• 제목/요약/키워드: BEAM

검색결과 19,736건 처리시간 0.054초

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

호흡주기에 따른 방사선입체조형치료법의 개발 (Development of Conformal Radiotherapy with Respiratory Gate Device)

  • 추성실;조광환;이창걸;서창옥
    • Radiation Oncology Journal
    • /
    • 제20권1호
    • /
    • pp.41-52
    • /
    • 2002
  • 목적 : 호흡주기에 따른 위치변동 감지센서를 이용하여 종양의 위치가 일정워치에 있을 때만 방사선을 치료하는 호흡 동기치료기구를 제작하고 일정한 호흡주기 상태에서 수행된 CT simulation과 3차원 입체조형치료계획에 따라 방사선을 치료하는 시스템을 개발하고자 하였다. 호흡유무에 따른 종양의 치료 마진(margin)을 측정하고 계획용표적체적(planning target volume:PTV)의 크기에 따른 선량체적표(dose volume histogram:DVH)와 종양억제확률(tumor control probability:NTCP), 건강조직손상확률(normal tissue complication probability:NTCP) 및 선량 통계자료를 통하여 치료성과를 평가하고 선량증강 범위를 예측하고자 하였다. 대상 및 방법 : 종양이 비교적 작고 전이가 없는(T1N0M0) 5명의 폐암환자를 선택하여 X-선 조준장치를 이용하여 횡격막의 이동거리를 측정하는 방법으로 내부장기의 운동을 평가하였다. 호흡동기치료기구는 끌어당김 센서가 부착된 허리띠 모양으로 구성되었으며 이를 흉곽 또는 복부에 부착하여 호흡주기에 의한 흉곽의 크기변동에 따라 센서의 회로가 개폐되고 이것을 선형가속기의 조종간에 연결하는 간단한 기구로서 감도와 재현성이 높았다. 호흡을 배기한 후 일시적 호흡이 정지된 상태에서 Spiral-CT (PQ-5000)로 3차원 영상을 획득하고 Virtual CT-simulator (AcQ-SIM)에 의하여 종양의 위치와 주위 장기들을 확인 도시하였으며 3차원 치료계획장치(Pinnacle, ADAC Co.)를 이용하여 3차원 입체조형치료를 계획하였다. 치료계획의 평가는 호흡동기치료기구의 사용유무에 따른 PTV의 크기에 따라 최적 선량분포를 구사하였으며 각각의 DVH, TCP, NTCP 및 선량통계자료를 도출 비교 검토하였다. 결과 : X-선 simulation에서 폐암환자의 횡격막 이동은 약 1 cm에서 2.5 cm로서 평균 1.5 cm로 측정되었고 자유호흡시 PTV는 CTV (clinical target volume)에 약 2 cm 마진을 주었으며 호흡동기치료기구를 사용하였을 때는 0.5 cm 마진이 적당한 것으로 측정되었다. 종양의 PTV는 연장 마진의 거의 자승비로 증가하였으며 TCP의 값은 마진 범위 $(0.5\~2.0\;cm)$에 관계없이 거의 일정하였고 NTCP의 값은 마진 크기에 따라 평균 $65\%$로 급속히 증가하였다. 결론 : 호흡주기에 따른 위치변동 감지센서를 이용한 호흡동기치료기구는 종양의 위치가 일정할 때만 방사선이 조사되는 간단하고 정확한 장치로서 3차원 입체조형치료 및 강도변조방사선치료에서 매우 유용한 장치임을 확인할 수 있었다. 또한 호흡조절 방사선입체조형치료방법의 기술과 시술절차를 확립시키고 정량적인 선량평가를 위하여 DVH, TCP, NTCP 등의 정량분석과 종양의 투여 선량 증가량(dose escalation)을 예측하는 기초자료를 제공할 수 있었다.

직장풍선을 삽입한 전립선암 환자의 수술 후 방사선 치료 시 용적변조와 세기변조방사선치료계획 비교 평가 (Comparison and evaluation of volumetric modulated arc therapy and intensity modulated radiation therapy plans for postoperative radiation therapy of prostate cancer patient using a rectal balloon)

  • 정해윤;석진용;홍주완;장남준;최병돈;박진홍
    • 대한방사선치료학회지
    • /
    • 제27권1호
    • /
    • pp.45-52
    • /
    • 2015
  • 목 적 : 전립선암의 방사선치료는 치료기법에 따라 주요장기와 정상조직의 선량분포에 차이가 나타난다. 본 연구에서는 전립선암 환자의 수술 후 방사선치료 시 직장풍선을 삽입한 환자에게 회전수를 달리한 용적변조회전치료(volumetric modulated arc therapy, VMAT)계획과 세기변조방사선치료(intensity modulated radiation therapy, IMRT)계획을 각각 수립하여 선량분포 특성을 비교하고 치료의 효율성을 평가하고자 한다. 대상 및 방법 : 본원에서 전립선암 수술 후 방사선 치료를 시행한 10명의 환자를 대상으로 하였다. 직장풍선을 삽입한 환자의 CT영상을 3 mm 두께로 획득하고 Eclipse (Ver 11.0, Varian, Palo Alto, USA)를 사용하여 HD120MLC가 장착된 Truebeam STx (Varian, Palo Alto, USA)의 10 MV 에너지를 적용하였다. 환자마다 1 Arc, 2 Arc VMAT계획과 7조사면의 IMRT계획을 수립하였으며 각 치료계획의 선량체적제한과 plan normalization 값은 동일하게 적용하였다. 수립된 세 가지 치료계획을 평가하기위해 PTV의 coverage, conformity index (CI), homogeneity index (HI)를 비교하였고, PTV주변 정상조직의 선량퍼짐정도를 알아보기 위해 50% 등선량체적과 PTV체적의 비($R_{50%}$)를 산출하였다. 결정장기 (organ at risk, OAR)에서는 직장의 $D_{25%}$와 방광의 $D_{mean}$을 비교하였고 치료의 효율성을 평가하기 위해서 총 MU와 조사시간을 측정하였으며, 각 평가항목별 결과는 환자 10명의 평균값으로 비교분석하였다. 추가적으로 선량전달 정확도를 검증하기 위해 EPID를 이용한 portal dosimetry를 진행하였다. 결 과 : 각 치료계획에서 나타난 PTV coverage와 HI의 차이는 크지 않았지만 CI는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 1.036, 1.035, 1.230으로 VMAT에 비해 7F-IMRT가 높았고(p=0.00), $R_{50%}$는 3.083, 3.054, 3.991로 2A-VMAT이 제일 낮았고 7F-IMRT에서 가장 높게 나타났다(p=0.00). 치료계획에 따른 직장의 $D_{25%}$는 VMAT에서 비슷했지만 7F-IMRT가 약 7% 높게 나타났고(p=0.02), 방광의 $D_{mean}$은 큰 차이가 없었다(P>0.05). 총 MU는 1A-VMAT, 2A-VMAT, 7F-IMRT에서 각각 494.7, 479.7, 757.9로 7F-IMRT가 가장 많았고(p=0.00), 조사시간은 65.2초, 133.1초, 145.5초로 1A-VMAT이 확연히 짧았다(p=0.00). portal dosimetry 검증에서는 모든 치료계획에서 99.5% 이상의 gamma pass rate(2 mm, 2%)을 보였다(P=0.00). 결 론 : 본 연구결과 직장풍선을 삽입한 전립선암 환자의 수술 후 방사선치료 시, 치료기법에 따른 PTV coverage의 차이는 크지 않았지만 1A, 2A-VMAT이 7F-IMRT에 비해 정상조직과 직장선량을 낮추는데 효과적이었다. VMAT중에서는 $R_{50%}$와 MU가 2A-VMAT에서 다소 낮았지만 조사시간이 짧은 1A-VMAT이 치료에 더 효율적이며 환자의 치료 중 움직임 또한 줄일 수 있을 것으로 사료된다.

  • PDF

대구·경북지역 보건소 성교육 담당자의 훈련 및 업무현황과 개선방안 (Training, Working State and Ways of Improving Work of Sex Education Counselors in Health Centers)

  • 염석헌;김창윤;이경수
    • 농촌의학ㆍ지역보건
    • /
    • 제27권2호
    • /
    • pp.159-175
    • /
    • 2002
  • 본 연구는 대구광역시와 경상북도 보건소의 성교육 상당 담당자들의 구체적인 직무 현황과 실태를 조사하고 비교 분석하여 제반 문제점을 파악한 후 개선 방안을 도출하고, 이를 통하여 성교육 및 상담의 효율적인 수행방안을 제시하고자 수행되었다. 정상북도의 경우 총 53명을 교육하여 보건소당 평균 2.3명을 교육하였고, 보건소별로는 1명부터 5명까지 배치되어 있었다. 대구광역시의 경우도 10명을 교육하였으나, 보건소별로는 0명부터 3명까지 차이를 보였다. 성교육과 상담교육을 이수한 근무자 중에서 교육이수 후 성상담 업무를 담당한 경험이 있는 경우는 38명으로 66.7%를 차지하였다. 전체 31개 보건소 중 현재 성교육 업무를 담당하고 있는 담당자 27명이 응답한 내용을 분석해 보면 다음과 같다. 성교육이나 상담시 사용하는 자료에 대한 복수응답 결과 비디오를 이용한 경우가 25건(92.6%), 책이나 소 책자가 23건(85.2%), 사진을 이용한 경우가 10건(37.0%), 빔프로젝트 8건(29.6%), 슬라이드를 이용한 경우가 7건(25.9%) 순이었다. 성교육과 상담업무 담당자의 업무별 투입시간 비율을 보면, 성교육 외의 업무가 76.2%, 학교현장에서의 성교육 7.6%, 성교육 자료수집 5.7%, 성교육 자료개발 3.5%, 청소년 상담 3.0%순이었다. 성교육과 상담실시 여부를 분석한 결과 27개 보건소 중에서 유치원 학생에 대하여 성교육을 실시하고 있는 보건소는 12개로 44.4%, 초등학교는 13개로 48.1%, 중학교는 19개로 70.4%, 고등학교는 14개로 51.9%, 성인 대상의 교육과 상담은 10개 보건소에서 교육을 실시하고 있어 37.0%로 나타났다. '99년도 한해 동안 각 보건소에서 실시한 성상담 건수는 평균 301건이었으며, 보건소에서 실시한 현장 성 교육 횟수는 유치원이 13.1회, 초등학교 7.5회, 중학교 4.8회, 고등학교 10.9회, 그리고 성인을 대상으로 한 교육횟수가 21.0회였다. '99년 한해 동안 각 보건소에서 실시한 성교육 인원은 유치원이 평균 782명, 초등학교가 235명, 중학교 240명, 고등학교 448명, 그리고 성인 교육이 1,534명으로 나타났다. 성교육 담당자들의 업무에 가장 큰 문제점에 대한 응답 중 '업무량이 과중하다'가 9명(33.3%), '성교육 자료 부족'이 8명(29.6%)으로 가장 많았다. 성교육 담당자의 업무와 관련된 개선방안에 대한 응답에서 성교육을 담당하는 기관이 더욱 전문적이고 체계적이어야 한다는 지적이 70.4%로 가장 높았고, 교육 자료가 더욱 구체적이고 세분화되어야 한다고 응답이 44.4%, 보건소 성상담요원의 업무량의 감소로 인한 성 상담과 교육에의 전문화와 체계화에 대한 의견이 37.0%, 다음으로는 학교, 교사와 보건소와의 협조 강화가 29.6%였다. 이상의 결과로 볼 때, 현재 보건소의 성교육 상담 인력의 훈련과 배치 및 활용은 효율적이지 못하다고 판단되며, 인력의 효율적 활용을 위한 인사교류 방안의 개선과 지역의 성교육과 상담 수요에 따른 인력 양성 계획이 필요하다. 또한 보건소의 성교육을 효율적으로 수행하기 위한 전문성 확보를 위해 담당자의 지속적인 교육과 업무수행을 위한 교육자료의 개발과 보급이 필요하다.

  • PDF

사차원전산화단층촬영과 호흡연동 직각 Kilovolt 준비 영상을 이용한 간 종양의 움직임 분석 (Evaluation of the Positional Uncertainty of a Liver Tumor using 4-Dimensional Computed Tomography and Gated Orthogonal Kilovolt Setup Images)

  • 주상규;홍채선;박희철;안종호;신은혁;신정석;김진성;한영이;임도훈;최두호
    • Radiation Oncology Journal
    • /
    • 제28권3호
    • /
    • pp.155-165
    • /
    • 2010
  • 목 적: 4-dimensional computed tomography (4DCT) 영상과 on board imaging (OBI) 및 real time position management (RPM) 장치로 매 회 치료 시마다 얻은 호흡연동 직각 kilovolt (KV) 준비 영상(gated orthogonal kilovolt setup image)을 이용해 간암 환자를 치료하는 동안 발생하는 종양 위치의 불확실성을 평가하고자 했다. 대상 및 방법: 3차원입체조형치료가 예정된 20명의 간암 환자를 대상으로 RPM과 전산화단층촬영모의치료기를 이용해 치료계획용 4DCT를 시행했다. 표적 근처에 위치한 간동맥화학색전술 후 집적된 리피오돌(lipiodol) 혹은 횡격막을 종양의 위치 변이를 측정하는 표지자로 선택했다. 표지자의 위치 차이를 이용해 온라인 분할간 및 분할중 내부 장기 변이와 움직임 진폭을 측정했다. 측정된 자료의 정량적 평가를 위해 통계 분석을 실시했다. 결 과: 20명 환자로부터 측정된 표지자의 분할간변이의 중앙값은 X (transaxial), Y (superior-inferior), Z (anterior-posterior) 축에서 각각 0.00 cm (범위, -0.50~0.90 cm), 0.00 cm (범위, -2.4~1.60 cm), 0.00 cm (범위, -1.10~0.50 cm) 였다. 4명의 환자에서 X, Y, Z축 중 하나 이상에서 0.5 cm를 초과하는 변이가 관찰되었다. 4DCT와 호흡연동 직각 준비 영상으로부터 얻은 표적의 움직임 진폭의 차이는 X, Y, Z 축에서 각각 중앙값이 -0.05 cm (범위, -0.83~0.60 cm), -0.15 cm (범위, -2.58~1.18 cm), -0.02 cm (범위, -1.37~0.59 cm) 였다. 두 영상간 표적의 움직임 진폭 차이가 1 cm를 초과하는 환자가 Y축 방향으로 3명 관찰되었으며, 0.5 cm 초과 1 cm 미만의 차이를 보이는 환자도 Y축과 Z축 방향을 합쳐 5명 관찰되었다. 분할중 표지자 위치 변이의 중앙값은 X, Y, Z축에서 각각 0.00 cm (범위, -0.30~0.40 cm), -0.03 cm (범위, -1.14~0.50 cm), 0.05 cm (범위, -0.30~0.50 cm)였으며 2명의 환자에서 1 cm를 초과하는 변이가 Y축 방향으로 관찰되었다. 결 론: 4DCT와 호흡연동 직각 KV 준비 영상으로 얻은 표지자의 분할간, 분할중 및 움직임 진폭에서 큰 변이가 관찰되었다.

고려(高麗) 금동탑(金銅塔)을 통해 본 법주사(法主寺) 팔상전(捌相殿)의 구조형식계통(構造形式系統) (The Structural Lineage of Palsangjeon in Pubjoo Temple Analyzed through Gilt-bronze Pagoda in the Koryo Period)

  • 김경표
    • 건축역사연구
    • /
    • 제14권1호
    • /
    • pp.89-105
    • /
    • 2005
  • The central aim of this thesis is to see if the structure of Palsangjeon(捌相殿) in Pubjoo Temple(法住寺), a five sto wooden pagoda in Chosen(朝鮮) Dynasty, was handed down from the ancient and middle ages. This study was performed through an analysis of Gilt-Bronze Pagoda built in Koryo(高麗) period. In other words, it is aimed at analyzing which lineage the structure of Palsangjeonbelongs to as a wooden pagoda. In analyzing the structure of Palsangjeon, I attempted to find out its source from the remains of Koryo period prior to the Chosen Dynasty. Examples are the Gilt-Bronze Pagoda, built during the Koryo period. I have also examined its relationship with other existing wooden pagodas and remains. The analysis of Palsangjeon, a five story wooden pagoda in Chosen Dynasty, focuses on the following: First, I explored the possibilities of whether the structure of Palsangjeon was newly invented in Chosen Dynasty, or if it had been derived from the wooden pagodas in the Koryo period. Secondly, I tried to find out if the stable vertical planes, with a great successive diminution ratio, were derived from the middle age, i.e. Koryo period. The results of the study of Palsangjeon through Gilt-Bronze Pagoda analysis are as follows: 1. The structure of Gilt-Bronze Pagoda, a wooden pagoda from the Koryo period, is roughly classified into the accumulation type, using pipe pillars, and the one story type using whole pillars. In the accumulation type, stories are connected in either a flat format or an intervening format. The Gilt-Bronze Pagoda is mainly composed of pipe pillars, with some whole pillars. However, the central pillar was omitted in the building structure. Generally, the upper and lower stories are connected by pipe pillars in a crutch format. All the pillars, whether they are pipe pillars or whole pillars, used Naiten(內轉) technology. The Eave supporter has the Haang type(下昻) and the Muhaang type(無下昻). In most cases, high balustrades are furnished, but few tables of high balustrades have been found. The slanting roof formats have been handed down from Paekche(百濟), Silla(新羅), or Koryo(高麗). However, the structure of the octagon is assumed to be derived from Koguryo(高句麗). The structure of the Gilt-Bronze Pagoda from the Koryo period is mainly composed of accumulated flat squares, with some spire types. intervening format, the structure of Palsangjeon used whole pillars in a half story format in which upper level side pillars are installed on the lower level tie beam. From the Bronze Pagoda from the Koryo period, we can assume that the half story format of wooden pagodas that has stable vertical planes with a great successive diminution ratio was created during the mid-Koryo period at the latest and had been idly developed by the time of the Chosen Dynasty. 3. The whole pillars in Palsangjeon are also found in Gilt-Bronze Pagodas from the Koryo period. Hence, all of the pillars in Palsangjeon seem to have been handed down from the ancient construction technology. They were also used in the construction of wooden pagodas from the Koryo period. Therefore, it is assumed that Palsangjeon was constructed using the construction technology of the Chosen Dynasty that had been developed from the wooden pagoda construction technology of the Koryo period. The stable vertical planes with a great successive diminution ratio in Palsangjeon are derived from ancient Korean wooden pagodas, which have developed into indigenous Korean wooden pagodas with fairly stable vertical planes and a great design, in the half story format of Koryo and Chosen Dynasty. Therefore, it is assumed that the structure of Palsangjeon has a systematic relationship with traditional Korean wooden pagodas and is one of the indigenous Korean wooden pagoda structures. 4. In China, the intervening format has been mainly used between stories in multi-story architecture since the ancient days. At the same time, the flat format as also used in ancient and middle ages. However, the flat format was replaced by whole pillars during the Ming(明) and Manchu(淸) Dynasties, in favor of simple and compact construction. The half-story format, in which upper level side pillars are installed on tie beams, has been found in some cases, but it doesn't seem to have been the primary construction technology. Few traces of the half-story format have been found in multi-story architecture in Japan, and it has not been used as a general construction format. By contrast, the half-story format, which seems to have been derived from the Koryo period, was used as a general construction format in multi-story architecture of the Chosen Dynasty. The construction technology of multi-story architecture is related to that of multi-story wooden pagodas, but they have different production technologies. It seems that the structure of Palsangjeon did not just adopt the construction technology of multi-story architecture in the Chosen Dynasty, but it was developed from wooden pagodas in the Koryo period, including the Gilt-Bronze Pagoda. 5. Since the ancient days, most Chinese and Japanese wooden pagodas have adopted an accumulation type of structure using pipe pillars, with accumulated pointed towers. On the other hand, though most Korean wooden pagodas have also adopted an accumulation type of structure from the ancientdays, one story type using whole pillars was created in the Koryo and Chosen Dynasties. The wooden pagoda structure of Palsangjeon, with stable vertical planes in a half story format, is a unique Korean construction technology, different from the construction technologies of Chinese and Japanese wooden pagodas. This thesis clearly determined the structural characteristics of Palsangjeon. However, various remains have yet to be analyzed in depth, to establish an accurate construction technology system. In the beginning of this thesis, I had difficulty in precisely interpreting the internal structure of the Gilt-Bronze Pagoda from its appearance. However, in the process of study, the more serious problem was that there are few remains or ruins of multi-story architecture in ancient and the middle ages of Korea. Therefore, it is urgent to discover various remains in the future. This thesis succeeded in determining the structural characteristics of Palsangjeon. However, it fell short of clarifying the structural lineage of the stable vertical planes, although they show indigenous Korean architectural taste, representing the unique national emotion, and the construction format of multi-story wooden pagodas in Korea. I hope this is clarified in the future research.

  • PDF

국소 진행된 자궁경부암의 방사선치료와 저용량 cisplatin 항암요법 동시치료시 급성독성 밀 초기반응 평가 (Low Dose Cisplatin as a Radiation Sensitizer in Management of Locally Advanced Scluamous Cell Carcinoma of the Uterine Cervix : Evaluation of Acute Toxicity and Early Response)

  • 김헌정;조영갑;김철수;김우철;이석호;노준규
    • Radiation Oncology Journal
    • /
    • 제17권2호
    • /
    • pp.113-119
    • /
    • 1999
  • 목적 :국소적으로 진행된 자궁경부암 환자에서 저용량의 Cisplatin을 방사선민감제로 사용하여 방사선치료와 동시 치료하였을 때의 급성독성 평가와 초기 반응을 평가하기 위하여 연구를 시행하였다. 대상 및 방법 : 본 연구는 1996년 12월부터 1999년 1월까지 FIGO Stage IIB-IIIB의 진행된 자궁경부암 환자 38명을 대상으로 하였다. 16명은 자궁경부암의 크기가 4cm이상인 환자들로 방사선 치료와 저용량의 cisplatin을 매일 동시에 치료 하였으며, 나머지 환자에선 방사선 치료 단독으로 치료하였다. 방사선치료는 골반강에 외부 방사선치료로 4500 cGy(3060cGy시행이후 midline block 추가), 자궁옅조직으로 침범이 있는 경우에는 자궁옅조직으로 방사선치료 부위를 줄여 900-1000cGy 추가치료를 시행하였고, 내부치료는 Ir$^{192}$고선량 근접 치료기(micro-Selectron HDR)로 6극회의 강 내조사(point "A"에 3000 to 3500cGy, 500cGy/fx, 2회/week)를 시행하였다. 방사선치료와 저용량의 cisplatin을 동시에 사용한 군에서는 방사선치료 첫날부터 방사선치료 20일째 되는 날까지 저용량의 cisplatin 10mg을 방사선치료 30분 전에 투여하였다. 급성독성의 평가는 expanded common toxicity criteria of the NCI Clinical Trial을 이용하였다. 초기반응의 평가는 방사선치료 종료이후 최소 4주이상의 추적조사가 가능한 사람들을 대상으로 시행되었다. 결과 : 급성독성 평가는 전체 38명에서 평가 가능하였으며, 방사선치료와 저용량의 cisplatin을 병용한 군에서 16명 중 6명(37.5$\%$)에서, 방사선 단독으로 치료한 군에서는 22명중 1명(6.2$\%$)에서 3등급 이상의 백혈구감소를 보였으며, 통계학적으로 의미있는 차이를 보였다 (P=0.030). 3등급 이상의 급성 위장간 독성은 저용량의 cisplatin을 병용한 군에서만 4명이 있었으나, 2-3일의 치료 중단이후 증상이 완화되어서 치료를 계속할 수 있었으며, 치료중 5kg이상의 체중감소는 방사선치료와 저용량의 cisplatin을 병용한 군에서는 16명중 3명(18.7$\%$), 방사선 단독으로 치료한 군에서는 22명중 2명(9.1$\%$)으로 통계학적으로 의미 있는 차이를 보이지 않았다(P=0.63). 초기반응은 추적조사가 4주 이상 가능하였던 34명을 대상으로 하였으며, 저용량의 cisplatin을 병용한 군에서 14명중 11명 (78$\%$), 방사선 단독으로 치료 군에서 20명중 16명(80$\%$)으로 통계학적으로는 의미있는 차이를 보이지 않았다(P=0.126). 결론 :국소 진행된 자궁경부암에 대한 방사선치료와 저용량의 cisplatin 병용요법 치료시 3등급 이상의 백혈구감소가 방사선치료 단독으로 치료시보다 많았으나, 1주 이하의 치료중단 이후 치료를 계속 할 수 있었으며, 4등급 이상의 백혈구감소와 치료에 의한 사망은 없었다. 초기반응에 대한 평가는 저용량의 cisplatin병용 군에서 4cm 이상의 자궁경부암을 가진 환자가 많음에도 불구하고 양 군에서 비슷한 정도의 반응을 보였으므로 진행된 자궁경부암의 치료에서 저용량의 cisplatin을 방사선민감제로 사용하여 치료결과의 향상을 기대할 수 있게 되었다. 따라서 저용량의 clsplatin과 방사선치료를 병용요법하였을 때의 치료효과를 판정하기 위해서는 phase III study가 필요하다.

  • PDF

비인두암의 국소 종양 치유와 생존율에 관한 예후 인자 분석 (An Analysis on Factors Affecting Local Control and Survival in Nasopharvngeal Carcinoma)

  • 정웅기;조재식;박승진;이재홍;안성자;남택근;최 찬;노영희;나병식
    • Radiation Oncology Journal
    • /
    • 제17권2호
    • /
    • pp.91-99
    • /
    • 1999
  • 목적 :비인두암 환자에서 항암화학요법과 방사선치료 후 국소종양제어율, 생졸율, 무병생존율에 미치는 예후 인자를 알아보고자 하였다. 대상 및 방법 : 1986년 7월부터 1996년 6월까지 약 10년간 전남대학교병원에서 비인두암으로 확진되어 근치적 목적으로 치료를 받은 47명의 환자를 대상으로 후향적 분석을 시행하였다. 대상 환자의 연령 분포는 16세에서 80세까지였고 중앙값은 52세였다. 성별 분포는 남자가 33명(70$\%$), 여자가 14명(30$\%$)이었다. WHO의 기준에 의한 조직학적 유형은 제1형(제라틴형성 편평세포암)이 3례(6$\%$), 제2형(비케라틴형성 편평세포암)이 30례(64$\%$), 제3형(미분화암)이 13례(28$\%$)였고 나머지 1례(2$\%$)는 조직학적 유형이 알려지지 않았다. 미국암합동위원회(1997)의 병기분류법에 따라 후향적으로 다시 분류한 병기는 71, T2a, T2b, 73, 74에서 각각 11례(23$\%$), 6례(13$\%$), 9례(19$\%$), 7례(15$\%$), 14례(30$\%$)였다. 그리고 림프절 침범 상태는 NO, Nl, N2, N3에서 각각 7례(15$\%$), 14례(30$\%$), 21례(45$\%$), 5례(l0$\%$,) 있었다. 병기군별 분포는 Stage 1, IIA, IIB, III, IVA, IVB에서 각각 2례(4$\%$), 2례(4$\%$), 10례(21$\%$), 14례(30$\%$), 14례(30$\%$), 5례(11$\%$) 있었다. 방사선치료 전에 항암제 치료를 받은 환자는 42례이며 5례는 항암제 치료가 시행되지 않았다. 방사선치료는 선형가속기의 6MV와 10MV X-ray 및 9MeV 전자선을 사용하였으며 원발 병소에 조사된 총방사선량은 6120-7920cGy(중앙값 : 7020cGy)였다. 항암화학요법 은 Cisplatin+5-Fluorouracii(25명), Cispiatin+pepleomycin(17명)으로 1회에서 3회까지 시행하였다. 국소종양제어율, 생졸율, 무병생존율을 Haplan-Meier법에 의하여 산출하였으며 두 군간의 생존율의 차이는 GeneraliBed t띤cokon test를 이용하여 검증하였다. 영향을 주는 인자의 다변량분석에는 Cox 모델을 이용하였다. 결과 : 국소종양 제어율은 2년에 89$\%$, 5년에 81$\%$이었다. 5년 생존율을 60$\%$,(범위: 6-132개월, 중앙값: 106개월)이었다. 예후에 영향을 미치는 위험 일자로 연렬, 성별, 뇌신경침범, 병리조직학적 유형, 병기군, 항암화학요법, 항암화학 요법과 방사선치료 사리의 간격, 방사선량, 방사선치료기간을 다변량분석에 포함시켰다. 국소종양제어율에는 뇌신경침범(P=0.004)만이 의의 있는 것으로 나타났다. 생존율과 무병생존율에는 병기군(P=0.006, P=0.006)과 총방사선량 (P=0.012, P=0.008)이 의의 있는 것으로 나타났다. 치료 후 합병증은 구강건조증, 치아손상, 이증상 등이 많았으며 2례의 갑상선기능저하증이 있었다. 결론 : 비인두암에서 예후에 영향을 미치는 인자로서 국소종양제어율은 뇌신경침범 여부가, 생존율 및 무병생존율에는 총방사선량과 병기군, 특히 N 병기가 의의 있는 것을 알 수 있었다. 사용된 항암화학요법과 방사선치료는 심각한 부작용이 없이 효과적으로 이용될 수 있음을 알 수 있었다.

  • PDF

국내 치과방사선의 현황 및 이용 실태 (The Actual State and the Utilization for Dental Radiography in Korea)

  • 신귀순;김유현;이보람;김세영;이귀원;박창서;박혁;장계용
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제33권2호
    • /
    • pp.109-120
    • /
    • 2010
  • 치과 X선 검사 시 환자선량의 권고량 가이드라인을 개발하기 위해서 우선 국내 치과방사 선의 현황 및 이용 실태를 설문조사하여 비교분석하였다. 응답을 받은 77곳의 치과병 의원 중에서 치과대학이 있는 치과대학병원을 A그룹(11곳), 치과대학이 없는 대학병원을 포함한 치과병원을 B그룹(30곳), 치과의원을 C그룹(36곳)으로 분류하였다. 그룹별로 분석한 결과는 다음과 같았다. 치과병 의원 한 곳당 평균 unit chairs수는 A그룹 140.2개, B그룹 15.3개, C그룹 5.8개, 평균치과의사수는 A그룹 112.6명, B그룹 7.3명, C그룹 1.7명, 평균방사선사수는 A그룹 3.1명, B그룹 0.5명, C그룹에는 한 명도 없었고, 평균치과위생사수는 A그룹 19.7명, B그룹 12.5명, C그룹 3.3명이었다. 설치된 치과용 X선장치의 평균보유수는 A그룹 14.64대, B그룹 3.21대, C그룹 2.19대로 나타났다. 이 중에서 구내촬영장치가 가장 많았고, 다음은 파노라마 장치, 세팔로 장치, CBCT 장치 순이었으며, 장치시스템의 비율은 세 그룹 모두 DR 시스템이 50% 이상으로 가장 많았다. 필름 시스템인 경우, 사용된 구내필름은 감광도가 높은 Insight 필름(Kodak, USA)이 대부분이었으며, 자동 현상기는 사용하는 곳이 적었으나, 필름유지기구는 사용하는 곳이 약간 많았다. PACS 이용률은 A그룹 90.9%, B그룹 83.3%, C그룹 16.7%이었고, 프로그램은 국내의 Infinitt에서 개발된 PiView STAR가 가장 많이 이용되고 있었다. 치과병 의원 한 곳당 2008년도의 연간 평균촬영건수는 A그룹이 B그룹보다 6.8배, C그룹보다 21.2배 더 많았으며, 구내 치근단 촬영과 파노라마 촬영이 대부분이었다. 구내 치근단 촬영 시 관전압과 관전류는 세 그룹 모두 비슷하였으나, 노출시간은 C그룹이 A그룹의 12배, B 그룹의 3.5배 정도 길었다. 즉, 대부분 치과위생사가 촬영하고 있는 C그룹에서는 방사선 노출량이 다른 그룹에 비해 훨씬 많았다. 그러나 파노라마촬영 시의 조건은 세 그룹에서 큰 차이가 없었다. 결론적으로, 촬영조건은 경험적 지식을 따르기보다는 권장량을 사용해야 하며, 필름시스템에서는 자동현상기와 필름유지기구를 사용하여 방사선의 노출량을 줄여준다. 또한 환자선량의 감소와 X선 영상의 질 향상을위해서 X선발생장치 및 관련기기의 체계적인 정도관리가 반드시 필요하다.

자궁경부암 환자에서 방사선치료 후에 발생한 직장출혈과 치료 (Rectal Bleeding and Its Management after Irradiation for Cervix Cancer)

  • 전미선;강승희;길훈종;오영택;손정혜;정혜영;유희석;이광재
    • Radiation Oncology Journal
    • /
    • 제20권4호
    • /
    • pp.343-352
    • /
    • 2002
  • 목적 : 자궁경부암의 경우 종양에 충분한 양의 방사선을 조사하기 위해서는 직장도 고선량의 방사선을 받게 된다. 이로 인해 직장염을 비롯한 만성부작용이 발생하며 직장 출혈 빈도를 $5\~30\%$ 보고하고 있다. 저자는 완치 목적의 방사선치료를 받은 자궁경부암 환자들을 대상으로 직장 출혈 빈도와 그와 관련된 위험인자들을 분석하고 치료 방법을 살펴보고자 한다. 대상 및 방법 : 1994년 9월과 1999년 12월 사이에 방사선 단독치료를 받은 213명의 자궁경부암 환자를 대상으로 하였다. 90명이 외부 방사선치료의 일부를 하루 2회씩 받았다(변형된 다분할 방사선치료). 자궁주위조직의 외부 방사선량은 총 $51\~59\;Gy$였고 근접방사선치료로 A점에 총 $28\~30\;Gy$ (4 Gy씩 7회 혹은 5 Gy씩 6회)를 조사하였다. 직장에 조사된 선량은 ICRU 38에서 정한 위치와, 모의촬영필름에서 바리움에 의해 구분되는 직장 앞쪽 벽의 한 점을 선정하여 계산하였다. 직장출혈의 정도는 LENT/SOMA에 따라 분류하였다. 추적관찰 기간은 $12\~86$개월(중앙값 39개월)이었다. 결과 : 27명$(12.7\%)$의 환자에서 직장출혈이 발생하였다(등급 2와 3:각각 16명과 2명, $8.5\%$). 이들 중에서 추적관찰 기간동안 질-직장루 또는 폐쇄로 진행된 경우는 없었다 발생시기는 대부분의 환자에서$(92.6\%)$ 치료 종료 후 2년 이내였다(중앙값 16개월). 단변량분석에서 위험인자로 icruCRBED (직장이 받은 총 생물학적 동등선량), 자궁주위조직의 방사선량, 및 병기였다. icruCRBED가 100 미만인 경우와 100 이상인 경우 $4.2\%$$19.7\%$, 자궁주위조직에 대한 조사선량 55 Gy 미만과 그 이상인 경우가 $5.1\%$$22.1\%$, 병기 II 이하인 경우와 III 이상인 경우가 $10.5\%$$31.8\%$였다. 다변량분석에서는 icruCREED 만이 유의하였다(0=0.0432). 등급 1 출혈은 자연적으로 소실되거나(3명) $1\~2$개월의 sucralfate 관장으로 멈추었다. 등급 2의 환자 6명은 $1\~2$개월 동안 sucralfate 관장으로 출혈의 빈도와 양이 줄어들었고 이 중 4명은 전기응고술을 추가로 시행하였다. 다른 9명은 전기응고술을 먼저 시행하였다(4명; sucralfate 관장 병행). 모두 $3\~10$개월 내에 정지되었다. 등급 3의 출혈은 잦은 전기응고술과 수혈을 요하였다. 결론 : 본 연구에서 중등도 이상의 직장출혈빈도가 $8.5\%$로 타 문헌에서 보고된 빈도와 유사한 결과였다. 직장에 조사된 총 생물학적 동등선량이 100 Gy 이상인 경우에 직장출혈이 유의하게 증가하므로, 치료계획시 생물학적 동등선량을 고려함으로써 휴유증 감소에 도움이 될 것으로 생각된다. 직장출혈이 발생한 환자에서 조기에 적극적으로 치료를 시행함으로써 출혈로 인한 불편함을 신속하게 해결하고 이로 인한 심리적 불안감을 해소할 수 있으며 나아가 삶의 질 향상에도 도움을 줄 수 있을 것으로 판단된다.