• Title/Summary/Keyword: B mode

Search Result 2,448, Processing Time 0.029 seconds

Compact Triple-Mode Resonator and Triple-Mode Filter Design (소형의 삼중 모드 공진기와 삼중 모드 필터 설계)

  • Lee, Ja-Hyeon;Lim, Yeong-Seog
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.4
    • /
    • pp.447-452
    • /
    • 2011
  • In this paper, we present a compact triple-mode resonator. The resonator itself can provide three transmission poles and one transmission zero. The resonance condition of each mode is analyzed theoretically, and the transmission zero is generated by open stub. Using this proposed resonator, a compact three pole bandpass filter for 2.4 GHz WLAN application with one transmission zero is designed and fabricated. The fabricated triple-mode filter shows 3 dB bandwidth of 15.8 % with the center frequency 2.4 GHz and less then 1.17 dB in 2.4~2.5 GHz passband. The size of fabricated triple-mode filter including the feed lines is 15.9 mm${\times}$9.7 mm and very compact compared with previous reported triple-mode filter.

Design of a Dual-Mode Planar Antenna Using a Reconfigurable Matching Network (재구성 정합 회로를 이용한 평판형 이중 모드 안테나 설계)

  • Kim, Yoon Geon;Kay, Youngchul;Choo, Hosung
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.12
    • /
    • pp.1337-1342
    • /
    • 2012
  • In this paper, we propose a novel reconfigurable antenna that can change the electrical shape of the matching network using RF switches of PIN diodes. The designed antenna operates at two different modes that are Mode 1 (HSDPA band, 2.1~2.2 GHz) and Mode 2(WiBro WiFi band, 2.3~2.5 GHz). The antenna is built on both sides of a polyarcylate substrate. The measured reflection coefficient shows a matching bandwidth of 547 MHz($S_{11}$ <-3 dB, 2.035~2.582 GHz) for Mode 1 and 600 MHz($S_{11}$ <-3 dB, 2.2~2.8 GHz) for Mode 2, and it shows average vertical gains of -4.4 dBi and -4.5 dBi in x-y plane, respectively.

B-mode ultrasound images of the carotid artery wall: correlation of ultrasound with histological measurements

  • Gamble G.;Beaumont B.;Smith H.;Zorn J.;Sanders G.;Merrilees M.;MacMahon S.;Sharpe N.
    • 대한예방의학회:학술대회논문집
    • /
    • 1994.02b
    • /
    • pp.169-179
    • /
    • 1994
  • B-mode ultrasound is being used to assess carotid atherosclerosis in epidemiological studies and clinical trials. Recently the interpretation of measurements made from ultrasound images has been questioned. This study examines the anatomical correlates of B-mode ultrasound of carotid arteries in vitro and in situ in cadavers. Twenty-seven segments of human carotid artery were collected at autopsy. pressure perfusion fixed in buffered 2.5% gluteraldehyde and 4% paraformaldehyde and imaged using an ATL UM-8 (10 MHz single crystal mechanical probe). Each artery was then frozen, sectioned and stained with van Gieson or elastin van Gieson. The thickness of the intima. media and adventitia were measured 'to an accuracy of 0.01 mm from histological sections using a calibrated eye graticule on a light microscope. Shrinkage artifact induced by histological preparation was determined to be 7.8%. Digitised ultra sound images of the artery wall were analysed off-line. The distance from the leading edge of the first interface ($LE_{1}$) to the leading edge of the second interface ($LE_2$) was measured using a dedicated programme. $LE_{1}$-$LE_{2}$ measurements were correlated against histological measurements corrected for shrinkage. Mean values for the far wall were: ultra sound $LE_{1}$-$LE_{2}$ (0.97 mm, S.D. 0.26), total wall thickness (1.05 mm, S.D. 0.37), adventitia (0.35 mm, S.D. 0.16), media (0.61 mm, S.D. 0.18). intima (0.09 mm, S.D. 0.13). Ultrasound measurements corresponded best with total wall thickness, rather than elastin or the intima-media complex. Excision of part of the intima plus media or removal of the adventitia resulted in a corresponding decrease in the $LE_{1}$-$LE_{2}$ distance of the B-mode image. Furthermore. increased wall thickness due to intimal atherosclerotic thickening correlated well with $LE_{1}$-$LE_{2}$ distance of the B-mode images. B-mode images obtained from the carotid arteries in situ in four cadavers also corresponded best with total wall thickness measured from histological sections and not with the thickness of the intima plus media. In conclusion, the $LE_{1}$-$LE_{2}$ distance measured on B-mode images of the carotid artery best represents total wall thickness of intima plus media plus adventitia and not intima plus media alone.

  • PDF

Ductile Fracture Behavior of AS4P Under Mixed Mode (I/II) Loading

  • Oh, Dong-Joon
    • Journal of Mechanical Science and Technology
    • /
    • v.16 no.4
    • /
    • pp.476-484
    • /
    • 2002
  • The aim of this study is to investigate the ductile fracture behavior under mixed mode (I/II) loading using SA533B pressure vessel steel. Anti-symmetric 4-point (AS4P) bending tests were performed to obtain the J-R curves under two different mixed mode (I/II) loadings. In addition, finite element analysis using Rousselier Ductile Damage Theory was carried out to predict the J-R curves under mixed mode (I/II) loadings. In conclusions, the J-R curves under. Mixed Mode (I/II) loading were located between those of Mode I and Mode II loading. When the mixity of mixed mode (I/II) loading was high, the J-R curve of mixed mode (I/II) loading approached that of pure mode I loading after some amount of crack propagation. In contrast with the above fact, if the mixity was low, the J-R curve took after that of pure mode II loading. Finally, it was found that the predicted J-R curves made a good agreement with the test data through the tuning procedures of $\beta$ values at the different mixed mode (I/II) loading.

Automatic Detection of Fetal Movement Using M-Mode Ultrasonography (M-Mode 초음파 영상을 이용한 태동의 자동 검출)

  • Kwon, J.H.;Kang, D.J.;Kim, S.B.;Park, M.I.;Kim, Sun-I.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.179-180
    • /
    • 1998
  • In this paper, we propose an algorithm to detect fetal movements using M-mode ultrasonography. To do this work automatically, we find the crosscorrelation between the current data vector of the depth direction of M-mode image and the previous one. In the crosscorrelation estimator, the variations of time lag $\tau$ at maximum crosscorrelation value means fetal movements. A woman in the 37th week of pregnancy was monitored and the ultrasonic image of fetus was recorded over 20-minute period to detect fetal movements using B-mode and M-mode ultrasonography simultaneously. And the presented method was compared with maternal perception and B-mode ultrasonography observed by clinician. The maternal perception method detected only 57% of all fetal movements observed by clinician. The detection of the presented method corresponds to the clinician's detection result.

  • PDF

Effect of satellite link noise for satellite range measurement using tone method (Tone 방식을 사용한 위성 거리 측정에 대한 위성 링크 잡음의 영향)

  • Kim Young Wan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.42 no.2 s.332
    • /
    • pp.9-16
    • /
    • 2005
  • The performance of satellite range measurement using tone method was analyzed in the presence of satellite link AWGN. The phase errors in range measurement are generated by AWGN of satellite up- and down-link and the degradations of satellite range measurement are dependent on the transmission mode and loop bandwidth of satellite measurement system. The analyzed effects for satellite measurement in presence of satellite link noise were also analyzed with the measured satellite range data via satellite range measurement system operating in satellite link AWGN. In RAU mode, the satellite range differences of 14.4 to 40.6 m were occurred according to the loop bandwidth of satellite range measurement system and the degradation of 0.3 dB compared with theoretical value was generated under condition of the signal-to-noise ratio of 43 dB. In RAU and TM mode, the performances of range measurement were approximately agreed to the that of RAU mode. In order to get the equal performance characteristics with RAU mode, the signal-to-noise ratio of satellite link for RAU and TM mode should be increased by signal power of 2.3 dB, which is a power loss due to transmission of telemetry signal.

HMSIW Balanced Filter for Improved Isolation between Output Ports (출력 단자 간의 격리 특성이 향상된 HMSIW 평형 여파기)

  • Hwang, Seok-Min;Byun, Jin-Do;Lee, Hai-Young
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.2
    • /
    • pp.173-181
    • /
    • 2011
  • In this paper, we propose a half mode substrate integrated waveguide(HMSIW) balanced bandpass filter to yield improved isolation between output ports. In order to achieve good isolation, resistive coupling slot is employed in HMSIW filter. The measurement results show that the insertion losses($S_{21}$, $S_{31}$) are $5.4{\pm}0.2$ dB and input return loss($S_{11}$) is more than 10 dB from 5.8 GHz to 6.4 GHz. Moreover isolation between output ports is larger than 18 dB and phase difference of output ports is $180{\pm}10^{\circ}$.

Electrical Characteristics of 3rd Overtone Mode Energy-trapped High Frequency Filter using PbTiO3 System Ceramics (PbTiO3계 세라믹스를 이용한 3차 진동모드 에너지 트랩형 고주파필터의 전기적 특성)

  • 오동언;류주현;윤현상;박창엽;이수호;김종선;정회승
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.7
    • /
    • pp.593-598
    • /
    • 2003
  • In this paper, 3rd overtone mode energy-trapped filter using modified PbTiO$_3$ system ceramics was manufactured to apply for intermediate frequency(IF) SMD type fillet with splitted electrode and gap size. To investigate the effects of splitted electrode and gap size on filter characteristics of 3rd overtone mode energy-trapped filter, ceramic wafers were fabricated by etching splitted rectangular electrode size(b$\times$d) of b=0.4, 0.6, 0.8, 1mm, d=0.3, 0.4, 0.5, 0.6mm and gap size(c) c=0.2, 0.3, 0.4, 0.6mm, respectively. And then, SMD type ceramic filter were fabricated with the size of 3.7$\times$3.1$\textrm{mm}^2$. SMD type ceramic filter with the size of b=0.8mm, d=0.4mm and gap(c)=0.4mm, which showed insertion loss of 2.951dB, 3dB bandwidth of 54.7kHz and 20dB stop bandwidth of 129.27kHz, was suitable for IF bandpass filter application.

A Reconfigurable Power Divider for High Efficiency Power Amplifiers (고효율 전력 증폭기를 위한 재구성성이 있는 전력 분배기)

  • Kim, Seung-Hoon;Chung, In-Young;Jeong, Jin-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.20 no.2
    • /
    • pp.107-114
    • /
    • 2009
  • In this paper, high efficiency amplifier configuration is proposed using the reconfigurable power divider. In order to enhance average efficiency of linear power amplifiers for wireless communication, it is required to increase efficiency in low output power region. The proposed power divider operates in two modes, high power mode and low power mode, according to output power. In each mode, it allows impedance matches and low loss, which is made possible by employing two $\lambda/4$ coupled lines and two switches. The fabricated power divider shows the return loss ($S_{11}$) and insertion loss ($S_{21}$) of -16.49 dB and -0.83 dB, respectively, in low power mode. In high power mode, the measured return loss ($S_{11}$) and insertion loss ($S_{31}$) are -16.28 dB and -0.73 dB, respectively. This result successfully demonstrates the reconfigurability of the proposed power divider.

Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital (종합병원 진단용방사선장비의 고장유형 분석)

  • Lee, Woo-Cheul;Kim, Jeong-Lae
    • Journal of radiological science and technology
    • /
    • v.22 no.2
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF