의 가능성이 추정된다. 3. 수온 $20^{\circ}C$ 이상인 경우, $20^{\circ}C$ 미만인 경우보다 상관계수가 낮았으며, 전반적으로 속별 개체수와 수질 항목이 음의 상관관계를 형성하였다. Entosiphon, Paramecium은 출현빈도는 낮지만 유출수 TP농도와 양의 상관관계를, TP제거율과 음의 상관관계를 형성함으로 이들 원생동물속의 개체수 증가시에는 유출수 TP가 악화된다는 점에 주의하면서 운전하여야 한다.

가변형 간벽을 이용한 SBR 공정의 실증 Pilot 연구 (Positive Pilot Research of SBR Process with Flexible Vertical)

  • 김만수;박종운;박철휘
    • 대한환경공학회지
    • /
    • 제27권4호
    • /
    • pp.438-444
    • /
    • 2005
  • 본 연구에서는 가변형 간벽을 설치하고 이 가변형 간벽의 열고 닫음에 따라 하나의 SBR 반응조를 시간적으로 뿐만 아니라 공간적으로도 분리시킴으로써 aerobic, anaerobic 또는 anoxic 상태의 구분을 명확히 하여 탈질 및 탈인 효율을 증대시켰다. 본 연구 결과 $COD_{Cr}$/N ratio 10($BOD_5$/N ratio 5) 정도의 실 플랜트 조건에서 T-N 및 T-P 제거효율은 90.9%와 75%를 나타내었다. 또한 잉여슬러지내 인 함유량 조사결과 기존 처리장에서 발생된 잉여슬러지의 인 함량비율을 100%라 할 때 pilot plant에서 발생된 잉여슬러지의 인 함유율은 생 슬러지의 경우 133.6%, 건조 슬러지의 경우 124.3%로서 기존 처리장의 슬러지내 인 함유율보다 $25{\sim}30%$ 정도 높은 것으로 조사되었다. 따라서 SBR반응조 내에 가변형 간벽을 설치함으로서 명확한 탈질 탈인을 위한 반응조건을 제시해 줄 수 있는 것으로 나타났다.

病院廢水의 特性과 處理에 關한 硏究 -消毒劑가 활성스러지법에 미치는 영향- (Studies on the Wastewater of General Hospital and It에s Treatment -Effects of Disinfectants on Activated Sludge Process-)

  • Ra, Kyu Hwan;Ok, Chi Sang
    • 한국환경보건학회지
    • /
    • 제10권1호
    • /
    • pp.13-20
    • /
    • 1984
  • The hospital wastewaters have to be so disposed as to prevent disease and to protect water resources from hazardous substances disinfectants, medicines, and chemicals. Polyvinylpyrrolidone-iodine complex (povidone-iodine) is widely used in the hospital as one of disinfectants. This study was carried out to manifest the effect of disinfectants in growth of activated sludge in treatment of the hospital wastewater by the activated sludge process. The results are as follow. 1. An average water quality of the hospital wastewater showed 7.2 in pH, 3.2 ppm in DO, 293.3 ppm in SS, 96.0 ppm in BOD, 151.1 ppm in COD, 0.4 ppm in povidone-iodine, 0.5 ppm in phenols, 5.4 ppm in surfactants, 1.6 ppm in o-phosphate, 4.6 ppm in $NH_3-N, 249\times 10^4$ counts/100 ml in coliform group organisms, and $1,369\times 10^2$ counts/ml in general counts of bacteria. And wastewater amounts discharged per bed was calculated 70 l/d/bed. 2. In batch culture activated sludge process, each of cresol and povidone-iodine was not effected in less than 0.1 ppm concentration, but the more concentration, the more inhibit the growth rate of activated sludge. In the mixture of two disinfectants, the growth was more inhibited the effect of single disinfectants. So that this reaction is considered as addition effect of two disinfectants. 3. The removal rates of the disinfectants-by continuous culture activated sludge process were 77.6% in 0.4 ppm povidone-iodine, and in BOD was 85.6%. 4. It is desirable that the hospital wastewater is planed in order to be discharged to two system separately, sewer from life system and wastewater from medical system. From those results, it has been concluded that the hospital wastewater has to be treated safely by the activated sludge process.

  • PDF

위락시설지역의 초기세척현상과 초기 강우-유출고 저류에 따른 저감효율 분석 (Analysis of First Flush of Recreation Park and Removal Rate According to Rainfall-Runoff Storage Depth)

  • 정재운;박하나;최동호;백상수;윤광식;백원진;범진아;임병진
    • 한국물환경학회지
    • /
    • 제29권5호
    • /
    • pp.648-655
    • /
    • 2013
  • Nonpoint source pollution characteristics of recreation park was investigated. Runoff ratio of recreation park ranged 23-57%, which was lower than other urban area since impervious area was less than 37%. The average BOD, COD, TOC, SS, T-N, T-P, were 14.09, 32.86, 12.19, 121.51, 7.78 and 0.72 mg/L, respectively. First flush of recreation park was analyzed by normalized cumulative load - volume curve and mass first flush ratio(MFFn), MFF10 for BOD, COD, SS, T-P, T-N, TOC were 2.90, 1.59, 2.15, 2.74, 2.60, and 1.59, respectively. Observed data showed that 62% of pollutant could be removed by storaging 5 mm rainfall-runoff and even 3 mm depth could store up to 50% of pollutant in runoff.

하.폐수 고도처리시 F/M비 변화에 따른 유기산 잔류 농도가 슬러지 침강성에 미치는 영향 (Influence of Organic Acids Residual Concentration by the Change of F/M Ratio on Sludge Settleability in Advanced Sewage Treatment Processes)

  • 박영기;김영일;김슬기
    • 대한환경공학회지
    • /
    • 제28권1호
    • /
    • pp.42-47
    • /
    • 2006
  • 생물학적 고도처리는 혐기, 무산소, 호기의 조건을 반복하거나 재배열함으로서 이루어지는데 이때 혐기조와 무산소조에서는 유기산이 발생한다. 여기서 발생한 유기산은 질소와 인의 제거와 슬러지침강성에 중요한 인자로 작용한다. 따라서 본 연구에서는 하 폐수 고도처리 시 F/M비 변화에 따른 유기산의 발생정도와 잔류농도 변화와 기에 따른 유기물과 질소의 제거 특성과 처리효율 및 슬러지 침강성과의 관계를 모색하기 위해 특성을 검토 하였다. 고도처리를 위해 $A^2/O$ 공정을 사용하였고 MLSS의 농도의 변화로 F/M비를 조절하였다. F/M비를 $0.16{\sim}0.08$ kg-BOD/kg-MLSS/day로 변화 시켰을 때 F/M비에 감소에 따라 회분식 반응기에 의한 유기산의 생성량의 증가하였고 잔류 유기산 농도는 감소하였다가 증가하였다. F/M비가 $0.16kg/kg{\cdot}d$ 실험 조건에서 SVI와 SS는 높게 나타났으며 F/M비가 $0.11{\sim}0.13kg/kg{\cdot}d$로 높아짐에 따라 감소하여 양호한 상태를 보이다 F/M비가 증가함에 SVI와 SS도 지속적으로 증가하여 $0.08kg/kg{\cdot}d$에서 높은 SVI와 SS 농도를 나타내었다. 무산소조의 유기산 잔류 농도 그리고 탈질률을 비교한 결과 무산소조의 유기산 잔류량이 적을수록 탈질률은 증가하였다. 슬러지 침강성과 질소 제거효율을 고려한 최적의 유기산 잔류 농도는 $1.4{\sim}2.2$ mg/L이며 이때의 F/M비는 $0.11{\sim}0.13$ kg-BOD/kg-MLSS/day범위로 나타났다.

다공성 콘크리트의 보 및 하상재료 적용에 따른 하천 수질정화 능력 평가 (Estimation of Water Purification Ability with Applying Porous Concrete to Weir and Riverbed Materials)

  • 최이송;김진홍;최계운;오종민
    • 한국수자원학회논문집
    • /
    • 제36권6호
    • /
    • pp.1013-1023
    • /
    • 2003
  • 본 연구에서는 최근 환경재료로서 관심이 모아지고 있는 다공성 콘크리트를 하천구조물(보 및 하상재료)에 적용함으로써 수질을 개선하고자 수행하였다. 먼저, 물리ㆍ화학적 특징을 평가해 본 결과, 공극률 10% 및 30%의 다공성 콘크리트의 압축강도는 일반 콘크리트의 최저 압축강도(180 kgf/$cm^2$)를 상회하여 하천구조물에 적용 가능하였고, 알칼리 용출에 의한 부착 미생물에의 영향도 거의 없을 것으로 판단되었다. 또한, 일반 콘크리트와 다공성 콘크리트로 하천구조물을 제작하여 부착물의 성상을 비교ㆍ검토한 결과, 같은 유속조건에서 부착물의 DW량은 일반 콘크리트에 비해 다공성 콘크리트가 1.6배 높은 것으로 나타났으며, 반면에 유속을 10배 달리한 실험의 결과에서는 거의 같은 부착물의 DW량을 보여 부착매질에 의한 영향이 유속에 의한 영향보다도 더 크게 작용한 것을 알 수 있었다. 부착물의 성상에서도 건조물중 AFDM의 비가 다공성 콘크리트에서 더 큰 것으로 나타났으며, 특히 N, P의 비가 높은 것은 부착 생물에 의한 흡수 및 흡착, 물질대사에 의해 유기물 제거가 더 컸기 때문으로 사료된다. 수질개선 효과에 있어서 전 구간을 종합한 결과, 다공성 콘크리트를 적용한 하천구조물에서의 SS, BOD, COD, T-N, T-P의 제거효율은 일반 콘크리트 보다 각각 34.6%, 36.9%, 33.9%, 18.3%, 21.6% 씩 증가하여 하천 수질개선에 크게 기여한 것으로 평가되었다.

Rhodopseudomonas palustris KK14를 이용한 소규모 돈분폐수처리공정의 최적화 (Optimization for Small-scale Process of Swine Wastewater Treatment Using Rhodopseudomonas palustris KK14)

  • 김한수;오준현;김혁일;조홍연;양한철
    • Applied Biological Chemistry
    • /
    • 제37권4호
    • /
    • pp.303-309
    • /
    • 1994
  • 광합성세균을 이용한 농축산가의 소규모 가축 폐수처리공정 개발을 위한 연구의 일환으로 고농도에서 유기산의 자화율이 높은 Rhodopseudomonas palustris KK14를 사용하여 돈분폐수처리공정의 최적화를 flask-scale 및 laboratory-scale에서 실시하였다. 반연속식으로 실시한 flask-scale에서 광합성세균 반응조는 HRT 6일, 광합성세균오니량 5%(v/v), 반송오니량 10%(v/v)로 했을 때 안정된 83%의 COD 제거율 및 적절한 $4{\sim}5\;g/l$의 MLSS가 유지되었다. 산생성 반응조와 광합성세균 반응조의 working volume을 각각 5.2 l와 15 l로 scale-up한 실험실적 실험에서는 원폐수 대비 COD와 BOD의 제거율이 각각 95%와 96%를 나타냈으며 광합성세균 반응조의 COD 용적부하율 및 오니부하율은 각각 $3kg\;COD/m^3/day$와 1.1kg COD/kg MLSS/day를 유지함으로써 적당한 MLSS농도가 유지되었고 부가적으로 폐수처리가 진행되면서 악취가 제거되는 효과를 나타내었다.

  • PDF

침적식 부직포 막분리를 이용한 생물학적 폐수처리 (Biological Wastewater Treatment Using Submerged Nonwoven Fabric Separation)

  • 최형섭;문병현;허종수;이홍재
    • 한국환경농학회지
    • /
    • 제16권2호
    • /
    • pp.156-160
    • /
    • 1997
  • 침적식 부직포 막분리와 생물학적처리를 조립한 본 연구시스템을 합성폐수에 적용 실험한 결과 다음과 같은 결론을 얻을 수 있었다. 1. 부직포는 기존 여과막보다 공극이 크므로 부직포 모율을 하루정도 침적한 후 생물여과막이 형성된 후 처리수가 안정됨으로 장치의 설치후 하루이상 경과한 후 가동되어야 한다. 2. 수리학적 체류시간, 부하량등의 변화에도 유기물 제거율은 평균 $COD_{Cr}$ 86.0%, $COD_{Cr}$ 90.0%, BOD 95.2%를 나타내었으며, 유출수 SS은 평균 6.2mg/l이었다. 3. 플럭스는 운전 초기 및 높은 압력에서 감소율이 크게 나타났으며 흡입압 $21{\sim}25cmHg$(약 30kpa)에서 $0.124m^3/m^2day$로 안정되었다. 4. 본 시스템의 단위체적당 처리량을 증가시키기 위한 적정한 부직포막의 선정 및 막면의 증가와 부직포 표면의 생물여과막의 조절을 위한 계속적인 연구가 필요하다고 사료된다.

  • PDF