• Title/Summary/Keyword: BAS-2

Search Result 144, Processing Time 0.024 seconds

Effect of Acupuncture H8(Sobu, Fire Property), H3(Sohae, Water Property) on Skin Temperature of H1(Sochung, Heart Meridian) (수소음심경(手少陰心經)의 형화혈(滎火穴) 소부(少府), 합수혈(合水穴) 소해(少海) 침자(鍼刺)가 소충(少衝) 부위(部位) 체표온도(體表溫度)에 미치는 영향(影響))

  • Youn Dae-Hwan;Park Jun-Sung;Na Chang-Su
    • Korean Journal of Acupuncture
    • /
    • v.19 no.2
    • /
    • pp.35-39
    • /
    • 2002
  • Objective : The purpose of this study was to investigate the Effect of Acupuncture Stimulation of Sohae(H3) and Sobu(H8) Acupoint on Skin Temperature of Sochung Acupint(H9, the end acupoint of Heart Meridian). Sohae and Sobu acupoint has a property of water and fire in the Five agents on Heart Meridian. Methods : Subjects were four healthy oriental medical students volunteers(male, mean age-28). One group(two subjects) received acupuncture on Sohae acupoint(H3) and the other group(two subjects) on Sobu acupoint(H8) while resting. Skin temperature was measured on Sochung acupoint(H9) before, during, and after acupunture stimulation. Each test took 15minutes. The initial 5minutes were definded as BAS(Before Acupuncture Stimulation) period, the following 5minutes as DAS(During Acupuncture Stimulation) period, the last 5minutes as AAS(After Acupuncture Stimulation) period. This test was performed twice in order to increase the statistical authenticity. Results : Our result indicates that acupuncrue stimulation of Sohae acupoint(H3) decreased and Sobu acupoint(H8) increased skin temperature on Sochung acupoint(H9) in the DAS period. The changes remained throughout the AAS period. Our conculusion are that stimulaton of the Water and Fire property-acupoint(H3, H8) on Heart changes the skin temperature on Sochung acupoint on the same Heart Meridian. However this study has no authenticity because it had no regard for many factors effecting on the result and the result of the study was the very reverse of our expectation.

  • PDF

A study on the series-fed microstrip array anteena with coupling-slots (슬롯결합구조를 갖는 직렬급전 마이크로스트립 배열 안테나에 관한 연구)

  • 장병준;김덕수;문호원;윤영중;박한규
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.2
    • /
    • pp.495-504
    • /
    • 1996
  • In this paper, series-fed mirostrip array anteenas with coupling-slots are prposed and their operating characteristics are analyzed based on analyzed based on analytical and experimental results. An accurate analysis method for the slot-coupled feed structure is based on using both circuit coupling between anteenas and full-wave analysis which use travling wave mode and non-traveling wave mode on feed line. The basis functions that used for the numerical analysis bas been determined depending upon the accuracy, convergence properties of the solution, and the computation time:The patch uses 3 EB mode, the slot uses 1PWS mode, and feeders use 5 PWS mode. Series-fed array antennas have been designed, built, and tested in a standing-wave configuration. Using the results of the full-wave analysis, the chebyshev array antennas consisting of 8 elements are designed and fabricated changing the amount excited to each array element by adjusting slot length and by the slot position relative to the feeder. Experiment results show that the series-fed array antenna designed by adjusting the slot position relative to the feeder is superior to that designed by slot length.

  • PDF

A Clinical Study of Acute Low Back Pain Patients in Muscular Origin Through Symptom Check List-90-Revision(SCL-90-R) (급성 근육기인성 요배부 통증환자에 대한 간이정신진단검사를 통한 고찰)

  • Lee, Kang-Su
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.1 no.1
    • /
    • pp.1-14
    • /
    • 2006
  • Objectives : The causative pathology of acute muscular pain cannot be defined in many patients. To evaluate the relations between mental state and acute muscular pain patients, the author surveyed symptom check list-90-Revision(SCL-90-R) in patients with acute muscular pain. Materials and Methods : From November 2004 to June 2005, a questionnaire including SCL-90-R was given to patients(52 persons) who visited our department for acute(<7days)muscular pain of neck(22 persons) or low back(30 persons). Fifty two patients(30 male, 22 female) completed SCL-90-R Results : 1. Mean values of T-scores on all 9 basic scales in the patients groups were within normal range. but T-scores SOM in the patients groups were significantly very higher than those in Normal groups(p<0.01). 2. The T-scores of SOM In low back pain patients were significantly higher than those in Normal groups(p<0.05). 3. There was no significant difference in all scales between acute muscular pain and L-spine HIVD patients groups. 4. There was no significant difference in all scales between acute muscular pain and general back pain patients groups. 5. There was no significant difference in all scales between male and female in the patients groups. Conclusion : It is concerned between T-scores on all 9 bas κ scales of SCL-90-R and acute muscular pain. Especially acute muscular pain of back has a relation to somatization of T-scores on all 9 basic scales of SCL-90-R.

  • PDF

Methane-Steam Reforming Simulation for a High Temperature Solar Chemical Reactor (고온 태양열 화학 반응기에서의 메탄-수증기 개질반응 시뮬레이션)

  • Ko, Jo-Han;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Steam reforming of methane in the high temperature solar chemical reactor bas advantage in its heating method. Using concentrated solar energy as a heating source of the reforming reaction can reduce the $CO_2$ emission by 20% compared to hydrocarbon fuel. In this paper, the simulation result of methane-steam reforming on a high temperature solar chemical reactor(SCR) using Fluent 6.3.26 is presented. The high temperature SCR is designed for the Inha Dish-1, a Dish type solar concentrator installed in Songdo city. Basic SCR performance factors are referred to the former researches of the same laboratory. Inside the SCR porous metal is used for a receiver/reactor. The porous metal is carved like a dome shape on the incident side to increase the heat transfer. Also, ring-disc set of baffle is inserted in the porous metal region to increase the path length. Numerical and physical models are also used from the former researches. Methane and steam is mixed with the same mole fraction and injected into the SCR. The simulation is performed for a various inlet mass flow rate of the methane-steam mixture gas. The result shows that the average reactor temperature and the conversion rate change appreciably by the inlet mass flow rate of 0.0005 kg/s.

Survey of Biogenic Amine Contents in Commercial Soy Sauce (시판 간장 중의 biogenic amine의 함량 조사)

  • Kim, Jae-Hyun;Park, Hyun-Jin;Kim, Mi-Jung;Ahn, Hyun-Joo;Byun, Myung-Woo
    • Korean Journal of Food Science and Technology
    • /
    • v.35 no.2
    • /
    • pp.325-328
    • /
    • 2003
  • Nine commercial soy sauces $(A{\sim}I)$ were investigated for their biogenic amine (BAs) levels. Detected biogenic amines were putrescine (PUT), cadaverine (CAD), trytamine (TRP), ${\beta}-phenylethylamine$ (PHE), spermine (SPM), histamne (HIS), and tyramine (TYR). All products tested had biogenic amines as detected level. PUT was the major biogenic amines detected in six products, and difference between the highest and the lowest among products was more than 16 mg/kg. Six products had all seven biogenic amines tested, while one product had only five. Results indicate that soy sauces commercially available in Korea contain biogenic amines at various levels. Studies related to biogenic amines including survey of contents must be performed continuously.

The Relationship among Fun Seeking, Self-Efficacy, Interest in Physical Activity and Actual Physical Activity of Male College Students (남자 대학생들의 재미추구 성향, 자기효능감 및 운동에 대한 흥미와 운동량 간의 관계)

  • Suh, Kyung-Hyun
    • Korean Journal of Health Education and Promotion
    • /
    • v.25 no.1
    • /
    • pp.1-12
    • /
    • 2008
  • Objectives: The researchers investigated the relationship among fun seeking, self-efficacy, interest in physical activity and actual physical activities of male college students, in orders to provide valuable information to professionals in health promotion. Methods: The participants were 316 male college students whose ages ranged from 18 to 30(M=22.53, SD=2.09). The questionnaires and psychological tests used in this research included the following: sub-scale of Korean Version of BAS/BIS Scale, The General Self-Efficacy Scale, International Physical Activity Questionnaires, & sub-scale of The Intrinsic Motivation Inventory for physical activity. Results: Results indicated that male students who had moderate level of fun seeking were more likely to engage in physical activities than those who showed low or high level of fun seeking. And students with the strong self-efficacy were more likely to do physical activity than with the weak self-efficacy, especially high level of physical activity. Male students who had greater interest in physical activity were more likely to engage in physical activities than those who were not interested in physical activity. A regression analysis revealed that interest in physical activity accounted for the most variance; it accounted for around 14.5% variance of actual physical activity with self-efficacy. The interaction effect of self-efficacy and interest in physical activity was significant for actual physical activity. Conclusion: This study reiterates the roles of self-efficacy and the interest in physical activity on physical activity, and found that non-linear relation of fun seeking to physical activity. These results may provide useful information for health practitioners.

A STUDY ON THE BONDING STRENGTH OF RESILIENT DENTURE LINERS (탄성 의치상 이장재의 접착력에 관한 연구)

  • Lee Sang-Hoon;Chung Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.3
    • /
    • pp.411-436
    • /
    • 1992
  • The purpose of this study was to assess the adhesion of resilient denture liners (such as, heat-cured silicone molloplast B,cold- cured silicone Mollosil) to polymethyl metacrylate (K-33) and metal (Megalloy) in the laboratory by peel test. The resilient denture lines were processed according to manufactures instruction, onto prepared specimens(original resin base plate, rough resin base plate, stippled metal plate, mesh metal plate ) 75mm long and 25m wide. And then, the peel test was performed by instron. The results were as follows : 1. The bonding strength of Mollosil was stronger than that of Molloplast B except the specimen of stippled metal plate. 2. The tensile strength of Mollosil was weaker than that of Molloplast Bas tearing of Mollosil was occured in the peel test. 3. Mesh metal plate had the highest bonding strength in the case of Molloplast B and Mollosil. But stippled metal plate have high bonding strength in the case of Molloplast B and have the lowest bonding strength in the case of Mollosil. 4. The bonding strength of rough resin base plate was stronger than that of original resin base plate in the case of Molloplast B and Mollosil. 5. The bonding strength of metal plates was stronger than that of resin base plates in the case of Molloplast B and Mollosil except the case of bonding strength between the stippled metal plate and Mollosil. 6. It seems that the Increase of surface and retention form of metal plate and resin base plate produces higher physical bonding strength.

  • PDF

Design and Implementation of Mobile ]Respiration Detection Diagnostic System using Ultrasound Sensing Method fficient Multicasting Environment (초음파 센싱 방식을 이용한 이동형 호흡량 측정 진단기의 설계 및 구현)

  • 김동학;김영길
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.8 no.2
    • /
    • pp.509-515
    • /
    • 2004
  • Pulmonary function tests are widely used to diagnose and determine patients' therapy in clinic. And it was also applied in the research of the physiology and dynamics for lung disease. Among the pulmonary function tests, spirometry is the most easy and economic test. Spirometers are medical instruments that measure the instantaneous rate of volume flow of respired Bas. The mechanical spirometer was mostly used in the past. Up to the present, the most popular method of spirometer is the differential pressure technique with which change in the volume of flow are transferred to change in pressure. This kind of instrument suffers from several limitations, pressure drop, difficulty in maintenance and short period of calibration. Therefore, this study has begun to implement ultrasound spirometer, which is free of pressure loss and has wide range, focusing on the flow measurement technique and diagnostic algorithm.

De-Centralized Information Flow Control for Cloud Virtual Machines with Blowfish Encryption Algorithm

  • Gurav, Yogesh B.;Patil, Bankat M.
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.12
    • /
    • pp.235-247
    • /
    • 2021
  • Today, the cloud computing has become a major demand of many organizations. The major reason behind this expansion is due to its cloud's sharing infrastructure with higher computing efficiency, lower cost and higher fle3xibility. But, still the security is being a hurdle that blocks the success of the cloud computing platform. Therefore, a novel Multi-tenant Decentralized Information Flow Control (MT-DIFC) model is introduced in this research work. The proposed system will encapsulate four types of entities: (1) The central authority (CA), (2) The encryption proxy (EP), (3) Cloud server CS and (4) Multi-tenant Cloud virtual machines. Our contribution resides within the encryption proxy (EP). Initially, the trust level of all the users within each of the cloud is computed using the proposed two-stage trust computational model, wherein the user is categorized bas primary and secondary users. The primary and secondary users vary based on the application and data owner's preference. Based on the computed trust level, the access privilege is provided to the cloud users. In EP, the cipher text information flow security strategy is implemented using the blowfish encryption model. For the data encryption as well as decryption, the key generation is the crucial as well as the challenging part. In this research work, a new optimal key generation is carried out within the blowfish encryption Algorithm. In the blowfish encryption Algorithm, both the data encryption as well as decryption is accomplishment using the newly proposed optimal key. The proposed optimal key has been selected using a new Self Improved Cat and Mouse Based Optimizer (SI-CMBO), which has been an advanced version of the standard Cat and Mouse Based Optimizer. The proposed model is validated in terms of encryption time, decryption time, KPA attacks as well.

An Operation Status Analysis of Library Building using BEMS Data; Energy Performance Evaluation on Initial Stage of Completion (BEMS 데이터를 활용한 도서관 건물의 운전현황 분석 -준공 초기단계의 건물 에너지 성능 평가)

  • Park, Seong-cheol;Ha, Ju-wan;Kim, Hwan-yong;Song, Young-hak
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.669-679
    • /
    • 2018
  • Energy consumption savings in buildings should be reviewed in diverse areas such as air conditioning system and lighting responsible for cooling and heating, and energy management systems such as BAS (Building Automation System) and BEMS (Building Energy Management System) are introduced to improve energy consumption efficiency and to promote economic control of related facilities by integrated management of energy generated and consumption in buildings. The measured building of this study uses regenerative geothermal system. Measured values of heat pump and system COP were 4.7 and 4.2 respectively, and they were found to be higher 11.9% and 23.5% than rated values. As a result of analyzing the air conditioning and lighting energy from the first floor to the fourth floor performing the air conditioning, the second and third floors, which have a high frequency of use, are compared with the first and fourth floors 50% higher energy consumption ratio. On the other hand, the general heat storage system uses the nighttime power of the previous day to store heat and use it the next day. The total number of days of abnormal operation during the summer season is 61 days. The electricity cost corresponding to the abnormal operation is 1,840,641 KRW, and the normal operation using the nighttime power is 1,363,561 KRW, which is difference of 477,080 KRW, 35% increase in cost. We will utilize it as the main data of BEMS through analysis of winter operation characteristics as well as summer operation characteristics.