• Title/Summary/Keyword: B 계통

Search Result 874, Processing Time 0.035 seconds

Analysis of Harmonic Effects on Substation Power System and its Countermeasure (지하철 전력계통의 고조파 영향 분석 및 그 대책에 관한 연구)

  • Song, Jin-Ho;Hwang, Yu-Mo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.4
    • /
    • pp.210-220
    • /
    • 2002
  • We analysised the effect of harmonics on electric machines of substation power system barred on quantitatively measured harmonics and proposed the methods for prevention of harmonics through checking on transformer, rectifier and cable's capacities against harmonics with reference to KEPCO's electricity service standard. In order to analysis harmoninics of silicon rectifier that is power source in DC substation, computer simulations for a substation with TR of high voltage distribution switchboard are performed. Simulation results show that the total harmonic distortion factor becomes smaller for TR primary and receiving points in order rather than silicon rectifier which is harmonic generation source so that the harmonics generated frets each rectifier are outflowed to power supply and high voltage distribution switchboard The result of higher distortion factors of voltage and current for rectifier with 100% load than those with 50 % and 30% indicates that the waveform of voltage and current for the real substation power system at the office-going and the closing hours with heavy loads might be more distorted. As proposed methods for harmonic reduction, the conventional 6 pulse-type for substation is required to be replaced by 12 pulse-type for reduction of 5th and 7th harmonics. The active filter rather than the passive filter is more effective due to severe variance of rectifier loads, but the high cost is price to be paid. In view of installation area and costs, the use of 12 pulse-type transformer is desirable and then the parallel transformer and the rectifier within the substation must be replaced at the same time. Other substations with parallel feeder can use 6 pulse-type transformer.

CFD Analysis of a Concept of Nuclear Hybrid Heat Pipe with Control Rod (원자로 제어봉과 결합된 하이브리드 히트파이프의 CFD 해석)

  • Jeong, Yeong Shin;Kim, Kyung Mo;Kim, In Guk;Bang, In Cheol
    • The KSFM Journal of Fluid Machinery
    • /
    • v.17 no.6
    • /
    • pp.109-114
    • /
    • 2014
  • After the Fukushima accident in 2011, it was revealed that nuclear power plant has the vulnerability to SBO accident and its extension situation without sufficient cooling of reactor core resulting core meltdown and radioactive material release even after reactor shutdown. Many safety systems had been developed like PAFS, hybrid SIT, and relocation of RPV and IRWST as a part of steps for the Fukushima accident, however, their applications have limitation in the situation that supply of feedwater into reactor is impossible due to high pressure inside reactor pressure vessel. The concept of hybrid heat pipe with control rod is introduced for breaking through the limitation. Hybrid heat pipe with control rod is the passive decay heat removal system in core, which has the abilities of reactor shutdown as control rod as well as decay heat removal as heat pipe. For evaluating the cooling performance hybrid heat pipe, a commercial CFD code, ANSYS-CFX was used. First, for validating CFD results, numerical results and experimental results with same geometry and fluid conditions were compared to a tube type heat pipe resulting in a resonable agreement between them. After that, wall temperature and thermal resistances of 2 design concepts of hybrid heat pipe were analyzed about various heat inputs. For unit length, hybrid heat pipe with a tube type of $B_4C$ pellet has a decreasing tendency of thermal resistance, on the other hand, hybrid heat pipe with an annular type $B_4C$ pellet has an increasing tendency as heat input increases.

Characteristics and Antibiotic Susceptibility of Imipenem-Resistant Clinical Isolates Producing Carbapenemase (Carbapenemase를 생산하는 imipenem 내성 세균의 특성 및 항생제 감수성)

  • Choe, Han-Na;Park, Chul;Kim, Hyung-Rak;Baik, Keun-Sik;Kim, Se-Na;Seong, Chi-Nam
    • Journal of Life Science
    • /
    • v.20 no.8
    • /
    • pp.1214-1220
    • /
    • 2010
  • Imipenem-resistant bacteria were isolated from clinical specimens taken from hospitalized patients in Suncheon, Korea. Fifty-four isolates were phylogenetically analyzed based on 16S rRNA gene and gyrB gene sequence comparisons. Isolates were affiliated with Pseudomonas aeruginosa (30 strains; 55.6%), Acinetobacter baumannii (21; 38.9%), Enterobacter hormaechei (2) and Pseudomonas putida (2). Twenty-two isolates produced metallo-$\beta$-lactamase (MBL); 12 Acinetobacter baumannii strains, 7 Pseudomonas aeruginosa strains, 2 P. putida strains and 1 Enterobacter hormaechei strain. Antibiotic susceptibility of the isolates was determined using the disc diffusion method and Vitek system. Strains producing metallo-$\beta$-lactamase (type IMP & VIM) were more resistant to antibiotics ceftazidime, aztreonam, amikacin and gentamicin than to strains producing OXA and SHV type of $\beta$-lactamase.

Detection Technique and Device of Series Arcing Phenomena (직렬아크현상의 검출기술 및 장치)

  • Ji, Hong-Keun;Jung, Kwang-Suk;Park, Dae-Won;Kil, Gyung-Suk;Seo, Dong-Hoan;Rhyu, Keel-Soo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.332-338
    • /
    • 2010
  • Annually, electrical fires caused by arcing phenomena in power system rapidly increase as the use of more electric appliances, but there is no established method for the prevention of the accidents. With this background, this paper dealt with the experimental results on a series arc detection technique and a device for air conditioners. Series arcing phenomena that is generated in incomplete connection of air conditioners was simulated, and the frequency spectrum was analyzed. The Fast Fourier Transform (FFT) of the arc pulse showed that the dominant frequency components exist in ranges of 190 kHz~250 kHz and 900 kHz~1.6 MHz. An arc detection circuit with low cut off frequency of 170 kHz to attenuate 60 Hz by 170 dB and a signal discriminator were designed. Also, an algorithm which separate series arc signal from unwanted noises produced by switching operation, inverter, and surge was proposed. Application experiment was carried out on several types of air-conditioners by using the arc generator specified in UL1699, and the results showed the over 99 % accuracy.

Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis (수냉각 발전기 고정자 권선의 건조 과정 분석을 통한 누설 및 흡습 예측 진단에 관한 실험적 연구)

  • Kim, Hee-Soo;Bae, Yong-Chae;Lee, Wook-Ryun;Lee, Doo-Young
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.9
    • /
    • pp.867-873
    • /
    • 2010
  • The failure of water-cooled generator stator windings as a result of insulation breakdown due to coolant water leaks and water absorption often occurs worldwide. Such failure can cause severe grid-related accidents as well as huge economic losses. More than 50% of domestic generators have been operated for over 15 years, and therefore, they exhibit signs of aging. Leaking and water-absorbing windings are often found during an overhaul. In an existing method for evaluating the integrity of generator stator windings, the drying process of the interior of the windings is ignored and only final leak tests are performed. In this study, it is shown that water leaks and water absorption in stator windings can be detected indirectly through vacuum pattern analysis in the vacuum drying mode, which is the used in the preparation stage of the leak test.

Numerical Study on Cavitation Reduction in Velocity-Control Trim of Valve with High Pressure Drop (고차압 밸브의 속도제어형 트림에서 케이테이션 억제에 관한 수치적 연구)

  • Kim, Dae Kwon;Sohn, Chae Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.9
    • /
    • pp.863-871
    • /
    • 2013
  • Flow characteristics of velocity-control trim in a valve is investigated numerically with high pressure drop. A basic trim widely used for a valve in domestic powerplants is selected and designed for a baseline of velocity-control trim. The numerical analysis is focused on flow rate and cavitation with the basic trim. For a condition of high-pressure drop, pressure drop between inlet and outlet and fluid temperature are selected to be 18.1 MPa and $160^{\circ}C$, respectively, which are typical ones considering operating conditions adopted in powerplants. With this baseline model and condition, design changes are made for improvement of flow rate and cavitation phenomenon. For re-design, trim is divided into three zones in radial direction and design parameters of flow area, stage, and flow direction are considered in each zone. With these combined parameters applied to each zone, 4 models with design changes are proposed and their flow rates and cavitation areas are investigated. From comparison with those in the baseline model of a basic trim, proposed models show better performance in both flow rate and cavitation.

Isolation and Identification of Antimicrobial Compound from Mokdan Bark (Paeonia suffruticosa ANDR) (목단피로부터 식품부패 미생물에 대한 항균성 물질의 분리 및 동정)

  • 황재선;한영실
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.32 no.7
    • /
    • pp.1059-1065
    • /
    • 2003
  • Antimicrobial activity of Mokdan bark (Paeonia suffruticosa $A_{NDR}$) was investigated. Methanol extract of dried Mokdan was fractionated to hexane, chloroform, ethylacetate, butanol and aqueous fraction. Ethylacetate fraction among these fractions showed the highest inhibitory effect on the microorganisms such as L. monocytogenes, and E. coli at 500 $\mu\textrm{g}$/disc. Ethylacetate fraction was further fractionated into 3 fractions by silica gel column and thin layer chromatography (TLC). The results showed that ethylacetate fractions No. 1 and 2 had the highest antimicrobial activity. They were mixed again, reseparated, and 3 fractions were obtained. Among them, No. 1 had the highest inhibitory effect on the microorganisms, No. 1 fraction was identified as isobutyl isopentanoate by HPLC, and GC-MS.

Studies on the Resistance to Black shank of leaf tobacco (담배 역병 저항성 검정에 관한 연구)

  • Il Hou;Yu-Sun Ban
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.8 no.1
    • /
    • pp.105-110
    • /
    • 1970
  • Resistance to Black shank of various varieties were investigated in field and incubator. The results were summarized as follows; 1) In occurrence of this disease, yellow tobacco varieties were ranged from 4 days to 12 days after inoculated. 2) Korean native varieties were ranged from 6 days to 20 days. 3) Orient tobacco takes from 8 days to 17 days in occurrence of this one. 4) Japanese varieties ranged from 4 days to 3 days in occurrence of this disease. 5) Dark air-curing tobacco was ranged from 5 days to 14 days. 6) Chinese variety was ranged from 6 days to 11 days. Each varieties of resistant to Black shank was as follows; 1) Yellow tobacco varieties; Cash, Oxford-1, Oxford-3, N.C-75, N.C-95, Golden-cure Delcrest. 2) Native varieties; Sinzongtchio, Muktchio Sosa-3 Mokgitchio. 3) Japanese varieties; Hatano Outaruma Maruha. 4) Chinese variety; Gkzuoe, Yung-zung, Tongzuoe. 5) Orient tobacco; Samsun, Baffra, Xanthix. 6) Dark air-curing varieties; B-Hw, Connecticut-Broad leaf, Connecticut-Havana, Tennessee-Black.

  • PDF

Molecular Systematics of Rhizoctonia solani Isolates from Various Crops with AFLP (AFLP를 이용한 Rhizoctonia solani 균주들의 분자계통학적 특성규명)

  • 최혜선;김경수;김희종;이윤수
    • Korean Journal of Microbiology
    • /
    • v.36 no.1
    • /
    • pp.40-45
    • /
    • 2000
  • Rhizoctonia solani Kuhn[Thanatephorus cucumeris (Frank) Donk]is a destrutive soil-borne plant pathogen affecting many agricultural crops worldwide. R. solani is divided into anastomosis groups based on the ability of the hyphae to fuse, and into subgroups based on morphological, physiological characteristics. AG classifications are convenient and useful in identifying primary causal agents of Rhizoctonia diseases, although the mechanism of anastomosis is not fully understood. Beacause of the difficulties, we sought to develop a more direct method for genetic identification and charaterization of R. solani. Twenty nine isolates of R. solani were used for the analysis of genetic relationships among themselves and for rapid anastomosis grouping with AFLP method. All isolates studied were divided into five groups. Isolate 6 was included in AG-3 with 67% genetic similarity. When isolates 3 was compared with 13 and 10 each, they showed more than 84% and 83% similarity, respectively. Isolates 3, 4, 5, 13, and 16 were included in AG-1 with 83% genetic similarity. Isolates 1, 7, and 8 were included in AG-1(IB).

  • PDF

Antifungal Susceptibility of Microsporum canis isolated from canine dermatophytosis (개 피부병 유래의 Microsporum canis의 항진균제 감수성)

  • Han, Ki-ok;Choi, Won-pil
    • Korean Journal of Veterinary Research
    • /
    • v.41 no.2
    • /
    • pp.173-176
    • /
    • 2001
  • The present study was conducted to examine the drug susceptibility of 57 strains of Microsporum canis isolated from dogs with dermatitis in Taegu, 1999. Antifungal susceptibility test was performed by the microdilution method, using 7 antifungal drugs as follows: itraconazole(I), terbinafine(T), ketoconazole(K), griseofulvin(G), amphotericin B(A), flucytosine(5-Fc)(F), tolnaftate(To). All tester strains of M canis were highly susceptible to T, I, K and To(geometric mean $MICs{\leq}0.007{\sim}0.155{\mu}g/ml$), while those were lowly susceptible to G, A and F(geometric mean MICs $0.285{\sim}26.430{\mu}g/ml$).

  • PDF