• Title/Summary/Keyword: B-dot

Search Result 167, Processing Time 0.021 seconds

A Study on the Tradition and Identity of Bodily Expression System in India (인도 신체표현(āṅgika abhinaya)체계의 전통성과 정체성에 관한 고찰 - 『나띠야 샤스뜨라』의 규정을 중심으로 -)

  • Huh, Dongsung
    • (The) Research of the performance art and culture
    • /
    • no.18
    • /
    • pp.223-255
    • /
    • 2009
  • This paper deals with the tradition and identity of physical expression(${\bar{a}}{\dot{n}}gika$ abhinaya) system in Indian traditional theatre and dance. The ${\bar{a}}{\dot{n}}gika$ abhinaya of Indian dance and theatre has been stylized through long terms and thereby defines their identity and peculiarity by its highly stylized expression techniques while following dramatic way($n{\bar{a}}tya$-dharmi). The ${\bar{a}}{\dot{n}}gika$ abhinaya is said to had been derived from the ritualistic practice of ancient Vedic period(B.C. 15th-B.C. 5th c.), which is most clearly exemplified in hand gesture(hasta mudra). In $N{\bar{a}}tya$ ${\acute{S}}astra$, ${\bar{a}}{\dot{n}}gika$ abhinaya is explained in detail. It is classified broadly into facial expression(mukhaja abhinaya), gesture expression(śārīra abhinaya), movement expression($cest{\bar{a}}krita$ abhinaya). Further, $N{\bar{a}}tya$ ${\acute{S}}astra$ divides their various usages by parts which include head, glance, eyes, nose, eyelid, cheek, lower lip, chin, mouth, hand, chest, waist, belly, hip. thigh, claf, foot. Besides, it explains diverse ways of foot movement($c{\bar{a}}ri$), standing poses(sthana), gait(gati) and their combined movements(mandala). Many forms of Indian traditional theatre and dance basically follows the rule of ${\bar{a}}{\dot{n}}gika$ abhinaya proposed in $N{\bar{a}}tya$ ${\acute{S}}astra$, which identifies their unique characteristics.

The Perception of Virtual lines from Discrete Dot Stimuli Using Optical Neural Field (시각 신경계 개념을 이용한 이산적인 도트 자극으로부터 가상선 인식)

  • 정은화;김욱현
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.11
    • /
    • pp.150-158
    • /
    • 1996
  • Physiological observations reported and the perceptual phenomena that some simple arrays of discrete dots are perceived as a continuous curve, and others are perceived as an angular contour or as consisting of separate goups of dots. The perception of continuous curves versus discondinuous angles is mainly determined by the relative orientations of the dots, i.e., by the angles between sucessive virtual lines, whereas the length of the virtual lines gives little influence. It is important that the perception of dot stimuli is presented by vitual lines between dots in visual information processing. In this paper, on the basis of these facts of physiological observations, some experimental results on the perception of visual lines form dot stimuli are shown. Triples of the dots used in the experiment are similar to those of smith & Vos' physiological experiments.

  • PDF

A Study on the Burning Rate of Puzzle Mats (퍼즐매트의 연소속도에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.84-90
    • /
    • 2008
  • The mass loss rate and heat release rate of puzzle mats were analysed using variable external irradiation level. Five samples of puzzle mat were tested in this study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. Incident heat fluxs of $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $70kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminum foil. Each sample was nominally 20mm thick and 100mm square. The combustion heat and mass loss rate were carried out from Oxygen bomb calorimeter and mass loss calorimeter according to ISO 5660-1 respectively. Heat release rates were calculated using the equation ${\dot{Q}}=A_f{\dot{m}}"_X{\Delta}H_c=0.75A_f{\dot{m}}"{\Delta}H_c$. where $A_f$ is the horizontal burning area of the sample, $\dot{m}"$ is mass loss rate per unit area, ${\Delta}H_c$ is complete heat of combustion and 0.75 is combustion efficiency.

The Effect of Dot Pattern Size and the Variation of Coloration on Dress Wearers' Image Formation - Focused on Coloration of Value Contrast - (물방울 무늬의 크기와 배색 변화가 원피스 드레스 이미지에 미치는 영향 - 명도 대비 배색을 중심으로 -)

  • Kim, Sun-Mi;Jeong, Su-Jin
    • The Research Journal of the Costume Culture
    • /
    • v.16 no.5
    • /
    • pp.863-877
    • /
    • 2008
  • The purpose of this study is to investigate the effect of dot pattern size(0.8, 1.8, 2.5, 5, 8), color combination (BG/R, Y/B), value tone(lt/dk, p/g), area-ratio on image information. Sets of stimulus and response scales(7 point semantic) were used as experimental materials. The stimuli were 20 color pictures manipulated with the combination of dot pattern size, color combination, value tone and area-ratio using computer simulation. The subjects were 240 female undergraduates living in Gyeongsangnam-do. Image factor of the stimulus was composed of 4 different components, visibility, chastity.feminity, cuteness and attractiveness. In the visibility, color combination, value tone, area-ratio, dot pattern size showed independent effect. In the chastity feminity, color combination, value tone, showed independent effect. In the cuteness, value tone, area-ratio, dot pattern size showed independent effect. Significant interaction effects of color and area-ratio combination on visibility and cuteness were found. Interaction efforts of color and value tone combination, value tone and area-ratio was significant on cuteness. For visibility image, BG/R combination of color and yellow background/blue dots were effective. For cuteness image, pale/grayish tone and background/dots area-ratio were effective.

  • PDF

A Modified Quantum Dot-Based Dot Blot Assay for Rapid Detection of Fish Pathogen Vibrio anguillarum

  • Zhang, Yang;Xiao, Jingfan;Wang, Qiyao;Zhang, Yuanxing
    • Journal of Microbiology and Biotechnology
    • /
    • v.26 no.8
    • /
    • pp.1457-1463
    • /
    • 2016
  • Vibrio anguillarum, a devastating pathogen causing vibriosis among marine fish, is prevailing in worldwide fishery industries and accounts for grievous economic losses. Therefore, a rapid on-site detection and diagnostic technique for this pathogen is in urgent need. In this study, two mouse monoclonal antibodies (MAbs) against V. anguillarum, 6B3-C5 and 8G3-B5, were generated by using hybridoma technology and their isotypes were characterized. MAb 6B3-C5 was chosen as the detector antibody and conjugated with quantum dots. Based on MAb 6B3-C5 labeled with quantum dots, a modified dot blot assay was developed for the on-site determination of V. anguillarum. It was found that the method had no cross-reactivity with other than V. anguillarum bacteria. The detection limit (LOD) for V. anguillarum was 1 × 103 CFU/ml in cultured bacterial suspension samples, which was a 100-fold higher sensitivity than the reported colloidal gold immunochromatographic test strip. When V. anguillarum was mixed with turbot tissue homogenates, the LOD was 1 × 103 CFU/ml, suggesting that tissue homogenates did not influence the detection capabilities. Preenrichment with the tissue homogenates for 12 h could raise the LOD up to 1 × 102 CFU/ml, confirming the reliability of the method.

Study on the Enhancement of Reproducibility for Track Technology Using a Multi-dot Plate (다중시료 점적판을 이용한 트랙기입법의 재현성 증대 연구)

  • Park, Y.J.;Pyo, H.Y.;Song, B.C.;Jee, K.Y.
    • Analytical Science and Technology
    • /
    • v.17 no.5
    • /
    • pp.434-437
    • /
    • 2004
  • Alpha track technology can provide useful isotopic information of boron in the primary coolant water. In the quantitative analysis using the alpha track analysis, the shape or area of sample on the solid track detector becomes very important, especially for the analysis of liquid samples. In this research, a multi-dot plate has been developed for this purpose. The multi-dot plate provides fixed standard shape of the sample solution that stays inside of the printed circle, and consequently increases the reproducibility of the boron analysis.

Molecular Theory of Plastic Deformation (Ⅲ)$^*$

  • Kim, Jae-Hyun;Ree, Tai-Kyue;Kim, Chang-Hong
    • Bulletin of the Korean Chemical Society
    • /
    • v.2 no.3
    • /
    • pp.96-104
    • /
    • 1981
  • (1) The flow data of f (stress) and ${\dot{s}$ (strain rate) for Fe and Ti alloys were plotted in the form of f vs. -ln ${\dot{s}$ by using the literature values. (2) The plot showed two distinct patterns A and B; Pattern A is a straight line with a negative slope, and Pattern B is a curve of concave upward. (3) According to Kim and Ree's generalized theory of plastic deformation, pattern A & B belong to Case 1 and 2, respectively; in Case 1, only one kind of flow units acts in the deformation, and in Case 2, two kinds flow units act, and stress is expressed by $f={X_1f_1}+{X_2f_2}$where $f_1\;and\;f_2$ are the stresses acting on the flow units of kind 1 and 2, respectively, and $X_1,\;X_2$ are the fractions of the surface area occupied by the two kinds of flow units; $f_j=(1/{\alpha}_j) sinh^{-1}\;{\beta}_j{{\dot{s}}\;(j=1\;or\;2)$, where $1/{\alpha}_j\;and\;{\beta}_j$ are proportional to the shear modulus and relaxation time, respectively. (4) We found that grain-boundary flow units only act in the deformation of Fe and Ti alloys whereas dislocation flow units do not show any appreciable contribution. (5) The deformations of Fe and Ti alloys belong generally to pattern A (Case 1) and B (Case 2), respectively. (6) By applying the equations, f=$(1/{\alpha}_{g1}) sinh^-1({\beta}_{g1}{\dot{s}}$) and $f=(X_{g1}/{\alpha}_{g1})sinh^{-1}({\beta}_{g1}{\dot{s}})+ (X_{g2}/{\alpha}_{g2})\;shih^{-1}({\beta}_{g2}{\dot{s}})$ to the flow data of Fe and Ti alloys, the parametric values of $x_{gj}/{\alpha}_{gj}\;and\;{\beta}_{gs}(j=1\;or\;2)$ were determined, here the subscript g signifies a grain-boundary flow unit. (7) From the values of ($({\beta}_gj)^{-1}$) at different temperatures, the activation enthalpy ${\Delta}H_{gj}^{\neq}$ of deformation due to flow unit gj was determined, ($({\beta}_gj)^{-1}$) being proportional to , the jumping frequency (the rate constant) of flow unit gj. The ${\Delta}H_{gj}\;^{\neq}$ agreed very well with ${\Delta}H_{gj}\;^{\neq}$ (self-diff) of the element j whose diffusion in the sample is a critical step for the deformation as proposed by Kim-Ree's theory (Refer to Tables 3 and 4). (8) The fact, ${\Delta}H_{gj}\;^{\neq}={\Delta}H_{j}\;^{\neq}$ (self-diff), justifies the Kim-Ree theory and their method for determining activation enthalpies for deformation. (9) A linear relation between ${\beta}^{-1}$ and carbon content [C] in hot-rolled steel was observed, i.e., In ${\beta}^{-1}$ = -50.2 [C] - 40.3. This equation explains very well the experimental facts observed with regard to the deformation of hot-rolled steel..

Effects of Percutaneous Balloon Mitral Valvuloplasty on Static Lung Function and Exercise Performance (승모판협착증 환자에서 경피적 풍선확장판막성형술의 폐기능 및 운동부하 검사에 대한 효과)

  • Kim, Yong-Tae;Kim, Woo-Sung;Lim, Chae-Man;Chin, Jae-Yong;Koh, Youn-Suck;Kim, Jae-Joong;Park, Seong-Wook;Park, Seung-Jung;Lee, Jong-Koo;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.1
    • /
    • pp.1-10
    • /
    • 1994
  • Background: Patients with mitral stenosis(MS) have been demonstrated to have a variable degree of pulmonary dysfunction and exercise impairment. The hemodynamic changes of MS can be reversed after percutaneous mitral balloon valvuloplasty(PMV), but the extent and time course of the imporvement in pulmonary function and exercise capacity are not defined. Methods: In order to investigate the early(3 weeks or less)and late(3 months or more) effects of PMV on pulmonary function and determine if the pulmonary dysfunction is reversible even in patients with moderate to severe pulmonary hypertension, we performed the spirometry, measurements of diffusing capacity and lung volumes, and incremental exercise tests in patients with MS before and after PMV. Results: In 46 patients with MS(age: $40{\pm}12$years, male to female ratio: 1:2, mitral valve area: $0.8{\pm}0.2cm^2$) there was a significant increase in FVC(P<0.0025), $FEV_1$(P<0.001), $FEF_{25-75%}$(P<0.001, $FEF_{50%}$(P<0.001), PEF(P<0.0005), MVV(P<0.005), $\dot{V}O_2$max (P<0.0001), and AT(P<0.0001) after average 10 days of PMV. Also there was a significant decrease in DLco(P<0.0001) and DL/VA(P<0.0001). At later($5{\pm}2$months) follow-up in 11 patients, there was no further improvement in any parameters of pulmonary function and exercise test. Twenty nine patients with sinus rhythm were divided into 16 patients with pulmonary arterial pressure(PAP) more than 35mmHg and/or tricuspid regurgitation grade n or more(group A) and 13 patients with PAP less than 35mmHg(group B). Group A Patients had significantly lower FVC(P<0.001), $FEV_1$(P<0.001), DLco(P<0.05), $\dot{V}O_2$ max(P<0.025) and mitral valve area(P<0.025) than group B patients. Group A patients after PMV, showed significant increase in FVC(P<0.001), maximum $O_2$ pulse(P<0.00001) and $\dot{V}O_2$ max(P<0.00025). Both group showed an increase in AT(P<0.0001, P<0.005), but group A showed greater decrease in $\dot{V}E/\dot{V}O_2$ and $\dot{V}E/\dot{V}CO_2$ both at AT(P<0.001, P<0.001) and $\dot{V}O_2$ max(P<0.0001, P<0.0001) after PMV compared with group B. Conclusion: These data suggest that patients with MS can show increased pulmonary function and exercise performance within 1 month after PMV. Patients with moderate to severe pulmonary hypertension had a significant increase in exercise performance compared with those with mild to no pulmonary hypertension and it is thought to be related to a significat decrease of ventilation for a given oxygen consumption at maximum exercise.

  • PDF

Computer simulation of scattering light guide plate for LCD blacklight unit (LCD backlight용 산란형 도광판의 전산모사)

  • 김경찬;오영식;정주영;하기룡;강신원
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.136-137
    • /
    • 2001
  • LCD(Liquid Crystal Display)는 크게 투과형과 반사형으로 나눌 수 있으며 투과형 LCD의 전력소모중 약 70%를 차지하는 부분이 백라이트 유닛이다. 다른 차세대 도광판 연구와는 달리 경사면을 이용한 방법이 아니라 도광판 속에서의 산란을 조절하는 방식이다. 기존 도광판은 그림 1-(b)처럼 밑면에 dot pattern을 인쇄하여 dot의 크기, 001의 간격을 이용한 것이다. (중략)

  • PDF

Defect Detection of LCD Panel using Individual Dots Extraction Method (개별적인 Dot들의 추출 기법을 이용한 LCD 패널 불량검출)

  • 임대규;진주경;조익환;정동석
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2004.04b
    • /
    • pp.697-699
    • /
    • 2004
  • LCD의 생산이 많아짐에 따라 LCD의 불량 검출이 중요해 지고 있다. 불랑 검사는 눈으로 확인할 수 있는 범위에서 검사가 이루어지고 있으며, 만약 눈으로 식별이 불가능한 경우 적외선 카메라나 초음파 센서를 사용하여 검사가 이루어진다. 본 논문에서는 카메라를 이용하여 LCD 패널의 표면에 있는 불량 검출을 위하여 각 Dot에 대한 R, G, B 값을 추출한 후, 추출된 픽셀을 제안된 알고리즘에 적용하여 불량을 검출하는 것을 목적으로 하고 있다.

  • PDF