• Title/Summary/Keyword: BCI(Brain-Computer Interface)

Search Result 145, Processing Time 0.03 seconds

Feature extraction and Classification of EEG for BCI system

  • Kim, Eung-Soo;Cho, Han-Bum;Yang, Eun-Joo;Eum, Tae-Wan
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.260-263
    • /
    • 2003
  • EEC is an electrical signal, which occurs during information processing in the brain. These EEG signals has been used clinically, but nowadays we are mainly studying Brain-Computer Interface(BCI) such as interfacing with a computer through the EEG controlling the machine through the EEG The ultimate purpose of BCI study is specifying the EEG at various mental states so as to control the computer and machine. A BCI has to perform two tasks, the parameter estimation task, which attemps to describe the properties of the EEG signal and the classification task, which separates the different EEC patterns based on the estimated parameters. First, we have to do parameter estimation of EEG to embody BCI system. It is important to improve performance of classifier, But, It is not easy to do parameter estimation by reason of EEG is sensitivity and undergo various influences. Therefore, this research should do parameter estimation and classification of the EEG to use various analysis algorithm.

  • PDF

Parallel Model Feature Extraction to Improve Performance of a BCI System (BCI 시스템의 성능 개선을 위한 병렬 모델 특징 추출)

  • Chum, Pharino;Park, Seung-Min;Sim, Kwee-Bo
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.1022-1028
    • /
    • 2013
  • It is well knowns that based on the CSP (Common Spatial Pattern) algorithm, the linear projection of an EEG (Electroencephalography) signal can be made to spaces that optimize the discriminant between two patterns. Sharing disadvantages from linear time invariant systems, CSP suffers from the non-stationary nature of EEGs causing the performance of the classification in a BCI (Brain-Computer Interface) system to drop significantly when comparing the training data and test data. The author has suggested a simple idea based on the parallel model of CSP filters to improve the performance of BCI systems. The model was tested with a simple CSP algorithm (without any elaborate regularizing methods) and a perceptron learning algorithm as a classifier to determine the improvement of the system. The simulation showed that the parallel model could improve classification performance by over 10% compared to conventional CSP methods.

Normalization Framework of BCI-based Facial Interface

  • Sung, Yunsick;Gong, Suhyun
    • Journal of Multimedia Information System
    • /
    • v.2 no.3
    • /
    • pp.275-280
    • /
    • 2015
  • Recently brainwaves are utilized diversely in the field of medicine, entertainment, education and so on. In the case of medicine, brainwaves are analyzed to estimate patients' diseases. However, the applications for entertainments usually utilize brainwaves as control signal without figuring out the characters of the brainwaves. Given that users' brainwaves are different each other, a normalization method is essential. The traditional brainwave normalization approaches utilize normal distribution. However, those approaches assume that brainwaves are collected enough to conduct normal distribution. When the few amounts of brainwaves are measured, the accuracy of the control signal based on the measured brainwaves becomes low. In this paper, we propose a normalization framework of BCI-based facial interfaces for novel volume controllers, which can normalizes the few amounts of brainwaves and then generates the control signals of BCI-based facial interfaces. In the experiments, two subjects were involved to validate the proposed framework and then the normalization processes were introduced.

A Study on EEG based Concentration Transmission and Brain Computer Interface Application (뇌파기반 집중도 전송 및 BCI 적용에 관한 연구)

  • Lee, Chung-Heon;Kwon, Jang-Woo;Kim, Gyu-Dong;Hong, Jun-Eui;Shin, Dae-Seob;Lee, Dong-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.2
    • /
    • pp.41-46
    • /
    • 2009
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We develop concentration wireless transmission system for controlling hardware by using this signal. Two channels are used for measuring EEG signal on front head and Biopac system with MP100 and EEG100C was used for measuring EEG signal, amplifying and filtering the signal. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the measured EEG signals. As a result, SMR wave, Mid-Bata wave, $\Theta$ wave classified. We extracted the concentration index by adapting concentration extraction algorithm. This concentration uldex was transferred into logo automobile device by wireless module and applied for BCI application.

An Implementation of Brain-wave DB building system for Artifacts prevention using Face Tracking (얼굴 추적 기반의 잡파 혼입 방지가 가능한 뇌파 DB구축 시스템 구현)

  • Shin, Jeong-Hoon;Kwon, Hyeong-Oh
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.10 no.1
    • /
    • pp.40-48
    • /
    • 2009
  • Leading of the computer, IT technology has make great strides. As a information-industry-community was highly developed, user's needs to convenience about intelligence and humanization of interface is being increase today. Nowadays, researches with are related to BCI are progress put the application-technology development first in importance eliminating research about fountainhead technology with DB construction. These problems are due to a BCI-related research studies have not overcome the initial level, and not toward a systematic study. Brain wave are collected from subjects is a signal that the signal is appropriate and necessary in the experiment is difficult to distinguish. In addition, brain wave that it's not necessary to collect the experiment, serious eyes flicker, facial and body movements of an EMG and electrodes attached to the state, noise, vibration, etc. It is hard to collect accurate brain wave was caused by mixing disturbance wave in experiment on the environment. This movement, and the experiment of subject impact on the environment due to the mixing disturbance wave can cause that lowering cognitive and decline of efficiency when embodied BCI system. Therefore, in this paper, we propose an accurate and efficient brain-wave DB building system that more exactness and cognitive basis studies when embodied BCI system with brain-wave. For the minimize about brain wave DB with mixing disturbance, we propose a DB building method using an automatic control and prevent unnecessary action, put to use the subjects face tracking.

  • PDF

Psychology analyzing system using spectrum component density ratio of EEG based on BCI-TAT (EEG 대역별 스펙트럼 활성 비를 활용한 BCI-TAT 기반 심리 분석 시스템)

  • Shin, Jeon-Hoon;Jin, Sang-Hyeon
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.2
    • /
    • pp.112-124
    • /
    • 2010
  • Studies that can find resolutions to problems of subjective psychiatric analysis must be performed and indeed they are in the process. However there still lies many problems in researches of mentality examination, which should be the foundation of finding potential resolutions. One of the biggest problems in the conventional system is that there are many different opinions by psychiatrists depending on their educations and experiences. There is no objective standard on the subjects and there is no effective psychiatric analysis method. Also, the characteristic of such examinations is that it cannot be applied to disabilities, foreigners and infants alyce the examination is ch examinconversation. The objective of this atudy is to standardize TAT(Thematic Apperception Test)analysiBallken index method so that subjective data from the examination can be excluded and the examination thus maklysithe examination objectified. Furthermore, objective result and patients' brain wave pattern is read with BCI(Brain Computer Interface) ch exaTherenvironment to Alsare it to brain wave characteristics vectors to reate brain-wave characteristics vector DB. Therefore, such DB can be utilize durlysithe examination and diagnosis to reate objective examination method and standardized diagnosis system. Thus, mentality examination can be performed only with brain-wave scans with BCI based TAT system.

Motor Imagery Brain Signal Analysis for EEG-based Mouse Control (뇌전도 기반 마우스 제어를 위한 동작 상상 뇌 신호 분석)

  • Lee, Kyeong-Yeon;Lee, Tae-Hoon;Lee, Sang-Yoon
    • Korean Journal of Cognitive Science
    • /
    • v.21 no.2
    • /
    • pp.309-338
    • /
    • 2010
  • In this paper, we studied the brain-computer interface (BCI). BCIs help severely disabled people to control external devices by analyzing their brain signals evoked from motor imageries. The findings in the field of neurophysiology revealed that the power of $\beta$(14-26 Hz) and $\mu$(8-12 Hz) rhythms decreases or increases in synchrony of the underlying neuronal populations in the sensorymotor cortex when people imagine the movement of their body parts. These are called Event-Related Desynchronization / Synchronization (ERD/ERS), respectively. We implemented a BCI-based mouse interface system which enabled subjects to control a computer mouse cursor into four different directions (e.g., up, down, left, and right) by analyzing brain signal patterns online. Tongue, foot, left-hand, and right-hand motor imageries were utilized to stimulate a human brain. We used a non-invasive EEG which records brain's spontaneous electrical activity over a short period of time by placing electrodes on the scalp. Because of the nature of the EEG signals, i.e., low amplitude and vulnerability to artifacts and noise, it is hard to analyze and classify brain signals measured by EEG directly. In order to overcome these obstacles, we applied statistical machine-learning techniques. We could achieve high performance in the classification of four motor imageries by employing Common Spatial Pattern (CSP) and Linear Discriminant Analysis (LDA) which transformed input EEG signals into a new coordinate system making the variances among different motor imagery signals maximized for easy classification. From the inspection of the topographies of the results, we could also confirm ERD/ERS appeared at different brain areas for different motor imageries showing the correspondence with the anatomical and neurophysiological knowledge.

  • PDF

Discrimination of EEG Signal about left and right Motor Imagery (왼쪽과 오른쪽 움직임의 상상에 대한 뇌파의)

  • 음태완;김응수
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2004.10a
    • /
    • pp.373-376
    • /
    • 2004
  • 최근에 뇌파를 이용하여 컴퓨터와 통신하거나 기기를 제어할 수 있는 이른바 뇌-컴퓨터 인터페이스BCI(Brain-Computer Interface)에 대한 연구가 대두되고 있다. 이러한 BCI 연구의 궁극적 목표는 다양한 정신상태에 따른 뇌파의 특성을 파악하여 컴퓨터나 기기 등을 제어하는 것이다. 본 논문에서는 움직임과 관련 있는 10~12Hz의 mu파 영역에서의 ERD/ERS를 계산하였고, 그 결과 왼쪽과 오른쪽 손의 움직임을 상상할 때에 운동과 관련된 기능이 집중되어 있는 일차운동영역(primary motor area)의 mu파에서 ERD/ERS의 차이가 나타남을 발견하였다 또한, RLS방법을 사용한 Adaptive Autoregressive Model 계수의 특징을 추출을 하였으며, 이를 신경망으로 학습시켜 인식률을 비교하였다.

  • PDF

Human Emotion Recognition Method using EEG Signals by Bayesian Networks (Bayesian Networks 이용한 EEG 신호에서의 사람의 감정인식 방법 개발)

  • Kim, Ho-Duck;Sim, Kwee-Bo
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2008.04a
    • /
    • pp.151-154
    • /
    • 2008
  • 본 논문은 Bayesian Networks를 이용해서 EEG 신호를 분석해서 사람의 감정을 분석하는 방법을 제안하였다. 현제 연구자들은 Electroencephalogram(EEG) 신호를 기반으로 사람의 두뇌와 컴퓨터의 인터페이스에 관한 연구를 하고 있다. 기존에는 간질이나 발작 등을 의학 분야와 사람의 정서에 따라 뇌파분석을 하는 심리학의 영역에서 연구가 되어져 왔다. 최근에는 사람의 두뇌와 컴퓨터 간의 인터페이스를 통한 여러 가지 공학적인 접근이 이루어지고 있다. 본 논문에서는 사람의 감정에 따라 Brain-Computer Interface (BCI)를 통해서 EEG 신호를 분석하고 잡음을 제거해서 보다 정확한 신호를 추출한 다음 각각의 주파수 영역으로 분류를 하였다. 분류된 값들은 Bayesian Networks를 이용해서 피 실험자가 어떠한 감정을 나타내는지 확률 값으로 나타낸다. 확률 값에 의해서 피 실험자가 어떠한 감정인지를 인식하게 되는 것이다.

  • PDF

A Study on EEG based Concentration transmission and Brain Computer Interface Application (뇌파기반 집중도 전송 및 BCI 적용에 관한 연구)

  • Lee, Chung-Heon;Kwon, Jang-Woo;Kim, Gyu-Dong;Lee, Jun-Oh;Hong, Jun-Eui;Lee, Dong-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.155-156
    • /
    • 2008
  • This research measures EEG signals which are generating on head skin and extracts brain concentration level related with brain activity. We develop concentration wireless transmission system for controlling hardware by using this signal. Two channels are used for measuring EEG signal on front head and Biopac system with MP-100 and EEG100C was used for measuring EEG signal, amplifying and filtering the signal. LabView 8.5 was also used for FFT transformation, frequency and spectrum analysis of the measure EEG signal. As a result, ${\alpha}$ wave, ${\beta}$ wave, ${\theta}$ wave and ${\delta}$ wave were classified. we extracted the concentration index by adapting concentration extraction algorithm. This concentration index was transferred into lego automobile device by wireless module and applied for BCI application.

  • PDF