• 제목/요약/키워드: B 계통

검색결과 876건 처리시간 0.024초

계통보조서비스에서 부하자원의 활용방안에 대한 고찰 (A Study of Demand Response Resource in Ancillary Service)

  • 김성철;유성영;김형준;김형중;박종배;신중린
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.663-665
    • /
    • 2004
  • There are some demand response program which is Direct Load Control and so on in Korea. These are used to manage lack of power stability or shift peak time for shading load. It is very important not only using stability power system but controling and scheduling power system on the whole. Interruptible loads are essential resources to solve lack of energy and limit of constructing generator On recently days, Demand Response Program's reliability is recognized as ancillary or reserve service in many country. This paper presents a necessity to apply demand resource to our ancillary program. For this reason, it is introduce overseas ancillary program using load resource.

  • PDF

전압안정도 향상을 위한 무효전력 보상설비 설치 사례 연구 (A Study on the Applications of Rective Power Compensators to Improve the Voltage Stability)

  • 이정호;오태규;이상호;김태옥;이병준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.147-149
    • /
    • 2004
  • 미국 서부지역의 정전 경험을 통해 전압불안정 방지를 위한 무효전력 보상설비에 관한 연구가 진행되었고 STATCOM, SVC 둥과 같은 FACTS를 이용한 무효전력 보상설비의 설치 사례가 최근 보고되었다. 국내에서는 수도권 지역의 전력계통 운영 상환을 고려하여 전압안정도 향상을 위한 순동무효전력 설비 설치에관한 연구가 진행 중에 있으며, 본 논문에서는 최적의무효전력설비를 선정하기 위하여 해당분야의 국외사례를 조사, 비교, 분석하였다.

  • PDF

송전선로 보호용 보호계전기 시험을 위한 계통모델 개발에 관한 연구 (A Study of the Development of Power System Model for Performance Test of Transmission Line Protective Relay)

  • 서훈철;이홍학;김철환;이재욱;장병태;곽노홍;김호표;김일동
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.430-432
    • /
    • 2004
  • The standard power system model is needed to test a transmission line protective relay There are two methods to develop a power system model for transmission line protection. First method is based on characteristic power system model, and second method is based on functional power system model. This paper presents a standard power system model for performance test of transmission line protective relay, where the power system model is based on the two methods. And this model is simulated by using RTDS to test a protective relay.

  • PDF

전력계통설비의 정지관리 체계화 방안에 대한 연구 (A Study on the Outage Management Standards for Power System)

  • 허정용;김철환;김재철;이건웅;이성진;이창규;조범섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 A
    • /
    • pp.107-109
    • /
    • 2004
  • It is very important to operate a power system safely. An fault may causes the cascading outages in power system. Use of systematic, precise definitions related to the outages is essential for meaningful exchange of data. Moreover, it is necessary that specific instructions for reporting outages is developed. This paper presents the outage management for a power system. The outage managements of the many utilities are researched, which include the definition, classification, index and report of outage. Finally, the outage management standard is proposed, and the necessity and structure of KERC(Korean Electric Reliability Council) are presented

  • PDF

ER 브레이크 및 클러치를 이용한 이송 테이블의 위치추적제어 (Position Tracking Control of a Moving Table Using ER Brake/Clutch)

  • 최승복;이호근;김승래;정재천;한문식
    • 한국정밀공학회지
    • /
    • 제15권11호
    • /
    • pp.208-217
    • /
    • 1998
  • 본 연구에서는 ER 브레이크와 ER클러치를 피드백작동기로 사용하여 이송테이블의 위치 추적제어를 수행하였다. 이를 위해 먼저 아라빅 검(arabic gum)계통의 ER유체를 자체조성한 후 전기장에 대한 빙햄(Bingham)모델을 실험적으로 도출하였다. 빙햄모델에 근거하여 평판형의 ER브레이크와 실린더형의 ER클러치를 설계 제작하였으며, 계단입력(step input)전기장에 따른 출력토오크특성을 통하여 이들 작동기의 동적모델을 얻었다. 이들 작동기와 연계된 이송테이블시스템의 운동지배방정식을 유도한 후 위치추적제어를 위한 슬라이딩모드제어기를 설계하였다. 제어기 설계시 이송해이블의 부하질량 변화에 대한 시스템 불확실성과 마찰력을 고려하여 제어성능의 강건성을 보장하도록 하였다. 제안된 제어시스템의 제어영역(control bandwidth)을 주파수 영역에서 고찰한 후 여러 레적에 대한 위치추적제어 실험을 수행하였다.

  • PDF

전자계통 현상 시각화 MMI 개발에 관한 연구 (A Study of the development of a visualization MMI for Power System Phenomenons)

  • 이욱화;박인권;김욱;이진;최종웅;윤용범;장길수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.175-177
    • /
    • 1999
  • This paper presents a prototype of visualization MMI of the Power System Phenomenon, specially synchronous machine dynamics and frequency deviations of power system for KEPCO's Enhanced Power System Simulator(KEPS)[1]. And some visualization designs of the Power System Phenomenons such as voltage stability, transient stability, SSR, Line overflow, and voltage deviations are presented. The prototype MMI has included the animations & 3D graphics presentations for synchronous machine rotor deviations and frequency deviations. So, a user can intuitively acquire the basic concepts of the power system oscillations. Finally, it will be scheduled to development of the various visualization MMI of the power system phenomenons for development and installation of KEPS.

  • PDF

핵의학 검체검사 정도관리의 개선을 위한 Westgard Multi-Rules의 적용 (Application of Westgard Multi-Rules for Improving Nuclear Medicine Blood Test Quality Control)

  • 정흥수;배진수;신용환;김지영;석재동
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.115-118
    • /
    • 2012
  • Levey-Jennings 정도관리는 측정치가 관리 허용치(평균 ${\pm}2SD$ 또는 ${\pm}3SD$)를 벗어나는 우연오차만 관리를 했었다면, Westgard Multi-Rules 정도관리는 우연오차와 계통오차의 분리분석을 할 수 있고 복합적용이 가능해 병원 인증 내부정도관리에서도 적극 권장하고 있다. 하지만 검체검사 정도관리에서는 kit 내 같은 기질의 정도관리 물질을 사용해 계통오차의 인지가 쉽지 않고 잦은 농도 변경으로 목표치 설정이 어려워 Westgard Multi-Rules의 적용이 힘들었다. 따라서 본 연구는 정도관리 물질을 상용화된 제 3의 물질을 사용해 신뢰성 있는 목표치를 산출하고 Westgard Multi-Rules을 적용함으로써 정도관리를 개선하고자 한다. 갑상선 검사인 Total T3를 대상으로 정도관리 물질을 B사의 Immunoassay Plus Control Level 1, 2, 3를 사용하여 ${\pm}2SD$를 벗어난 값을 제외한 1개월 동안 295회 데이터의 평균값으로 목표치를 설정하였다. 그리고 20일간 총 194회 실험의 정도관리 물질 측정치를 표준편차 지수를 이용하여 하나의 관리도상에 놓고 Westgard Multi-Rules 중 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T의 규칙들을 적용하여 우연오차와 계통오차를 분리하여 분석하였다. Total T3의 목표치는 정도관리 물질 1, 2, 3번이 각각 84.2 ng/dl, 156.7 ng/dl, 242.4 ng/dl로 설정되었고 표준편차는 각각 11.22 ng/dl, 14.52 ng/dl, 14.52 ng/dl로 설정되었다. 설정된 목표치를 기준으로 Westgard Multi-Rules을 적용한 뒤 유형을 분석한 결과 우연오차인 12s가 48회, 13s가 13회, R4s가 6회로 분석되었고 계통오차인 22s는 10회, 41s가 11회, 2 of 32s가 17회, $10\bar{x}$가 10회로 분석되었으며 7T는 적용되어지지 않았다. 통제 불가능한 우연오차의 유형들은 전체실험과정을 재확인하고 재검사 비중을 높이는 등의 조치를 취하였으며 통제 가능한 계통오차의 유형들은 원인을 찾아 조치사항 양식에 기록하고 필요 시 내부정도관리 위원회에 보고하였다. 상용화된 제 3의 물질을 정도관리 물질로 사용하고 목표치를 설정함에 따라 하나의 관리도 상에서 3가지 정도관리 물질에 대한 Westgard Multi-Rules의 적용이 가능하게 되었고, 그 결과 12s, 22s, 13s, 2 of 32s, R4s, 41s, $10\bar{x}$, 7T 규칙들의 분석으로 우연오차와 계통오차의 정밀분석이 가능해 졌다. 또한 ${\pm}3SD$ 내의 모든 데이터를 분석 할 수 있어 Error 검출을 최대화 할 수 있게 되었다. 이와 같이 체계적으로 Westgard Multi-Rules을 적용한 정도관리는 검체검사의 정도관리에 질적 향상을 가져다 줄 것이다.

  • PDF

원자로 일차 냉각제 계통내 탈염공정의 양이온 교환수지상에서 니켈(Ni), 코발트(Co) 및 은(Ag) 이온의 흡착 특성 (Adsorption Characteristics of Ni, Co and Ag Ions on The Cation Exchange Resin of Demineralization Process in Primary Coolant System of PWR)

  • 양현수;김영호;강덕원;성기방
    • 공업화학
    • /
    • 제10권1호
    • /
    • pp.51-57
    • /
    • 1999
  • 원자로 정지시 냉각제 계통내 탈염 공정의 최적운전에 도움을 줄 목적으로 Amberite IRN 77 양이온 교환수지상에서 Ni(II), Co(II) 및 Ag(I) 이온의 흡착특성을 연구하였다. 양이온 교환수지상에서 Ni(II), Co(II) 및 Ag(I) 이온 각각의 흡착 메카니즘은 Langmuir isotherm에 잘 일치하였다. 양이온교환수지의 형태에 따른 영향으로서 $H^+$-형의 수지의 흡착 및 처리 용량은 $Li^+$-형의 수지보다 우수하였다. 다성분계의 용액을 위한 연속식 이온교환공정에서 양이온교환수지의 흡착선택성은 Ni(II)${\approx}$Co(II)>Ag(I)였으며, 유속의 증가는 수지의 처리용량 뿐만 아니라 파과곡선의 기울기를 감소시켰다.

  • PDF

22.9[kV] 지중배전계통케이블의 동심중성선에 흐르는 순환전류의 제거방안 및 효과 (An Elimination Method Of the Circulating Current Flowing into Coaxial-Neutral Lines in 22.9[kV] CNCV Underground Cable Systems)

  • 전명수;송중호
    • 조명전기설비학회논문지
    • /
    • 제22권2호
    • /
    • pp.107-113
    • /
    • 2008
  • 22.9[kV]-y 배전 방식은 지중 케이블로 전력을 공급하고 있으며 선로 운영상 배전케이블 선로의 동심중성선을 케이블 접속 구간마다 3선 일괄 접지하는 다중 접지방식을 채택하고 있다. 그러나 지중 배전 선로에서 각 상의 부하가 평형일 경우에도 동심중성선에는 부하 전류의 약 40[%](전력구)${\sim}$50[%](관로)의 동심중성선 순환 전류가 발생되고 있기 때문에, 순환전류로 인한 손실이 도체 손실의 76[%]에 달한다. 이러한 손실 전력으로 케이블의 내부온도가 상승되어 케이블의 허용전류 용량이 관로의 경우 20[%] 정도 감소하게 된다. 본 논문은 이와 같은 문제점을 해결하기 위하여 새로운 동심중성선 접지방식을 제안하고 있다. 새로운 방법은 동심중성선의 순환전류를 효과적으로 제거하고 있으며, 그 방안을 직접 계통망에서 적용시켜서 실측하여 본 결과, 그 타당성과 유용성을 확인하였다.

양성자 가속기 연구센터 관련 전력설비 설계 현황 (Electric Power System Design Status for the Proton Accelerator Conventional Facilities of PEFP)

  • 문경준;전계포;민의섭;남정민;김준연;김보현;정우성;유석태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 A
    • /
    • pp.496-497
    • /
    • 2006
  • 90년대에 들어서면서부터 미래원천기술 개발에 필요한 양성자원 및 중성자원의 중요성이 부각됨으로써, 이에 적합한 고에너지(수백 MeV${\sim}$수 GeV) 및 대전류(수십 mA)의 대형 양성자 가속기가 개발되어 반도체 생산, 의료장비 등 여러 분야에 널리 적용되고 있는 추세이다[1, 2]. 이에 양성자 사업단은 21세기 미래 원천기술을 개발하고 산업경쟁력을 제고하며 공공복지를 증진시킬 수 있는 양성자가속기를 개발하여, NT, BT, IT, ST등 중요 국가과학기술분야의 발전기반을 확충하기 위한 프론티어 사업목표로 하고 있으며 이에 부응할 수 있는 양성자 가속기 연구센터 건설계획을 설정하여 추진 중에 있다. 본 논문에서는 양성자 가속기 연구센터 건설계획 과정 중에서 전력설비 설계 방법, 즉 154kV 수전 설비, 직류전원계통, 무정전 전원계통 설비, 접지 및 피뢰설비의 기능 및 특징에 관해 기술하고자 한다.

  • PDF