• Title/Summary/Keyword: B-scan

검색결과 419건 처리시간 0.024초

Rigorous Modeling of the First Generation of the Reconnaissance Satellite Imagery

  • Shin, Sung-Woong;Schenk, Tony
    • 대한원격탐사학회지
    • /
    • 제24권3호
    • /
    • pp.223-233
    • /
    • 2008
  • In the mid 90's, the U.S. government released images acquired by the first generation of photo reconnaissance satellite missions between 1960 and 1972. The Declassified Intelligent Satellite Photographs (DISP) from the Corona mission are of high quality with an astounding ground resolution of about 2 m. The KH-4A panoramic camera system employed a scan angle of $70^{\circ}$ that produces film strips with a dimension of $55\;mm\;{\times}\;757\;mm$. Since GPS/INS did not exist at the time of data acquisition, the exterior orientation must be established in the traditional way by using control information and the interior orientation of the camera. Detailed information about the camera is not available, however. For reconstructing points in object space from DISP imagery to an accuracy that is comparable to high resolution (a few meters), a precise camera model is essential. This paper is concerned with the derivation of a rigorous mathematical model for the KH-4A/B panoramic camera. The proposed model is compared with generic sensor models, such as affine transformation and rational functions. The paper concludes with experimental results concerning the precision of reconstructed points in object space. The rigorous mathematical panoramic camera model for the KH-4A camera system is based on extended collinearity equations assuming that the satellite trajectory during one scan is smooth and the attitude remains unchanged. As a result, the collinearity equations express the perspective center as a function of the scan time. With the known satellite velocity this will translate into a shift along-track. Therefore, the exterior orientation contains seven parameters to be estimated. The reconstruction of object points can now be performed with the exterior orientation parameters, either by intersecting bundle rays with a known surface or by using the stereoscopic KH-4A arrangement with fore and aft cameras mounted an angle of $30^{\circ}$.

펄스길이에 따른 이중편파변수의 민감도 분석 (Sensitivity Analysis of Polarimetric Observations by Two Different Pulse Lengths of Dual-Polarization Weather Radar)

  • 이정은;정성화;김종성;장근일
    • 대기
    • /
    • 제29권2호
    • /
    • pp.197-211
    • /
    • 2019
  • The observational sensitivity of dual-polarization weather radar was quantitatively analyzed by using two different pulse widths. For this purpose, test radar scan strategy which consisted of consecutive radar scan using long (LP: $2{\mu}s$) and short (SP: $1{\mu}s$) pulses at the same elevation angle was employed. The test scan strategy was conducted at three operational S-band dual-polarization radars (KSN, JNI, and GSN) of Korea Meteorological Administration (KMA). First, the minimum detectable reflectivity (MDR) was analyzed as a function of range using large data set of reflectivity ($Z_H$) obtained from JNI and GSN radars. The MDR of LP was as much as 7~22 dB smaller than that of SP. The LP could measure $Z_H$ greater than 0 dBZ within the maximum observational range of 240 km. Secondly, polarimetric observations and the spatial extent of radar echo between two pulses were compared. The cross-polar correlation coefficient (${\rho}_{hv}$) from LP was greater than that from SP at weak reflectivity (0~20 dBZ). The ratio of $Z_H$ (> 0 dBZ) and ${\rho}_{hv}$(> 0.95) bin to total bin calculated from LP were greater than those from SP (maximum 7.1% and 13.2%). Thirdly, the frequency of $Z_H$ (FOR) during three precipitation events was analyzed. The FOR of LP was greater than that of SP, and the difference in FOR between them increased with increasing range. We conclude that the use of LP can enhance the sensitivity of polarimetric observations and is more suitable for detecting weak echoes.

폐결핵치료전후(肺結核治療前後) 방사성동위원소(放射性同位元素)스캔에 의(依)한 폐기능(肺機能)의 비교(比較) (A Dual Lung Scan for the Evaluation of Pulmonary Function in Patients with Pulmonary Tuberculosis before and after Treatment)

  • 이종헌
    • 대한핵의학회지
    • /
    • 제1권2호
    • /
    • pp.1-25
    • /
    • 1967
  • In 20 normal cases and 39 pulmonary tuberculosis cases, regional pulmonary arterial blood flow measurements and lung perfusion scans by $^{131}I$-Macroaggregated albumin, lung inhalation scans by colloidal $^{198}Au$ and spirometries by respirometer were done at the Radiological Research Institute. The measured lung function tests were compared and the results were as the following: 1. The normal distribution of pulmonary blood flow was found to be $54.5{\pm}2.82%$ to the right lung and $45.5{\pm}2.39%$ to the left lung. The difference between the right and left pulmonary arterial blood flow was significant statistically (p<0.01). In the minimal pulmonary tuberculosis, the average distribution of pulmonary arterial blood flow was found to be $52.5{\pm}5.3%$ to the right lung and $47.5{\pm}1.0%$ to the left lung when the tuberculous lesion was in the right lung, and $56.2{\pm}4.4%$ to the right lung and $43.8{\pm}3.1%$ to the left lung when the tuberculous lesion was in the left lung. The difference of pulmonary arterial blood flow between the right and left lung was statistically not significant compared with the normal distribution. In the moderately advanced pulmonary tuberculosis, the average distripution of pulmonary arterial blood flow was found to be $26.9{\pm}13.9%$ to the right lung and $73.1{\pm}13.9%$ to the left lung when the tuberculous lesion was more severe in the right lung, and $79.6{\pm}12.8%$ to the right lung and $20.4{\pm}13.0%$ to the left lung when the tuberculous lesion was more severe in the left lung. These were found to be highly significant statistically compared with the normal distribution of pulmonary arterial blood flow (p<0.01). When both lungs were evenly involved, the average distribution of pulmonary arterial blood flow was found to be $49.5{\pm}8.01%$ to the right lung and $50.5{\pm}8.01%$ to the left lung. In the far advanced pulmonary tuberculosis, the average distribution of pulmonary arterial blood flow was found to be $18.5{\pm}11.6%$ to the right lung and $81.5{\pm}9.9%$ to the left lung when the tuberculous lesion was more severe in the right lung, and $78.2{\pm}8.9%$ to the right lung and $21.8{\pm}10.5%$ to the left lung when the tuberculous lesion was more severe in the left lung. These were found to be highly significant statistically compared with the normal distribution of pulmonary arterial blood flow (p<0.01). When both lungs were evenly involved the average distribution of pulmonary arterial blood flow was found to be $56.0{\pm}3.6%$ to the right lung and $44.0{\pm}3.2%$ to the left lung. 2. Lung perfusion scan by $^{131}I$-MAA in patients with pulmonary tuberculosis was as follows: a) In the pretreated minimal pulmonary tuberculosis, the decreased area of pulmonary arterial blood flow was corresponding to the chest roentgenogram, but the decrease of pulmonary arterial blood flow was more extensive than had been expected from the chest roentgenogram in the apparently healed minimal pulmonary tuberculosis. b) In the pretreated moderately advanced pulmonary tuberculosis, the decrease of pulmonary arterial blood flow to the diseased area was corresponding to the chest roentgenogram, but the decrease of pulmonary arterial blood flow was more extensive in the treated moderately advanced pulmonary tuberculosis as in the treated minimal pulmonary tuberculosis. c) Pulmonary arterial blood flow in the patients with far advanced pulmonary tuberculosis both before and after chemotherapy were almost similar to the chest roentgenogram. Especially the decrease of pulmonary arterial blood flow to the cavity was usually greater than had been expected from the chest roentgenogram. 3. Lung inhalation scan by colloidal $^{198}Au$ in patients with pulmonary tuberculosis was as follows: a) In the minimal pulmonary tuberculosis, lung inhalation scan showed almost similar decrease of radioactivity corresponding to the chest roentgenogram. b) In the moderately advanced pulmonary tuberculosis the decrease of radioactivity in the diseased area was partly corresponding to the chest roentgenogram in one hand and on the other hand the radioactivity was found to be normally distributed in stead of tuberculous lesion in the chest roentgenogram. c) In the far advanced pulmonary tuberculosis, lung inhalation scan showed almost similar decrease of radioactivity corresponding to the chest roentgenogram as in the minimal pulmonary tuberculosis. 4. From all these results, it was found that the characteristic finding in pulmonary tuberculosis was a decrease in pulmonary arterial blood flow to the diseased area and in general decrease of pulmonary arterial blood flow to the diseased area was more extensive than had been expected from the chest roentgenogram, especially in the treated group. Lung inhalation scan showed almost similar distribution of radioactivity corresponding to the chest roentgenogram in minimal and far advanced pulmonary tuberculosis, but there was a variability in the moderately advanced pulmonary tuberculosis. The measured values obtained from spirometry were parallel to the tuberculous lesion in chest roentgenogram.

  • PDF

Thermodynamic Analysis of the Low- to Physiological-Temperature Nondenaturational Conformational Change of Bovine Carbonic Anhydrase

  • Hollowell, Heather N.;Younvanich, Saronya S.;McNevin, Stacey L.;Britt, B. Mark
    • BMB Reports
    • /
    • 제40권2호
    • /
    • pp.205-211
    • /
    • 2007
  • The stability curve - a plot of the Gibbs free energy of unfolding versus temperature - is calculated for bovine erythrocyte carbonic anhydrase in 150 mM sodium phosphate (pH = 7.0) from a combination of reversible differential scanning calorimetry measurements and isothermal guanidine hydrochloride titrations. The enzyme possesses two stable folded conformers with the conformational transition occurring at ~30$^{\circ}C$. The methodology yields a stability curve for the complete unfolding of the enzyme below this temperature but only the partial unfolding, to the molten globule state, above it. The transition state thermodynamics for the low- to physiological-temperature conformational change are calculated from slow-scan-rate differential scanning calorimetry measurements where it is found that the free energy barrier for the conversion is 90 kJ/mole and the transition state possesses a substantial unfolding quality. The data therefore suggest that the x-ray structure may differ considerably from the physiological structure and that the two conformers are not readily interconverted.

연축전지 양극기판의 기계적 특성비교 분석 및 비 파괴 평가기법의 적용 (Material Evaluation of Lead Die-Casted Positive Grid for Battery Using Nondestructive Evaluation Technique)

  • 김희중;이민래;이준현
    • 대한기계학회논문집A
    • /
    • 제26권8호
    • /
    • pp.1709-1718
    • /
    • 2002
  • It is well recognized that improving capacity of positive grid in battery is one of key factors for controlling the expected long lift-time of Battery Energy Storage System(B.E.S.S). Thus it is really important to characterized material properties of positive grid which are mainly affected by fabrication process. In this study, two kinds of positive grids, which were fabricated by gravity casting and die-casting technique were used. Micro-structural observation and tensile test were conducted to investigate the effect of fabrication process of positive grid. Ultrasonic measurement based on pulse-echo method and ultrasonic C-scan technique also performed to correlate ultrasonic velocity with porosity ratio in positive grid. It was found that the porosity ratio of grid fabricated by gravity casting technique increased significantly compared to the grid fabricated by die-casting technique. It was also shown that ulrasonic technique is effective to evaluate the porosity ratio in positive grid.

Precipitation of Eu3+ - Yb3+ Codoped ZnAl2O4 Nanocrystals on Glass Surface by CO2 Laser Irradiation

  • Bae, Chang-hyuck;Lim, Ki-Soo;Babu, P.
    • Current Optics and Photonics
    • /
    • 제2권1호
    • /
    • pp.79-84
    • /
    • 2018
  • We present a novel and simple method to enable spatially selective $ZnAl_2O_4$ nanocrystal formation on the surface of $B_2O_3$-$Al_2O_3$-ZnO-CaO-$K_2O$ glass by employing localized laser heating. Optimized precipitation of glass-ceramics containing nanocrystals doped with $Eu^{3+}$ and $Yb^{3+}$ ions was performed by controlling $CO_2$ laser power and scan speed. Micro-x-ray diffraction and transmission electron microscopy revealed the mean size and morphology of nanocrystals, and energy dispersive x-ray spectroscopy showed the lateral distribution of elements in the imaged area. Laser power and scan speed controled annealing temperature for crystalization in the range of 1.4-1.8 W and 0.01-0.3 mm/s, and changed the size of nanocrystals and distribution of dopant ions. We also report more than 20 times enhanced downshift visible emission under ultraviolet excitation, and 3 times increased upconversion emission from $Eu^{3+}$ ions assisted by efficient sensitizer $Yb^{3+}$ ions in nanocrystals under 980 nm excitation. The confocal microscope revealed the depth profile of $Eu^{3+}$ ions by showing their emission intensity variation.

Atlantooccipital assimilation associated with combined atlas arch defect: a radiological case report

  • Athikhun Suwannakhan;Pannawat Trerattanavong;Laphatrada Yurasakpong;Woranan Kirisattayakul;Nutmethee Kruepunga;Kiarttiyot Tuntiseranee;Kanitin Rumpansuwon;Thanyaporn Senarai
    • Anatomy and Cell Biology
    • /
    • 제57권3호
    • /
    • pp.468-472
    • /
    • 2024
  • In this report, atlantooccipital assimilation (AS), anterior arch defect (AAD), and posterior arch defect (PAD) of the atlas, and several variations around the craniocervical junction were identified on computed tomography (CT) of a patient of unknown sex and age. Coronal and sagittal CT scans showed AS and bilateral fusion of the atlas and the base of occipital bone. Axial CT scan at the atlas revealed PAD type B on the left side and midline AAD. Morphometric measurements indicated a potential ventral spinal cord compression. In addition, mid-sagittal CT revealed the presence of fossa navicularis magna and incomplete formation of the transverse foramen on the right side. This study reports an extremely rare AS associated with AAD, PAD, and other variations of the clivus and the atlas. To our knowledge, no similar case has been reported in the literature.

PLC 출력 구동을 위한 Wired Logic for Type Unit에 관한 연구 (A Study on Wired LogiC for Type Unit for PLC Output Driving)

  • 위성동;김태성
    • 전자공학회논문지T
    • /
    • 제36T권1호
    • /
    • pp.51-57
    • /
    • 1999
  • 본 논문은 온도센서 RSD. Pt 100Ω의 감지신호가 Temperature Controller의 릴레이 출력을 발생시키고 PLC 입력접점으로 입력시켜 1Scan Time으로 연산된 PLC 출력을 접점 P030에 Interface Unit를 연결시키므로 부하를 구동시키는 개발장비인 Wired Logic Type Unit에 대해서 기술하였다. 현재 PLC 교육장에서 프로그램 되어진 PLC가 부하를 구동시킬 수 있는 국내의 교육 PLC Test Kit로는 PLC와 부하 사이에 Interface 과정이 무시된 상태에서 PLC의 교육을 하도록 되어있다. 개발 키 트는 이 점을 보안하기 위해서 각종 센서 중 전자에서 언급한 온도 센서 Pt 100Ω을 이용한 온도 제어기의 릴레이 출력이 PLC 입력으로 피드백 되었을 때, 연산된 PLC 출력접점에 WLTU를 삽입시켜 PC, PLC와 부하 사이에 실시간 시스템으로 구동 시킬 수 있는 설비로, PLC 사용의 핵심원리를 쉽게 이해하고 알아 볼 수 있었다. 부하 Interface Unit인 WLTU의 구성은 구동 부분인 유 접점, 무접점, 센서, 지시 등, A접점, B접점 부하인 Motor로 나누었다.

  • PDF

AE를 이용한 복합재료 T 조인트부의 파괴거동에 관한 연구 (A Study on the Fracture Behavior of Composite Laminated T-Joints Using AE)

  • 김재훈;안병욱;사정우;박병준
    • 비파괴검사학회지
    • /
    • 제19권4호
    • /
    • pp.277-287
    • /
    • 1999
  • 탄소섬유 복합재료 T 조인트 시험편에 대한 접착특성 및 파손과정을 조사하기 위하여 단순인장 및 하중-제하 인장시험이 수행된다. 시험편은 스킨과 프레임 구조를 가지며, 동시성형과 2차 접착법에 의한 두 종류의 시험편이 제작된다. 단순인장시험동안 시험편의 손상 개시 및 진전시에 AE 특성을 측정하였고, 하중-제하 인장시험동안 진전된 균열길이는 CCD 카메라를 이용하여 측정된다. 또한 시험편 내부의 크랙면 윤곽에 대한 조사는 초음파 C-scan이 사용된다. AE 신호가 급격히 증가하는 하중과 하중-시간 곡선에서 하중강하점은 5% 이내의 오차로 비교적 잘 일치한다. 두 종류의 시험편의 초기균열은 동일한 위치인 중앙 누들부에서 발생되나 최종파단은 동시성형의 경우, 누들부에서, 2차 접착의 경우, 스킨/프레임 끝단에서 일어난다. 이런 결과로부터 두 종류의 시험편은 성형방법에 따라 서로 다른 파손 모드를 보인다.

  • PDF

대형 터치스크린의 고속감지를 위한 주파수분할 동시센싱 기법 (Frequency Division Concurrent Sensing Method for High-Speed Detection of Large Touch Screens)

  • 장운용;김형원
    • 한국정보통신학회논문지
    • /
    • 제19권4호
    • /
    • pp.895-902
    • /
    • 2015
  • 본 논문은 대형 터치스크린을 위한 고속 터치감지 및 노이즈 제거를 위한 FDCS (Frequency division concurrent sensing) 기법을 제안한다. 기존의 터치스크린 감지방식은 대부분 구동신호를 순차적으로 인가하고 순차적으로 센싱신호를 분석하기 때문에 감지속도가 터치스크린 크기에 따라 급격히 감소하여 대형터치스크린에 적용하기 어려운 문제점이 있다. 제안된 기법은 모든 드라이브라인에 서로 다른 주파수의 신호를 동시에 인가하고 각 센스 라인의 신호를 주파수 영역에서 분석하는 기법으로 대형스크린에서도 고속의 감지속도를 제공한다. 또한 주파수영역에서 노이즈 필터링기법을 제안하여 터치감지신호는 누적하고 노이즈는 상쇄하며, 터치스크린의 주파수전달함수의 역의 특성을 가지는 pre-distortion equalizer를 적용하여 터치감도 SNR을 더욱 개선한다. 23" 대형 터치스크린 모델에 실제의 환경 노이즈를 적용하여 실험한 결과 본 제안기술이 기존 기법 대비 frame scan rate을 274%, SNR을 43dB 증가시킴을 보인다.